AC/DC Open Frame Power Supply (PSU), Medical, 4 Output, 200W @ 25CFM, 140 W, 90V AC to 264V AC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Open Frame Power Supplies
- No. of Outputs:4 Output; Power Rating (Covection Cooling):140W; Power Rating (Forced Cooling):200W @ 25CFM; Input Voltage VAC:90V AC to 264V AC; Power Supply Output Type:Adjustabl
- SVHC: No SVHC (25-Jun-2025)
- Product Range: MPQ-200 Series
- No. of Outputs: 4 Output
- Output Power Max: 200W
- Input Voltage VAC: 90V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 90V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 15A
- Output Current - Output 2: 3A
- Output Current - Output 3: 2A
- Output Current - Output 4: 2A
- Output Voltage - Output 1: 5VDC
- Output Voltage - Output 2: 24VDC
- Output Voltage - Output 3: 12VDC
- Output Voltage - Output 4: -12V
- Power Supply Applications: Medical
- Power Rating (Forced Cooling): 200W @ 25CFM
- Power Rating (Convection Cooling): 140W
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 83.24 € |
| Current stock | 10+ |
| Lead time | 30 days |
**MPQ - 200 series** 1~4 Output Medical Type ## ■ **Features** **==> picture [42 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> User’s Manual<br>**----- End of picture text -----**<br> - ‧Universal AC input / Full range - ‧Low leakage current <150 Aμ - ‧Protections: Short circuit / Overload / Over voltage / Over temperature - ‧Free air convection for 140W and forced air convection for 200W - ‧Medical safety approved (2 x MOPP between primary to secondary)(Note.8) - ‧With power good and fail signal output - ‧Built-in remote ON-OFF control - ‧Built-in remote sense function - ‧Fixed switching frequency at 100KHz - ‧3 years warranty ## ■ **** ## ■ **Specification** FAL G® Adis ~~4~~ CBC EXE **TPTC004 UL60950-1 BS EN/EN60601-1 IEC60601-1** ## **WORKING TEMP.** Whole series can operate from -20~70℃. Please refer to the derating curves. ## **AC INPUT VOLTAGE** 90~264 VAC, 47~63Hz / 127~370VDC. ## **WORKING HUMIDITY** 20~90% RH non-condensing. ## **POWER FACTOR (Typ.)** PF>0.95/230VAC PF>0.98/115VAC at full load ## **STORAGE TEMP., HUMIDITY** - -40~+85℃, 10~90% RH ## **AC INPUT CURRENT (Typ.)** Maximum input current 3.5A at 115VAC, 60Hz or 1.6A at 230VAC, 60Hz with 100% output load. ## **INRUSH CURRENT (Typ.)** Inrush current is less than 25A at 115VAC or less than 40A at 230VAC under cold start conditions. Limiting provided by internal thermistors. ## **SETUP, RISE TIME** 1000ms, 20ms / 230VAC at full load 3000ms, 20ms / 115VAC at full load ## **HOLD-UP TIME (Typ.)** 16ms / 230VAC at full load 16ms / 115VAC at full load ## **TEMP. COEFFICIENT** - ±0.04%/℃ on all outputs at full load between 0~50℃ of ambient temperature. ## **VIBRATION** 2G of acceleration, vibrating frequency adjust from 10Hz ~500Hz within a 10-minute cycle. 6 testing cycles (60 minutes) each along X, Y, Z axes. ## **SAFETY STANDARDS** Medical **:** ANSI/AAMI ES60601-1, TUV BS EN/EN60601-1, IEC60601-1, EAC TP TC 004 approved Commercial : Also design refer to UL60950-1 ## **WITHSTAND VOLTAGE** 4000VAC between input and output 2000VAC between input and F.G. 1500VAC between output and F.G. ## **ISOLATION RESISTANCE** ## **LEAKAGE CURRENT Note.7** Earth leakage current < 150 A/264VAC , μ Touch current < 100 A/264VACμ ## **DC OUTPUT ADJ. RANGE** DC output voltage (or CH1 of multiple output models) can be adjusted between -5%~+10% rated output voltage by potential meter. ## **OVERLOAD PROTECTION** Fully protected against short circuit and output overload. The hiccup type protection will be activated at 120~160% rated load and recovers automatically after fault condition is removed. ## **OVER VOLTAGE PROTECTION** Provided on output channel 1 only at 115%~135% rated output voltage. Output will be shut down when this protection is activated. ## **OVER TEMPERATURE PROTECTION** When the temperature of TSW1 which detect on heat sink of power transistor reaches 95℃, This protection is activated. Then output will be shut down and recovers automatically after temperature goes down. ## **POWER GOOD / FAIL SIGNAL** TTL logic high for power good and TTL low for power fail. When the output voltage reaches 90% of rated value, a +5V TTL signal will be sent out with a 10~500ms delay; At least 1ms before the output voltage goes below 90% of the rated value, the TTL signal will be turned off. >100M Ohms for I/P-O/P, I/P-FG, O/P-FG by using 500VDC test voltage. |**EMI COMPLIANCE**|Compliance Level|Compliance Level|| |---|---|---|---| |EMI Specifications|BS EN/EN55011, Class B||| |Conducted & Radiation|EAC TP TC 020||| |Harmonic distortion|BS EN/|EN61000-3-2|| |Voltage flicker|BS EN/|EN61000-3-3|| |**EMS COMPLIANCE**|Compliance Level||| |EMS Specification|BS EN/|EN61000-4-2,|Level 3, 8KV| |ESD air|BS EN/|EN61000-4-2,|Level 2, 4KV| |ESD contact|BS EN/|EN61000-4-3,|Level 2, 3V/m| ||||Level 3, 10V/m| |RF field susceptibility|BS EN/|EN61000-4-4,|Level 2, 1KV/5KHz| ||||Level 3, 2KV/5KHz| |EFT(Electrical Fast Transient)/Burst|BS EN/|EN61000-4-5,|Level 4, 2KV/Line-Line| ||||4KV/Line-Earth| |Lightning/Surge|BS EN/|EN61000-4-6,|Level 2, 3Vrms/m| ||||Level 3, 10Vrms/m| |Conducted RF susceptibility|BS EN/|EN61000-4-8,|Level 2, 3A/m| ||||Level 3, 10A/m| |Magnetic field immunity|BS EN/|EN61000-4-11,|Compliance| |Voltage dip, interruption|BS EN/|ENV50204,|Level 2, 3V/m, 900MHz| |Digital phone carrier immunity|||Level 3, 10A/m, 900MHz| ||EAC TP TC 020||| ## **MTBF** 1679.6K hrs min. Telcordia SR-332 (Bellcore) ; 213.8K hrs min. MIL-HDBK-217F (25℃) **DIMENSION (L*W*H)** 177.8x107.2x35.5mm or 7"x4.22"x1.4" ## **PACKING** 0.66Kg; 24pcs/16.8Kg/1.17CUFT ## **REMOTE CONTROL** RC+/RC-:0 ~ 0.8V=power on; 4 ~ 10V=power off sink current<4~10mA _File Name:MPQ-200-SPEC 2022-03-18_ **MPQ - 200 series** 1~4 Output Medical Type ## **Output Chart** |**MODEL**|**OUTPUT**<br>**VOLTAGE**|**RATED**<br>**CURRENT**|**OUTPUT CURRENT**|**OUTPUT CURRENT**|**OUTPUT CURRENT**|**OUTPUT CURRENT**|**RIPPLE & NOISE **<br>**(Max.)**<br>**(Note 2)**|**VOLTAGE**<br>**TOLERANCE**<br>**(Note 3)**|**LINE**<br>**REGULATION **|**LOAD**<br> **REGULATION**|**EFFICIENCY**<br>**(typ.)**| |---|---|---|---|---|---|---|---|---|---|---|---| ||||**MINIMUM**<br>**LOAD**|**CONVECTION**<br>**(max.)**|**WITH FAN**<br>**(25CFM)**|**PEAK LOAD**<br>**(Note 4)**<br>**WITH 25CFM FAN**|||||| |**MPQ-200B**|**5V**|**15A**|**3A**|**12A**|**15A**|<br>**18A**|**80mVp-p**|±**2.0%**|±**0.5%**|±**1.0%**|**78%**| ||**12V**|**7A**|**0.7A**|**5.3A**|**7A**|**8.4A**|**120mVp-p**|±**8.0%**|±**1.0%**|±**5.0%**|| ||**-5V**|**2A**|**0A**|**1A**|**2A**|**2.4A**|**80mVp-p**|±**5.0%**|±**0.5%**|±**1.0%**|| ||**-12V**|**2A**|**0A**|**1A**|**2A**|**2.4A**|**80mVp-p**|±**5.0%**|±**0.5%**|±**1.0%**|| |**MPQ-200C**|**5V**|**15A**|**3A**|**12A**|**15A**|**18A**|**80mVp-p**|±**2.0%**|±**0.5%**|±**1.0%**|**78%**| ||**15V**|**5A**|**0.5A**|**4A**|**5A**|**6A**|**150mVp-p**|±**6.0%**|±**1.0%**|±**5.0%**|| ||**-5V**|**2A**|**0A**|**1A**|**2A**|**2.4A**|**80mVp-p**|±**5.0%**|±**0.5%**|±**1.0%**|| ||**-15V**|**2A**|**0A**|**1A**|**2A**|**2.4A**|**80mVp-p**|±**5.0%**|±**0.5%**|±**1.0%**|| |**MPQ-200D**|**5V**|**15A**|**3A**|**12A**|**15A**|**18A**|**80mVp-p**|±**2.0%**|±**0.5%**|±**1.0%**|**79%**| ||**24V**|**3A**|**0.3A**|**2.3A**|**3A**|**3.6A**|**180mVp-p**|±**8.0%**|±**1.0%**|±**5.0%**|| ||**12V**|**2A**|**0A**|**1A**|**2A**|**2.4A**|**80mVp-p**|±**5.0%**|±**0.5%**|±**1.0%**|| ||**-12V**|**2A**|**0A**|**1A**|**2A**|**2.4A**|**80mVp-p**|±**5.0%**|±**0.5%**|±**1.0%**|| |**MPQ-200F**|**5V**|**15A**|**3A**|**12A**|**15A**|**18A**|**80mVp-p**|±**2.0%**|±**0.5%**|±**1.0%**|**81%**| ||**24V**|**2.7A**|**0.3A**|**2.1A**|**2.7A**|**3.3A**|**180mVp-p**|±**8.0%**|±**1.0%**|±**5.0%**|| ||**15V**|**2A**|**0A**|**1A**|**2A**|**2.4A**|**80mVp-p**|±**5.0%**|±**0.5%**|±**1.0%**|| ||**-15V**|**2A**|**0A**|**1A**|**2A**|**2.4A**|**80mVp-p**|±**5.0%**|±**0.5%**|±**1.0%**|| **Notes :** ℃ > μ μ - - - http://www.meanwell.com - - - ℃℃ - ※: https://www.meanwell.com/serviceDisclaimer.aspx _File Name:MPQ-200-SPEC 2022-03-18_ **MPQ - 200 series** 1~4 Output Medical Type ## **Mechanical Specification** **==> picture [431 x 623] intentionally omitted <==** **----- Start of picture text -----**<br> 177.8[7"]<br>165.1[6.5"] 6.35[0.25"]<br>SVR1<br>LED 1 4<br>2 5 CN4<br>3 6<br>1<br>CN2<br>CN1<br>3 CN3<br>2<br>1<br>FG 16<br>4-ψ3.96[0.156"]<br>25CFM min.<br>FAN<br>3[0.118"] max.<br>AC Input Connector (CN1) : JST B3P-VH or equivalent DC Output Connector (CN4) : JS-2008-03*2 or equivalent<br>Pin No. Assignment Mating Housing Terminal Pin No. Assignment Mating Housing<br>1 AC/N 1 PG<br>JST VHR JST SVH-21T-P1.1<br>2 No Pin 2 RS-<br>or equivalent or equivalent<br>3 AC/L 3 GND JS-2007-03*2<br>4 RC+ or equivalent<br>DC Output Connector (CN2,3) : JST B8P-VH*2 or equivalent 5 RS+<br>Pin No. Assignment Mating Housing Terminal 6 RC-<br>1,2,3,4 V1<br>5~11 COM<br>12,13 V2 JST VHR JST SVH-21T-P1.1<br>14 V3 or equivalent or equivalent<br>15 No pin<br>16 V4<br>Derating Curve Static Characteristics<br>100<br>100<br>25CFM forced air cooling 90<br>80<br>80<br>60 Convection cooling 70<br>60<br>40<br>50<br>20<br>40<br>-20 0 10 20 30 40 50 60 70 (HORIZONTAL) 90 100 115 140 160 180 200 220 240<br>AMBIENT TEMPERATURE ( ℃ )<br>6.1[0.24"]<br>107.2[4.22"] 95.25[3.75"]<br>1<br>5c<br>m<br>35.5[1.4"]<br>LOAD (%) LOAD(%)<br>**----- End of picture text -----**<br> **==> picture [199 x 312] intentionally omitted <==** **----- Start of picture text -----**<br> DC Output Connector (CN4) : JS-2008-03*2 or equivalent<br>Pin No. Assignment Mating Housing Terminal<br>1 PG<br>2 RS-<br>3 GND JS-2007-03*2 JS-2007-T<br>4 RC+ or equivalent or equivalent<br>5 RS+<br>6 RC-<br>Static Characteristics<br>100<br>90<br>80<br>70<br>60<br>50<br>40<br>90 100 115 140 160 180 200 220 240 264<br>INPUT VOLTAGE (V) 60Hz<br>LOAD(%)<br>**----- End of picture text -----**<br> _File Name:MPQ-200-SPEC 2022-03-18_
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →