Image not available
Illustrative purposes only
MPM-45-24ST
AC/DC Enclosed Power Supply (PSU), 113 to 370VDC, ITE & Medical, 1 Outputs, 45.1 W, 24 VDC, 1.88 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: MPM-45 Series
- No. of Outputs: 1Outputs
- Output Power Max: 45.1W
- Input Voltage VAC: 80V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 1.88A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Medical
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 23.22 € |
| Current stock | 10+ |
| Lead time | 30 days |
45W AC-DC High Reliable PCB-Mount Green Medical Power Module **MPM-4 5** **series** ## + + TPTC004 ## ■ ## ■ No load power consumption<0.1W ℃ EMI Class B without additional components Isolation Class Ⅱ ## ■ a high efficiency up to 92.5%, Class Ⅱ | (no FG) double insulation, outstanding dissipation,2~5G anti-vibration μ ## ■ **==> picture [8 x 27] intentionally omitted <==** _File Name:MPM-45-SPEC 2020-01-15_ 45W AC-DC High Reliable PCB-Mount Green Medical Power Module **MPM - 45 series** ## **SPECIFICATION** |**OPERATING ALTITUDE Note.7**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED**<br>**POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**STORAGE TEMP.**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>20 ~ 90% RH non-condensing<br>-30 ~ +80<br>(Refer to "Derating Curve")<br>℃<br>-40 ~ +85℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)<br>**SAFETY STANDARDS**<br>**RIPPLE & NOISE (max.) Note.3**<br>**VOLTAGE TOLERANCE Note.4**<br>℃<br>μ<br>μ<br>℃<br>℃<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 8)**<br>**PROTECTION**<br>I/P-O/P:4KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>IEC60601-1, EN60601-1,<br>UL ANSI/AAMI ES60601-1(3.1 version), CAN/CSA-C22 3 Edition approved;<br>rd<br>EAC TP TC 004,<br>Design refer to EN60335-1(by request)<br>**LEAKAGE CURRENT (max.) Note.6**<br>**ISOLATION LEVEL**<br>Primary-Secondary: 2xMOPP<br>**Parameter**<br>**Parameter**<br>ESD<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>**Standard**<br>EN55011 (CISPR11)<br>EN55011 (CISPR11)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Class B<br>Class B<br>Class A<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>EN60601-1-2<br>Level 4, 15KV air ; Level 4, 8KV contact<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>**SOLDERING TEMPERATURE**<br>260<br>5<br>/10sec.max.<br>℃± ℃<br>1000ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load<br>50ms/230VAC 12ms/115VAC at full load<br>80 ~ 264VAC 113 ~ 370VDC<br>47 ~ 63Hz<br>88%<br>91.5%<br>92.5%<br>12.6 ~ 16.2V<br>92.5%<br>15.8 ~ 20.3V<br>92%<br>25.2 ~ 32.4V<br>50.4 ~ 64.8V<br>1.2A/115VAC 0.6A/230VAC<br>COLD START<br>30A/115VAC 60A/230VAC<br>115% ~ 135% rated output power<br>5.3 ~ 7.2V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>±1.0%<br>±0.5%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±2.0%<br>±2.0%<br>±2.0%<br>±2.0%<br>±2.0%<br>80mVp-p<br>120mVp-p<br>120mVp-p<br>200mVp-p<br>240mVp-p<br>12V<br>15V<br>24V<br>48V<br>8A<br>3.75A<br>3A<br>1.88A<br>0.94A<br>40W<br>45W<br>45W<br>45.1W<br>45.1W<br>**MPM-45-5**<br>**MPM-45-12**<br>**MPM-45-15**<br>**MPM-45-24**<br>**MPM-45-48**<br>5V<br>Touch current <100 A/264VAC<br>μ<br>8.8A<br>4.13A<br>3.3A<br>2.1A<br>1.05A<br>44W<br>49 5W<br>.<br>49 5W<br>.<br>50 4W<br>.<br>50.4W<br>Level 3, 1KV/Line-Line<br>Level 4, 30A/m<br>Level 3, 10V<br>Level 3, 2KV<br>Level 3, 10V/m( 80MHz~2.7GHz )<br>Table 9, 9~28V/m( 385MHz~5.78GHz )<br>RF field susceptibility<br>EFT bursts<br>Surge susceptibility<br>Conducted susceptibility<br>Magnetic field immunity<br>Voltage dip, interruption<br>Protection type : Shut down o/p voltage, re-power on to recover<br>PCB mounting style : 87*52*29.5mm (L*W*H) Screw terminal style : 109*52*33.5mm (L*W*H)<br>PCB mounting style : 0.185Kg;60pcs/12.1Kg/0.97CUFT<br>Screw terminal style :0.206Kg;50pcs/11.3Kg/0.55CUFT<br>4000 meters / OVCⅡ<br>B<br>:10 ~ 500Hz, G 10min./1cycle, period for 60min.<br>lank<br>2<br>each along X, Y, Z axes<br>ST:10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>563.44Khrs min. MIL-HDBK-217F (25<br>); 1530.14Khrs min.<br>Telcordia TR/SR-332 (Bellcore) (25<br>)<br>℃<br>℃<br>**CURRENT**<br>**OVER TEMPERATURE**<br>Protection type : Shut down o/p voltage, re-power on to recover<br>**Peak(10 sec.)**<br>**Convection**<br>**Convection**<br>**Peak(10 sec.)Note.2**<br>Re~~GG~~<br>~~ss~~<br>Q<br>Ge<br>GG<br>Re<br>~~GG~~<br>~~GG~~<br>es~~GC~~<br>~~GG~~<br>~~GG~~<br>~~GO~~<br>a<br>~~a~~<br>~~ee~~<br>a~~ee~~<br>a~~ee~~<br>RR ~~Ce~~<br>~~|~~<br>~~Bt~~<br>tt<br>_<br>a<br>Re<br>Re<br>a<br>a<br>~~ReCe~~<br>~~PO~~<br>a<br>a<br>Re<br>~~ReGO~~<br>~~DC~~<br>~~GO~~<br>~~GO~~<br>~~GG~~<br>~~Ce~~<br>~~eG~~<br>~~eG~~<br>~~GO~~<br>~~GC~~<br>~~Ge~~<br>~~GC~~<br>aa<br>a<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.<br>3. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>f& 47<br>f parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. Touch current was measured from primary input to DC output.<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>8. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still<br>meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Wwww.meanwell.com)|**OPERATING ALTITUDE Note.7**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED**<br>**POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**STORAGE TEMP.**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>20 ~ 90% RH non-condensing<br>-30 ~ +80<br>(Refer to "Derating Curve")<br>℃<br>-40 ~ +85℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)<br>**SAFETY STANDARDS**<br>**RIPPLE & NOISE (max.) Note.3**<br>**VOLTAGE TOLERANCE Note.4**<br>℃<br>μ<br>μ<br>℃<br>℃<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 8)**<br>**PROTECTION**<br>I/P-O/P:4KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>IEC60601-1, EN60601-1,<br>UL ANSI/AAMI ES60601-1(3.1 version), CAN/CSA-C22 3 Edition approved;<br>rd<br>EAC TP TC 004,<br>Design refer to EN60335-1(by request)<br>**LEAKAGE CURRENT (max.) Note.6**<br>**ISOLATION LEVEL**<br>Primary-Secondary: 2xMOPP<br>**Parameter**<br>**Parameter**<br>ESD<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>**Standard**<br>EN55011 (CISPR11)<br>EN55011 (CISPR11)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Class B<br>Class B<br>Class A<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>EN60601-1-2<br>Level 4, 15KV air ; Level 4, 8KV contact<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>**SOLDERING TEMPERATURE**<br>260<br>5<br>/10sec.max.<br>℃± ℃<br>1000ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load<br>50ms/230VAC 12ms/115VAC at full load<br>80 ~ 264VAC 113 ~ 370VDC<br>47 ~ 63Hz<br>88%<br>91.5%<br>92.5%<br>12.6 ~ 16.2V<br>92.5%<br>15.8 ~ 20.3V<br>92%<br>25.2 ~ 32.4V<br>50.4 ~ 64.8V<br>1.2A/115VAC 0.6A/230VAC<br>COLD START<br>30A/115VAC 60A/230VAC<br>115% ~ 135% rated output power<br>5.3 ~ 7.2V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>±1.0%<br>±0.5%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±2.0%<br>±2.0%<br>±2.0%<br>±2.0%<br>±2.0%<br>80mVp-p<br>120mVp-p<br>120mVp-p<br>200mVp-p<br>240mVp-p<br>12V<br>15V<br>24V<br>48V<br>8A<br>3.75A<br>3A<br>1.88A<br>0.94A<br>40W<br>45W<br>45W<br>45.1W<br>45.1W<br>**MPM-45-5**<br>**MPM-45-12**<br>**MPM-45-15**<br>**MPM-45-24**<br>**MPM-45-48**<br>5V<br>Touch current <100 A/264VAC<br>μ<br>8.8A<br>4.13A<br>3.3A<br>2.1A<br>1.05A<br>44W<br>49 5W<br>.<br>49 5W<br>.<br>50 4W<br>.<br>50.4W<br>Level 3, 1KV/Line-Line<br>Level 4, 30A/m<br>Level 3, 10V<br>Level 3, 2KV<br>Level 3, 10V/m( 80MHz~2.7GHz )<br>Table 9, 9~28V/m( 385MHz~5.78GHz )<br>RF field susceptibility<br>EFT bursts<br>Surge susceptibility<br>Conducted susceptibility<br>Magnetic field immunity<br>Voltage dip, interruption<br>Protection type : Shut down o/p voltage, re-power on to recover<br>PCB mounting style : 87*52*29.5mm (L*W*H) Screw terminal style : 109*52*33.5mm (L*W*H)<br>PCB mounting style : 0.185Kg;60pcs/12.1Kg/0.97CUFT<br>Screw terminal style :0.206Kg;50pcs/11.3Kg/0.55CUFT<br>4000 meters / OVCⅡ<br>B<br>:10 ~ 500Hz, G 10min./1cycle, period for 60min.<br>lank<br>2<br>each along X, Y, Z axes<br>ST:10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>563.44Khrs min. MIL-HDBK-217F (25<br>); 1530.14Khrs min.<br>Telcordia TR/SR-332 (Bellcore) (25<br>)<br>℃<br>℃<br>**CURRENT**<br>**OVER TEMPERATURE**<br>Protection type : Shut down o/p voltage, re-power on to recover<br>**Peak(10 sec.)**<br>**Convection**<br>**Convection**<br>**Peak(10 sec.)Note.2**<br>Re~~GG~~<br>~~ss~~<br>Q<br>Ge<br>GG<br>Re<br>~~GG~~<br>~~GG~~<br>es~~GC~~<br>~~GG~~<br>~~GG~~<br>~~GO~~<br>a<br>~~a~~<br>~~ee~~<br>a~~ee~~<br>a~~ee~~<br>RR ~~Ce~~<br>~~|~~<br>~~Bt~~<br>tt<br>_<br>a<br>Re<br>Re<br>a<br>a<br>~~ReCe~~<br>~~PO~~<br>a<br>a<br>Re<br>~~ReGO~~<br>~~DC~~<br>~~GO~~<br>~~GO~~<br>~~GG~~<br>~~Ce~~<br>~~eG~~<br>~~eG~~<br>~~GO~~<br>~~GC~~<br>~~Ge~~<br>~~GC~~<br>aa<br>a<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.<br>3. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>f& 47<br>f parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. Touch current was measured from primary input to DC output.<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>8. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still<br>meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Wwww.meanwell.com)|**OPERATING ALTITUDE Note.7**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED**<br>**POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**STORAGE TEMP.**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>20 ~ 90% RH non-condensing<br>-30 ~ +80<br>(Refer to "Derating Curve")<br>℃<br>-40 ~ +85℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)<br>**SAFETY STANDARDS**<br>**RIPPLE & NOISE (max.) Note.3**<br>**VOLTAGE TOLERANCE Note.4**<br>℃<br>μ<br>μ<br>℃<br>℃<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 8)**<br>**PROTECTION**<br>I/P-O/P:4KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>IEC60601-1, EN60601-1,<br>UL ANSI/AAMI ES60601-1(3.1 version), CAN/CSA-C22 3 Edition approved;<br>rd<br>EAC TP TC 004,<br>Design refer to EN60335-1(by request)<br>**LEAKAGE CURRENT (max.) Note.6**<br>**ISOLATION LEVEL**<br>Primary-Secondary: 2xMOPP<br>**Parameter**<br>**Parameter**<br>ESD<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>**Standard**<br>EN55011 (CISPR11)<br>EN55011 (CISPR11)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Class B<br>Class B<br>Class A<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>EN60601-1-2<br>Level 4, 15KV air ; Level 4, 8KV contact<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>**SOLDERING TEMPERATURE**<br>260<br>5<br>/10sec.max.<br>℃± ℃<br>1000ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load<br>50ms/230VAC 12ms/115VAC at full load<br>80 ~ 264VAC 113 ~ 370VDC<br>47 ~ 63Hz<br>88%<br>91.5%<br>92.5%<br>12.6 ~ 16.2V<br>92.5%<br>15.8 ~ 20.3V<br>92%<br>25.2 ~ 32.4V<br>50.4 ~ 64.8V<br>1.2A/115VAC 0.6A/230VAC<br>COLD START<br>30A/115VAC 60A/230VAC<br>115% ~ 135% rated output power<br>5.3 ~ 7.2V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>±1.0%<br>±0.5%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±2.0%<br>±2.0%<br>±2.0%<br>±2.0%<br>±2.0%<br>80mVp-p<br>120mVp-p<br>120mVp-p<br>200mVp-p<br>240mVp-p<br>12V<br>15V<br>24V<br>48V<br>8A<br>3.75A<br>3A<br>1.88A<br>0.94A<br>40W<br>45W<br>45W<br>45.1W<br>45.1W<br>**MPM-45-5**<br>**MPM-45-12**<br>**MPM-45-15**<br>**MPM-45-24**<br>**MPM-45-48**<br>5V<br>Touch current <100 A/264VAC<br>μ<br>8.8A<br>4.13A<br>3.3A<br>2.1A<br>1.05A<br>44W<br>49 5W<br>.<br>49 5W<br>.<br>50 4W<br>.<br>50.4W<br>Level 3, 1KV/Line-Line<br>Level 4, 30A/m<br>Level 3, 10V<br>Level 3, 2KV<br>Level 3, 10V/m( 80MHz~2.7GHz )<br>Table 9, 9~28V/m( 385MHz~5.78GHz )<br>RF field susceptibility<br>EFT bursts<br>Surge susceptibility<br>Conducted susceptibility<br>Magnetic field immunity<br>Voltage dip, interruption<br>Protection type : Shut down o/p voltage, re-power on to recover<br>PCB mounting style : 87*52*29.5mm (L*W*H) Screw terminal style : 109*52*33.5mm (L*W*H)<br>PCB mounting style : 0.185Kg;60pcs/12.1Kg/0.97CUFT<br>Screw terminal style :0.206Kg;50pcs/11.3Kg/0.55CUFT<br>4000 meters / OVCⅡ<br>B<br>:10 ~ 500Hz, G 10min./1cycle, period for 60min.<br>lank<br>2<br>each along X, Y, Z axes<br>ST:10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>563.44Khrs min. MIL-HDBK-217F (25<br>); 1530.14Khrs min.<br>Telcordia TR/SR-332 (Bellcore) (25<br>)<br>℃<br>℃<br>**CURRENT**<br>**OVER TEMPERATURE**<br>Protection type : Shut down o/p voltage, re-power on to recover<br>**Peak(10 sec.)**<br>**Convection**<br>**Convection**<br>**Peak(10 sec.)Note.2**<br>Re~~GG~~<br>~~ss~~<br>Q<br>Ge<br>GG<br>Re<br>~~GG~~<br>~~GG~~<br>es~~GC~~<br>~~GG~~<br>~~GG~~<br>~~GO~~<br>a<br>~~a~~<br>~~ee~~<br>a~~ee~~<br>a~~ee~~<br>RR ~~Ce~~<br>~~|~~<br>~~Bt~~<br>tt<br>_<br>a<br>Re<br>Re<br>a<br>a<br>~~ReCe~~<br>~~PO~~<br>a<br>a<br>Re<br>~~ReGO~~<br>~~DC~~<br>~~GO~~<br>~~GO~~<br>~~GG~~<br>~~Ce~~<br>~~eG~~<br>~~eG~~<br>~~GO~~<br>~~GC~~<br>~~Ge~~<br>~~GC~~<br>aa<br>a<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.<br>3. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>f& 47<br>f parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. Touch current was measured from primary input to DC output.<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>8. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still<br>meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Wwww.meanwell.com)|**MPM-45-5**|**MPM-45-12**|**MPM-45-12**|**MPM-45-15**|**MPM-45-24**|**MPM-45-24**|**MPM-45-48**| |---|---|---|---|---|---|---|---|---|---| ||**DC VOLTAGE**<br>Re||5V<br>~~GG~~|12V<br>~~GG~~<br>Q||15V<br>~~GG~~|24V<br>~~GG~~||48V<br>~~GG~~| ||**RATED**<br>**POWER**<br>**RIPPLE & NOISE (max.) Note.3**<br>**CURRENT**<br>**Peak(10 sec.)**<br>**Convection**<br>**Convection**<br>**Peak(10 sec.)Note.2**<br>Re<br>~~ss~~<br>Ge<br>Re<br>es<br>~~GG~~|**Peak(10 sec.)**<br>Re<br>~~ss~~|8.8A<br>~~GG~~<br>~~ss~~|4.13A<br>~~GG~~<br>~~ss~~<br>Q||3.3A<br>~~GG~~<br>~~ss~~|2.1A<br>~~GG~~<br>~~ss~~||1.05A<br>~~GG~~<br>~~ss~~| |||**Convection**<br>~~ss~~<br>Ge<br>Re|8A<br>~~ss~~<br>Ge<br>~~GG~~|3.75A<br>~~ss~~<br>Q<br>Ge<br>~~GG~~||3A<br>~~ss~~<br>GG<br>~~GG~~|1.88A<br>~~ss~~<br>GG<br>~~GG~~||0.94A<br>~~ss~~<br>~~GG~~| |||**Peak(10 sec.)Note.2**<br>Ge<br>Re<br>es|44W<br>Ge<br>~~GG~~<br>~~GC~~|49 5W<br>.<br>Ge<br>~~GG~~<br>~~GC~~||49 5W<br>.<br>GG<br>~~GG~~<br>~~GC~~|50 4W<br>.<br>GG<br>~~GG~~<br>~~GC~~||50.4W<br>~~GG~~<br>~~GC~~| |||**Convection**<br>Re<br>es|40W<br>~~GG~~<br>~~GC~~|45W<br>~~GG~~<br>~~GC~~||45W<br>~~GG~~<br>~~GC~~|45.1W<br>~~GG~~<br>~~GC~~||45.1W<br>~~GG~~<br>~~GC~~| ||||80mVp-p<br>~~GC~~<br>~~GG~~|120mVp-p<br>~~GC~~<br>~~GG~~||120mVp-p<br>~~GC~~<br>~~GG~~|200mVp-p<br>~~GC~~<br>~~GG~~||240mVp-p<br>~~GC~~<br>~~GG~~| ||**VOLTAGE TOLERANCE Note.4**<br>~~GG~~||±2.0%<br>~~GG~~|±2.0%<br>~~GG~~||±2.0%<br>~~GG~~|±2.0%<br>~~GG~~||±2.0%<br>~~GG~~| ||**LINE REGULATION**<br>~~GG~~<br>~~GO~~||±0.5%<br>~~GG~~<br>~~GO~~|±0.5%<br>~~GG~~<br>~~GO~~||±0.5%<br>~~GG~~<br>~~GO~~|±0.5%<br>~~GG~~<br>~~GO~~||±0.5%<br>~~GG~~<br>~~GO~~| ||**LOAD REGULATION**<br>a||±1.0%|±1.0%||±0.5%|±0.5%||±0.5%| ||**SETUP, RISE TIME**<br>a||1000ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load||||||| ||**HOLD UP TIME (Typ.)**<br>~~a~~||50ms/230VAC 12ms/115VAC at full load||||||| ||**VOLTAGE RANGE**<br>**Note.5**<br>~~a~~<br>~~ee~~<br>a||80 ~ 264VAC 113 ~ 370VDC<br>~~ee~~<br>||||||| ||**FREQUENCY RANGE**<br>a||47 ~ 63Hz<br>||||||| ||**EFFICIENCY (Typ.)**<br>a~~ee~~<br>a||88%<br>~~ee~~<br>|91.5%<br>~~ee~~<br>||92.5%<br>~~ee~~<br>|92.5%<br>~~ee~~<br>||92%<br>~~ee~~<br>| ||**AC CURRENT (Typ.)**<br>a||1.2A/115VAC 0.6A/230VAC<br>||||||| ||**INRUSH CURRENT (Typ.)**<br>a~~ee~~<br>RR||COLD START<br>30A/115VAC 60A/230VAC<br>~~ee~~<br>~~Ce~~||||||| ||**LEAKAGE CURRENT (max.) Note.6**<br>RR||Touch current <100 A/264VAC<br>μ<br>~~Ce~~||||||| ||**OVERLOAD**<br>RR <br>~~Bt~~||115% ~ 135% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br> ~~Ce~~<br>~~|~~<br>~~Bt~~<br>tt<br>_||||||| ||**OVER VOLTAGE**<br>~~Bt~~||12.6 ~ 16.2V<br>15.8 ~ 20.3V<br>25.2 ~ 32.4V<br>50.4 ~ 64.8V<br>5.3 ~ 7.2V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>~~Bt~~<br>tt<br>_||||||| ||**OVER TEMPERATURE**<br>~~Bt~~<br>a<br>Re||Protection type : Shut down o/p voltage, re-power on to recover<br>~~Bt~~<br>tt<br>_||||||| ||**WORKING TEMP.**<br>a<br>Re<br>Re||-30 ~ +80<br>(Refer to "Derating Curve")<br>℃||||||| ||**WORKING HUMIDITY**<br>Re<br>Re||20 ~ 90% RH non-condensing||||||| ||**STORAGE TEMP.**<br>Re<br>a<br>a||-40 ~ +85℃||||||| ||**TEMP. COEFFICIENT**<br>a<br>~~Re~~||±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)<br>~~Ce~~||||||| ||**SOLDERING TEMPERATURE**<br>a<br>~~Re~~||260<br>5<br>/10sec.max.<br>℃± ℃<br>~~Ce~~||||||| ||**VIBRATION**<br>~~Re~~||B<br>:10 ~ 500Hz, G 10min./1cycle, period for 60min.<br>lank<br>2<br>each along X, Y, Z axes<br>ST:10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>~~Ce~~<br>~~PO~~||||||| ||**OPERATING ALTITUDE Note.7**<br>a||4000 meters / OVCⅡ||||||| ||**SAFETY STANDARDS**<br>a<br>a||IEC60601-1, EN60601-1,<br>UL ANSI/AAMI ES60601-1(3.1 version), CAN/CSA-C22 3 Edition approved;<br>rd<br>EAC TP TC 004,<br>Design refer to EN60335-1(by request)||||||| ||**ISOLATION LEVEL**<br>a<br>Re||Primary-Secondary: 2xMOPP||||||| ||**WITHSTAND VOLTAGE**<br>a<br>Re<br>~~Re~~||I/P-O/P:4KVAC<br>~~GO~~||||||| ||**ISOLATION RESISTANCE**<br>Re<br>~~Re~~||I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>~~GO~~||||||| ||**MTBF**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>~~Re~~<br>aa||**Parameter**<br>~~GO~~<br>~~DC~~||**Standard**<br>~~GO~~<br>~~DC~~|||**Test Level / Note**<br>~~GO~~<br>~~DC~~|| ||||Conducted<br>~~DC~~<br>~~GO~~||EN55011 (CISPR11)<br>~~DC~~<br>~~GO~~|||Class B<br>~~DC~~<br>~~GO~~|| ||||Radiated<br>~~GO~~<br>~~GO~~||EN55011 (CISPR11)<br>~~GO~~<br>~~GO~~|||Class B<br>~~GO~~<br>~~GO~~|| ||||Harmonic Current<br>~~GO~~<br>~~GG~~||EN61000-3-2<br>~~GO~~<br>~~GG~~|||Class A<br>~~GO~~<br>~~GG~~|| ||||Voltage Flicker<br>~~GG~~<br>~~Ce~~||EN61000-3-3<br>~~GG~~<br>~~Ce~~|||-----<br>~~GG~~<br>~~Ce~~|| ||||EN60601-1-2<br>~~Ce~~<br>~~eG~~||||||| ||||**Parameter**<br>~~eG~~<br>~~eG~~||**Standard**<br>~~eG~~<br>~~eG~~|||**Test Level / Note**<br>~~eG~~<br>~~eG~~|| ||||ESD<br>~~eG~~||EN61000-4-2<br>~~eG~~|||Level 4, 15KV air ; Level 4, 8KV contact<br>~~eG~~|| ||||RF field susceptibility||EN61000-4-3|||Level 3, 10V/m( 80MHz~2.7GHz )<br>Table 9, 9~28V/m( 385MHz~5.78GHz )|| ||||EFT bursts<br>~~GO~~||EN61000-4-4<br>~~GO~~|||Level 3, 2KV<br>~~GO~~|| ||||Surge susceptibility<br>~~GC~~<br>~~Ge~~||EN61000-4-5<br>~~GC~~<br>~~Ge~~|||Level 3, 1KV/Line-Line<br>~~GC~~<br>~~Ge~~|| ||||Conducted susceptibility<br>~~Ge~~<br>~~GC~~||EN61000-4-6<br>~~Ge~~<br>~~GC~~|||Level 3, 10V<br>~~Ge~~<br>~~GC~~|| ||||Magnetic field immunity<br>~~GC~~||EN61000-4-8<br>~~GC~~|||Level 4, 30A/m<br>~~GC~~|| ||||Voltage dip, interruption||EN61000-4-11|||>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods|| ||||563.44Khrs min. MIL-HDBK-217F (25<br>); 1530.14Khrs min.<br>Telcordia TR/SR-332 (Bellcore) (25<br>)<br>℃<br>℃||||||| ||**DIMENSION**<br>aa<br>a||PCB mounting style : 87*52*29.5mm (L*W*H) Screw terminal style : 109*52*33.5mm (L*W*H)||||||| ||**PACKING**<br>℃<br>μ<br>μ<br>℃<br>℃<br>PCB mounting style : 0.185Kg;60pcs/12.1Kg/0.97CUFT<br>Screw terminal style :0.206Kg;50pcs/11.3Kg/0.55CUFT<br>a<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.<br>3. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>f& 47<br>f parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. Touch current was measured from primary input to DC output.<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>8. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still<br>meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Wwww.meanwell.com)||||||||| _File Name:MPM-45-SPEC 2020-01-15_ 45W AC-DC High Reliable PCB-Mount Green Medical Power Module **MPM-45 series** ## **Block Diagram** **==> picture [488 x 598] intentionally omitted <==** **----- Start of picture text -----**<br> fosc : 70KHz<br>RECTIFIERS RECTIFIERS<br>EMI POWER +Vo<br>I/P & &<br>FILTER FILTER SWITCHING FILTER -Vo<br>DETECTION<br>CIRCUIT<br>PWM<br>O.L.P.<br>CONTROL<br>O.V.P.<br>Derating Curve<br>100 for others<br>for 5V<br>75<br>50<br>40<br>-30 -20 -10 0 10 20 30 40 50 55 60 70 80 (HORIZONTAL)<br>AMBIENT TEMPERATURE ( ℃ )<br>Output Derating VS Input Voltage<br>100<br>90<br>80<br>70<br>60<br>50<br>40<br>80 95 100 115 120 140 160 180 200 220 240 264<br>INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%)<br>LOAD (%)<br>**----- End of picture text -----**<br> _File Name:MPM-45-SPEC 2020-01-15_ 45W AC-DC High Reliable PCB-Mount Green Medical Power Module **MPM-45 series** ## **Mechanical Specification** **==> picture [429 x 580] intentionally omitted <==** **----- Start of picture text -----**<br> Case No.IRM60 Unit:mm<br>87<br>5.7 76 29.5<br>3.5±1mm<br>AC/N<br>AC/L<br>BOTTOM<br>VIEW<br>-Vo<br>+Vo<br>AC/L, AC/N P/N diameter:1ψ<br>+Vo, -Vo P/N diameter:2ψ<br>(MPM-45-xxST))<br>52 33.5<br>33<br>6.7<br>7.5<br>4-ψ3.5 AC/N AC/L<br>TOP<br>VIEW<br>-Vo -Vo+Vo+Vo<br>5 5 5<br>5<br>6.75<br>40.75<br>52<br>5.5<br>98 109<br>ψ<br>2-1<br>ψ<br>2-2<br>**----- End of picture text -----**<br> **==> picture [126 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> � PCB mounting style (MPM-45)<br>**----- End of picture text -----**<br> ## � **Screw terminal style (MPM-45-xxST))** ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:MPM-45-SPEC 2020-01-15_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →