Image not available
Illustrative purposes only
MPDCD3-B
SOLID STATE RELAYS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SENSATA-CRYDOM / PARTNER STOCK
- Product type:
- SVHC: To Be Advised
- Product Range: MP Series
| Delivery and price | |
|---|---|
| Units per pack | 6 |
| Price | 74.29 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **| MP SERIES**
## PCB MOUNT SOLID STATE RELAYS
## Features
- SIP SSR
- Ratings up to 4A @ 280 VAC or 3A @ 60 VDC
- TRIAC (AC) or Transistor (DC) output
- DC control
- Normally open (AC or DC) or normally closed output (DC only)
- CE complaint to EN60950-1
## **PRODUCT SELECTION** @
**Control Voltage 3A 3A 4A 3A** 3-32 VDC MP120D3 MP240D3 MP240D4 MPDCD3
## **SPECIFICATIONS** ~~e~~
AC Output[(A)]
|**Description**<br>~~I~~|**MP120D3**<br>~~I~~|**MP240D3**<br>~~I~~|**MP240D4**<br>~~I~~|
|---|---|---|---|
|**Operating Voltage (47-63 Hz) [Vrms]**<br>~~|~~<br>~~pO~~|12-140<br>~~|~~|24-280<br>~~|~~|24-280<br>~~|~~<br>~~—~~|
|**Transient Overvoltage [Vpk]**<br>~~pO~~|400|600|600<br>~~—~~|
|**Maximum Off-State Leakage Current @ Rated Voltage [mA]**<br>~~pO~~<br>|~~>~~<br>~~See~~|5<br>~~See~~|5<br>~~|~~|5<br>~~—~~<br>~~|~~|
|**Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec](B)**<br>~~>~~<br>~~See~~|200<br>~~See~~|200<br>~~|~~|200<br>~~|~~|
|**Maximum Load Current [Arms](C)**<br>~~>~~<br>~~See~~<br>~~|~~<br>||3<br>~~See~~<br>~~eee~~|3<br>~~|~~<br>~~|~~|4<br>~~|~~<br>~~|~~|
|**Minimum Load Current [Arms]**<br>~~>~~<br>||0.02<br>~~eee~~|0.02<br>~~|~~|0.02<br>~~|~~|
|**Maximum Surge Current (16.6ms) [Apk]**<br>||90<br>~~eee~~|90<br>~~|~~<br>~~—~~|130<br>~~|~~<br>~~—~~|
|**Maximum On-State Voltage Drop @ Rated Current [Vpk]**<br>~~pO~~|1.6|1.6<br>~~—~~|1.6<br>~~—~~|
|**Maximum I² t for Fusing (50/60 Hz, 1/2 cycle) [A² sec]**<br>~~|~~|36|36<br>~~—~~|72<br>~~—~~|
|**Minimum Power Factor (with Maximum Load)**<br>~~|~~<br>~~a~~|0.5<br>~~a~~|0.5<br>~~—~~<br>~~a~~|0.5<br>~~—~~<br>~~a~~|
Page 1
Copyright © 2024 Sensata Technologies, Inc.
www.sensata.com
## DC Output[(A)]
**==> picture [541 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
Description MPDCD3<br>Operating Voltage [Vdc] 3-60<br>Maximum Load Current [Adc] 3<br>Minimum Load Current [mA] 0.02<br>Maximum Surge Current for 1 second [Adc] 5<br>Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.5<br>Maximum Off-State Leakage Current @ Rated Voltage [mA] 1.0<br>**----- End of picture text -----**<br>
## Input[(A)]
**==> picture [541 x 120] intentionally omitted <==**
**----- Start of picture text -----**<br>
Description AC Output DC Output DC Output (-B)<br>Control Voltage Range [VDC] 3-32 3-32 3-32<br>Must Turn-On Voltage [VDC] 3.0 3.0 1.0<br>Must Turn-Off Voltage [VDC] 1.0 1.0 3.0<br>Typical Input Current @ 2 VDC [mA] 23 23 23<br>Nominal Input Impedance [0hm] 1500 1500 1500<br>Maximum Turn-On Time [msec] 1/2 Cycle 0.1 0.1<br>Maximum Turn-Off Time [msec] 1/2 Cycle 0.1 0.1<br>**----- End of picture text -----**<br>
## General[(A)]
|**Description**|**Parameters**|
|---|---|
|**Dielectric Strength, Input/Output (50/60 Hz)**|4000 Vrms|
|**Minimum Insulation Resistance (@ 500 V DC)**|109Ohms|
|**Maximum Capacitance, Input/Output**|8 pF|
|**Ambient Operating Temperature Range**|-40 to 80˚C|
|**Ambient Storage Temperature Range**|-40 to 125˚C|
|**Weight (typical)**|0.7 oz (20g)|
|**Encapsulation**|Thermally Conductive Epoxy|
|**Enclosure and PCB**|Meets the requirements of IEC60335-1|
## **EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAMS**
**==> picture [452 x 193] intentionally omitted <==**
**----- Start of picture text -----**<br>
TRIGGER<br>CIRCUIT<br>+ +<br>4 3 2 1 4 13 2 1<br>-D DC -DC +DC<br>B A<br>(3)<br>B A<br>AC AC<br>Load can be wired in location A or B<br>-DC +DC<br>CIRCUIT CONTROL<br>LOAD LOAD<br>LOAD LOAD<br>**----- End of picture text -----**<br>
Page 2
Copyright © 2024 Sensata Technologies, Inc.
www.sensata.com
## **THERMAL DERATE INFORMATION**
**==> picture [66 x 27] intentionally omitted <==**
**----- Start of picture text -----**<br>
MP240D4 MP120D3<br>MP240D3<br>MPDCD3<br>MPDCD3-B<br>**----- End of picture text -----**<br>
**==> picture [205 x 188] intentionally omitted <==**
**----- Start of picture text -----**<br>
4.0<br>ecnndennnnepennnetoes, . Se.<br>Se,%,.<br>Se,.Se, .<br>3.0 Se,.oaBe..Se,<br>2.0 Se,sBe, .Se,.ary +<br>1.0<br>0<br>20 40 60 80<br>Ambient Temperature (”C)<br>Load Current (Amps)<br>**----- End of picture text -----**<br>
## **MECHANICAL SPECIFICATIONS**
Tolerances: ±0.02 in / 0.5 mm All dimensions are in inches [millimeters]
**==> picture [219 x 153] intentionally omitted <==**
**----- Start of picture text -----**<br>
BOTTOM VIEW<br>ie) 9) oO 9O<br>1 draft<br>top to base<br>1.00 0.25<br>(25.4) (.64)<br>LOAD CONTROL<br>.25 TYP. (6.35)<br>12 34<br>{ — _— (17.8).70 —- ) _ Je (5.1)0.20 (4.1).015 | .40<br>.040 (1.0) DIA. 1.10 (10.2)<br>(4 PLACES) — _—___ (27.9) (43.1)1.70 — _<br>**----- End of picture text -----**<br>
Page 3
Copyright © 2024 Sensata Technologies, Inc.
www.sensata.com
## **ORDERING OPTIONS**
Example : MPDCD3-B
**MP DC D 3 -B Series MP Operating Voltage**
**120:** 12-140 VAC **240:** 24-280 VAC **DC:** 3-60 VDC
## **Control Voltage**
**D:** 3-32 VDC
## **Rated Load Current**
**3:** 3 Amps **4:** 4 Amps **Output Function/Type Blank:** Normally Open Required for valid part number **-B:** Normally Closed (DC only) For options only and not required for valid part number
## **GENERAL NOTES**
> (1) All parameters at 25 °C unless otherwise specified
> (2) Off-State dv/dt test method per EIA/NARM standard RS-443. paragraph 13.11.1
> (3) Inductive loads should be diode suppressed
## **AGENCY APPROVALS & CERTIFICATIONS**
Designed in accordance with the requirements of IEC 62314
E116950 (120D3, 240D3, LR 81689 (120D3, 240D4 and DCD3 only) 240D3 and 204D4 only) (AC output only)
## **WARNINGS**
RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
**==> picture [278 x 52] intentionally omitted <==**
**----- Start of picture text -----**<br>
• The product’s side panels may be hot, allow the product to cool before touching<br>• Follow proper mounting instructions including torque values<br>• Do not allow liquids or foreign objects to enter this product<br>Failure to follow these instructions can result in serious injury, or equipment damage.<br>HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH<br>**----- End of picture text -----**<br>
**==> picture [233 x 27] intentionally omitted <==**
**----- Start of picture text -----**<br>
• Disconnect all power before installing or working with this equipment<br>• Verify all connections and replace all covers before turning on power<br>Failure to follow these instructions will result in death or serious injury.<br>**----- End of picture text -----**<br>
Page 4
Datasheets provided by Sensata Technologies, Inc., its subsidiaries and/or affiliates (“Sensata”) are solely intended to assist third parties
(“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation, and judgment in designing Buyer’s systems and products. Sensata datasheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular datasheet. Sensata may make corrections, enhancements, improvements, and other changes to its datasheets or components without notice. Buyers are authorized to use Sensata datasheets with the Sensata component(s) identified in each particular datasheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATASHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATASHEETS OR USE OF THE DATASHEETS, EXPRESS, IMPLIED, OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATASHEETS OR USE THEREOF.
All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com. SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY, AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA.
## **CONTACT US**
## **Americas**
+1(800) 350 2727 sales.crydom@sensata.com
**Europe, Middle East & Africa** +44 (1202) 416170 ssr-info.eu@sensata.com **Asia Pacific** sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808
Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA
www.sensata.com
Rev. 07/09/2024 ECN 21026 FDE-07-01 Rev. B
Copyright © 2024 Sensata Technologies, Inc.
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →