MLH500PSB06A
Pressure Sensor, 500 psi, Ratiometric, Sealed Gauge, 5 VDC, 1/8
- Manufacturer: HONEYWELL
- Product type: Pressure Transducers
- Port Style: 1/8" - 27 NPT
- Product Range: MLH Series
- Sensor Output: Ratiometric
- Supply Current: 4mA
- Voltage Rating: 5VDC
- Operating Pressure Max: 500psi
- Pressure Measurement Type: Sealed Gauge
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 87.11 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Heavy Duty Pressure Transducers 008118** MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi Issue 8 ## **Datasheet** ## **FEATURES** - All metal wetted parts allow for potential use in wide variety of fluid applications - No internal elastomeric seals mean no O-ring compatibility issues - Amplified outputs reduce the need to purchase external amplifiers - Input reverse voltage protection guards against mis-wiring - Less than 2 ms response time provides more accurate, high speed measurement - Rated IP65 or better for protection from most harsh environments ## **DESCRIPTION** ## **POTENTIAL APPLICATIONS** The MLH Series Heavy Duty Pressure Transducers combine Application Specific Integrated Circuit (ASIC) technology with a media-isolated, metal diaphragm design. This digitally compensated transducer offers value and performance, making it a suitable pressure sensing solution for demanding applications. Fully temperature compensated, calibrated and amplified, the MLH Series is available in pressure ranges of 6 bar to 550 bar | 50 psi to 8,000 psi. The MLH Series provides ±0.25% full scale accuracy Best Fit Straight Line (BFSL) and a TEB (Total Error Band) as low as 2% over a temperature range of -40 °C to 125 °C [-40 °F to 257 °F]. Industry standard electrical connectors and pressure ports are offered for enhanced reliability and user flexibility. - Industrial: Compressors, cylinder tank pressure, HVAC, hydraulics, oil and gas, refrigeration, water distribution - Transportation: Multiple applications including braking and alternative fuels - Medical: Anesthesia delivery machines, blood analyzers, chemistry analyzers, gas chromatography, oxygen concentrators, and ventilators ## **PORTFOLIO** The MLH Series joins the PX3 Series, PX2 Series, SPT Series, 13 mm Series and 19 mm Series heavy duty pressure transducers. The MLH Series has six standard output options: A. 0.5 Vdc to 4.5 Vdc ratiometric from 5 Vdc excitation B. 4 mA to 20 mA C. 1 Vdc to 6 Vdc regulated D. 0.25 Vdc to 10.25 Vdc regulated E. 0.5 Vdc to 4.5 Vdc regulated G. 1 Vdc to 5 Vdc regulated Safety and Productivity Solutions **Heavy Duty Pressure Transducers** MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi **Table 1. Pressure Range Specifications[1] (At 25** ° **C [77** ° **F] and at rated excitation unless otherwise specified.)** **==> picture [542 x 258] intentionally omitted <==** **----- Start of picture text -----**<br> bar psi<br>Operating Proof Burst Operating Proof Burst<br>Pressure Pressure Pressure Pressure Pressure Pressure<br>6 18 60 50 150 500<br>10 30 100 100 300 1000<br>16 48 160 150 450 1500<br>25 75 250 200 600 2000<br>40 80 400 250 750 2500<br>60 120 600 300 900 3000<br>100 200 1000 500 1500 5000<br>160 320 1600 1000 2000 10000<br>250 500 2068 2000 4000 20000<br>350 700 2068 3000 6000 30000<br>500 750 2068 5000 7500 30000<br>550 825 2068 8000 12000 30000<br>**----- End of picture text -----**<br> 1 Comparable metric units follow same proof and burst specifications. **Table 2. Electrical Specifications** **==> picture [542 x 265] intentionally omitted <==** **----- Start of picture text -----**<br> Output Signal<br>Characteristic Ratiometric Current Regulated Regulated Regulated Regulated<br>(A) (B) (C) (D) (E) (G)<br>Zero output 0.5 Vdc 4 mA 1 Vdc 0.25 Vdc 0.5 Vdc 1 Vdc<br>10 Vdc<br>Full scale 4 Vdc 16 mA 5 Vdc 4 Vdc 4 Vdc<br>(0.25 Vdc to<br>span (FSS) (0.5 Vdc to 4.5 Vdc) (4 mA to 20 mA) (1 Vdc to 6 Vdc) (0.5 Vdc to 4.5 Vdc) (1 Vdc to 5 Vdc)<br>10.25 Vdc)<br>5 Vdc 9.5 Vdc to 8 Vdc to 14 Vdc to 7 Vdc to 8 Vdc to<br>Excitation<br>(6 Vdc max.) [1] 30 Vdc [2] 30 Vdc [2] 30 Vdc [2] 30 Vdc [2] 30 Vdc [2]<br>Supply 4 mA typ., 5 mA typ., 5 mA typ., 5 mA typ., 5 mA typ.,<br>N/A<br>current 8 mA max. 17 mA max. 17 mA max. 17 mA max. 17 mA max.<br>Source<br>1 mA N/A 1 mA 1 mA 1 mA 1 mA<br>(nominal)<br>Sink 1 mA A1 mA 1 mA 1 mA 1 mA<br>N/A<br>(nominal at zero output at zero output at zero output at zero output at zero output<br>Supply<br>90 dB 90 dB 90 dB 90 dB 90 dB 90 dB<br>rejection ratio<br>Output<br>25 Ohm max. N/A 25 Ohm max. 25 Ohm max. 25 Ohm max. 25 Ohm max.<br>impedance<br>**----- End of picture text -----**<br> 1 Maintains ratiometricity at 5 ±0.25 Vdc excitation. Product can tolerate 6 Vdc excitation without damage. 2 See Figures 1 and 2 for more information regarding maximum excitation voltage vs. operating temperature. **2** Safety and Productivity Solutions **Heavy Duty Pressure Transducers** MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi **Table 3. Environmental and Mechanical Specifications** **==> picture [542 x 214] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Parameter<br>Material in contact with media:<br> port stainless steel 304L<br> diaphragm Haynes 214 alloy<br>Housing material black plastic – Amodel AS-4133 HS – PPA<br>Weight (typical for Metri-Pack 150 and 1/8 NPT<br>57.0 g [2.0 oz]<br>pressure port types)<br>Shock 100 g peak [11 ms]<br>MIL-STD-810C, Figure 514.2-5, Curve AK, Table 514.2-V,<br>Vibration<br>Random Vibration Test (overall g rms = 20.7 min.)<br>Compensated and operating temperature range:<br> 0.5 Vdc to 4.5 Vdc ratiometric output -40 °C to 125 °C [-40 °F to 257 °F]<br> all regulated and 4 mA to 20 mA outputs -40 °C to 125 °C [-40 °F to 257 °F] (See Figures 1 and 2 for operating area details.)<br>Storage temperature range -40 °C to 125 °C [-40 °F to 257 °F]<br>Approvals RoHS, CE, UL Component Recognition for USA and Canada: File No. E258956<br>**----- End of picture text -----**<br> **Table 4. Performance Specifications (At 25 °C [77 °F] and under unless otherwise noted.)** **==> picture [543 x 232] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Parameter<br>Response time <2 ms<br>Accuracy [1] :<br> >100 psi ±0.25 %FSS<br> <100 psi ±0.50 %FSS<br>Total Error Band [2] :<br> Gage:<br> <300 psig ±3 %FSS<br> >300 psig ±2 %FSS<br> Sealed gage:<br> >300 psis ±2 %FSS<br> without L, M, P electrical connector types:<br> 100 psis to 299 psis (-40 °C to 85 °C [-40 °F to 185 °F]) ±3 %FSS<br> 100 psis to 299 psis (>85 °C to 125 °C [>185 °F to 257 °F]) ±10 %FSS<br> >300 psis (-40 °C to 125 °C [-40 °F to 257 °F]) ±2 %FSS<br> with L, M, P electrical connector types:<br> 100 psis to 299 psis (-40 °C to 65 °C [-40 °F to 149 °F]) ±10 %FSS<br> 100 psis to 299 psis (>65 °C to 125 °C [>149 °F to 257 °F]) ±15 %FSS<br> >300 psis (-40 °C to 65 °C [-40 °F to 149 °F]) ±5 %FSS<br> >300 psis (>65 °C to 125 °C [>149 °F to 257 °F]) ±15 %FSS<br>**----- End of picture text -----**<br> 1 Includes pressure non-linearity (BFSL), pressure hysteresis and non-repeatability. Thermal errors are not included. 2 Includes zero error, span error, thermal effect on zero, thermal effect on span, thermal hysteresis, pressure-non-linearity, pressure hysteresis and non-repeatability. **3** Safety and Productivity Solutions **Heavy Duty Pressure Transducers** MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi ## **Figure 1. Operating and Temperature Compensation for All Regulated Output Options** **==> picture [295 x 134] intentionally omitted <==** **----- Start of picture text -----**<br> 125<br>124<br>123<br>122<br>121 Operating and Temperature<br>120 Compensated Area<br>119 for Regulated Output<br>118<br>117<br>116<br>6 8 10 12 14 16 18 20 22 24 26 28 30<br>Supply Voltage (Vdc)<br>Operating Temperature (°C)<br>**----- End of picture text -----**<br> Note: Dot indicates the maximum operating temperature of 125 °C [257 °F] with a 24 V supply. ## **Figure 2. Operating and Temperature Compensation for 4 mA to 20 mA Output** **==> picture [294 x 170] intentionally omitted <==** **----- Start of picture text -----**<br> 125<br>120 10 Ohm 250 Ohm<br>115 Load Load<br>110<br>105<br>100<br>95<br>90<br>85 Operating and Temperature<br>80 Compensated Area<br>75 for 4 mA to 20 mA Output<br>70<br>65<br>60<br>6 8 10 12 14 16 18 20 22 24 26 28 30<br>Supply Voltage (Vdc)<br>Operating Temperature (°C)<br>**----- End of picture text -----**<br> Note: The operating area is extended with a 250 Ohm resistor. Higher loads extend the operating area. Dot indicates the maximum operating temperature when using a 24 V supply and a 250 Ohm resistor. **Figure 3. Example Mounting Dimensions (Electrical Termination “B” Shown. For reference only. mm/(in).)** |**Pin/Wire Colors**| |---| |**Pin**<br>**Voltage**<br>**Current**<br>a<br>+ excitation<br>+ excitation<br>b<br>output<br>- excitation<br>c<br>common<br>no connection<br>~~rsrs~~<br>~~a~~| |A variety of pressure ports and electrical| |termination connection options are available.| |Refer to the Figure 4 for possible combinations.| |Contact your Honeywell representative for| |details.| **4** Safety and Productivity Solutions **Heavy Duty Pressure Transducers** MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi ## **Figure 4. Nomenclature and Order Guide** E For example, **MLH150PSB01B** defines an MLH Series Heavy Duty Pressure Transducer, 150 psi pressure range, sealed gage pressure reference, Metri-Pack 150 electrical connector type, 1/4-18 NPT pressure port type, 4 mA to 20 mA output. ## **MLH 150 P S B 01 B** **==> picture [137 x 487] intentionally omitted <==** **----- Start of picture text -----**<br> Series [1]<br>Heavy Duty<br>MLH<br> Pressure Transducer<br>Pressure Range<br> bar psi<br>006 6 050 50<br>010 10 100 100<br>016 16 150 150<br>025 25 200 200<br>040 40 250 250<br>060 60 300 300<br>100 100 500 500<br>160 160 01K 1000<br>250 250 02K 2000<br>350 350 03K 3000<br>500 500 05K 5000<br>550 550 08K 8000<br>Unit<br>B bar<br>P [psi]<br>Pressure Reference<br>G Gage<br>S Sealed Gage [2]<br>Electrical Connector Type<br>B Metri-Pack 1503<br>C Hirschmann (mates with G4W1F)<br>D M12 x 1 (Brad Harrison micro)<br>G DIN 43650-C, 8 mm male<br>H AMP Superseal 1.5 [4]<br>L Cable (24 AWG,1 meter)<br>M Cable (24 AWG, 3 meter)<br>P Flying leads (20 AWG, 6 in)<br>T Deutsch DTM04-3P (integral)<br>**----- End of picture text -----**<br> ## **Output Signal** - **A** 0.5 Vdc to 4.5 Vdc ratiometric from 5 Vdc excitation - **B** 4 mA to 20 mA **C** 1 Vdc to 6 Vdc regulated **D** 0.25 Vdc to 10.25 Vdc regulated **E** 0.5 Vdc to 4.5 Vdc regulated **G** 1 Vdc to 5 Vdc **Pressure Port Type 01**[ 1/4-18 NPT] **06**[1/8-27 NPT] **09**[ 7/16-20 UNF 1/4 inch 45° Flare ] Female Schrader (SAE J512) **11** 1/2-14 NPT **13** R 1/4-19 BSPT (ISO 7-1 tapered thread) **19** R 1/8-28 BSPT (ISO 7-1 tapered thread) **==> picture [78 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Mating Connector [3]<br>**----- End of picture text -----**<br> - 1 Not all catalog listing combinations are available. Custom products are available. Please contact Honeywell. - 2 Sealed gage option is only available in pressure ranges at or above 8 bar | 100 psi. - 3 Metri-Pack 150 mating connectors with shielded cable and 22 AWG wire are available from Honeywell. Order part - no. 3685301 for 1 m [3.2 ft] cable length and part no. 3685302 for 3 m [9.8 ft] cable length. - 4 Available with Output Signal **A** only. **5** Safety and Productivity Solutions ## **ADDITIONAL INFORMATION** The following associated literature is available on the Honeywell web site at sensing.honeywell.com: - Product line guide - Product range guide - Product installation instructions ## **WARNING PERSONAL INJURY** DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. **Failure to comply with these instructions could result in death or serious injury.** ## **WARNING** ## **MISUSE OF DOCUMENTATION** - The information presented in this datasheet is for reference only. Do not use this document as a product installation guide. - Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. **Failure to comply with these instructions could result in death or serious injury.** ## **Warranty/Remedy** Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. **The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.** While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer’s sole responsibility to determine the suitability of the product in the application. ## **For more information** Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use. To learn more about Honeywell’s sensing and switching products, call 1.800.537.6945 , visit sensing.honeywell.com, or e-mail inquiries to info.sc@honeywell.com ## **Honeywell Safety and Productivity Solutions** 008118-8-EN IL50 October 2016 © 2016 Honeywell International Inc. All rights reserved. 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywell.com
Updated at February 9, 2023
Honeywell is a globally recognized leader in the design and manufacture of advanced sensing and switching solutions. Renowned for engineering components that deliver enhanced precision and ruggedness, Honeywell provides essential technologies for demanding applications across critical healthcare, aerospace, and industrial equipment. With a comprehensive portfolio built to address both basic and complex design challenges, the company stands at the forefront of reliable electronic component manufacturing. The core of our Honeywell offering is an extensive selection of high-performance sensors and transducers. This includes a robust lineup of pressure sensors and transducers engineered for accurate fluid and gas measurement in challenging environments. Furthermore, we provide a wide array of temperature sensors and specialized temperature sensing NTC thermistors designed for stable thermal management, alongside precision current sensors and load cells that deliver critical feedback for control systems. Beyond advanced sensing technology, Honeywell’s expertise extends to essential circuit protection and electromechanical components. Our selection encompasses power relays, thermal magnetic circuit breakers, and standard terminal blocks, ensuring safe and efficient power distribution. Whether integrating core components or sourcing specialized accessories, design engineers can rely on Honeywell for uncompromising quality and operational excellence.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →