MKS2PIAC110
General Purpose Relay, MK-S Series, Power, Non Latching, DPDT, 110 VAC, 10 A
- Manufacturer: OMRON INDUSTRIAL AUTOMATION
- Product type: Power Relays
- Contact Configuration:DPDT; Coil Voltage:110VAC; Contact Current:10A; Product Range:-; Relay Mounting:Socket; Coil Type:Non Latching; Contact Voltage VAC:250VAC; Relay Terminals:Quick Con
- SVHC: No SVHC (17-Dec-2014)
- Coil Type: Non Latching
- Coil Voltage: 110VAC
- Product Range: MK-S Series
- Relay Mounting: Socket
- Coil Resistance: 1.24kohm
- Contact Current: 10A
- Relay Terminals: Quick Connect
- Contact Material: Silver Tin Indium
- Contact Voltage VAC: 250V
- Contact Voltage VDC: 30V
- Contact Configuration: DPDT
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 6.33 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **General-purpose Relays MK-S New Model**
## **General-purpose Relays Featuring Mechanical Indicator and Lockable Test Button**
- Built-in operation indicator (mechanical and LED), and new models with lockable test button.
- Nameplate provided on models with lockable test button.
- RoHS Compliant.
- UL approval for most models. (UL approval pending for models with built-in LED indicators.)
## **Features**
## **Two-way Action Test Button**
**==> picture [242 x 142] intentionally omitted <==**
**----- Start of picture text -----**<br>
Relay in For Momentary For Lock<br>Normal Operation Operation Operation<br>| ar | a | ae<br>. ; a7 || , r aae ||| , r gael<br>= comes Yellow ae ———l] ae ‘a<br>button<br>Pull down the test Pull down the test<br>button to the first button to the second<br>position, then press the position.<br>yellow button with an (The contact is now in<br>insulated tool to the locked position.)<br>operate the contact.<br>**----- End of picture text -----**<br>
## **Model Number Structure**
## ■ **Model Number Legend**
## **MKS** @@@@@ **-** @ **-** @
**1 2 3 4 5 6 7**
## **1. Contact Form**
- 2: DPDT
- 3: 3PDT
**2. Terminals** P: Plug-in
## **3. Mechanical Indicator/Test Button**
Blank: Mechanical indicator
I: Mechanical indicator and lockable test button
**4. LED Indicator**
Blank: Standard
N: LED indicator
## **5. Coil Polarity**
Blank: Standard
- 1: Reverse polarity (DC coil only)
**6. Surge Absorption**
- Blank: Standard
- D: Surge absorber diode (DC coil only)
- V: Surge absorber varistor (AC coil only)
**7. Internal Connections**
Blank: Standard
- 2 or 5: Non-standard connections (Refer to _“Terminal Arrangement/Internal Connection”_ .)
**8. Rated Voltage**
(Refer to _“Coil Ratings”_ .)
General-purpose Relays **MK-S New Model**
1
**Orderin Information g**
## ■ **List of Models**
|**Type**|**Termi-**<br>**nals**|**Contact form**|**Internal connections**<br>**(See note 3.)**|**With mechanical indicator **|**With mechanical indicator**<br>**and lockable test button**|**Coil ratings**|
|---|---|---|---|---|---|---|
|**Standard**<br>**Models**|Plug-in|DPDT|Standard|MKS2P|MKS2PI|AC/DC|
||||Non-standard|MKS2P-2|MKS2PI-2||
|||3PDT|Standard|MKS3P|MKS3PI||
||||Non-Standard|MKS3P-2|MKS3PI-2||
|||||MKS3P-5|MKS3PI-5||
|**Models with**<br>**LED Indicator**<br>**(See note 2.)**||DPDT|Standard|MKS2PN(1)|MKS2PIN(1)|AC/DC|
||||Non-standard|MKS2PN(1)-2|MKS2PIN(1)-2||
|||3PDT|Standard|MKS3PN(1)|MKS3PIN(1)||
||||Non-Standard|MKS3PN(1)-2|MKS3PIN(1)-2||
|||||MKS3PN(1)-5|MKS3PIN(1)-5||
|**Models with**<br>**Diode**<br>**(See note 2.)**||DPDT|Standard|MKS2P(1)-D|MKS2PI(1)-D|DC|
||||Non-standard|MKS2P(1)-D-2|MKS2PI(1)-D-2||
|||3PDT|Standard|MKS3P(1)-D|MKS3PI(1)-D||
||||Non-Standard|MKS3P(1)-D-2|MKS3PI(1)-D-2||
|||||MKS3P(1)-D-5|MKS3PI(1)-D-5||
|**Models with**<br>**LED Indicator**<br>**and Diode**||DPDT|Standard|MKS2PN-D|MKS2PIN-D|DC|
||||Non-standard|MKS2PN-D-2|MKS2PIN-D-2||
|||3PDT|Standard|MKS3PN-D|MKS3PIN-D||
||||Non-Standard|MKS3PN-D-2|MKS3PIN-D-2||
|||||MKS3PN-D-5|MKS3PIN-D-5||
|**Models with**<br>**Varistor**||DPDT|Standard|MKS2P-V|MKS2PI-V|AC|
||||Non-standard|MKS2P-V-2|MKS2PI-V-2||
|||3PDT|Standard|MKS3P-V|MKS3PI-V||
||||Non-Standard|MKS3P-V-2|MKS3PI-V-2||
|||||MKS3P-V-5|MKS3PI-V-5||
|**Models with**<br>**LED Indicator**<br>**and Varistor**||DPDT|Standard|MKS2PN-V|MKS2PIN-V|AC|
||||Non-standard|MKS2PN-V-2|MKS2PIN-V-2||
|||3PDT|Standard|MKS3PN-V|MKS3PIN-V||
||||Non-Standard|MKS3PN-V-2|MKS3PIN-V-2||
|||||MKS3PN-V-5|MKS3PIN-V-5||
**Note: 1.** When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in the specifications. Example: MKS3P 24 VDC
Rated voltage
**2.** The DC coil comes in two types: standard coil polarity and reverse coil polarity. Refer to _Terminal Arrangement and Internal Connections_ . Example: MKS2PIN1-2 24 VDC
Reverse coil polarity
**3.** Refer to _Terminal Arrangement and Internal Connections_ for non-standard internal _connections_ .
## ■ **List of Models (Order Separately)**
|**Item**|**Type**|**Model**|
|---|---|---|
|Track-mounted Socket|8-pin|PF083A-E|
||11-pin|PF113A-E|
||8-pin|PF083A-D|
||11-pin|PF113A-D|
|Hold-down Clip<br>(For PF083A-E and PF113A-E)||PFC-A1|
General-purpose Relays **MK-S New Model**
2
**S ecifications p**
## ■ **Ratings**
## **Coil Ratings**
|**Rated**|**voltage**|**Rated current**|**Rated current**|**Coil resistance**|**Must operate**<br>**voltage**|**Must release**<br>**voltage**|**Max. voltage**|**Power**<br>**consumption**|
|---|---|---|---|---|---|---|---|---|
|||**50 Hz**|**60 Hz**||||||
|AC|6 V|443 mA|385 mA|3.1Ω|80% max. of rated<br>voltage|30% min. of rated<br>voltage at 60 Hz<br>25% min. of rated<br>voltage at 50 Hz|110% of rated volt-<br>age|Approx. 2.3 VA<br>at 60 Hz<br>Approx. 2.7 VA<br>at 50 Hz|
||12 V|221 mA|193 mA|13.7Ω|||||
||24 V|110 mA|96.3 mA|48.4Ω|||||
||100 V|26.6 mA|23.1 mA|760Ω|||||
||110 V|24.2 mA|21.0 mA|932Ω|||||
||200 V|13.3 mA|11.6 mA|3,160Ω|||||
||220 V|12.1 mA|10.5 mA|3,550Ω|||||
||230 V|10.0 mA|11.5 mA|4,250Ω|||||
||240 V|11.0 mA|9.6 mA|4,480Ω|||||
|DC|6 V|224 mA||26.7Ω||15% min. of rated<br>voltage||Approx. 1.4 W|
||12 V|112 mA||107Ω|||||
||24 V|55.8 mA||430Ω|||||
||48 V|28.1 mA||1,710Ω|||||
||100 V|13.5 mA||7,390Ω|||||
||110 V|12.3 mA||8,960Ω|||||
- **Note: 1.** The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/−20% for AC rated current and ±15% for DC coil resistance.
**2.** Performance characteristic data are measured at a coil temperature of 23°C.
**3.** The maximum voltage is one that is applicable instantaneously to the Relay coil at 23°C and not continuously.
**4.** For DC-operated Relays with the LED indicator built-in, add an LED current of approx. 5 mA to the rated current.
## **Contact Ratings**
|**Contact Ratings**||||
|---|---|---|---|
|**Load**||Resistive load<br>(cosφ = 1)|Inductive load<br>(cosφ = 0.4)|
|**Contact mechanism**||Single||
|**Contact material**||AgSnIn||
|**Rated load**|**NO**|10 A, 250 VAC<br>10A, 30 VDC|7 A, 250 VAC|
||**NC**|5 A, 250 VAC<br>5 A, 30 VDC||
|**Rated carry current**||10 A||
|**Max. switching voltage**||250 VAC, 250 VDC||
|**Max. switching current**||10 A||
|**Max. switching power**|**NO**|2,500 VA/300 W||
||**NC**|1,250 VA/150 W||
General-purpose Relays **MK-S New Model**
3
## ■ **Characteristics**
|■**Characteristics**||
|---|---|
|**Contact resistance**|100 mΩmax.|
|**Operate time**|AC: 20 ms max.<br>DC: 30 ms max.|
|**Release time**|20 ms max.(40 ms max. for built-in Diode Relays)|
|**Max. operating frequency**|Mechanical: 18,000 operations/h<br>Electrical:<br>1,800 operations/h (under rated load)|
|**Insulation resistance**|100 MΩmin. (at 500 VDC)|
|**Dielectric strength**|2,500 VAC 50/60 Hz for 1 min between coil and contacts<br>1,000 VAC 50/60 Hz for 1 min between contacts of same polarity and terminals of the same polarity<br>2,500 VAC 50/60 Hz for 1 min between current-carrying parts, non-current-carrying parts, and opposite<br>polarity|
|**Insulation method**|Basic insulation|
|**Impulse withstand voltage**|4.5 kV between coil and contacts (with 1.2×50µs impulse wave)<br>3.0 kV between contacts of different polarity(with 1.2×50µs impulse wave)|
|**Pollution degree**|3|
|**Rated insulation voltage**|250 V|
|**Vibration resistance**|Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)<br>Malfunction: 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)|
|**Shock resistance**|Destruction: 1,000 m/s2(approx. 100 G)<br>Malfunction: 100 m/s2(approx. 10 G)|
|**Endurance**|Mechanical: 5,000,000 operations min. (at 18,000 operations/h under rated load)<br>Electrical:<br>100,000 operations h. (at 1,800 operations/h under rated load)|
|**Failure rate P level (reference value)**|10 mA at 1 VDC|
|**Ambient temperature**|Operating: –40 to 60°C (with no icingor condensation)|
|**Ambient humidity**|Operating: 5% to 85%|
|**Weight**|Approx. 90g|
- **Note: 1.** The values given above are initial values.
**2.** P level: λ60 = 0.1 × 10[-6] /operation
**3.** Ambient temperature of models with LED indicator is −25 to 60°C.
## ■ **Approved Standards UL508 (File No. E41515)**
|**Coil ratings**|**Contact ratings**|**Contact ratings**|**Operations**|
|---|---|---|---|
|6 to 110 VDC<br>6 to 240 VAC|N.O.<br>contact<br> <br> <br>|10 A, 250 V AC 50/60 Hz (Resistive)<br>10 A, 30 V DC (Resistive)<br>7 A, 250 V AC 50/60 Hz (General Use)|6,000|
||N.C.<br>contact<br> <br> <br>|5 A, 250 V AC 50/60 Hz (Resistive)<br>5 A, 30 V DC (Resistive)<br>7 A, 250 V AC 50/60 Hz (General Use)|6,000|
## **CSA Standard: CSA Certification by**
## **: CSA C22.2 No. 14**
**Note:** Applications have been submitted for UL and CSA certification for models with built-in LED indicators.
## **IEC Standard/TUV Certification: - IEC61810 1 (Certification No. R50104853)**
|**Coil ratings**|**Contact ratings**|**Contact ratings**|**Operations**|
|---|---|---|---|
|6, 12, 24, 48,<br>100, 110 VDC<br>6, 12, 24, 100,<br>110, 200, 220,<br>240 VAC|N.O.<br>contact|10 A, 250 V AC 50/60 Hz (Resistive)<br>10 A, 30 V DC (Resistive)<br>7 A, 250 V AC 50/60 Hz (General Use)|100,000|
||N.C.<br>contact|5 A, 250 V AC 50/60 Hz (Resistive)<br>5 A, 30 V DC (Resistive)<br>7 A, 250 V AC 50/60 Hz (General Use)|100,000|
**Note:** When Relays are mounted on the PF083A-E or PF113A-E, the maximum carrying current is 9 A.
## **En ineerin Data g g**
## ■ **Reference Data**
## **Maximum Switching Power Rated Carry Current vs. Ambient Rated Temperature**
**==> picture [319 x 150] intentionally omitted <==**
**----- Start of picture text -----**<br>
100<br>50 10<br>30<br>DC resistive load UL derating curve<br>with NO contact AC resistive load<br>with NO contact<br>10<br>5<br>5 AC inductive<br>load<br>3 (cosφ = 0.4)<br>DC resistive AC resistive load<br>load with with NC contact<br>NC contact<br>0<br>110 30 50 100 300 500 1.000 −40 −20 0 20 40 60 80<br>Switching voltage (V) Ambient temperature (°C)<br>Switching current (A) Rated carry current (A)<br>**----- End of picture text -----**<br>
**Note:** The lower limit of the ambient operating temperature for models with built-in operation indicators is −25°C.
General-purpose Relays **MK-S New Model**
4
## **Dimensions**
**Note:** All units are in millimeters unless otherwise indicated.
## **Models without Test Button**
## **Models with Lockable Test Button**
**==> picture [172 x 76] intentionally omitted <==**
**----- Start of picture text -----**<br>
34.5 max.<br>{ o ot |<br>a<br>34.5 max. 0.8 52.5 max.<br>ee<br>**----- End of picture text -----**<br>
**==> picture [227 x 76] intentionally omitted <==**
**----- Start of picture text -----**<br>
34.5 max.<br>T iel |e<br>| [=a =<br>Re 34.5 max. 0.8 52.5 max.<br>**----- End of picture text -----**<br>
## **Sockets**
See below for Socket dimensions.
**==> picture [305 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
Socket Surface-mounting Socket (for track or screw mounting)<br>PCee Finger-protection models ---<br>a Maximum carry current 10 A 5 A<br>2 poles PF083A-E PF083A-D PF083A<br>3 poles PF113A-E PF113A-E-D PF113A<br>**----- End of picture text -----**<br>
**Note:** Use the Surface-mounting Sockets (i.e., finger-protection models) with "-E" at the end of the model number. When using the PF083A and PF113A, be sure not to exceed the Socket's maximum carry current of 5 A. Using at a current exceeding 5 A may lead to burning. Round terminals cannot be used for finger-protection models. Use Y-shaped terminals.
**==> picture [507 x 153] intentionally omitted <==**
**----- Start of picture text -----**<br>
PF083A-E (Conforming to EN 50022) PF113A-E (Conforming to EN 50022)<br>Eight, M3.5 × 7 sems Terminal Arrangement Terminal Arrangement<br>7 4 Eleven, M3.5 × 7 sems<br>—1—7 —4 2OOG 0000<br>7 4<br>ialslslat Toe — Hy Ce,<br>52 max. 35.4<br>| aes Le | e335 SEED i ae<br>inal hop | ee 52 max. BENG ct 35.4 —<br>PTA — LJ oratoms ha =f vel<br>ee SS /_ = DOO foeoo” |e ify Ol, ) o<br>4 33 3.5 wt 2 | ECISIcIeN | Lo<br>41 max. . jo——— =] aN j be<br>21 max. Mounting Holes 4 34 3.5 2 Mounting Holes<br>Two, M4 or two 4.5-dia. holes 42.8 max. 31 max. Two, M4 or two 4.5-dia. holes<br>$$.|-—— 33±0.2 ——+ +- 33± = 0.2<br>**----- End of picture text -----**<br>
General-purpose Relays **MK-S New Model**
5
**==> picture [507 x 508] intentionally omitted <==**
**----- Start of picture text -----**<br>
PF083A-D PF113A-D<br>8 Terminal Arrangement<br>24 22 12 14 8 Terminal Arrangement<br>5.5 6 5 4 3 32 24 21 22 12<br>5.5 8 7 6 5 4<br>GEER bd +<br>4 27 27<br>t s \ or 4 dod)<br>Eight, M4 screws<br>7 8 1 2 Eight, M4 screws<br>A2 roe) 21 11 A1 9 ai 10 2 3<br>34 A2 11 1 A1 14<br>31 11<br>65 Mounting Holes 65<br>Two, M4 or two 4.5-dia. hole Mounting Holes<br>Two, M4 or two 4.5-dia. hole<br>30<br>30<br>38 38<br>se t te t<br>Hold-down Clips<br>PFC-A1<br>(2 pieces per set)<br>4.6<br>60.8<br>62<br>it<br>6 4.5<br>afb 7<br>Mounting Tracks<br>PFP-100N, PFP-50N PFP-100N2<br>(Conforming to EN 50022) (Conforming to EN 50022)<br>—= ——=<br>16<br>7.3±0.15<br>4.5<br>4.5<br>35±0.3 27±0.15 35±0.3 27 24 29.2<br>f 15 25 10 a 25 1000 (500)* g 25 10 25 * LT 1 15 25 10 25 1000±4 25 10 25 15 Tl 1 1.5<br>* This dimension applies to the PFP-50N Mounting Track. * A total of twelve 25 × 4.5 elliptic holes is provided with six<br>holes cut from each track end at a pitch of 10 mm.<br>**----- End of picture text -----**<br>
## **Hold-down Clips**
**==> picture [104 x 105] intentionally omitted <==**
**----- Start of picture text -----**<br>
PFC-A1<br>(2 pieces per set)<br>4.6<br>60.8<br>62<br>it<br>6 4.5<br>afb 7<br>**----- End of picture text -----**<br>
## **Mounting Tracks**
## **Mounting Height with Sockets**
**Surface-mounting Sockets**
**==> picture [258 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
Three<br>poles<br>77.8 Two 87.8<br>(See note.) poles 74.3 (See note.) 84.3<br>oe<br>PF083A(-E) PF113A(-E)<br>Note: PF083A(-E) and PF113A(-E) allow either track or screw mounting.<br>**----- End of picture text -----**<br>
General-purpose Relays **MK-S New Model**
6
## **Terminal Arrangement/Internal Connection (Bottom View)**
|**Standard Models**<br>**(AC/DC Coil)**<br>**Models with**<br>**LED Indicator**<br>**(AC Coil)**<br>**Models with Diode**<br>**(DC Coil:**<br>**Standard Polarity)**<br>**Models with**<br>**LED Indicator and**<br>**DIode**<br>**(DC Coil:**<br>**Reverse Polarity)**<br>**Standard Models**<br>**(DC Coil:**<br>**Standard Polarity)**<br>**Models with Diode**<br>**(DC Coil:**<br>**Reverse Polarity)**<br>**Models with**<br>**LED indicator**<br>**(DC Coil)**|**MK**|**S2P(I)**|**MKS2P(I)-2**|**MKS2P(I)-2**|**MKS2P(I)-2**||**MKS3P(I)**|**MKS3P(I)**||**MKS3P(I)-2**|**MKS3P(I)-2**|**MKS3P(I)-2**|**MKS3P(I)-5**|**MKS3P(I)-5**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||1<br>2<br>3<br>4|5<br>6<br>7<br>8||8<br>6<br>3<br>1<br>2<br>7<br>4<br>5|||1<br>2<br>3<br>4<br>5<br>6<br>7<br>8<br>10<br>11<br>9|||5<br>4<br>3<br>2<br>1||9<br>11<br>10<br>8<br>7<br>6|9<br>11<br>10<br>8<br>7<br>6<br>5<br>4<br>3<br>2<br>1||
||||||||||||||||
||**MKS**|**2P(I)N**|**MKS2P(I)N-2**||||**MKS3P(I)N**|||**MKS3P(I)N-2**|||**MKS3P(I)N-5**||
||4<br>3<br>2<br>1|8<br>7<br>6<br>5|5<br>4<br>7<br>2<br>1<br>3<br>6<br>8||||1<br>2<br>3<br>4<br>5|6<br>7<br>8<br>10<br>11<br>9||5<br>4<br>3<br>2<br>1||9<br>11<br>10<br>8<br>7<br>6|5<br>4<br>3<br>2<br>1|9<br>11<br>10<br>8<br>7<br>6|
||||||||||||||||
||**MKS**|**2P(I)N**|**MKS2P(I)N-2**||||**MKS3P(I)N**|||**MKS3P(I)N-2**|||**MKS3P(I)N-5**||
||4<br>3<br>2<br>1|8<br>7<br>6<br>5||4<br>2<br>1<br>3|5<br>7<br>6<br>8||1<br>2<br>3<br>4<br>5|6<br>7<br>8<br>10<br>11<br>9||4<br>3<br>|5<br><br>2<br>1|9<br>11<br>10<br>8<br>7<br>6|5<br>4<br>3<br>2<br>1|9<br>11<br>10<br>8<br>7<br>6|
||||||||||||||||
||||||||||||||||
||||||||||||||||
||||||||||||||||
||**MKS2P(I)N1**||**MKS2P(I)N1-2**||||**MKS3P(I)N1**|||**MKS3P(I)N1-2**|||**MKS3P(I)N1-5**||
||4<br>3<br>2<br>1|8<br>7<br>6<br>5||5<br>4<br>7<br>2<br>1<br>3<br>6<br>8|||1<br>2<br>3<br>4<br>5|6<br>7<br>8<br>10<br>11<br>9||4<br>3<br>|5<br><br>2<br>1|9<br>11<br>10<br>8<br>7<br>6|5<br>4<br>3<br>2<br>1|9<br>11<br>10<br>8<br>7<br>6|
||||||||||||||||
||||||||||||||||
||||||||||||||||
||**MKS2P(I)-D**||**MKS2P(I)-D-2**||||**MKS3P(I)-D**|||**MKS3P(I)-D-2**|||**MKS3P(I)-D-5**||
||4<br>3<br>2<br>1|8<br>7<br>6<br>5||4<br>2<br>1<br>3|5<br>7<br>6<br>8||1<br>2<br>3<br>4<br>5|6<br>7<br>8<br>10<br>11<br>9||5<br>4<br>3<br>2<br>1||9<br>11<br>10<br>8<br>7<br>6|5<br>4<br>3<br>2<br>1|9<br>11<br>10<br>8<br>7<br>6|
||||||||||||||||
||||||||||||||||
||**MKS2P(I)1-D**||**MKS2P(I)1-D-2**||||**MKS3P(I)1-D**|||**MKS3P(I)1-D-2**|||**MKS3P(I)1-D-5**||
||4<br>3<br>2<br>1|8<br>7<br>6<br>5||5<br>4<br>7<br>2<br>1<br>3<br>6<br>8|||1<br>2<br>3<br>4<br>5|6<br>7<br>8<br>10<br>11<br>9||5<br>4<br>3<br>2<br>1||9<br>11<br>10<br>8<br>7<br>6|5<br>4<br>3<br>2<br>1|9<br>11<br>10<br>8<br>7<br>6|
||||||||||||||||
||||||||||||||||
||**MKS2P(I)N-D**||**MKS2P(I)N-D-2**||||**MKS3P(I)N-D**|||**MKS3P(I)N-D-2**|||**MKS3P(I)N-D-5**||
||1<br>2<br>3<br>4|5<br>6<br>7<br>8||3<br>1<br>2<br>4|8<br>6<br>7<br>5||1<br>2<br>3<br>4<br>5|6<br>7<br>8<br>10<br>11<br>9||4<br>3<br>|5<br><br>2<br>1|9<br>11<br>10<br>8<br>7<br>6|5<br>4<br>3<br>2<br>1|9<br>11<br>10<br>8<br>7<br>6|
||||||||||||||||
||||||||||||||||
||||||||||||||||
General-purpose Relays **MK-S New Model**
7
|**Models with Varistor**<br>**(AC Coil)**<br>**Models with**<br>**LED indicator and**<br>**Varistor**<br>**(AC Coil)**|**MKS2P(I)-V**|**MKS2P(I)-V**|**MKS2P(I)-V**|**MKS2P(I)-V**|**MKS2P(I)-V-2**|**MKS2P(I)-V-2**|**MKS2P(I)-V-2**||**MKS3P(I)-V**|**MKS3P(I)-V**|**MKS3P(I)-V**||**MKS3P(I)-V-2**|**MKS3P(I)-V-2**|**MKS3P(I)-V-2**|**MKS3P(I)-V-5**|**MKS3P(I)-V-5**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||4<br>3||8<br>7<br>6<br>5|2<br>3|5<br>4<br>7<br><br>1<br><br>6<br>8|||2<br>3<br>4|1<br><br><br>5|6<br>7<br>8<br>10<br>11<br>9||4<br>3<br>2|5|9<br>11<br>10<br>8<br>7<br>6|9<br>11<br>10<br>8<br>7<br>6<br>5<br>4<br>3<br>2<br>1||
|||2<br>1||||||||||||1||||
|||||||||||||||||||
|||||||||||||||||||
|||||||||||||||||||
||**MKS2P(I)N-V**||||**MKS2P(I)N-V-2**||||**MKS3P(I)N-V**||||**MKS3P(I)N-V-2**|||**MKS3P(I)N-V-5**||
|||3|4|5<br>6<br>7<br>8|3<br>2|1<br><br>4|8<br>6<br>7<br>5||4<br>3<br>2|5<br><br><br>1|9<br>11<br>10<br>8<br>7<br>6||2<br>3<br>4|5<br>|6<br>7<br>8<br>10<br>11<br>9|2<br>3<br>4|1<br>5<br>6<br>7<br>8<br>10<br>11<br>9|
|||2|1|||||||||||1<br>||||
|||||||||||||||||||
## **Safet Precautions y**
## ■ **Safety Precautions for Correct Use**
## **Installation**
Mount the MK-S with the marking at the bottom.
## **Handling**
Check the coil polarity of models with built-in diodes and wire them correctly (DC operation coil).
## **Test Button**
Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON. Before using the test button, confirm that circuits, the load, and any other connected item will operate safely.
Check that the test button is released before turning ON relay circuits.
If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position.
Use an insulated tool when you operate the test button.
Models with test buttons or LED indicators fulfill the requirements for reinforced insulation between live parts and the front of cover only when the Relay is in a complete condition, i.e. with the nameplate, nameplate frame, test button, and slider in place. If any of these parts are removed, only the requirements for basic insulation are fulfilled.
General-purpose Relays **MK-S New Model**
8
General-purpose Relays **MK-S New Model** 9
10 General-purpose Relays **MK-S New Model**
General-purpose Relays **MK-S New Model** 11
## **Warrant and A lication Considerations y pp**
## **Read and Understand this Catalog**
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments.
## **Warranty and Limitations of Liability**
## **WARRANTY**
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
## **LIMITATIONS OF LIABILITY**
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
## **Application Considerations**
## **SUITABILITY FOR USE**
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
## **Disclaimers**
## **PERFORMANCE DATA**
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON _Warranty and Limitations of Liability._
## **CHANGE IN SPECIFICATIONS**
Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased product.
## **DIMENSIONS AND WEIGHTS**
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
## **ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.**
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
## Cat. No. J168-E1-01 **In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company**
**Control Devices Division H.Q.**
Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7109/Fax: (81)75-344-7149
Printed in Japan ????-?M (????) (?)
Updated at June 7, 2026
With a legacy spanning over 80 years, Omron Industrial Automation is a globally recognized leader in the manufacture of advanced industrial control and automation components. Renowned for their reliability and engineering excellence, Omron delivers comprehensive solutions that enhance efficiency, machine safety, and precision across a wide range of manufacturing environments. Our extensive portfolio of Omron products is heavily focused on their industry-leading sensing and switching technologies. We offer a vast selection of sensors, excelling specifically in high-performance proximity sensors, light sensors, and temperature sensors. Complementing this range are robust switching solutions, featuring a deep inventory of power relays, solid-state relays, safety relays, and essential relay accessories designed for demanding operational requirements. Beyond sensing and switching, Omron is highly regarded for its precision automation and process control equipment. Our selection features highly accurate temperature controllers, versatile process controllers, and sophisticated panel displays and instrumentation. To support these fundamental systems, we also supply dependable Omron power supplies, notably AC/DC converters, alongside vital connectivity components like DIN rail terminal blocks to ensure secure, efficient, and complete industrial setups.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →