Image not available
Illustrative purposes only
MFM-05-15
AC/DC Open Frame Power Supply (PSU), Medical, 1 Output, 5 W, 80V AC to 264V AC, Fixed
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Open Frame Power Supplies
- No. of Outputs:1 Output; Power Rating (Covection Cooling):5W; Power Rating (Forced Cooling):-; Input Voltage VAC:80V AC to 264V AC; Power Supply Output Type:Fixed; Output Voltage - Outpu
- SVHC: No SVHC (25-Jun-2025)
- Product Range: MFM-05 Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 80V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 333mA
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 15VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: Medical
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 5W
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 7.75 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- MFM 05 series** 5W High Reliable Green Medical On Board Type cSAL US ~~4~~ cennrie )Ea CB C€ ## + + ## ■ **** - ‧1.65"x0.88" compact size - ‧Medical safety approved (2 x MOPP) accroding to - ANSI/AAMI ES60601-1 and IEC/EN60601-1 - ‧Suitable for BF application with appropriate system consideration - ‧No load power consumption<0.075W - ‧Extremely low leakage current ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧Wide operating temp. range -40 ~ +85℃ - ‧EMI class B for class Ⅱ configuration - ‧Protections: Short circuit / Overload / Over voltage / Over temperature - ‧ - ‧52K hours - ‧3 years warranty ## ■ **** Ⅱ μ ## ■ **** ## ** ** _File Name:MFM-05-SPEC 2017-09-12_ **- MFM 05 series** 5W High Reliable Green Medical On Board Type ## **SPECIFICATION** ||**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE Note.2**<br>**RATED POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE Note.6**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**OVER TEMPERATURE**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1000ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load<br>40ms/230VAC 12ms/115VAC at full load<br>80 ~ 264VAC<br>47 ~ 440Hz<br>0.2A/115VAC 0.1A/230VAC<br>110% ~ 180% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>20 ~ 90% RH non-condensing<br>-40 ~ +85℃(Refer to "Derating Curve")<br>-40 ~ +100℃, 10 ~ 95% RH non-condensing<br>±0.03%/℃(0 ~ 60℃)<br>10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>1799.5Khrs min. MIL-HDBK-217F (25℃)<br>42*22.3*20.5mm (L*W*H) or 1.65 *0.88 0.8<br>"<br>"<br>0" inch<br>**SAFETY STANDARDS**<br>**RIPPLE & NOISE (max.)Note.4**<br>**VOLTAGE TOLERANCENote.5**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 9)**<br>**PROTECTION**<br>Protection type : Shut off o/p voltage, clamping by zener diode<br>Protection type : Shut down o/p voltage, recovers automatically after temperature goes down<br>I/P-O/P:4KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH<br>**LEAKAGE CURRENT (max.) Note.7** Touch current <80 A/264VAC<br>μ<br>**ISOLATION LEVEL**<br>Primary-Secondary: 2xMOPP<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>**Standard**<br>EN55011 (CISPR11)<br>EN55011 (CISPR11)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Class B<br>Class B<br>Class A<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>EN55024 , EN60601-1-2, EN61204-3<br>Level 4, 15KV air ; Level 4, 8KV contact<br>Level 3<br>Level 3<br>Level 3, 1KV/Line-Line<br>Level 3<br>Level 4<br>100% dip 1 periods, 30% dip 25 periods,<br>100% interruptions 250 periods<br>**MFM-05-3.3**<br>**MFM-05-5**<br>**MFM-05-12**<br>**MFM-05-15**<br>**MFM-05-24**<br>±0.3%<br>±0.5%<br>±0.3%<br>±0.5%<br>±0.3%<br>±0.5%<br>±0.3%<br>±0.5%<br>±0.3%<br>±0.5%<br>±2.5%<br>±2.5%<br>±2.5%<br>±2.5%<br>±2.5%<br>5V<br>3.3V<br>12V<br>15V<br>24V<br>1A<br>1.25A<br>0.42A<br>0.33A<br>0.23A<br>0 ~ 1A<br>0 ~ 1.25A<br>0 ~ 0.42A<br>0 ~ 0.33A<br>0 ~ 0.23A<br>5W<br>4.1W<br>5W<br>5W<br>5.5W<br>13.8 ~ 16.2V<br>17.3 ~ 20.3V<br>27.6 ~ 32.4V<br>5.75 ~ 6.8V<br>3.8 ~ 5V<br>**SOLDERING TEMPERATURE**<br>260℃±5℃/10sec.max.<br>**PEAK CURRENT**<br>1.38A<br>1.1A<br>0.46A<br>0.36A<br>0.25A<br>**OPERATING ALTITUDENote.8 **5000 meters<br>0.018Kg; 270pcs/5.8Kg/0.97CUFT<br>100mVp-p<br>100mVp-p<br>150mVp-p<br>150mVp-p<br>180mVp-p<br>80%<br>74%<br>80%<br>81%<br>82%<br>**PEAK LOAD(10sec.)Note.3**4.6W<br>5.5W<br>5.5W<br>5.4W<br>6W<br>COLD START 25A/115VAC 45A/230VAC<br>rd<br>IEC60601-1, EN60601-1, UL ANSI/AAMI ES60601-1(3.1 version), CAN/CSA-C22 3 Edition approved ; Design refer to EN60335-1<br>℃<br><br><br><br><br><br><br>℃<br><br><br><br>μ<br>μ|**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE Note.2**<br>**RATED POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE Note.6**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**OVER TEMPERATURE**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1000ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load<br>40ms/230VAC 12ms/115VAC at full load<br>80 ~ 264VAC<br>47 ~ 440Hz<br>0.2A/115VAC 0.1A/230VAC<br>110% ~ 180% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>20 ~ 90% RH non-condensing<br>-40 ~ +85℃(Refer to "Derating Curve")<br>-40 ~ +100℃, 10 ~ 95% RH non-condensing<br>±0.03%/℃(0 ~ 60℃)<br>10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>1799.5Khrs min. MIL-HDBK-217F (25℃)<br>42*22.3*20.5mm (L*W*H) or 1.65 *0.88 0.8<br>"<br>"<br>0" inch<br>**SAFETY STANDARDS**<br>**RIPPLE & NOISE (max.)Note.4**<br>**VOLTAGE TOLERANCENote.5**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 9)**<br>**PROTECTION**<br>Protection type : Shut off o/p voltage, clamping by zener diode<br>Protection type : Shut down o/p voltage, recovers automatically after temperature goes down<br>I/P-O/P:4KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH<br>**LEAKAGE CURRENT (max.) Note.7** Touch current <80 A/264VAC<br>μ<br>**ISOLATION LEVEL**<br>Primary-Secondary: 2xMOPP<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>**Standard**<br>EN55011 (CISPR11)<br>EN55011 (CISPR11)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Class B<br>Class B<br>Class A<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>EN55024 , EN60601-1-2, EN61204-3<br>Level 4, 15KV air ; Level 4, 8KV contact<br>Level 3<br>Level 3<br>Level 3, 1KV/Line-Line<br>Level 3<br>Level 4<br>100% dip 1 periods, 30% dip 25 periods,<br>100% interruptions 250 periods<br>**MFM-05-3.3**<br>**MFM-05-5**<br>**MFM-05-12**<br>**MFM-05-15**<br>**MFM-05-24**<br>±0.3%<br>±0.5%<br>±0.3%<br>±0.5%<br>±0.3%<br>±0.5%<br>±0.3%<br>±0.5%<br>±0.3%<br>±0.5%<br>±2.5%<br>±2.5%<br>±2.5%<br>±2.5%<br>±2.5%<br>5V<br>3.3V<br>12V<br>15V<br>24V<br>1A<br>1.25A<br>0.42A<br>0.33A<br>0.23A<br>0 ~ 1A<br>0 ~ 1.25A<br>0 ~ 0.42A<br>0 ~ 0.33A<br>0 ~ 0.23A<br>5W<br>4.1W<br>5W<br>5W<br>5.5W<br>13.8 ~ 16.2V<br>17.3 ~ 20.3V<br>27.6 ~ 32.4V<br>5.75 ~ 6.8V<br>3.8 ~ 5V<br>**SOLDERING TEMPERATURE**<br>260℃±5℃/10sec.max.<br>**PEAK CURRENT**<br>1.38A<br>1.1A<br>0.46A<br>0.36A<br>0.25A<br>**OPERATING ALTITUDENote.8 **5000 meters<br>0.018Kg; 270pcs/5.8Kg/0.97CUFT<br>100mVp-p<br>100mVp-p<br>150mVp-p<br>150mVp-p<br>180mVp-p<br>80%<br>74%<br>80%<br>81%<br>82%<br>**PEAK LOAD(10sec.)Note.3**4.6W<br>5.5W<br>5.5W<br>5.4W<br>6W<br>COLD START 25A/115VAC 45A/230VAC<br>rd<br>IEC60601-1, EN60601-1, UL ANSI/AAMI ES60601-1(3.1 version), CAN/CSA-C22 3 Edition approved ; Design refer to EN60335-1<br>℃<br><br><br><br><br><br><br>℃<br><br><br><br>μ<br>μ|**MFM-05-3.3**|**MFM-05-5**|**MFM-05-5**|**MFM-05-12**|**MFM-05-15**|**MFM-05-15**|**MFM-05-24**| |---|---|---|---|---|---|---|---|---|---| |||**DC VOLTAGE**|3.3V|5V||12V|15V||24V| |||**RATED CURRENT**|1.25A|1A||0.42A|0.33A||0.23A| |||**CURRENT RANGE Note.2**|0 ~ 1.25A|0 ~ 1A||0 ~ 0.42A|0 ~ 0.33A||0 ~ 0.23A| |||**PEAK CURRENT**|1.38A|1.1A||0.46A|0.36A||0.25A| |||**RATED POWER**|4.1W|5W||5W|5W||5.5W| |||**PEAK LOAD(10sec.)Note.3**|4.6W|5.5W||5.5W|5.4W||6W| |||**RIPPLE & NOISE (max.)Note.4**|100mVp-p|100mVp-p||150mVp-p|150mVp-p||180mVp-p| |||**VOLTAGE TOLERANCENote.5**|±2.5%|±2.5%||±2.5%|±2.5%||±2.5%| |||**LINE REGULATION**|±0.3%|±0.3%||±0.3%|±0.3%||±0.3%| |||**LOAD REGULATION**|±0.5%|±0.5%||±0.5%|±0.5%||±0.5%| |||**SETUP, RISE TIME**|1000ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load||||||| |||**HOLD UP TIME (Typ.)**|40ms/230VAC 12ms/115VAC at full load||||||| |||**VOLTAGE RANGE Note.6**|80 ~ 264VAC||||||| |||**FREQUENCY RANGE**|47 ~ 440Hz||||||| |||**EFFICIENCY (Typ.)**|74%|80%||80%|81%||82%| |||**AC CURRENT (Typ.)**|0.2A/115VAC 0.1A/230VAC||||||| |||**INRUSH CURRENT (Typ.)**|COLD START 25A/115VAC 45A/230VAC||||||| |||**LEAKAGE CURRENT (max.) Note.7**|Touch current <80 A/264VAC<br>μ||||||| |||**OVERLOAD**|110% ~ 180% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed||||||| |||**OVER VOLTAGE**|Protection type : Shut off o/p voltage, clamping by zener diode<br>13.8 ~ 16.2V<br>17.3 ~ 20.3V<br>27.6 ~ 32.4V<br>5.75 ~ 6.8V<br>3.8 ~ 5V||||||| |||**OVER TEMPERATURE**|Protection type : Shut down o/p voltage, recovers automatically after temperature goes down||||||| |||**WORKING TEMP.**|-40 ~ +85℃(Refer to "Derating Curve")||||||| |||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing||||||| |||**STORAGE TEMP., HUMIDITY**|-40 ~ +100℃, 10 ~ 95% RH non-condensing||||||| |||**TEMP. COEFFICIENT**|±0.03%/℃(0 ~ 60℃)||||||| |||**SOLDERING TEMPERATURE**|260℃±5℃/10sec.max.||||||| |||**VIBRATION**|10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes||||||| |||**SAFETY STANDARDS**<br>**ISOLATION LEVEL**<br>**OPERATING ALTITUDENote.8 **|5000 meters||||||| ||||rd<br>IEC60601-1, EN60601-1, UL ANSI/AAMI ES60601-1(3.1 version), CAN/CSA-C22 3 Edition approved ; Design refer to EN60335-1||||||| ||||Primary-Secondary: 2xMOPP||||||| |||**WITHSTAND VOLTAGE**|I/P-O/P:4KVAC||||||| |||**ISOLATION RESISTANCE**<br>**EMC IMMUNITY**<br>**EMC EMISSION**|I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH||||||| ||||**Parameter**||**Standard**|||**Test Level / Note**|| ||||Conducted||EN55011 (CISPR11)|||Class B|| ||||Radiated||EN55011 (CISPR11)|||Class B|| ||||Harmonic Current||EN61000-3-2|||Class A|| ||||Voltage Flicker||EN61000-3-3|||-----|| ||||EN55024 , EN60601-1-2, EN61204-3||||||| ||||**Parameter**||**Standard**|||**Test Level / Note**|| ||||ESD||EN61000-4-2|||Level 4, 15KV air ; Level 4, 8KV contact|| ||||Radiated||EN61000-4-3|||Level 3|| ||||EFT / Burst||EN61000-4-4|||Level 3|| ||||Surge||EN61000-4-5|||Level 3, 1KV/Line-Line|| ||||Conducted||EN61000-4-6|||Level 3|| ||||Magnetic Field||EN61000-4-8|||Level 4|| ||||Voltage Dips and Interruptions||EN61000-4-11|||100% dip 1 periods, 30% dip 25 periods,<br>100% interruptions 250 periods|| |||**MTBF**|1799.5Khrs min. MIL-HDBK-217F (25℃)||||||| |||**DIMENSION**|42*22.3*20.5mm (L*W*H) or 1.65 *0.88 0.8<br>"<br>"<br>0" inch||||||| |||**PACKING**|0.018Kg; 270pcs/5.8Kg/0.97CUFT||||||| |||℃<br><br><br><br><br><br><br>℃<br><br><br><br>μ<br>μ|||||||| _File Name:MFM-05-SPEC 2017-09-12_ **- MFM 05 series** 5W High Reliable Green Medical On Board Type **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Block Diagram<br>fosc : 100KHz<br>RECTIFIERS RECTIFIERS +V<br>EMI POWER<br>I/P & &<br>FILTER SWITCHING<br>FILTER FILTER -V<br>PWM DETECTION<br>O.L.P.<br>CONTROL CIRCUIT<br>Derating Curve Output Derating VS Input Voltage<br>100<br>100<br>90<br>80<br>70<br>70<br>60<br>40<br>50<br>20<br>40<br>-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 85 (HORIZONTAL) 80 95 100 115 120 140 160 180 200 220 240 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%)<br>LOAD (%)<br>**----- End of picture text -----**<br> _File Name:MFM-05-SPEC 2017-09-12_ **- MFM 05 series** ## 5W High Reliable Green Medical On Board Type ## **Mechanical Specification** **==> picture [33 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> Unit: mm<br>**----- End of picture text -----**<br> **==> picture [273 x 291] intentionally omitted <==** **----- Start of picture text -----**<br> 42<br>AC/N<br>+V<br>FS1<br>AC/L -V<br>1.75 TOP VIEW 1.75<br>1.8 4.5<br>SIDE VIEW<br>1.05 3.5<br>22.3<br>10.75 8<br>1.9 1.9<br>16<br>20.5<br>**----- End of picture text -----**<br> ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:MFM-05-SPEC 2017-09-12_
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →