- Manufacturer: EOS POWER
- Product type: AC / DC Enclosed Power Supplies
- SVHC: To Be Advised
- Product Range: MFLS400 Series
- No. of Outputs: 1Outputs
- Output Power Max: 400W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 16.7A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: Medical
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 159.52 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Medical Grade MFLS400 Watt AC-DC Power Supplies** ee EO: ## **400 Watt** - l 400 Watts Forced Cooled - l Efficiency up to 90% - l -40 to 70 °C operating temperature - l High power density : 23.70W/inch[3] - l Meets EN60601-1-2, 4[th] Edition - l Thermal Shut-Down feature / Dual fusing - l 2.56m Hours, Telcordia -SR332-issue 3 MTBF - l Suitable for BF applications ~~The New MFLS400 Series is designed to work with Forced air cooling. This is a highly efcient power supply that can deliver up to 400 W with air. This new series comes with two optons. ie. Casing with Side Fan and Top Fan.~~ ## ~~**400 Watts**~~ |~~**400 Watts**~~||||| |---|---|---|---|---| |**Model Number Description Voltage Max. Load Min. Load Ripple**|**Model Number Description Voltage Max. Load Min. Load Ripple**|**Model Number Description Voltage Max. Load Min. Load Ripple**|**Model Number Description Voltage Max. Load Min. Load Ripple**|**Model Number Description Voltage Max. Load Min. Load Ripple**1| |||||| |MFLS400-1312<br>MFLS400-1315|with JST Connector<br>with JST Connector<br>12V<br>15V|25A<br>20A|0.0A<br>0.0A|5%<br>5%| |MFLS400-1324|with JST Connector<br>24V|16.70A|0.0A|2%| |MFLS400-1330|with JST Connector<br>30V|13.30A|0.0A|2%| |MFLS400-1348<br>MFLS400-1358|with JST Connector<br>with JST Connector<br>48V<br>58V|8.30A<br>6.90A|0.0A<br>0.0A|2%<br>2%| For Top FAN vesrion add “TF” Ex. MFLS400-1324-TF For Side FAN version add “SF” Ex. MFLS400-1324-SF |~~**Pin Connection**~~||| |---|---|---| |J1 (Input)|PIN 1|AC LINE| ||PIN 2|NOT FITTED| ||PIN 3|AC NEUTRAL| |J2 (Output)|PIN 1,2,3|V1 +VE| ||~~PIN 4,5,6~~|~~V1 -VE~~| |Self clinching nut||Earth| |(J9)|PIN 1|+VS (Remote Sense)| |Signal Connector|PIN 2|-VS (Remote Sense)| ~~**www.eospower.com**~~ ~~4EM-21-295 1 39-DE60-41055-002 / A~~ **Medical Grade AC-DC Power Supplies** **MFLS400 Watt** ## Notes 1. Ripple is peak to peak with 20 MHz bandwidth and 10 μF (Tantalum capacitor) in parallel with a 0.1 μF capacitor at rated line voltage and load ranges. 2. Specifications are for nominal input voltage, 25°C unless otherwise stated. 3. 400W with Forced cooling at 115 VAC to 264VAC. 4. Combine Output Power of Main Output, Fan supply should not exceed 400 W. 5. Output ripple can be more than 2 % of the output voltage. ## **Input** **==> picture [518 x 82] intentionally omitted <==** **----- Start of picture text -----**<br> |||||| |---|---|---|---|---| |Characteristic Minimum Typical Maximum Units Notes & Conditions| |Input Voltage|85|264|VAC|De-rate linearly from 100% at 115VAC to 70% at 85VAC| |Input Frequency|47|63|Hz| |Input Current|6.3|A| |Inrush Current|75|A| |Power Factor|exceeds 0.95 at Full Load| **----- End of picture text -----**<br> **==> picture [530 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||| |---|---|---|---|---|---| |Output| |Characteristic Minimum Typical Maximum Units Notes & Conditions| |es|Output Power|ee Gs nes|400|er|W| |Po|Hold-up Time|8mS|At 230 VAC| |Po|Line Regulation|+/-0.5%| |Pe|Load Regulation|+/-0.5%| |Pf|Output Voltage Adjustability|+/-3%| |Pe|Rise Time|55|ms| |Set Point Tolerance|+/-1%| |Po| |Pe|Over Current Protection|> 105%| |Po|Over Voltage Protection|110 to 140%| |Ce|Transient Response|25% step load change, at 0.1A/uS slew rate, 50% duty cycle, 50Hz=4% , recovery time < 5 ms| **----- End of picture text -----**<br> ## ~~**General**~~ **==> picture [469 x 98] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |Characteristic Minimum Typical Maximum Units Notes & Conditions| |Efficiency|90%|At 230 VAC| |Mean Time Between|Failure|2.56m Hours|Telcordia -SR332-issue 3| |Isolation: Input to Output|4380|Input to Output: 4380VAC (2x MOPP),| |Input to Ground|1690|VAC|Input to Ground: 1690VAC (1x MOPP),| |Output to Ground|1500|Output to Ground: 1500VAC (1x MOPP)| |Leakage Current|300 uA Typical; Touch current <100uA| **----- End of picture text -----**<br> 4EM-21-295 2 39-DE60-41055-002 / A ~~**www.eospower.com**~~ ## **MFLS400 Watt** ## **Medical Grade AC-DC Power Supplies** ## **Efficiency Vs Load** ## **Environmental** ||**Environmental**|**Environmental**|**Environmental**|**Environmental**|**Environmental**|**Environmental**|**Environmental**| |---|---|---|---|---|---|---|---| ||**Characteristic Minimum Typical Maximum Units Notes & Conditions**|**Characteristic Minimum Typical Maximum Units Notes & Conditions**|**Characteristic Minimum Typical Maximum Units Notes & Conditions**|**Characteristic Minimum Typical Maximum Units Notes & Conditions**|**Characteristic Minimum Typical Maximum Units Notes & Conditions**|**Characteristic Minimum Typical Maximum Units Notes & Conditions**|| ||Operating Temperature|-40||70|°C|-40 to 0 startup is guaranteed with spec deviation.<br>70°C (Derated)|| ||Storage Temperature|-40||85|°C||| ||Relative Humidity|5||95|%|RH, non-condensing|| ||Operating Altitude|||16,000|ft||| ||Short Circuit Protection||Hiccup mode||||| ||<br>Switching Frequency||PFC – 70 to 130 KHz ,PWM – 50-80 KHz||||| ||Cooling|||||Inbuilt Fans for cooling|| ||||||||| ~~**www.eospower.com**~~ ~~4EM-21-295 3 39-DE60-41055-002 / A~~ **Medical Grade MFLS400 Watt AC-DC Power Supplies** a ## **Mechanical Specifications** **==> picture [433 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |AC Input Connector (J1)|TE Connectivity: 647676-3| |Mating: 1-1123722-3 ; Crimp: 1123721-2| |DC Output Connector (J2)|TE Connectivity: 647676-6| |Mating: 1-1123722-6 ; Crimp: 1123721-2| |Earth|Ø4.25 Self clinching nut,| |(PEM S-M3-0-ZI) or Equivalent| |Dimensions|CK with Top Fan 123.7 x 77.2 x 82.3 approx mm| |CK with Side Fan 135 x 109 x 50 mm| |Weight|700 gm approx| **----- End of picture text -----**<br> ## **EMC: Emissions** **==> picture [495 x 69] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |Phenomenon Standard Test Level Notes & Conditions| |Conducted|EN 55011|Level B|CISPR22-B, FCC PART15-B| |Radiated|EN 55011|Level A|Level B with external core| |-| |(King core K5B RC 25x12x15|M or Equivalent| |in input cable)| **----- End of picture text -----**<br> ## ~~**EMC: Immunity**~~ **==> picture [438 x 143] intentionally omitted <==** **----- Start of picture text -----**<br> |||||||||| |---|---|---|---|---|---|---|---|---| |Phenomenon Standard Test Level Criteria Notes & Conditions| |Input Curr|Medical D|e|nt Harmonics|vice EMC|EN 61000-3-2|Class A| |V|L|o|w Volta|ltage Fluctuat|ge PSU EMC|on and Flicker|EN 61000-3-3|compliance| |ESD Immunity|ESD Immunity|EN 61000-4-2|Level 4|A| |Radiated Field Immunity|Radiated Immunity|EN 61000-4-3|Level 3|A| |Electrical Fast Transient Immunity|EFT/Burst|EN61000-4-4|Level 3|A| |Surge Immunity|Surge|EN 61000-4-5|Level 3|A| |Conducted Immunity|Conducted Immunity|EN61000-4-6|Level 3|A| |Magnetc Field Immunity|EN61000-4-8|Level 4|A| |Voltage dips, interruptons|EN61000-4-11|A & B| **----- End of picture text -----**<br> Standard IEC60601-1-2 : 2014 (4th Editon) ## ~~**Safety Approvals**~~ **==> picture [497 x 86] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |Safety Agency|Safety Standard|Notes & Conditions| |CB|IEC 60601-1:2005, IEC 60601-1:2005/AMD1:2012| |Input to Output: 4380VAC (2x MOPP),| |Nemko|EN60601-1| |Input to Ground: 1690VAC (1x MOPP),| |UL|ANSI /AAMI 60601-1| |Output to Ground: 1500VAC (1x MOPP)| |CSA|CSA C22.2 No.60601-1| |CE Mark|Complies with LVD Directve| **----- End of picture text -----**<br> **www.eospower.com** ~~4EM-21-295 4 39-DE60-41055-002 / A~~ **Medical Grade AC-DC Power Supplies** ## **MFLS400 Watt** ## **Derating Curve** De-rate linearly from 100% at 115VAC to 70% at 85VAC ## **Derating Curve** Forced air cooled load: 400W up to 40 °C. De-rate by 1.66%/ °C above 40°C till 70°C 4EM-21-295 5 39-DE60-41055-002 / A **www.eospower.com** **Medical Grade MFLS400 Watt AC-DC Power Supplies** ee EO: ## **Derating Curve** Forced air cooled load: 300W up to 40 °C. De-rate by 1.66% / °C above 40°C **www.eospower.com** 4EM-21-295 6 39-DE60-41055-002 / A ## **Medical Grade MFLS400 Watt AC-DC Power Supplies** ee E@: ## **Mechanical Drawing** **==> picture [167 x 16] intentionally omitted <==** **----- Start of picture text -----**<br> Cover kit with Top Fan<br>**----- End of picture text -----**<br> 4EM-21-295 7 39-DE60-41055-002 / A **www.eospower.com** **Medical Grade MFLS400 Watt AC-DC Power Supplies** ee E@: ## **Mechanical Drawing** ## **Cover kit with Side Fan** **www.eospower.com** 4EM-21-295 8 39-DE60-41055-002 / A
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →