Image not available
Illustrative purposes only
MEP-200A12J BNA
AC/DC Open Frame Power Supply (PSU), ITE, Industrial, Medical & Household, 1 Output, 200 W
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: DELTA ELECTRONICS
- Product type: AC / DC Open Frame Power Supplies
- SVHC: To Be Advised
- Product Range: MEP-200A Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 16.67A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Industrial, Medical & Household
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 200W
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 93.62 € |
| Current stock | 10+ |
| Lead time | 30 days |
**TECHNICAL DATASHEET** **Medical / Industrial AC-DC Power Supply** □J BNA 200 W Convection 2” x 4” / MEP-200A󠄒 ## **MEP-200A** ## **Highlights & Features** - 2" x 4" x 1.12" low profile - Up to 22.32 W/inch[3] power density - Up to 200 W output with natural convection cooling - High efficiency up to 95% - Up to 70 °C Ambient Operation - Up to 1000KHrs MTBF - 2 x MOPP Isolation - Suited for Type BF Medical Products. - Class B Conducted and Radiated EMI - IEC60601-1-2 4[th] Edition Immunity Compliance > **Safety Certifications** owe EKO ® **Model Number:** MEP-200A□J BNA **Unit Weight:** 0.21 kg (0.463 lb) **Dimensions (W × L × H):** 50.8 x 101.6 x 28.5 mm (2.0 x 4.0 x 1.12 inch) ## **General Description** The MEP-200A offers 200 W output power and 3 output voltage of 12 V, 24 V and 48 V in a 2” x 4” footprint and low profile design is suitable for space-constrained applications. It supports a wide operating temperature ranging from -30°C to +70°C. Electric shock protection complying with 2 x MOPP, the MEP-200A offers reliable power supply for type BF medical equipment. The MEP-200A is certified with medical, ICT and home appliance safety approvals, including UL/ TUV/ CE/ UKCA and CB certification, as well as EMC approvals to EN 55032 Class B. It is applicable to type BF medical products, IT equipment and household appliances. ## **Model Information** |**Model Information**|||| |---|---|---|---| |**ModelName**|**Input Voltage**|**OutputVoltage**|**Max Continuous Current**| |MEP-200A12J BNA|90 - 264 Vac|12 Vdc|16.67 A| |MEP-200A24J BNA|90 - 264 Vac|24 Vdc|8.34 A| |MEP-200A48J BNA|90 - 264 Vac|48 Vdc|4.17 A| ## **Model Numbering** |**Model Numbering**|**Model Numbering**|**Model Numbering**|**Model Numbering**|**Model Numbering**|**Model Numbering**|| |---|---|---|---|---|---|---| |||||||**CC Code**| |**MEP –**|**200**|**A**|□|**J**|□|**BNA**| |ME: Delta Medical<br>Power Supply<br>P: Open frame|ME: Delta Medical<br>Max Wattage in<br>Product Series<br>200: 200 W|Family Code|Output Voltage<br>(Single Output)<br>12 – 12V<br>24 – 24V<br>48 – 48V|Family Code<br>J: JST connector|Blank|Delta Standard,<br>No conformal coating| All parameters are specified at 25°C ambient unless otherwise noted. 1 **www.DeltaPSU.com (December 2023, Rev. 04.3)** **TECHNICAL DATASHEET** **Medical / Industrial AC-DC Power Supply** □J BNA 200 W Convection 2” x 4” / MEP-200A󠄒 ## **Specifications** Input Ratings / Characteristics |**Model Number**|**Model Number**|MEP-200A12J|MEP-200A24J|MEP-200A48J| |---|---|---|---|---| |Nominal Input Voltage||100 - 240 Vac||| |Input Voltage Range||90 - 264 Vac||| |Nominal Input Frequency||50 - 60 Hz||| |Input FrequencyRange||47 - 63 Hz||| |Input Current(max.)||2.5 A||| |Input Surge Voltage(max.)||300 Vac for 100 ms||| |Efficiency @ full load|@ 115 Vac 92.4%|@ 115 Vac 92.4%|93.%|93.8 %| ||@230 Vac|93.8%|94.7%|95.4%| |Inrush Current(max.)||60 A at 264 Vac, cold start||| |Earth leakage current(max)||0.3 mA at NC, 1.0mA @ SFC*1||| |Touch current(max)||0.1 mA at NC, 0.5mA @ SFC*1||| |Power Factor (min.)||0.95 at 115 V & 230 Vac / 50 Hz, full load||| *1 NC: normal condition, SFC: single fault condition **Figure 1. Typical Efficiency Curve for 12 V (max. 200 W) Figure 2. Typical Efficiency Curve for 24 V (max. 200 W)** **Figure 3. Typical Efficiency Curve for 48 V (max. 200 W)** All parameters are specified at 25°C ambient unless otherwise noted. **www.DeltaPSU.com (December 2023, Rev. 04.3)** 2 **TECHNICAL DATASHEET** **Medical / Industrial AC-DC Power Supply** □J BNA 200 W Convection 2” x 4” / MEP-200A󠄒 ## Output Ratings / Characteristics |**Model Number**|MEP-200A12J|MEP-200A24J|MEP-200A48J| |---|---|---|---| |Output Power (max.)|200 W||| |Total Regulation|± 3 %||| |Line Regulation (max.)|1 %||| |Load Regulation (max.)|2 %||| |PARD*2(20 MHz) (typ.)|1 % pk-pk Vrated or 150 mV which is larger at rated load||| |Start-up Time (max.)|1,000 ms with AC turn on||| |Hold-up Time (min.)|12 ms @ 180 W load, with nominal input range||| |Rise Time (max.)|50 ms||| |Dynamic Response (overshoot & undershoot O/P voltage)|± 10% @ with 5-100% load change,<br>(50% duty @ 10 Hz & 10 KHz, 0.5 A/us slew rate)||| |Capacitive Load(max.)|(50% duty @ 10 Hz & 10 KHz, 0.5 A/us slew rate)<br>1,500 uF||| *2 PARD is measured with an AC coupling mode, and in parallel to end terminal with 0.1 µF ceramic capacitor & 47 µF electrolytic capacitor. PSU need to burn in > 5 minutes when AMB ≤ 0°C ## Mechanical |Mechanical|Mechanical|| |---|---|---| |Package||Open frame| |Dimensions (W x L x H)||50.8 x 101.6 x 28.5 mm (2 x 4 x 1.12 inch)| |Unit Weight||0.21 kg(0.463 lb)| |Cooling System||Convection / Force air| |Terminal|Input JST: B2P3-VH or equivalent|Input JST: B2P3-VH or equivalent| ||Output JST: B6P-VH-B (LF) (SN) or equivalent|Output JST: B6P-VH-B (LF) (SN) or equivalent| ## Environment |Environment||| |---|---|---| |Surrounding Air Temperature|Operating -30 °C to +70 °C|Operating -30 °C to +70 °C| ||Storage|-40 °C to +85 °C| |Temperature Power De-rating||Linear power derating from 100% load at 45 °C to 50% load at<br>70 °C with 2 %/°C (24 V / 48 V model)<br>Linear power derating from 100% load at 40°C to 50% load at<br>70 °C with 2 %/°C (12 V)<br>Note: see power de-rating curves below| |OperatingHumidity||5-95 % RH(Non-condensing)| |OperatingAltitude||Upto 5,000 meters(upto 16,400 feet or 106-54kPa)| |Non-OperatingAltitude||Upto 5,575 meters(upto 18,290 feet or 106-50kPa)| |Shock Test(Non-Operating)||50 G, 11 ms, 3 shocks for each direction| |Vibration(Non-Operating)||5 – 500 Hz, 2 Grms, 15 minute for each three axis| All parameters are specified at 25°C ambient unless otherwise noted. **www.DeltaPSU.com (December 2023, Rev. 04.3)** 3 ## **TECHNICAL DATASHEET Medical / Industrial AC-DC Power Supply** □J BNA 200 W Convection 2” x 4” / MEP-200A󠄒 Power De-rating Curve (Convection) **==> picture [17 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>**----- End of picture text -----**<br> **==> picture [228 x 130] intentionally omitted <==** **----- Start of picture text -----**<br> 170 |<br>150<br>s<br>H|<br>| —— Convection (12V,24V,48V)<br>0 t<br>90 115 1380 264<br>**----- End of picture text -----**<br> Power De-rating Curve (Force Air) **==> picture [16 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>**----- End of picture text -----**<br> ## Load De-rating Fixture and Test Setup (FAN: EFB0412VHD) All parameters are specified at 25°C ambient unless otherwise noted. **www.DeltaPSU.com (December 2023, Rev. 04.3)** 4 **TECHNICAL DATASHEET** **Medical / Industrial AC-DC Power Supply** □J BNA 200 W Convection 2” x 4” / MEP-200A󠄒 Convection Test Setup **==> picture [141 x 156] intentionally omitted <==** **----- Start of picture text -----**<br> Component side<br>face up<br>PSU<br>At Least keep 40mm for ventilation<br>CO O OCO OOO OC O O OOOOCOOOOOEOO OOO OOO O O OCOOOO O OO O<br>Non-heat generating surface<br>**----- End of picture text -----**<br> ## Notes 1 (For MEP-200A24J BNA/MEP-200A48J BNA): 1. Fan source and box dimensions could be changed or modified to meet air speed: 0.86 m/s 2. Airflow: 5.2 CFM (For reference, air speed should meet 0.86 m/s) 3. Used fan voltage: 7.0 V (For reference, the voltage should be adjusted for every fan to meet air speed: 0.86 m/s) 4. Unit: mm ## Notes 2 (For MEP-200A12J BNA): 5. Fan source and box dimensions could be changed or modified to meet air speed: 0.99 m/s 6. Airflow: 6.0 CFM (For reference, air speed should meet 0.99 m/s) 7. Used fan voltage: 8.0 V (For reference, the voltage should be adjusted for every fan to meet air speed: 0.99 m/s) 8. Unit: mm All parameters are specified at 25°C ambient unless otherwise noted. **www.DeltaPSU.com (December 2023, Rev. 04.3)** 5 **TECHNICAL DATASHEET** **Medical / Industrial AC-DC Power Supply** □J BNA 200 W Convection 2” x 4” / MEP-200A󠄒 ## Protections |Overvoltage (max)|Main output 125% of rated normal voltage, latch mode| |---|---| |Over Load / Over Current (max)|Main output 140% of rated current, Hiccup Mode| |Over Temperature|Latch mode for main output| |Short Circuit|Hiccupmode (Non-latching,auto-recovery)| |Protection Against Shock3)|Class I & II| *3 Applicable to Class II medical equipment which needs to be evaluated in the end product assembly. ## Reliability Data |Safety Standards / Directives|Safety Standards / Directives|| |---|---|---| |Medical Safety||IEC60601-1 CB report<br>TUV EN60601-1<br>ANSI/AAMI ES 60601-1+CAN/CSA-C22.2 No.60601-1| |ITE Safety||IEC60950-1 CB report<br>IEC62368-1 CB report<br>TUV EN 62368-1<br>UL 62368-1 and CAN/CSA C22.2 No. 62368-1<br>CCC GB 17625.1;GB 4943.1;GB/T 9254.1| |Household||IEC60335-1 CB report<br>IEC61558-1 & -2-16 CB report<br>TUV EN 60335-1<br>TUV EN 61558-1 & -2-16| |CE||In conformance with EN 60601-1: 2006 + A11: 2011 + A1: 2013 +<br>A12: 2014 & EN 60601-1-2: 2015| |UKCA||In conformance with Electromagnetic Compatibility Regulations 2016<br>and Medical Devices Regulations 2002 (UK MDR 2002)| |Galvanic Isolation|Input to/Output (2XMOPP)<br>Input to/Ground (1XMOPP)<br>Output to/Ground (1XMOPP)|4,000 Vac<br>1,500 Vac<br>1,500 Vac (Type BF application rated)| ## Safety Standards / Directives All parameters are specified at 25°C ambient unless otherwise noted. **www.DeltaPSU.com (December 2023, Rev. 04.3)** 6 **TECHNICAL DATASHEET** **Medical / Industrial AC-DC Power Supply** □J BNA 200 W Convection 2” x 4” / MEP-200A󠄒 ## EMC |EMC / Emissions|EN 55011/EN 55032, FCC Title 47: Class B for Class I<br>Note: Class B Radiated Emission for Class II connection without<br>earth connection needs to add EMI filter. Please consult with Delta<br>for detailed information.| |---|---| |Harmonic Current Emissions<br>IEC 61000-3-2|Meet Class D limit| |Voltage Flicker<br>IEC 61000-3-3|| |Immunityto|| |Electrostatic Discharge<br>IEC 61000-4-2|Level 4 criteria A1) 5)<br>Air discharge: 15 kV<br>Contact discharge: 8 kV| |Radiated Field<br>IEC 61000-4-3|Criteria A1)<br>80 MHz – 2,700 MHz, 10 V/m AM modulation<br>Level 2 Criteria A1) 5)<br>385 MHz – 5,785 MHz, 28 V/mpulse mode and other modulation| |Electrical Fast Transient / Burst<br>IEC 61000-4-4|Level 3 Criteria A1): 2 kV| |Surge<br>IEC 61000-4-5|Level 3 Criteria A1) 5)<br>Common Mode3): 2 kV<br>Differential Mode4): 1 kV| |Conducted<br>IEC 61000-4-6|Level 2 Criteria A1) 5)<br>150 kHz – 80 MHz, 3 Vrms, 6 Vrms at ISM bands and<br>Amateur radio bands| |Power Frequency Magnetic Fields<br>IEC 61000-4-8|Criteria A1) 5)<br>Magnetic field strength 30 A/m| |Voltage Dips<br>IEC 61000-4-11|30% 10 ms Criteria A1)<br>60% 100 ms Criteria B2)<br>100% 5,000 ms Criteria B2)| |Voltage Dips5)<br>IEC 60601-1-2|Criteria A1) 5) <br>0% UT,0.5 cycle (10 ms),<br>(0°, 45°, 90°, 135°, 180°, 225°, 270°, 315°, 360°)<br>Criteria B2), can meet Criteria A with 120 W or lower load<br>0% UT, 1 cycle (20 ms), 0°<br>Criteria B2)<br>70% UT, 25 cycle (500 ms), 0°<br>Criteria B2)<br>0% UT, 250 cycle (5,000 ms), 0°| - 1) Criteria A: Normal performance within the specification limits - 2) Criteria B: Irregular output or shut down during test. Automatically restored to normal operation after test. - 3) Asymmetrical: Common mode (Line to earth) - 4) Symmetrical: Differential mode (Line to line) - 5) Compliant with IEC60601-1-2 (4[th] Edition) All parameters are specified at 25°C ambient unless otherwise noted. **www.DeltaPSU.com (December 2023, Rev. 04.3)** 7 **TECHNICAL DATASHEET** **Medical / Industrial AC-DC Power Supply** □J BNA 200 W Convection 2” x 4” / MEP-200A󠄒 ## **Dimensions** **W x L x H:** 50.8 x 101.6 × 28.5 mm (2 x 4 × 1.12 inch) ## **Notes:** - All dimensions are in millimeters and inches. - The base plate is not earth connected just for heating dissipation. Users need to consider safety isolation requirement when assembly the PSU. Please consult with Delta before installation. Connector Definition and Pin Assignment |Input Connector CN1|Input Connector CN1| |---|---| |Pin 1|Neutral| |Pin 2|Line| |CN1:<br>JST(HEADER): B2P3-VH<br>MATCH WITH JST(HOUSING): VAR-2<br>JST(CRIMP SOCKET): SVA-41T-P1.|| |Output Connector CN101|| |PIN1-3|Output +| |PIN4-6|Output -| |CN101:<br>JST (HEADER): B6P-VH-B (LF) (SN)<br>MATCH WITH JST(HOUSING): VHR-6N<br>JST (CRIMP SOCKET): SVH-21T-P1.1|| All parameters are specified at 25°C ambient unless otherwise noted. **www.DeltaPSU.com (December 2023, Rev. 04.3)** 8 **TECHNICAL DATASHEET** **Medical / Industrial AC-DC Power Supply** □J BNA 200 W Convection 2” x 4” / MEP-200A󠄒 ## **Functions** ## Start-up Time The time required for output voltage to reach 90% of its final steady state value, after the input voltage is applied. ## Rise Time The time required for output voltage to change from 10% to 90% of its final steady state value. ## Hold-up Time Time between the collapse of the AC input voltage, and the output falling to 90% of its steady state value. ## Overvoltage Protection The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 5 under “Protections”. Power supply will latch off, and require removal/re-application of input AC voltage in order to restart. ## Overload & Over Current Protections The power supply’s Overload (OLP) and Over current (OCP) Protections will be activated before output current under 130 % of IO (max. load). Upon such occurrence, VO will start to drop. Once the power supply has reached its maximum power limit, the protection will be activated and the power supply will go into “Hiccup mode” (A󠄒uto-Recovery). The power supply will recover once the fault condition causing the OLP and OCP is removed and IO is back within the specified limit. **Figure 4. Time Sequence** ## Dynamic Response (Main Output) The power supply output voltage will remain within ± 5% of its steady state value, when subjected to a dynamic load 50% to 100% of its rated current. ## **50% to 100% Load** **Figure 6. Hiccup at OLP/OCP** Additionally, if the Iout is > 100% for a prolong period of time (depending on the load), the Over Temperature Protection (OTP) may be activated due to high temperature on critical components. The power supply will then go into latch mode. ## Short Circuit Protection Output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”. The power supply will return to normal operation after the short circuit is removed. **Figure 5. Dynamic Load** ## Over Temperature Protection ## Inrush Current Inrush current is the input current that occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. As mentioned above, the power supply also has Over Temperature Protection (OTP). This is activated when the overload condition persists for an extended duration, and the output current is below the overload trigger point > 100 % load. In the event of a higher operating temperature condition at 100 % load, the power supply will run into OTP when the surrounding air temperature is higher than the operating temperature. When activated, the output voltage will go into latch mode until the input voltage is removed; then, reapplied, and the surrounding air temperature drops to its normal operating temperature. All parameters are specified at 25°C ambient unless otherwise noted. **www.DeltaPSU.com (December 2023, Rev. 04.3)** 9 **TECHNICAL DATASHEET** ## **Medical / Industrial AC-DC Power Supply** □J BNA 200 W Convection 2” x 4” / MEP-200A󠄒 ## **Certificate** Delta has been certified as meeting the requirement of ISO 13485: 2003 and EN ISO 13485:2012 for the design and manufacture of switching power supply and adaptor for medical device. In addition to a UL Total Certification Program (TCP) approved client laboratory for IEC60950 and IEC60065. Delta also has participated UL Client Test Data Program (CDTP) for IEC 60601 ## **Attention** Delta provides all information in the datasheets on an “A󠄒S IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. ## **Manufacturer and Authorized Representatives Information** ## Manufacturer ## Thailand Delta Electronics (Thailand) PCL. 909 Pattana 1 Rd., Muang, Samutprakarn, 10280 Thailand ## Taiwan Delta Electronics, Inc. 3 Tungyuan Road, Chungli Industrial Zone, Taoyuan County 32063, Taiwan ## Authorized Representatives ## The Netherlands Delta Greentech (Netherlands) B.V. Zandsteen 15, 2132 MZ Hoofddorp, The Netherlands ## United Kingdom Delta Electronics Europe Limited 1 Redwood Court, Peel Park Campus, East Kilbride, Glasgow, G74 5PF, United Kingdom All parameters are specified at 25°C ambient unless otherwise noted. **www.DeltaPSU.com (December 2023, Rev. 04.3)** 10
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →