MEB-2K5A24T RAA
AC/DC Enclosed Power Supply (PSU), ITE, Industrial, Household, Medical, 1 Outputs, 2.5 kW, 24 V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: DELTA ELECTRONICS
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (04-Feb-2026)
- Product Range: MEB-2K5A Series
- No. of Outputs: 1Outputs
- Output Power Max: 2.5kW
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 104.2A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 24V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Industrial, Household, Medical
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 571.6 € |
| Current stock | 10+ |
| Lead time | 30 days |
**TECHNICAL DATASHEET**
**Medical / Industrial AC-DC Power Supply** 2,500 W with 5 V/2 A Standby / MEB-2K5A series
## **Highlights & Features**
- Up to 2,500 Watt in 5" x 10.67" x 1.59" package without BUSBAR terminal
- Up to 29.5 W/inch[3] power density
- Full power up to 50°C ambient
- 2 x MOPP Isolation
- Suited for Type BF medical products
-
-
-
-
-
-
-
- 5 V / 2 A standby output
- Active current sharing
- Conformal coating
- Class B Conducted and Radiated EMI
- IEC60601-1-2 4[th] Edition Immunity Compliance
- Normal and reversed option for Remote On/Off and Power Good Signal
- PMBus Ver 1.3 supported
- Intelligent fan speed control
|**Input**|**Input**|**Input**|**Input**|**Input**|
|---|---|---|---|---|
|Input Voltage||85 VAC ~ 264 VAC|||
|Input Frequency||47 Hz ~ 63 Hz|||
|Input Current||16 A max|||
|Inrush Current||<40 A@264 Vac|||
|Power Factor||>0.95@rated load|||
|Efficiency1)||Up to 94%1)|||
|Touch Current<br>(Output to PE)||<100 uA normal, <400 uA SFC|||
|Earth Leakage<br>Current (Input to<br>PE)||<400 uA normal, <700 uA SFC|||
|**Output**|||||
|CV<br>mode|Output<br>Voltage|24 V|36 V|48 V|
||Output<br>Current|0-104.2 A|0-69.5 A|0-52.1 A|
|CC<br>mode|Output<br>Voltage|24-28 V|N/A|48-56 V|
||Output<br>Current|62.5-108 A<br>(2,500 W max)||26-52.1 A<br>(2,500 W max)|
|Ripple & Noise||<1% Vrated pk-pk(CV mode)|||
|StandbyPower||5 V / 2 A(No minimum load required)|||
|**Environmental**|||||
|MTBF||500 KHrs|||
|Operation<br>Temperature||-20°C ~70°C2)|||
|Operation<br>Altitude||5,000 m or 54 kPa|||
## **Safety Certifications**
- IEC 60601-1 CB report
- TUV IEC/EN 60601-1
- ANSI/AAMI ES 60601-1+CAN/CSA 60601-1
- • IEC 60950-1 CB report
- IEC 62368-1 CB report
-
- IEC 60335-1 CB report
-
- IEC 61558-1/-2-16 CB report
-
- TUV EN 60335-1
-
- TUV EN 61558-1/-2-16
- 1) Exclude fan power
- 2) Power de-rating with temperature above 50°C, refer to power de-rating curve for detail
All parameters are specified at 25°C ambient unless otherwise noted. **PSU.deltaww.com (September 2025, Rev. 01.1)**
1
**TECHNICAL DATASHEET**
**Medical / Industrial AC-DC Power Supply** 2,500 W with 5 V/2 A Standby / MEB-2K5A series
**Model Numbering**
**MEB - 2K5 A** `□` **T ̺** `□` **AA ME: Delta Medical Power Supply Max Wattage in Product Series Family Code Output Voltage Inlet Type Revision Control Code** B: Enclosed 2K5: 2,500 W 24: 24 V T: US terminal See below table 36: 36 V 48: 48 V ~~an~~ **Model Information (With 5 V / 2 A standby available) Model Number Input Voltage**[3)] **Output Voltage Current Output Output Power** 85 Vac 0-41.67 A 1,000 W MEB-2K5A24T NAA 90-100 Vac 0-56.25 A 1,350 W 24 Vdc MEB-2K5A24T RAA 110-132 Vac 0-62.5 A 1,500 W 180-264 Vac 0-104.2 A 2,500 W ~~=~~ 85 Vac ~~=~~ 0-27.78 A 1,000 W MEB-2K5A36T NAA 90-100 Vac 0-37.5 A 1,350 W 36 Vdc MEB-2K5A36T RAA 110-132 Vac 0-41.67 A 1,500 W 180-264 Vac 0-69.5 A 2,500 W 85 Vac 0-20.83 A 1,000 W MEB-2K5A48T NAA 90-100 Vac 0-28.125 A 1,350 W 48 Vdc MEB-2K5A48T RAA 110-132 Vac 0-31.25 A 1,500 W ~~==~~ 180-264 Vac 0-52.1 A 2,500 W 3) Please refer to power de-rating curve for more details. **Revision Control Code 1[st] CC code 2[nd] CC code 3[rd] CC code** `□` A A N Remote On/Off state: default ON Product Revision Delta Standard R Remote On/Off state: default OFF ~~a~~
All parameters are specified at 25°C ambient unless otherwise noted. **PSU.deltaww.com (September 2025, Rev. 01.1)**
2
**TECHNICAL DATASHEET**
## **Medical / Industrial AC-DC Power Supply** 2,500 W with 5 V/2 A Standby / MEB-2K5A series
## **Specifications**
|Input Ratings / Characteristics|Input Ratings / Characteristics||||
|---|---|---|---|---|
|Nominal Input Voltage||100-240 Vac|||
|Input Voltage Range||85-264 Vac|||
|Nominal Input Frequency||50-60 Hz|||
|Input Frequency Range||47-63 Hz|||
|Input Current (max)||16 A|||
|Input Surge Voltage (max)||300 Vac for 100 ms|||
|Full Load Efficiency (typ.)|@ 115 Vac 90.3%|@ 115 Vac 90.3%|90.5%|91.1%|
||@ 230 Vac 92.6%|@ 230 Vac 92.6%|92.8%|94.0%|
|Inrush Current (max)||40 A @ 264 Vac, cold/hot start|||
|No load consumption (max)||0.75 W @ remote off status|||
|Earth Leakage Current (Input to PE) (max)||0.4 mA @ NC, 0.7 mA @ SFC4)|||
|Touch Current (Output to PE) (max)||0.1 mA @ NC, 0.4 mA @ SFC4)|||
|Power Factor (min)||0.95 @ 115 V / 50 Hz, 230 V / 50 Hz, full load|||
Input Ratings / Characteristics
4) NC: normal condition, SFC: single fault condition
## Output Ratings / Characteristics
|Output Ratings / Characteristics||||
|---|---|---|---|
|Total Regulation|± 3%|||
|Output Power (max)|2,500 W|||
|Line Regulation (max)|1%|||
|Load Regulation (max)|2%|||
|Ripple & Noise (typ.)|1% pk-pk Vrated @ rated load|||
|Voltage Trimming Range (CV mode)|24-28 V|36-42 V|48-56 V|
|Current Trimming Range (CC mode)|62.5-108 A (voltage<br>range 23-28 V with<br>2,500 W max)|N/A|26-52.1 A (voltage<br>range 45-56 V with<br>2,500 W max)|
|Dynamic Response (Overshoot & Undershoot O/P Voltage)|± 10% @ with 50-100% load change|||
|Start-up Time (typ.)|1200 ms @ 1500 W load, 110 Vac|||
|Hold-up Time (min)|16 ms @ 2000 W load, 230 Vac|||
|Capacitive Load (max)|6000 uF|||
|Rise Time (max)|50 ms|||
|Remote Sense|Up to 500 mV compensation for voltage drop across external wire<br>connections to load. Short and reverse connectionprotected.|||
All parameters are specified at 25°C ambient unless otherwise noted. **PSU.deltaww.com (September 2025, Rev. 01.1)**
3
**TECHNICAL DATASHEET Medical / Industrial AC-DC Power Supply** 2,500 W with 5 V/2 A Standby / MEB-2K5A series
Ripple & Noise Measurement Circuit
PSU Load ~~ae~~ 0.47uF Ceramic Scope 5cm 10uF Electrolytic Test Fixture ~~es~~
**Figure 1. Ripple & Noise Testing Set Up**
## Standby Power
|Nominal Output Voltage of Standby Output (Vrated)|5 V|
|---|---|
|Nominal Output Current of Standby Output|2 A|
|Total Regulation of Standby Output|± 4%|
|Ripple & Noise of Standby Output|100 mV max|
## Mechanical
|Mechanical||
|---|---|
|Package|Enclosed|
|Dimensions (W x L x H)5)|127 x 271 x 40.5 mm (5 x 10.67 x 1.59 inch)|
|Unit Weight|1.95 kg (4.30 lb)|
5) Without BUSBAR terminal
All parameters are specified at 25°C ambient unless otherwise noted. **PSU.deltaww.com (September 2025, Rev. 01.1)**
4
**TECHNICAL DATASHEET**
## **Medical / Industrial AC-DC Power Supply** 2,500 W with 5 V/2 A Standby / MEB-2K5A series
## Environment
|Environment|||
|---|---|---|
|Surrounding Air Temperature|Operating|Absolute Maximum/Minimum Rating.<br>-20°C to +70°C. Linear power derate from 100% load at<br>50°C, to 50% load at 70°C<br>Note: see power de-rating curves below|
||Storage|-40°C to +85°C|
|Operating Humidity||5-95% RH (Non-Condensing)|
|Operating Altitude||Up to 5,000 meters (up to 16,400 feet or 106-54 kPa)|
|Shock Test (Non-Operating)||50G, 11 ms, 3 shocks for each direction|
|Vibration (Operating)||5-500 Hz, 2.09 Grms, 20 minutes for each three axis|
|Acoustic Noise6)(typ.)||45 dB @ 80% load, 25°C|
|Pollution Degree||3 (for IEC 60335-1)|
6) Acoustic Noise test set up according to ISO-7779
## Power De-rating Curve
All parameters are specified at 25°C ambient unless otherwise noted. **PSU.deltaww.com (September 2025, Rev. 01.1)**
5
**TECHNICAL DATASHEET**
**Medical / Industrial AC-DC Power Supply** 2,500 W with 5 V/2 A Standby / MEB-2K5A series
Protections (for both main output and 5 Volt Standby outputs, unless otherwise indicated)
|Overvoltage (max)|Main output 145% of rated normal voltage, Latch Mode|
|---|---|
||Standby 125% of rated voltage, Latch Mode|
|Over load / Over current (max)|Main output 130% of rated current, with Hiccup Mode (Non-Latching,|
||Auto-Recovery)|
||Standby 3.2 A max with Hiccup Mode (Non-Latching, Auto-Recovery)|
|Over Temperature|Hiccup Mode (Non-Latching, Auto-Recovery)|
|Short Circuit|Hiccup Mode for Main output and Standby|
||(Non-Latching, Auto-Recovery)|
|Reliability Data||
|MTBF (Minimum) at 230 Vac, 2,500 W, 35 °C|500 Khrs based on Telecordia SR-332|
|Operating Life (Minimum) at 230 Vac, 2,500 W, 25°C|26,280 hrs|
## Reliability Data
Safety Standards / Directives
|Safety Standards / Directives|Safety Standards / Directives||
|---|---|---|
|Medical Safety||IEC 60601-1 CB report<br>TUV IEC/EN 60601-1<br>ANSI/AAMI ES 60601-1+CAN/CSA 60601-1|
|ITE Safety||IEC 60950-1 CB report<br>IEC 62368-1 CB report|
|Home Appliance||IEC 60335-1 CB report<br>IEC 61558-1/-2-16 CB report<br>TUV EN 60335-1<br>TUV EN 61558-1, EN 61558-2-16|
|CE||In conformance with EMC Directive 2014/30/EU and Low Voltage<br>Directive 2014/35/EU<br>EN 60601-1: 2006 + A1: 2013 + A2: 2021 & EN 60601-1-2: 2015+<br>A1:2021|
|UKCA||In conformance with Electromagnetic Compatibility Regulations 2016<br>and Medical Devices Regulations 2002 (UK MDR 2002)|
|Galvanic Isolation|Input to/Output<br>(2XMOPP)<br>Input to/Ground<br>(1XMOPP)<br>Output to/Ground<br>(1XMOPP)|4000 Vac<br>1500 Vac<br>1500 Vac (Type BF application rated)|
All parameters are specified at 25°C ambient unless otherwise noted. **PSU.deltaww.com (September 2025, Rev. 01.1)**
6
**TECHNICAL DATASHEET**
## **Medical / Industrial AC-DC Power Supply** 2,500 W with 5 V/2 A Standby / MEB-2K5A series
|EMC||
|---|---|
|EMC / Emissions|EN55011/ EN55032, FCC Title 47: Class B|
|Harmonic Current Emissions<br>IEC61000-3-2|Meet Class A limit|
|Voltage Flicker<br>IEC61000-3-3||
|Immunity||
|Electrostatic Discharge<br>IEC61000-4-2|Level 4 Criteria A1)5)<br>Air Discharge: 15 kV<br>Contact Discharge: 8 kV|
|Radiated Field<br>IEC61000-4-3|Criteria A1)<br>80 MHz-2700 MHz, 10 V/m AM modulation<br>Level 2 Criteria A1)5)<br>385 MHz-5785 MHz, 28 V/m Pulse mode and other<br>modulation|
|Electrical Fast Transient / Burst<br>IEC61000-4-4|Level 3 Criteria A1): 2 kV|
|Surge<br>IEC61000-4-5|Level 3 Criteria A1)5)<br>Common Mode3): 2 kV<br>Differential Mode4): 1 kV|
|Conducted<br>IEC61000-4-6|Level 2 Criteria A1)5)<br>150 kHz-80 MHz, 3 Vrms, 6 Vrms at ISM bands and<br>Amateur radio bands|
|Power Frequency Magnetic Fields<br>IEC61000-4-8|Criteria A1)5)<br>Magnetic field strength 30 A/m|
|Voltage Dips<br>IEC61000-4-11|30% 10 ms Criteria A1)<br>60% 100 ms Criteria B2)<br>100% 5000 ms Criteria B2)|
|Voltage Dips5)<br>IEC60601-1-2|Criteria A1)@ 2,500 W 180 Vac above<br>0% UT, 0.5 cycle (10 ms)<br>(0°, 45°, 90°, 135°, 180°, 225°, 270°, 315°, 360°)<br>Criteria B2), can meet Criteria A with 1,500 W or lower load<br>0% UT, 1 cycle (20 ms), 0°<br>Criteria B2)<br>70% UT, 25 cycle (500 ms), 0°<br>Criteria B2)<br>0% UT, 250 cycle (5000 ms), 0°|
- 1) Criteria A: Normal performance within the specification limits
- 2) Criteria B: Output out of regulation, or shuts down during test. Automatically restored to normal operation after test.
- 3) Asymmetrical: Common mode (Line to earth)
- 4) Symmetrical: Differential mode (Line to line)
- 5) Compliant with IEC60601-1-2 4th Edition
All parameters are specified at 25°C ambient unless otherwise noted. **PSU.deltaww.com (September 2025, Rev. 01.1)**
7
**TECHNICAL DATASHEET**
## **Medical / Industrial AC-DC Power Supply** 2,500 W with 5 V/2 A Standby / MEB-2K5A series
## Dimensions
## **Mechanical Drawing**
## **Notes:**
1. Base plate mounting, M4 thread holes, maximum penetration 3.0 mm (0.118 inch) from outside face of chassis, maximum torque 9-10 kgf.cm (7.82-8.69 lbf.in).
2. Side mounting, M4 thread holes, maximum penetration 3.0 mm (0.118inch) from outside face of chassis, maximum torque 9-10 kgf.cm (7.82-8.69 lbf.in).
3. CN101, M6 screw in two positions, maximum torque 32 kgf.cm (27.81 inch.Ibs). M3 screw in two positions, maximum torque 4-5 kgf.cm (3.48-4.35 inch.Ibs)
4. CN1, M3.5 screw in three positions, maximum torque 6-7 kgf.cm (5.21-6.08 inch.Ibs).
5. VR: clockwise is to increase the output voltage, anti-clockwise is to reduce the output voltage in voltage mode, and to change current in current mode.
6. All dimensions are in millimeters and inches
All parameters are specified at 25°C ambient unless otherwise noted. **PSU.deltaww.com (September 2025, Rev. 01.1)**
8
**TECHNICAL DATASHEET**
**Medical / Industrial AC-DC Power Supply** 2,500 W with 5 V/2 A Standby / MEB-2K5A series
## Connector Definition and Pin Assignment
|Connector Definition and Pin Assignment|Connector Definition and Pin Assignment|
|---|---|
|**Input Connector CN1(ANYTEK: YK50A)**<br>~~OO~~||
|Pin 1<br>~~———~~|Earth<br>~~———~~<br>~~-st—~~|
|Pin 2<br>~~pS~~|Neutral<br>~~pS~~<br>~~-st—~~|
|Pin 3<br>~~—¢-sSTT~~|Line<br>~~-st—~~<br>~~—¢-sSTT~~|
|**Output Connector**<br>~~ee~~||
|CN101<br>~~ee~~|DC RTN<br>~~ee~~|
||Vo<br>~~ee~~<br>~~Oe~~|
|**Control Connector CN605 (Molex:87833-1051)**<br>**Mating with Molex: 51110-1051 Terminal:0503948052**<br>~~eS~~<br>~~a~~||
|Pin 1<br>~~—_-->-:=i~~<br>~~a~~|5V bus for I2C<br>~~—_-->-:=i~~<br>~~eS~~|
|Pin 2<br>~~a~~|DC RTN of 5V bus for I2C<br>~~eS~~|
|Pin 3<br>~~a~~|Serial data signal(SDA)|
|Pin 4<br>~~a~~<br>~~—_->-+-.s~~|Serial clock signal(SCL)<br>~~—_->-+-.s~~|
|Pin 5<br>~~a~~|NC|
|Pin 6<br>~~a~~<br>~~—_->+.s~~|NC<br>~~—_->+.s~~|
|Pin 7<br>~~a~~|Address bit 0(A0)|
|Pin 8<br>~~a~~|Address bit 1(A1)|
|Pin 9<br>~~—_-+>-+-55~~|Address bit 2(A2)<br>~~—_-+>-+-55~~|
|Pin 10|NC|
|**Control Connector CN602(Molex:87833-7420)**<br>**Mating with Molex: 51110-1451 Terminal:0503948052**<br>~~ee~~||
|Pin 1<br>~~a~~|Remote On_Off/Inhibit +|
|Pin 2<br>~~a~~|Remote On_Off/Inhibit -|
|Pin 3<br>~~—_-+>-+-55~~|Power Good-<br>~~—_-+>-+-55~~|
|Pin 4<br>~~a~~|Power Good+|
|Pin 5<br>~~—_->>+=-~~<br>~~———~~|NC<br>~~—_->>+=-~~|
|Pin 6<br>~~———~~|NC|
|Pin 7<br>~~———~~<br>~~a~~|5V StandbyOutput +|
|Pin 8<br>~~—_->>+=-~~<br>~~———~~|5V StandbyOutput +<br>~~—_->>+=-~~|
|Pin 9<br>~~———~~|DC RTN|
|Pin 10<br>~~———~~<br>~~—_->>+=-~~<br>~~———~~|DC RTN<br>~~—_->>+=-~~|
|Pin 11<br>~~———~~|Remote Sense +|
|Pin 12<br>~~———~~<br>~~—_->>+=-~~|Remote Sense -<br>~~—_->>+=-~~|
|Pin 13<br>~~oo~~|Current Share<br>~~oo~~|
|Pin 14<br>~~—>-—=—CST~~|CC/CV mode switch<br>~~—>-—=—CST~~|
All parameters are specified at 25°C ambient unless otherwise noted. **PSU.deltaww.com (September 2025, Rev. 01.1)**
9
**TECHNICAL DATASHEET**
**Medical / Industrial AC-DC Power Supply** 2,500 W with 5 V/2 A Standby / MEB-2K5A series
## **Functions**
## Start-up Time
The time required for the output voltage to reach 90% of its final steady state value, after the input voltage is applied.
## Rise Time
The time required for the output voltage to change from 10% to 90% of its final steady state value.
## Overvoltage Protection
The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 6 under “Protections”. Power supply will latch off, and require removal/re-application of input AC voltage in order to restart.
## Overload & Over current Protections
## Hold-up Time
Time between the collapse of the AC input voltage, and the output falling to 90% of its steady state value.
**Figure 2. Time Sequence**
## Dynamic Response (Main Output)
The power supply’s Overload (OLP) and Overcurrent (OCP) Protections will be activated when output current exceeds 130% of IO (Max load). In such occurrence, the VO will start to drop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into “Hiccup mode” (Auto-Recovery). The power supply will recover once the fault condition of the OLP and OCP is removed and IO is back within the specifications.
Please be noted the output current might be clamped in constant current mode and in this case, the protection will be triggered by output undervoltage point. (85% of rated output voltage for 24V; 80% of rated output voltage for 36V; and 82% of rated output voltage for 48V).
The power supply output voltage will remain within ±10% of its steady state value, when subjected to a dynamic load 50 to 100% of its rated current.
## ◼ **50% to 100% Load**
**Figure 5. Hiccup at OLP/OCP**
## Short Circuit Protection
**Figure 3. Dynamic Load**
## Inrush Current
Inrush current is the input current that occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage.
Output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, The power supply will return to normal operation after the short circuit is removed.
## Over Temperature Protection
As mentioned above, the power supply also has Over Temperature Protection (OTP). This is activated when the overload condition persists for an extended duration and the output current is below the overload trigger point but >100% load. In the event of a higher operating temperature condition at 100% load, the power supply will run into OTP when the surrounding air temperature is higher than the operating temperature. When activated, the output voltage will go into hiccup mode until the surrounding air temperature drops to its normal operating temperature.
**Figure 4. Inrush Current**
All parameters are specified at 25°C ambient unless otherwise noted. **PSU.deltaww.com (September 2025, Rev. 01.1)**
10
**TECHNICAL DATASHEET**
**Medical / Industrial AC-DC Power Supply** 2,500 W with 5 V/2 A Standby / MEB-2K5A series
## Power Good
Power Good+/- pin is an isolated open collector transistor (80V/50mA rating). A resistor (suggested value 10Kohm, 1/8W) can be added between Power Good- pin and DC RTN, Power Good+ pin can be connected to 5V standby (or, other available pull-up voltage that is no greater than the transistor rating). Value of resistor may have to be adjusted, depending on voltage used, and other end-use conditions of the Power Good+ pin connection to the product. When AC input is on, Power Good Signal (Shown in below figure) generated will be high. When AC input is off, Power Good Signal generated will be low. There will be a minimum of 5 milliseconds between the time the Power Good Signal goes to low level, and the time when the output reaches 90% of its rated value.
**==> picture [199 x 135] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power supply System<br>side 5V standby side<br>Power Good +<br>Power Good -<br>Power Good<br>Signal<br>DC RTN<br>**----- End of picture text -----**<br>
## Remote On_Off/Inhibit
Remote ON_OFF/INHIBIT uses an isolated diode (6V/50mA rating) located within the power supply. This signal can be used to enable or disable only the main output. When the main output is disabled, the +5V Standby output will continue to operate. System can use a switch to conduct through this diode (suggested pull up resistor to 5V standby with 500 to 1Kohm resistor) to disable the main out. The signal can be floated (no connection to the signal), in order to enable the main output.
**==> picture [178 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
System Power supply<br>side 5V standby side<br>Remote On_Off +<br>Remote On_Off -<br>Switch Signal<br>DC RTN<br>**----- End of picture text -----**<br>
**Figure 8. Remote On_Off Connection**
## Remote Sense
**Figure 6. Power Good Connection**
Remote sense feature can be used to compensate for the extra voltage drop on output wires that are connected from the main output terminals, to the load. With wires connected from the remote sense pins, at the same locations as the wires from the main output, the remote sense function can compensate up to 500mV voltage drop. The power supply will not be damaged if the remote sense pins are shorted, or if a reverse/inverted polarity connection is made to the load.
## Voltage/Current Adjustment
**Figure 7. Power Good Time Sequence**
The power supply provides a potentiometer for user to adjust the output voltage in CV mode or to adjust the output current in CC mode. The output voltage is designed to be able to adjust above the normal rated voltage, when the output is adjusted above nominal value, the output power cannot exceed the nominal maximum power (the maximum output current will be reduced accordingly).
## PMBus
The power supply can communicate with the host product, using PMBus version 1.3 protocols. Multiple functions can be realized, such as monitoring the power supply operation status, and editing the power supply operating set-points. See user instruction for detailed control information.
All parameters are specified at 25°C ambient unless otherwise noted. **PSU.deltaww.com (September 2025, Rev. 01.1)**
11
**TECHNICAL DATASHEET**
## **Medical / Industrial AC-DC Power Supply** 2,500 W with 5 V/2 A Standby / MEB-2K5A series
## Current Sharing
The power supply has an active current sharing circuit for the main output; it can realize the output current to be balanced when customer is using up to four power supplies in parallel to achieve higher output power. A one wire current share bus is used to achieve current sharing between units, the current share bus must be connected together among different units (pin 13 of CN602, refer to power supply mechanical drawing and pin assignment). The difference in output voltage can impact the current sharing accuracy, all the units to be paralleled, please use the voltage adjustment function to set the voltage to be ±50 mV of the set value, and the maximum output current set at 80% of rated output current.
## CC/CV mode selection
Pin14 of CN602 can be used to select from constant voltage output mode or constant current output mode, if the pin is left open the output will be default as constant voltage output, if the pin is shorted to ground return, the output will be selected as constant current.
The paralleled units can be connected with or without remote sense function, Figure 9 &10 are typical connection of the parallel connections.
**Figure 9. Parallel Connection with Remote Sense**
**Figure 10. Parallel Connection without Remote Sense**
All parameters are specified at 25°C ambient unless otherwise noted. **PSU.deltaww.com (September 2025, Rev. 01.1)**
12
**TECHNICAL DATASHEET**
2,500 W with 5 V/2 A Standby / MEB-2K5A series
## **Medical / Industrial AC-DC Power Supply**
## **Certificate**
All Delta Medical Power products conform to the European directive 2011/65/EU. ROHS is the abbreviation for “Restriction of the use of certain hazardous substances.
Delta has been certified as meeting the requirement of ISO 13485:2016 and EN ISO 13485:2016 for the design and manufacture of switching power supply and adaptor for medical device.
In addition to a UL Total Certification Program (TCP) approved client laboratory for IEC60950 and IEC60065. Delta also has participated UL Client Test Data Program (CDTP) for IEC 60601.
## **Attention**
Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to PSU.deltaww.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta.
Delta reserves the right to make changes to the information described in the datasheets without notice.
All parameters are specified at 25°C ambient unless otherwise noted. **PSU.deltaww.com (September 2025, Rev. 01.1)**
13
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →