MDS-200APB24 AA
POWER SUPPLY, AC-DC, 24V, 8.33A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: DELTA ELECTRONICS / POWER
- Product type: AC / DC Open Frame Power Supplies
- Product Range: MDS Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Approvals: ITE & Medical
- Power Supply Output Type: Fixed
- Output Current - Output 1: 8.33A
- Output Voltage - Output 1: 24V
- Power Rating (Convection Cooling): 140W
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 66.58 € |
| Current stock | 10+ |
| Lead time | 30 days |
**TECHNICAL DATASHEET** **Medical AC-DC Open Frame Power Supply** 200W 2”x4” High Density / MDS-200APB □ AA ## **MDS-200APB□ AA** ## **Highlights & Features** - Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 - Compliant with IEC 60601-1-2 4th Ed. Requirements - Power Good Signal - 2xMOPP Isolation for Medical Applications - Up to 120W~140W convection, 200W forced air ## **Safety Standards** CB Certified for worldwide use **Model Number:** MDS-200APB☐ AA **Unit Weight:** 200g (0.441lb) **Dimensions (W x L x H):** 50.8 x 101.6 x 35.6mm (2 x 4 x 1.4 inch) ## **General Description** Delta’s MDS-200APB☐ AA internal open frame power supply comes with universal AC input range from 90Vac to 264Vac. Other features include low leakage, Type BF Patient Access Leakage Currents, and electric shock protection compliance with 2 x MOPP requirements. The MDS-200APB☐ AA is certified for EMC standards according to EN 55011 for industrial, scientific and medical (ISM) radio-frequency equipment; and EN 55032 for Industrial Technology Equipment (ITE) radio-frequency equipment. In addition, only recognized Japanese capacitors are used to ensure long product life. The MDS-200APB☐ AA comes with both medical and ITE safety approvals, such as UL/CE/CCC (5,000meters), and CB certification. Designs are compliant with RoHS Directive 2011/65/EU for environmental protection. ## **Model Information** |**Model Number**|**Input Voltage**|**Output Voltage**|**Convection Current Output**|**Forced Air Current Output**| |---|---|---|---|---| |MDS-200APB12AA|90-264Vac|12Vdc|0-10.83A|0-16.67A**| |MDS-200APB24AA||24Vdc|0-5.83A|0-8.33A*| |MDS-200APB36AA||36Vdc|0-3.33A|0-5.56A*| *With 5.5CFM forced air **With 8.5CFM forced air ## **Model Numbering** |MDS||200||A||P||B||☐||AA| |---|---|---|---|---|---|---|---|---|---|---|---|---| |**Delta**||**Max wattage in**||**Family Code**||**Product Type**||**Input Type**||**Output Voltage**||**Revision code**| |**Medical**||**the product**||||||**Code**||||| |**power**<br>**Supply**||**Series.**<br>**Maybe lower at**<br>**some voltage.**||A~Z||P: Open Frame||B: 3pin Class I||12 for 12V<br>24 for 24V<br>36 for 36V||| |||200→200W||||||||||| All parameters are specified at 25°C ambient unless otherwise noted. 1 **www.DeltaPSU.com (July 2019, Rev.01)** **TECHNICAL DATASHEET** **Medical AC-DC Open Frame Power Supply** 200W 2”x4” High Density / MDS-200APB □ AA ## **Specifications** |**Model Number**<br>Input Ratings / Characteristics|MDS-200APB12 AA<br>MDS-200APB24 AA<br>MDS-200APB36 AA|MDS-200APB12 AA<br>MDS-200APB24 AA<br>MDS-200APB36 AA|MDS-200APB12 AA<br>MDS-200APB24 AA<br>MDS-200APB36 AA| |---|---|---|---| |Nominal Input Voltage|100-240Vac||| |Input Voltage Range|90-264Vac||| |Nominal Input Frequency|50-60Hz||| |Input FrequencyRange|47-63Hz||| |Input Current(max)|2.5A||| |Input Surge Voltage(max)|300Vac for 100ms||| |Full load Efficiency (typ.)|91% @ 115Vac/60Hz<br>93% @ 230Vac/50Hz,<br>Reference Fig.1|92% @ 115Vac/60Hz<br>93% @ 230Vac/50Hz,<br>Reference Fig.2|91.5% @ 115Vac/60Hz<br>94% @ 230Vac/50Hz,<br>Reference Fig.3| |Standby Power (max)|0.5W @ 115Vac/60Hz, 230Vac/50Hz||| |Inrush Current(max)|60A@230Vac, cold start||| |Input-PE(protective earth) leakage<br>current(max)|0.1mA @ NC, 0.3mA @ SFC1)||| |Output-PE(protective earth) leakage<br>current for Type BF application<br>(max)|Output-PE(protective earth) leakage<br>0.1mA @ NC, 0.5mA @ SFC1)||| |Power Factor(min)|0.95@115V/50Hz, 230V/50Hz, full load||| 1) NC: normal condition 2) SFC: single fault condition **==> picture [251 x 130] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>90<br>80<br>115Vac<br>70<br>230Vac<br>60<br>50<br>25% 50% 75% 100%<br>Output Load (200W)<br>Efficiency (%)<br>**----- End of picture text -----**<br> **==> picture [249 x 130] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>90<br>115Vac<br>80<br>230Vac<br>70<br>60<br>50<br>25% 50% 75% 100%<br>Output Load(200W)<br>Efficiency (%)<br>**----- End of picture text -----**<br> Fig.1 Efficiency versus output load(MDS-200APB12 AA) Fig.2 Efficiency versus output load(MDS-200APB24 AA) **==> picture [253 x 138] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>90<br>115Vac<br>80<br>230Vac<br>70<br>60<br>50<br>25% 50% 75% 100%<br>Output Load(200W)<br>Efficiency (%)<br>**----- End of picture text -----**<br> Fig.3 Efficiency versus output load(MDS-200APB36 AA) All parameters are specified at 25°C ambient unless otherwise noted. 2 **www.DeltaPSU.com (July 2019, Rev.01)** **TECHNICAL DATASHEET** ## **Medical AC-DC Open Frame Power Supply** 200W 2”x4” High Density / MDS-200APB □ AA Output Ratings / Characteristics |**Model Number**|MDS-200APB12 AA|MDS-200APB24 AA|MDS-200APB36 AA| |---|---|---|---| |Nominal Output Voltage (Vrated)|12V|24V|36V| |Total Regulation(max.)|±3%|±3%|±3%| |Output Power|200W 8.5CFM air<br>Up to 130W convection air|200W 5.5CFM air<br>Up to 140W convection air|200W 5.5CFM air<br>Up to 120W convection| |Line Regulation(max)|±0.5%||| |Load Regulation(max)|±2.5%||| |Ripple& Noise(typ.)|1%pk-pkVrated@Full load||| |Start-upTime(max)|2000ms@115Vac||| |Hold-up Time(min)|12ms@115Vac, tested with<br>130W load|12ms@115Vac, tested with<br>130W load|12ms@115Vac, tested with<br>120W load| |Dynamic Response(Overshoot &<br>Undershoot O/P Voltage)|±5% @50-100% load (Slew Rate: 0.5A/μS, 50% duty cycle @ 10Hz&10KHz)||| |Capacitive load (max)|1000uF @200W<br>1500uF@130W|1000uF @200W<br>1500uF@140W|1000uF @200W<br>1500uF@120W| |Rise time(max)|100ms||| Ripple & Noise measurement circuit All parameters are specified at 25°C ambient unless otherwise noted. **www.DeltaPSU.com (July 2019, Rev.01)** 3 **TECHNICAL DATASHEET** ## **Medical AC-DC Open Frame Power Supply** 200W 2”x4” High Density / MDS-200APB □ AA ## Mechanical |Mechanical|| |---|---| |Case Cover|NA| |Dimensions(W x L x H typ.)|50.8x101.6x35.6mm(2x4x1.4inch)| |Unit Weight|200g(0.441lb)| |Indicator|NA| |CoolingSystem|NA| ## Environment |Environment|| |---|---| |Surrounding Air Temperature<br>Operating|Absolute Max<br>-10°C to+70°C, supported power linearly de-rate from<br>50°C to 50% rated up to 70°C<br>Note: see power de-rating curve| |Storage|-40°C to+85°C| |OperatingHumidity|5-95% RH(Non-Condensing)| |Storage Humidity|5-95% RH(Non-Condensing)| |OperatingAltitude|Upto 5,000 meters(upto 16402 feet or 106-54kPa)| |Shock Test(Non-Operating)|50G, 11ms, 3 shocks for each direction| |Vibration(Operating)|5-500Hz, 2Grms, 15 minute for each three axis| ## Power De-rating curve **==> picture [68 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> MDS-200APB12<br>**----- End of picture text -----**<br> ## **MDS-200APB24** ## **MDS-200APB36** All parameters are specified at 25°C ambient unless otherwise noted. **www.DeltaPSU.com (July 2019, Rev.01)** 4 **TECHNICAL DATASHEET** ## **Medical AC-DC Open Frame Power Supply** 200W 2”x4” High Density / MDS-200APB □ AA ## Protections |Protections|| |---|---| |Overvoltage(max)|125% of rated voltage, Latch Mode| |Overload / Overcurrent (max)|Main output 160% of rated current<br>Hiccup Mode(Non-Latching, Auto-Recovery)| |Over Temperature|Latch Mode| |Short Circuit|Hiccup Mode,<br>(Non-Latching,Auto-Recovery)| ## Reliability |Reliability|| |---|---| |MTBF(Minimum)<br>115Vac, 130W, 35°C, Convection Air Flow(MDS-200APB12 AA)<br>115Vac, 140W, 35°C, Convection Air Flow(MDS-200APB24 AA)<br>115Vac, 120W, 35°C, Convection Air Flow(MDS-200APB36 AA)|800 kHrs based on Telecordia SR-332| |Operating life<br>115Vac, 130W, 25°C, Convection Air Flow(MDS-200APB12 AA)<br>115Vac, 140W, 25°C, Convection Air Flow(MDS-200APB24 AA)<br>115Vac, 120W, 25°C, Convection Air Flow(MDS-200APB36 AA)|26,280Hrs| All parameters are specified at 25°C ambient unless otherwise noted. **www.DeltaPSU.com (July 2019, Rev.01)** 5 **TECHNICAL DATASHEET** **Medical AC-DC Open Frame Power Supply** 200W 2”x4” High Density / MDS-200APB □ AA ## Safety Standards / Directives |Medical Safety||IEC60601-1 2nd and 3.1rd edition CB report| |---|---|---| |||IEC60601-1 edition 3.1rd (2012), EN60601-1 (2006) +| |||A11 + A1 + A12, CAN/CSA-C22.2 NO. 60601-1:14,| |||ANSI/AAMI ES60601-1:2005/(R)2012| |ITE Safety||IEC60950-1 CB report| |||TUV60950-1| |||UL60950-1+CAN/CSA60950-1| |||GB4943.1-2011, GB9254-2008, GB17625.1-2003| |CE||MDD Directive 93/42/EEC| |Environmental||RoHS Directive 2011/65/EU Compliant| |Galvanic Isolation|Input to/Output (2XMOPP)|4000 Vac| ||Input to/Ground(1XMOPP)|1500Vac1)| ||Output to/Ground(1XMOPP)|Output to/Ground(1XMOPP)<br>1500Vac ( Type BF application rated)| 1) PSU can support PoE applications with Primary to FG 2500Vac test. All parameters are specified at 25°C ambient unless otherwise noted. **www.DeltaPSU.com (July 2019, Rev.01)** 6 **TECHNICAL DATASHEET** ## **Medical AC-DC Open Frame Power Supply** 200W 2”x4” High Density / MDS-200APB □ AA ## EMC (Compliant with IEC 60601-1-2 4th Ed. Requirements) |EMC (Compliant with IEC 60601-1-2 4th Ed. Requirements)|| |---|---| |EMC / Emissions|EN55011 & compliant with EN55032,FCC Title<br>47:Class B| |Harmonic Current Emissions<br>IEC61000-3-2|Meet Class D limit| |Immunityto|| |Voltage Flicker<br>IEC61000-3-3|| |Electrostatic Discharge<br>IEC61000-4-2|Level 4 Criteria A1)<br>Air Discharge: 15kV<br>Contact Discharge: 8kV| |Radiated Field<br>IEC61000-4-3|Criteria A1)<br>80MHz-2700MHz, 10V/m AM modulation<br>385MHz-5785MHz, 28V/m Pulse mode and other<br>modulation| |Electrical Fast Transient / Burst<br>IEC61000-4-4|Level 3 Criteria A1):2kV| |Surge<br>IEC61000-4-5|Level 3 Criteria A1)<br>Common Mode3): 2kV<br>Differential Mode4): 1kV| |Conducted<br>IEC61000-4-6|Level 2 Criteria A1)<br>150kHz-80MHz, 3Vrms,6Vrms at ISM bands and<br>Amateur radio bands| |Power Frequency Magnetic Fields<br>IEC61000-4-8|Criteria A1)<br>Magnetic field strength 30A/m| |Voltage Dips<br>IEC61000-4-11|Criteria A1)<br>0% UT, 0.5 cycle (10ms)<br>, 0o/45o/90o/135o/180o/225o/270o/315o/360o<br>Criteria B2)<br>0% UT, 1 cycle (20ms), 0o<br>Criteria B2)<br>70% UT, 25 cycle (500ms), 0o<br>Criteria B2)<br>0% UT, 250 cycle (5000ms), 0o| - 1) Criteria A: Normal performance within the specification limits - 2) Criteria B: Output out of regulation, or shuts down during test. Automatically restore to normal operation after test. - 3) Asymmetrical: Common mode (Line to earth) - 4) Symmetrical: Differential mode (Line to line) All parameters are specified at 25°C ambient unless otherwise noted. **www.DeltaPSU.com (July 2019, Rev.01)** 7 ## **TECHNICAL DATASHEET Medical AC-DC Open Frame Power Supply** 200W 2”x4” High Density / MDS-200APB □ AA ## **Dimensions** **W x L x H:** 50.8 x 101.6 x 35.6 mm Mechanical drawing (3Pin input type) **MDS-200APB12 AA** ## **MDS-200APB24 AA & MDS-200APB36 AA** ## **Notes** ## ― Dimensions are in mm - CN1 mates with Molex housing 26-03-4030 and Molex series 6838 crimp terminals. Input Line can also be connected to Neutral, and Input Neutral can be connected to Line. - CN101 mates with JST housing VHR-4N and JST terminal SVH-41T-P1.1. - CN102 mates with Molex housing 0874390200 and Molex 874210000 crimp terminals. - CN3: PINGOOD JP-13T or equivalent mate with KST FDFNYD1-187 or other applicable connectors - Two mounting points in mechanical drawing need to be connected to system earth case together, Protective bonding conductor from the end product protective earth terminal (if any) can be tied to CN3 for open frame model. All parameters are specified at 25°C ambient unless otherwise noted. **www.DeltaPSU.com (July 2019, Rev.01)** 8 **TECHNICAL DATASHEET** **Medical AC-DC Open Frame Power Supply** 200W 2”x4” High Density / MDS-200APB □ AA ## **Functions** ## Start-up Time The time required for the output voltage to reach 90% of its set value, after the input voltage is applied. ## Rise Time The time required for the output voltage to change from 10% to 90% of its set value. ## Hold-up Time Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time required for the output to reach 90% of its set value, after the input voltage is removed. ## **■Graph illustrating the Start-up Time, Rise Time, and Hold-up Time** All parameters are specified at 25°C ambient unless otherwise noted. **www.DeltaPSU.com (July 2019, Rev.01)** 9 **TECHNICAL DATASHEET** ## **Medical AC-DC Open Frame Power Supply** 200W 2”x4” High Density / MDS-200APB □ AA ## Dynamic Response The power supply output voltage will remain within ±5% of its steady state value, when subjected to a dynamic load 50 to 100% of its rated current. ■ 50 to 100% Load ## Short Circuit Protection The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. ## Inrush Current Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. Overload & Overcurrent Protections The power supply’s Overload (OLP) and Overcurrent (OCP) Protections will be activated before output current under 160% of IO (Max load). Upon such occurrence, VO will start to drop. Once the power supply has reached its maximum power limit, the protection will be activated and the power supply will go into “Hiccup mode” (Auto-Recovery). The power supply will recover once the fault condition causing the OLP and OCP is removed and IO is back within the specified limit. Additionally, if the Iout is <160% but >100% for a prolong period of time (depending on the load), the Over Temperature Protection (OTP) will be activated due to high temperature on critical components. Then, the power supply will be latched off, and require recycling of input voltage to restart it. ## Over Temperature Protection ## Overvoltage Protection The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 6 under “Protections”. Power supply will latch off, and require removal/re-application of input AC voltage in order to restart. As mentioned above, the power supply also has Over Temperature Protection (OTP). This is activated when the overload condition persists for an extended duration and the output current is below the overload trigger point but >100% load. In the event of a higher operating temperature condition at 100% load, the power supply will run into OTP when the surrounding air temperature is higher than the operating temperature. When activated, the output voltage will go into latch mode until the input voltage is removed; then, reapplied, and the surrounding air temperature drops to its normal operating temperature. All parameters are specified at 25°C ambient unless otherwise noted. **www.DeltaPSU.com (July 2019, Rev.01)** 10 **TECHNICAL DATASHEET** **Medical AC-DC Open Frame Power Supply** 200W 2”x4” High Density / MDS-200APB □ AA ## Power Good Power Good+ pin is an open collector transistor (40V/600mA rating). A resistor (suggested value 20Kohm, 1/8W) can be added between output pin (or, other available pull-up voltage that is no greater than 30V) and the Power Good+ pin (refer to figure below). Value of pull-up resistor may have to be adjusted, depending on voltage used, and other end-use conditions of the Power Good+ pin connection to the product. When AC input is on, Power Good+ pin will be high. When AC input is off, Power Good+ pin will be low. There will be a minimum of 5 milliseconds (with 120W convection output power) between the time the power good goes to low level, and the time when the output reaches 90% of its rated value. All parameters are specified at 25°C ambient unless otherwise noted. **www.DeltaPSU.com (July 2019, Rev.01)** 11 **TECHNICAL DATASHEET** **Medical AC-DC Open Frame Power Supply** 200W 2”x4” High Density / MDS-200APB □ AA ## **Certificate** All Delta Medical Power products conform to the European directive 2011/65/EU. RoHS is the abbreviation for “Restriction of the use of certain hazardous substances Delta has been certified as meeting the requirement of ISO 13485: 2003 and EN ISO 13485:2012 for the design and manufacture of switching power supply and adaptor for medical device. In addition to a UL Total Certification Program (TCP) approved client laboratory for IEC60950 and IEC60065. Delta also has participated UL Client Test Data Program (CDTP) for IEC 60601 ## Attention Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. All parameters are specified at 25°C ambient unless otherwise noted. **www.DeltaPSU.com (July 2019, Rev.01)** 12
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →