Image not available
Illustrative purposes only
MDR-40-24
AC/DC DIN Rail Power Supply (PSU), ITE, 1 Output, 40.8 W, 24 VDC, 1.7 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type:
- No. of Outputs:1 Output; Output Power Max:40.8W; Output Voltage - Output 1:24V; Output Current - Output 1:1.7A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - O
- SVHC: No SVHC (25-Jun-2025)
- Product Range: MDR-40 Series
- No. of Outputs: 1 Output
- Output Power Max: 40.8W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 1.7A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 24.75 € |
| Current stock | 100+ |
| Lead time | 30 days |
## **- MDR 40 series** ## MEAN WELL 40W Single Output Industrial DIN Rail Power Supply **- series** ~~a~~ ## ■ |**SPECIFICATION**<br>**www.**<br>**ID 2000000000**<br>**tuv.com**<br>Al.;<br>© Hl ~~Ai~~cBce<br>c<br>US c<br>US<br>Raato0<br>Guy|**SPECIFICATION**<br>**www.**<br>**ID 2000000000**<br>**tuv.com**<br>Al.;<br>© Hl ~~Ai~~cBce<br>c<br>US c<br>US<br>Raato0<br>Guy||c<br>US c|Al.;<br>© Hl<br>c<br>US<br>Raato0|**www.**<br>**ID 2000000000**<br>**tuv.com**<br>Hl ~~Ai~~cBce<br>Guy| |---|---|---|---|---|---| |**MDR-40-5**<br>**MDR-40-12**<br>**MDR-40-24**<br>**MDR-40-48**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**Note.5**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**DC OK SIGNAL**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>5V<br>12V<br>24V<br>48V<br>6A<br>3.33A<br>1.7A<br>0.83A<br>0 ~ 6A<br>0 ~ 3.33A<br>0 ~ 1.7A<br>0 ~ 0.83A<br>30W<br>40W<br>40.8W<br>39.8W<br>80mVp-p<br>120mVp-p<br>150mVp-p<br>24 ~ 30V<br>200mVp-p<br>48 ~ 56V<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>12 ~ 15V<br>5 ~ 6V<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load<br>50ms/230VAC 20ms/115VAC at full load<br>85 ~ 264VAC 120 ~ 370VDC<br>47 ~ 63Hz<br>78%<br>86%<br>88%<br>88%<br>1.1A/115VAC 0.7A/230VAC<br>COLD START 30A/115VAC 60A/230VAC<br>105 ~ 150% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed<br>6.25 ~ 7.25V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>15.6 ~ 18V<br>31.2 ~ 36V<br>57.6 ~ 64.8V<br>-20 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>Relay contact rating(max.): 30V/1A resistive<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6<br>301.7K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>℃<br>℃<br>℃<br>UL508, UL60950-1, TUV EN60950-1,<br>,<br>Class I, Div. 2 Group A, B, C, D Hazardous Locations T4,EAC TP TC 004<br>BSMI CNS14336-1 approved<br>Compliance to EN55011, EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3,<br>Class B<br>EAC TP TC 020, CNS13438<br>Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A, EAC TP TC 020<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**SAFETY &**<br>**FUNCTION**<br>**EMC**<br>**(Note 4)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>40*90*100mm (W*H*D)<br>0.3Kg; 42pcs/13.6Kg/0.82CUFT<br>**LEAKAGE CURRENT**<br><1mA / 240VAC<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ ofambienttemperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Awww.meanwell.com)<br>5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>6. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higherthan 2000m(6500ft),||**MDR-40-5**|**MDR-40-12**|**MDR-40-24**|**MDR-40-48**| ||**DC VOLTAGE**|5V|12V|24V|48V| ||**RATED CURRENT**|6A|3.33A|1.7A|0.83A| ||**CURRENT RANGE**|0 ~ 6A|0 ~ 3.33A|0 ~ 1.7A|0 ~ 0.83A| ||**RATED POWER**|30W|40W|40.8W|39.8W| ||**RIPPLE & NOISE (max.) Note.2**|80mVp-p|120mVp-p|150mVp-p|200mVp-p| ||**VOLTAGE ADJ. RANGE**|5 ~ 6V|12 ~ 15V|24 ~ 30V|48 ~ 56V| ||**VOLTAGE TOLERANCE Note.3**|±2.0%|±1.0%|±1.0%|±1.0%| ||**LINE REGULATION**|±1.0%|±1.0%|±1.0%|±1.0%| ||**LOAD REGULATION**|±1.0%|±1.0%|±1.0%|±1.0%| ||**SETUP, RISE TIME**<br>**Note.5**|500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load|||| ||**HOLD UP TIME (Typ.)**|50ms/230VAC 20ms/115VAC at full load|||| ||**VOLTAGE RANGE**|85 ~ 264VAC 120 ~ 370VDC|||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||| ||**EFFICIENCY (Typ.)**|78%|86%|88%|88%| ||**AC CURRENT (Typ.)**|1.1A/115VAC 0.7A/230VAC|||| ||**INRUSH CURRENT (Typ.)**|COLD START 30A/115VAC 60A/230VAC|||| ||**LEAKAGE CURRENT**|<1mA / 240VAC|||| ||**OVERLOAD**|105 ~ 150% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed|||| ||**OVER VOLTAGE**|6.25 ~ 7.25V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>15.6 ~ 18V<br>31.2 ~ 36V<br>57.6 ~ 64.8V|||| ||**DC OK SIGNAL**|Relay contact rating(max.): 30V/1A resistive|||| ||**WORKING TEMP.**|-20 ~ +70<br>(Refer to "Derating Curve")<br>℃|||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH<br>℃|||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)|||| ||**VIBRATION**|Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6|||| ||**SAFETY STANDARDS**|UL508, UL60950-1, TUV EN60950-1,<br>,<br>Class I, Div. 2 Group A, B, C, D Hazardous Locations T4,EAC TP TC 004<br>BSMI CNS14336-1 approved|||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC|||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃|||| ||**EMC EMISSION**|Compliance to EN55011, EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3,<br>Class B<br>EAC TP TC 020, CNS13438|||| ||**EMC IMMUNITY**|Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A, EAC TP TC 020|||| ||**MTBF**|301.7K hrs min. MIL-HDBK-217F (25<br>)<br>℃|||| ||**DIMENSION**|40*90*100mm (W*H*D)|||| ||**PACKING**|0.3Kg; 42pcs/13.6Kg/0.82CUFT|||| ||℃<br>℃<br>℃<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ ofambienttemperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance<br>: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Awww.meanwell.com)<br>5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>6. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higherthan 2000m(6500ft),||||| ## **SPECIFICATION** _File Name:MDR-40-SPEC 2018-01-12_ **- MDR 40 series** 40W Single Output Industrial DIN Rail Power Supply **==> picture [478 x 635] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Case No.962A Unit:mm<br>35 40 100<br>5 5 5 5 5<br>+V +V -V -V<br>DC OK<br>DC OK<br>+<br>+V ADJ<br>N L<br>7.5 7.5<br>Install DIN rail TS35/7.5 or TS35/15<br>Block Diagram<br>fosc : 60KHz<br>DC OK<br>RECTIFIERS RECTIFIERS<br>EMI POWER +V<br>I/P & &<br>FILTER SWITCHING -V<br>FILTER FILTER<br>O.C.P.<br>DETECTION<br>FG<br>CIRCUIT<br>O.L.P. CONTROL<br>O.V.P.<br>DC OK Relay Contact<br>Contact Close PSU turns on / DC OK.<br>Contact Open PSU turns off / DC Fail.<br>Contact Ratings (max.) 30V/1A resistive load.<br>Derating Curve Output Derating VS Input Voltage<br>100<br>100<br>90<br>80<br>80<br>60 70<br>60<br>40<br>50<br>20<br>40<br>-20 0 10 20 30 45 55 60 70 (VERTICAL) 85 95 100 115 120 140 160 180 200 220 240 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%) LOAD (%)<br>90<br>**----- End of picture text -----**<br> _File Name:MDR-40-SPEC 2018-01-12_
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →