Image not available
Illustrative purposes only
MCST1290AS
SSR-INDUSTRIAL MT. PM SOFT-START SS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SENSATA-CRYDOM / PARTNER STOCK
- Product type:
- SVHC: No SVHC (07-Nov-2024)
- Product Range: MCS Series
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 166.7 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Crydom** _See full Datasheet below..._ ## **BUY NOW** ## **BUY NOW** masterelectronics.com & onlinecomponents.com are **authorized** e-commerce distributors of electronic components. ## **MCS Series** - Microprocessor based soft-start / soft-stop controller - Ratings from 25A to 90A @ 48-530 VAC - Low-voltage, current, or potentiometer control - Output status indicator - Adjustable ramp rates ## **PRODUCT SELECTION** |**Line Voltage**|**25 A**|**50 A**|**90 A**| |---|---|---|---| |120 Vrms|MCST1225|MCST1250|MCST1290| |240 Vrms|MCST2425|MCST2450|MCST2490| |480 Vrms|MCST4825|MCST4850|MCST4890| ## **AVAILABLE OPTIONS** ## **OUTPUT SPECIFICATIONS (voltage)** |**Description**|**120 VAC**|**240 VAC**|**480 VAC**| |---|---|---|---| |Operating Voltage (47-63Hz) [Vrms]|48-140|180-280|300-530| |Transient Overvoltage [Vpk]|400|600|1200| |Maximum Off-State Leakage Current @ Rated Voltage [mArms]|5|7|12| |Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]|200|200|200| |**OUTPUT SPECIFICATIONS (current)**|||| |**Description**|**25 A**|**50 A**|**90 A**| |Maximum Load Current [Arms]|25|50|90| |Minimum Load Current [mArms]|150|150|150| |Maximum Surge Current (16.6ms) [Apk]|250|625|1200| |Maximum On-State Voltage Drop @ Rated Current [Vpk]|1.6|1.6|1.6| |Thermal Resistance Junction to Case (Rjc) [°C/W]|1.02|0.63|0.28| |Maximum I²t for Fusing (8.3 msec) [A²sec]|260|1620|6000| ## **INPUT SPECIFICATIONS (1)** ## **DC Control** |**Description**|**DC Control**| |---|---| |Control Voltage Range (VDC)|8-32| |Input Current Range [mA] [P1]|28-30| |Nominal Input Impedance [Ohms] [P3]|30K| |Control Must Operate Voltage"On"[VDC][P3]|5-32| |Control Must Release Voltage"Off"[VDC][P3]|0-4| |Input Current [mA][P3]|0-2.6| |Analog Range Option A [VDC][P4]|0.5-5| |Analog Range Option B [VDC][P4]|1.25-7| |Analog Range Option C [VDC][P4]|2-10| |Analog Range Option D [VDC][P4]|4-20| |Nominal Input Impedance Option A,B,C[ohms][P4]|20K| |Nominal Input Impedance Option D [ohms][P4]|220| ## **GENERAL SPECIFICATIONS** |**Description**|**Parameters**| |---|---| |Minimum Power Factor (with Maximum Load)|0.5| |Dielectric Strength, Input/Output/Base (50/60Hz)|4000 Vrms| |Minimum Insulation Resistance(@ 500 V DC)|109Ohm| |Maximum Capacitance, Input/Output|10 pF| |Ambient Operating Temperature Range|-20 to 80°C| |Ambient Storage Temperature Range|-40 to 125°C| |Weight (typical)|3.0 oz (86.5g)| |Encapsulation|Thermally conductive Epoxy| |Terminals-Power|Screws and Saddle Clamps Furnished, Unmounted| |Terminals-Control|Barrier Strip Screw Terminals| |Recommended Terminal Screw Torque Range:|8-32 Screws -20 in. lbs.(Screws dry without grase)| ||Input Connections via Screw Type Barrier Strip| ## **GENERAL NOTES** - 1) Voltages are reference to GND (Ground = 0 VDC) P2 ## **OUTPUT STATUS FUNCTIONS** |**Conditions**|**LED Status**| |---|---| |Initial Logic Supply On|Flash Once| |Load Voltage Missing / Load Open (w/control P3 disabled)|Flash Once Intermittenly| |Load Voltage Missing / Load Open (w/control P3 enabled))|Off| |Ramp Time (Soft Start upon P3 Enabled)|Off to Bright| |Ramp Time (Soft Start upon P3 Disabled)|Bright to Off| |Output ON (Normally Steady Operation)|On| ## **THERMAL DERATE INFORMATION** ## **MECHANICAL SPECIFICATIONS** ## **RAMP TIME IN SECONDS** ## **AGENCY APPROVALS** **==> picture [47 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> UL E116949<br>**----- End of picture text -----**<br> **==> picture [47 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Rev. 050311<br>**----- End of picture text -----**<br> A WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA/ AVISO RISK OF MATERIAL DAMAGE AND HOT RISQUE DE DOMMAGE MATERIEL ET DE GEFAHR VON MATERIALSCHADEN UND ENCLOSURE SURCHAUFFE DU BOITIER GEHAUSEERHITZUNG **==> picture [511 x 614] intentionally omitted <==** **----- Start of picture text -----**<br> + The product's side panels may be hot, allow «Les panneaux latéraux du produit peuvent étre * Die Seitenwande k6nnen hei sein. Lassen Sie<br>the product to cool before touching. chauds. Laisser le produit refroidir avant de le das Produkt abkihlen, bevor Sie es beriihren.<br>* Follow proper mounting instructions including | toucher. * Beachten Sie die Montageanweisungen,<br>torque values. * Respecter les consignes de montage, et « Fuhren Sie keine Fliissigkeiten oder<br>* Do not allow liquids orforeign objects to enter notamment les couples de serrage. Fremdk6rper in das Produkt ein.<br>this product. * Ne pas laisser péneétrer de liquide ni de corps<br>étrangers a l'intérieur du produit.<br>Failureserious to follow these instructions can result in| LGee tosis- corperciet de cette directicraves cursest entrainer,en [Dieie NichtbeachtungNi dieseri Anweisungi kann<br>injury, or equipment damage. dommages matériels. zur Folge haben.<br>RIESGO DE DANOS MATERIALES Y DE : RISCO DE DANO MATERIAL E DE AQUECIMENTO<br>SOBRECALENTAMIENTO DE LA UNIDAD Spal DE RAREMATERIALTE DANVOLVERO<br>* Os paineéis laterais do produto podem estar<br>* Los paneles laterales de! producto pueden *| pannelli laterali dell'apparecchio possono quentes; dé tempo ao produto para arrefecer<br>over calentes. Esperar que el producto se scottare; lasciar quindi raffreddare il prodotto antes de lhe tocar.<br>i enfrie antes de tocarlo. . prima di toccarlo. * Siga devidamente as instrugdes de montagem.<br> aaa = wiles - montaje, yen | « Sequire le istruzioni di montaggio corrette. * Nao permita a entrada de liquidos e de objectos<br>* PaISUIA AOS PALES de ApTe arto. * Non far entrare liquidi o oggetti estranei in questo estranhos no produto.<br>No dejar que penetren liquidos 0 cuerpos apparecchio<br>extrafos en el producto. ;<br>. . La mancata osservanza di questa precauzione pud | A nado observancia destas precaucdées pode<br>Si no se respetan estas precauciones pueden | causare gravi rischi per I'incolumita personale o provocar a morte, terimanlos Annes be<br>producirse graves lesiones, dafios materiales. | qannj alle apparecchiature. danos materais.<br>A DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / PERIGO<br>HAZARD OF RIESGO DE RISQUE DE GEFAHR EINES RISCHIO DI RISCO DE<br>ELECTRIC DESCARGA DESCHARGE ELEKTRISCHE SCOSSA DESCARGA i<br>SHOCK, ELECTRICA O ELECTRIQUE N SCHLAGES ELETTRICA O ELETTRICA OU H<br>EXPLOSION, EXPLOSION. OU EXPLOSION ODER EINER DELL’ESPLOSI EXPLOSAO H<br>OR ARC FLASH. * Desconectar « Eteindre EXPLOSION. ONE. « Desconectar<br>« Disconnect all todos los toutes les « Stellen Sie « Spenga tutta 0 equipamento H<br>power before suministros de sources Jeglichen 'alimentazion de toda a i<br>installing or energia a este d'énergie de Strom ab, der e che fornisce energia antes<br>working with equipo antes cet appareil dieses Gerat questa de instalar ou I<br>this equipment. de trabajar avant de versorgt, bevor apparecchiatu trabalhar com |<br>* Verify: fa conVerificereste todequipo. dessustravailler deicet SieGert an Arbeiten dem ralavorare prima a questadel esteto equipamen |<br>connectionsand replace all © lasVerificar conexionestodas appareilP i * durchfihrenVor der lni « Verificar todas<br>covers before y colocar todas « Vérifier tous Inbetriebnahme * Verificare tutti as conexdes e |<br>turning on las tapas antes connections, et alle Anschitisse i collegamenti recolocar todas<br>power. de energizer remettre tous iiberpriifen und e sostituire as tampas<br>Failure to foll el equipo. couverts en alle Gehauseteile tutte le coperture antesde religar<br>}is ure to follow olace avant de montieren. prima della 0 equipamento<br>iresultinstrucune in t ions deathions wiwill deeIincumplimiento sine De non-suivimeme sous de sull'alimentazia one S nfo araiasi ||<br>or serious injury. Instrucciones ces instructions Unterlassung L'omissione di s leans soe8 |<br>puedeed provocar provoquera la dieser seguire= ae queste Pou lesées sérias.<br>la muerte o mort ou des Anweisungen istruz ioni<br>lesiones serias. lésions sérieuses kénnen zum provochera la<br>sérieuses. Tode oder zu morte o di<br>schweren lesioni serie<br>Verletzungen<br>fiihren.<br>res}<br>A brand of of<br> not forget to visit us at: forget to visit us at: to visit us at: visit us at: us at: at: www.crydom.com 7<br> © 2011 CrydomInc. 2011 CrydomInc. Specifications subject to change change without notice. =<br>**----- End of picture text -----**<br> res} A brand of of Do not forget to visit us at: forget to visit us at: to visit us at: visit us at: us at: at: www.crydom.com 7 Copyright © 2011 CrydomInc. 2011 CrydomInc. Specifications subject to change change without notice. = **ANNEX - ENVIROMENTAL INFORMATION**
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →