MCE03US48-P
AC/DC PCB Mount Power Supply (PSU), Open Frame, Medical, 1 Output, 3 W, 48 VDC, 63 mA
- Manufacturer: XP POWER
- Product type: AC / DC PCB Mount Power Supplies
- SVHC: No SVHC (15-Jan-2018)
- Depth: 38.1mm
- Width: 16.5mm
- Height: 16.5mm
- Product Range: MCE03 Series
- No. of Outputs: 1 Output
- Output Power Max: 3W
- Input Voltage VAC: 80V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 63mA
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 48VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: Medical
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 7.0 € |
| Current stock | 10+ |
| Lead time | 30 days |
AC-DC POWER SUPPLIES ## MCE03 Series ## 3W The MCE03 series of PCB mount single output AC-DC medical power supplies delivers a power output of 3W and offers single output voltages ranging from 3.3V to 48VDC. The MCE03 series, which is available in open-frame and encapsulated mechanical formats, is specifically designed for medical applications with 2 x MOPP isolation and is approved for Class II applications. With world-wide medical safety approvals, class B compliance for conducted and radiated emissions, high efficiency, high reliability, 4kVAC isolation, the MCE series benefits system designers with easy integration into a wide range of BF rated medical applications including imaging, patient treatment, surgical equipment and home healthcare applications. ## **Applications** ## **Features** • Single outputs 3.3V to 48VDC —— - Single outputs 3.3V to 48VDC • Input range 80 to 264VAC **==> picture [121 x 59] intentionally omitted <==** **----- Start of picture text -----**<br> ) ©<br>Healthcare Home Medical<br>Healthcare Diagnostic<br>**----- End of picture text -----**<br> - Available in open frame and encapsulated formats - High efficiency, up to 81% **==> picture [53 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions<br>**----- End of picture text -----**<br> - 4kVAC input to output isolation **==> picture [28 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> MCE03:<br>**----- End of picture text -----**<br> - Class B conducted and radiated emissions 1.60 x 0.75 x 0.75” (40.6 x 19.1 x 19.1mm) - IEC 60601-1 medical safety agency approvals, 2 x MOPP - IEC class II insulation rating - -25°C to +70°C operating temperature ## MCE03-P: 1.50 x 0.65 x 0.65” (38.1 x 16.5 x 16.5mm) - Overvoltage, overload and short circuit protection ## **Models & Ratings** |Model Number(1)<br>MCE03US03|Output Voltage<br>3.3VDC|Output Current<br>910mA|Efficiency(2)<br>75%|Output Power<br>3W| |---|---|---|---|---| |MCE03US05|5.0VDC|600mA|79%|3W| |MCE03US09|9.0VDC|333mA|79%|3W| |MCE03US12|12.0VDC|250mA|80%|3W| |MCE03US15|15.0VDC|200mA|80%|3W| |MCE03US24|24.0VDC|125mA|81%|3W| |MCE03US48|48.0VDC|63mA|80%|3W| Notes: 1. For Open Frame version add suffix -P to model number, e.g. MCE03US12-P. 2. Typical efficiency at 115VAC and full load. AC-DC POWER SUPPLIES ## MCE03 Series ## **Summary** **==> picture [540 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Input Voltage Range|80||264|VAC|Derate from 100% at 90 VAC to 90% at 80VAC| |No Load Input Power|||0.3|W|| |Effciency||80||%|Model dependent, see Models & Ratings| |Operating Temperature|-25||+70|°C|Derate output linearly from 100% at 50°C to 50% at 70°C| |EMC|EN55011 Level B Conducted & Radiated, EN61000-3-2, EN61000-3-3, EN60601-1-2||||| |Safety Approvals|IEC60601-1, EN60601-1, ES60601-1||||| ## **Input** |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Input Voltage Range|80||264|VAC|Derate from 100% at 90VAC to 90% at 80VAC| |Input Frequency|47||63|Hz|| |Input Current - Full Load||0.06/0.04||A rms|At 115/230VAC| |No Load Input Power|||0.3|W|| |Inrush Current|||40|A|At 230VAC, cold start 25°C| |Earth Leakage Current|||||Class II construction no earth| |Input Protection|External T1.0 A/300 VAC fuse required in line and neutral||||| ## **Output** **==> picture [540 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Output Voltage|3.3||48|VDC|| |Initial Set Accuracy|||3/2|%|3% for 3V3 & 5V models, 2% for others at 50% load| |Minimum Load|0|||A|No minimum load required| |Line Regulation|||1|%|| |Load Regulation|||6/4||6% for 3V3 & 5V models, 4% for other models| |Start Up Delay|||2|s|| |Start Up Rise Time|||35|ms|| |Hold Up Time|8|14||ms|At full load and 115VAC| |Transient Response|||4|%|Deviation, recovery within 1% in less than 500μs for a 25% load<br>change| |Ripple & Noise|||100|mV pk-pk|3.3-9V models, 20MHz bandwidth| ||||1|% pk-pk|12V to 15V models, 20MHz bandwidth| ||||1.5|% pk-pk|24V to 48V models, 20MHz bandwidth| |Patient Leakage Current|||65|μA|At 264VAC, 60Hz| |Overvoltage Protection|115||145|% Vnom|220% typical for 3V3 model, auto recovery| |Overload Protection|110||190|%|| |Short Circuit Protection|||||Trip & Restart (hiccup mode)| |Temperature Coeffcient|||0.05|%/°C|| 2 AC-DC POWER SUPPLIES ## MCE03 Series ## **General** |Characteristic<br>Efficiency|Minimum|Typical<br>80|Maximum|Units<br>%|Notes & Conditions<br>Model dependent| |---|---|---|---|---|---| |Isolation: Input to Output|4000|||VAC|2 x MOPP, suitable for BF applications| |Switching Frequency|17||75|kHz|Varies with load| |Power Density|||4.7|W/in3|For ‘-P’ version| |Mean Time Between Failure|550|600||khrs|MIL-HDBK-217F, +25°C GB| |Weight||0.025 (10)||lb (g)|Open frame versions (-P)| |||0.067 (30)|||Encapsulated version| ## **Environmental** |Characteristic<br>Operating Temperature|Minimum<br>-25|Typical|Maximum<br>+70|Units<br>°C|Notes & Conditions<br>Derate output linearly from 100% at 50°C to 50% at 70°C| |---|---|---|---|---|---| |Storage Temperature|-40||+85|°C|| |Cooling|Convection-cooled||||| |Humidity|||95|%RH|Non-condensing| |Operating Altitude|||5000|m|| |Shock|IEC68-2-27, 30g, 11ms half sine, 3 times in each of 6 axes||||| |Vibration|IEC68-2-6, 2g, 10Hz to 500kHz, 10 mins/cycle, 60 mins each cycle||||| ||||||| ## **Efficiency Graphs** ## MCE03US12-P ## MCE03US24-P **==> picture [510 x 93] intentionally omitted <==** **----- Start of picture text -----**<br> 100% 100%<br>80% 80%<br>60% 115 VAC 60% 115 VAC<br>230 VAC 230 VAC<br>40% 40%<br>20% 20%<br> 0% 0%<br>10 20 30 40 50 60 70 80 90 100 10 20 30 40 50 60 70 80 90 100<br>Load (%) Load (%)<br>Efficiency<br>**----- End of picture text -----**<br> ## **EMC: Emissions** |Phenomenon<br>Conducted|Standard<br>EN55011|Test Level<br>Class B|Notes & Conditions<br>If output is connected to ground, additional external components will<br>be required. See application notes| |---|---|---|---| |Radiated|EN55011|Class B|| |Harmonic Current|EN61000-3-2|Class A|| |Voltage Flicker|EN61000-3-3||| 3 AC-DC POWER SUPPLIES ## MCE03 Series ## **EMC: Immunity** |Phenomenon<br>Medical|Standard<br>EN60601-1-2|Test Level<br>As below|Criteria<br>As below|Notes & Conditions| |---|---|---|---|---| |ESD Immunity|EN61000-4-2|±8kV contact,<br>±15kV air discharge|A|| |Radiated Immunity|EN61000-4-3|10 V/m|A|| |EFT/Burst|EN61000-4-4|3|A|| |Surge|EN61000-4-5|2|A|Line to line| |Conducted|EN61000-4-6|10Vrms|A|| |Magnetic Fields|EN61000-4-8|30A/m|A|| |Dips and Interruptions|EN61000-4-11<br>(115VAC)|70% UT(80.5VAC) for 100ms|A|| |||40% UT(46VAC) for 200ms|B|| |||<5% UT(0VAC) for 10ms|A|| |||<5% UT(0VAC) for 5000ms|B|| ||EN61000-4-11<br>(230VAC)|70% UT(161VAC) for 100 ms|A|| |||40% UT(92VAC) for 200ms|A|| |||<5% UT(0VAC) for 10ms|A|| |||<5% UT(0VAC) for 5000ms|B|| ## **Safety Approvals** |Certification<br>CB|Standard<br>IEC60601-1|Notes & Conditions<br>Medical, 2 x MOPP| |---|---|---| |UL|ES60601-1/CSA-C22.2 No.60601-1:14|Medical, 2 x MOPP| |TUV|EN60601-1|Medical, 2 x MOPP| |CE|Meets all applicable directives|| |UKCA|Meets all applicable legislation|| ## **Application Notes** ## EMC with output grounded EMC with output grounded. This product is designed for class II operation, but if there is a requirement to connect the output to ground then additional components as shown below can be added to improve emissions. **==> picture [31 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> MCE03<br>**----- End of picture text -----**<br> Suggested value - C: X2 cap, 0.22µF/275V, 10% MKP HJC. - L: CMCK DIP UU-9.8 Φ0.27*95T 17.6mH (min) 4 AC-DC POWER SUPPLIES ## MCE03 Series ## **Mechanical Details** Encapsulated **==> picture [462 x 537] intentionally omitted <==** **----- Start of picture text -----**<br> 1.60 40.6<br>0.200 5.08 1.100 27.94 0.100 2.54<br>0.100 2.54 1.60 40.6<br>TOP VIEW LAYOUT PATTERN<br>TOP VIEW<br>1.1mm PLATED THROUGH HOLE<br>1.6mm PAD SIZE<br>Pin Connections<br>1 2 3 4<br>Pin Single<br>0.025 0.64 1 ACL<br>2 ACN<br>3 +Vout<br>4 -Vout<br>1.50 38.1<br>1.50 38.1<br>LAYOUT PATTERN<br>TOP VIEW<br>1 2 3 4<br>1.1mm PLATED THROUGH HOLE<br>0.05 1.3 1.6mm PAD SIZE<br>0.200 5.08 1.100 27.94 0.100 2.54<br>19.1 19.1<br>10.73 0.75 10.5 0.75<br>0.423 0.41<br>19.1<br>0.75<br>4.8<br>0.19<br>6.0 16.5 16.5<br>0.24 0.65 9.2 0.65<br>0.36<br>4.8 max<br>max max<br>0.19 14.0 2.5 16.5<br>0.55 0.10<br>0.65<br>**----- End of picture text -----**<br> Open Frame (-P) ## **Notes:** 1. Dimensions in inches (mm). 2. Weight: Open frame versions (-P): 0.025lbs (10g) Encapsulated: 0.067lbs (30g) 3. Tolerances: x.xx = ± 0.02 (x.x = ± 0.5) x.xxx = ± 0.01 (x.xx = ± 0.25) **==> picture [148 x 49] intentionally omitted <==** 5 24 May 2023
Updated at June 8, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →