Image not available
Illustrative purposes only
M850-MP1
Digital Panel Meter, M850, Blue LED, 12 Digits, Multifunction, 48-570V, 6
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: HOBUT
- Product type: Digital Panel Meters
- No. of Digits / Alpha:12; Meter Function:Current, Voltage, Frequency, Power, Energy; Meter Range:-; Digit Height:14.2mm; Panel Cutout Height:92mm; Panel Cutout Width:92mm; Supply V
- SVHC: No SVHC (25-Jun-2025)
- Meter Range: -
- Digit Height: 14.2mm
- Product Range: -
- Meter Function: Current, Voltage, Frequency, Power, Energy
- Panel Cutout Width: 92mm
- Supply Voltage Max: 570VAC
- Supply Voltage Min: 28VAC
- Panel Cutout Height: 92mm
- No. of Digits / Alpha: 12
- Operating Temperature Max: 60°C
- Operating Temperature Min: 0°C
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 148.4 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **M850 MULTIFUNCTION METERS** ## **DESCRIPTION** The new range of Hobut multifunction panel meters feature 96 x 96mm sizes complete with unique blue LED screen, which can be seen in direct sunlight. The range is easy to use, features user-programmable CT & VT ratios, and can be used on any single or 3 phase system with any input voltage without re-programming. ## **APPLICATION** The range is a cost effective replacement for traditional panel meters and is suitable for low, medium and high voltage control panels, gensets, building management systems, power management and more. ## **RANGE** ## **ORDERING INFORMATION** **==> picture [249 x 171] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |STANDARD FUNCTIONS:| |Phase Voltage (V)|Power Factor (PF)| |Phase to Neutral Voltage (V)|Instantaneous Amp Demand| |Phase Current (I)|Instantaneous Watt Demand| |Frequency (Hz)|Instantaneous VA Demand| |Active Power (W)|Maximum Amp Demand| |Active Energy (kWh)|Maximum Watt Demand| |Reactive Power (VAr)|Maximum VA Demand| |Apparent Power (VA)|Neutral Current Measurement| |Reactive Energy (VArh)| **----- End of picture text -----**<br> ## **PROGRAMMABLE FUNCTIONS** All models feature the • AC or DC AUX following user-programmable • 1A or 5A CT functions: • Single or 3 phase system • Input voltage range 28-570V - Current Transformer Ratio - Current Transformer Ratio • RS485 address, 1-247 • Voltage Transformer Ratio • Security code access for • Baud Rate, Parity, Stops programming **==> picture [235 x 27] intentionally omitted <==** **----- Start of picture text -----**<br> |||||| |---|---|---|---|---| |STANDARD PRODUCT|OPTIONAL EXTRAS| |M850-MP1|P|RS|1|MV| **----- End of picture text -----**<br> **==> picture [115 x 184] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Suitable for any 1 or 3 phase| |system, AC aux 100-440V or| |DC aux 100-420V| |Input|28/330V L-N| |48/570V L-L| |5A| |Pulsed Output| |RS 485 Output| |1A input (instead of 5A)| |330mV Input| |(instead of 1A or 5A CT)| **----- End of picture text -----**<br> **Order example:** a standard product with RS 485 output is part number M850-MP1-RS ## **PLUG-IN OPTIONS** Both pulsed output (for Wh or VArh) and RS 485 output (Modbus protocol) are plug in options which can be supplied with the multifunction meter. If purchased separately please use ordering codes on right. **Pulsed Output RS 485 Output when ordered separately when ordered separately use part PULSE-M850 use part RS485-M850** ## **M850 MULTIFUNCTION METERS** **==> picture [105 x 71] intentionally omitted <==** ## **SPECIFICATIONS** ## **ACCURACY** Volts/Amps: 0.5% of reading Frequency: 0.1 Hz Active Power: 1% of reading Apparent Power:1% of reading Power Factor: 2% of range Energy: IEC 1036 Class 1 ## **INPUT** Rated Un: 28-330V LN, 48-570V L-L Overload: 800V continuous Burden: 0.5VA per phase Rated In: 0.5-6A Overload: 10 In for 1 sec Burden: 0.5VA per phase Auxiliary: 100-440V AC / 100-420V DC Frequency: 45/65Hz **DISPLAY** Digits: 3 lines 9999 Size: 14.2mm 7 segment Brightness: user adjustable **OUTPUT RELAY (Wh or VArh)** Pulse output: SPST-NO (10 watt, 300VDC, 500mA) Pulse duration: programmable from 40msec-200msec ## **INSULATION** 3kV RMS 50Hz for 1 minute between case, input and aux. Test Voltage: 1kV between case, input, aux, relay output & RS485 output. EMC 5kV transient complies with IEC801/ EN55020 HF Impulse test: Surge withstand: IEC801/EN55020 Ansi C37.90A Interference: EHF 2.5kV 1Mhz complying to IEC255-4 Protection class II: Complying to IEC348 / BS4753 / DIN57411 / VDE ## **STANDARDS** General: EMC: Safety: IEC688, BSEN60688, BS4889, IEC359 BSEN61000-6-3:2007, BSEN61000-6-4:2007, IEC1010, BSEN601010 ## **ENVIRONMENT** Working temp: 0-60ºC Storage temp: -40 to +85ºC Relative humidity: 0-95% non condensing Shock: 30G in 2 planes ## **MATERIAL** Black polycarbonate case to UL94V0 Weight: 0.35kg ## **CONNECTION DIAGRAM** ||L1<br>L2<br>L3<br>N<br>L<br>K<br>L3<br>l<br>k<br>L<br>K<br>L2<br>l<br>k<br>L<br>K<br>L1<br>l<br>k<br>L1<br>L2<br>L3<br>N<br>AUX UH<br>L+<br>N-|L1<br>L2<br>L3<br>N<br>L<br>K<br>L3<br>l<br>k<br>L<br>K<br>L2<br>l<br>k<br>L<br>K<br>L1<br>l<br>k<br>L1<br>L2<br>L3<br>N<br>AUX UH<br>L+<br>N-|L1<br>L2<br>L3<br>N<br>L<br>K<br>L3<br>l<br>k<br>L<br>K<br>L2<br>l<br>k<br>L<br>K<br>L1<br>l<br>k<br>L1<br>L2<br>L3<br>N<br>AUX UH<br>L+<br>N-|L1<br>L2<br>L3<br>N<br>L<br>K<br>L3<br>l<br>k<br>L<br>K<br>L2<br>l<br>k<br>L<br>K<br>L1<br>l<br>k<br>L1<br>L2<br>L3<br>N<br>AUX UH<br>L+<br>N-|L1<br>L2<br>L3<br>N<br>L<br>K<br>L3<br>l<br>k<br>L<br>K<br>L2<br>l<br>k<br>L<br>K<br>L1<br>l<br>k<br>L1<br>L2<br>L3<br>N<br>AUX UH<br>L+<br>N-|L1<br>L2<br>L3<br>N<br>L<br>K<br>L3<br>l<br>k<br>L<br>K<br>L2<br>l<br>k<br>L<br>K<br>L1<br>l<br>k<br>L1<br>L2<br>L3<br>N<br>AUX UH<br>L+<br>N-|L1<br>L2<br>L3<br>N<br>L<br>K<br>L3<br>l<br>k<br>L<br>K<br>L2<br>l<br>k<br>L<br>K<br>L1<br>l<br>k<br>L1<br>L2<br>L3<br>N<br>AUX UH<br>L+<br>N-|L1<br>L2<br>L3<br>N<br>L<br>K<br>L3<br>l<br>k<br>L<br>K<br>L2<br>l<br>k<br>L<br>K<br>L1<br>l<br>k<br>L1<br>L2<br>L3<br>N<br>AUX UH<br>L+<br>N-|L1<br>L2<br>L3<br>N<br>L<br>K<br>L3<br>l<br>k<br>L<br>K<br>L2<br>l<br>k<br>L<br>K<br>L1<br>l<br>k<br>L1<br>L2<br>L3<br>N<br>AUX UH<br>L+<br>N-|L1<br>L2<br>L3<br>N<br>L<br>K<br>L3<br>l<br>k<br>L<br>K<br>L2<br>l<br>k<br>L<br>K<br>L1<br>l<br>k<br>L1<br>L2<br>L3<br>N<br>AUX UH<br>L+<br>N-|**VOLTAGE**<br>**CURRENT**<br>**L1**<br>**L2**<br>**L3**<br>**N**<br>**L1**<br>**L2**<br>**L3**<br>1ph<br><br>**-**<br>**-**<br><br><br>**-**<br>**-**<br>1ph 3W<br><br><br>**-**<br><br><br><br>**-**<br>3ph 3W<br><br><br><br>**-**<br><br>**-**<br><br>3ph 4W<br><br><br><br><br><br><br><br>3ph 3W BAL<br><br><br><br>**-**<br><br>**-**<br>**-**<br>3ph 4W BAL<br><br>**-**<br>**-**<br><br><br>**-**<br>**-**<br>Unused Voltage terminals are internally connected|**CURRENT**<br>**L1**<br>**L2**<br>**L3**| |---|---|---|---|---|---|---|---|---|---|---|---|---| ||L3<br>l<br>k<br>L2<br>l<br>k<br>L1<br>l<br>k<br>L1<br>L2<br>L3<br>N<br>AUX UH<br>L+<br>N-|||||||||||| |||||||||||||<br>**-**<br>**-**| |||||||||||||<br><br>**-**| |||||L3<br>l<br>k|L2<br>l<br>k<br>|||L1<br>l<br>k||||| |||||||||||||<br>**-**<br>| |||||||||||||| |||||||||||||<br><br>| ||||||||L<br>K|||||<br> <br> <br><br>**-**<br>**-**| ||||||L<br>K|||||||<br><br>**-**<br>**-**| ||||L<br>K|||||||||| ## **DIMENSIONS (mm)** **==> picture [407 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> with plug in<br>option fitted<br>96 19 82<br>92 (+0.8)<br>96 92 (+0.8)<br>61 Panel cut out<br>**----- End of picture text -----**<br> Our policy is one of continuous development and therefore specifications may change without notice. ## **HOWARD BUTLER LTD** CROWN WORKS, LINCOLN ROAD WALSALL WS1 2EB ENGLAND Tel: 01922 640003 Fax: 01922 723626 International Tel: +44 1922 640003 E-mail: sales@hobut.co.uk Web: www.hobut.co.uk
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →