M5842-000005-10KPG
PRESSURE SENSOR, ANALOGUE, 10000PSI, 30V
- Manufacturer: TE CONNECTIVITY
- Product type: Pressure Transducers
- Port Style: 1/4" - 18 NPT
- Product Range: M5800 Series
- Sensor Output: Voltage
- Supply Current: 30mA
- Voltage Rating: 30V
- Operating Pressure Max: 10000psi
- Pressure Measurement Type: Gauge
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 173.72 € |
| Current stock | 10+ |
| Lead time | 30 days |
## M5800 Pressure Transducer with Rotatable Display ## SPECIFICATIONS **==> picture [49 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> VRoHS<br>**----- End of picture text -----**<br> - **Wide Temperature Range** - **Compact** - **Variety of Pressure Ports and customized Electrical Configurations** - **Optional Stainless Steel Snubber** - **CE Compliant and Weatherproof** - **Gage, Compound** - **Continuous pressure display with zero setting** Difficulty reading pressure measurements in awkward spaces throughout your process can compromise your operational efficiency. TE’s M5800 digital display transducer offers visualized pressure value readings for demanding , harsh applications. The 310° rotatable display enables easy viewing and on-demand adjustment. Offering precise measurements at a superior value, this sensor can be easily configured based on your specific requirements including pressure range, pressure fitting, analog output, and electrical connection. Its display zero tare feature enables the local user to precisely set the display to zero and offers a more precise pressure measurement and true control of your processes. SENSOR SOLUTIONS ///M5800 05/2017 Page 1 M5800 Pressure Transducer With Rotatable Display ## FEATURES - CE Compliance - Reverse Polarity Protection on Input - Short Circuit Protection on Output - ±0.25% Accuracy within compensation temperature - ±1.0% Total Error Band within compensation temperature - ±0.25% of Rdg ±1 count for display accuracy - Compact Outline - -40°C to +85°C Operating Temperature - IP67 Weatherproof - Continuous display rotation ## APPLICATIONS - Food & Beverage systems - Pharmaceutical & Medical systems - Pumps and Compressors - Hydraulic/Pneumatic Systems ## STANDARD RANGES |**Range (psi)**|**Range (Bar)**|**Gage**|**Compound**| |---|---|---|---| |0 to 050|0 to 3.5||| |0 to 100|0 to 007||| ||0 to 010||| |0 to 200|||| |0 to 300|0 to 020||| |0 to 500|0 to 035||| |0 to 01k|0 to 070||| |0 to 03k|0 to 200||| |0 to 05k|0 to 350||| |0 to 07k|0 to 500||| |0 to 10k|0 to 700||| |0 to 15k|0 to 01k||| Intermediate pressure ranges available upon request SENSOR SOLUTIONS ///M5800 05/2017 Page 2 M5800 Pressure Transducer With Rotatable Display ## PERFORMANCE SPECIFICATIONS ## **Ambient Temperature: 25°C (unless otherwise specified)** |**PARAMETERS**|**MIN**|**TYP**|**MAX**|**UNITS**|**NOTES**| |---|---|---|---|---|---| |Accuracy<br>(combined non linearity, hysteresis, and repeatability)|-0.25||0.25|%F.S.|BFSL| |Isolation, Body to any Lead|100|||MΩ|@500VDC| |Dielectric Strength|||2|mA|@500VAC, 1min| |Pressure Cycles|1.00E+6|||0~FS Cycles|| |Proof Pressure|2X|||Rated|| |Burst Pressure|5X||20k psi|Rated|Whichever is less| |Long Term Stability (1 year)|-0.25||0.25|%F.S.|| |Total Error Band (17-4PH)|-1.0||1.0|%F.S.|Within CT| |Total Error Band (316L, ≤3k psi)|-1.5||1.5|%F.S.|Within CT| |Total Error Band (316L, >3k psi)|-2.0||2.0|%F.S.|Within CT| |Compensated Temperature (CT)|-20||+85|°C|| |Operating Temperature|-40||+85|°C|| |Storage Temperature|-40||+90|°C|| |Load Resistance (RL)||RL> 100k||Ω|Voltage Output| |Load Resistance (RL)|< (Supply Voltage -12V) / 0.02A|||Ω|Current Output| |Current Consumption|||30|mA|Voltage Output| |Rise Time (10% to 90%)|<2ms (Voltage Output); <3ms (Current Output); Without Snubber||||| |Wetted Material|17-4PH or 316L Stainless Steel Port, 316L Stainless||||Steel Snubber| |Weather Proof|IP67||||| |Bandwidth|DC to 1KHz (Typical)||||| |Shock|50g, 11msec Half Sine Shock per MIL-STD-202G, Method 213B, Condition A||||| |Vibration|±20g, MIL-STD-810C, Procedure 514.2, Fig 514.2-2, Curve L||||| For custom configurations, consult factory. ## **Notes** Compensated Temperature: The temperature range over which the product will produce an output proportional to pressure within the specified performance limits. Operating Temperature: The temperature range over which the product will produce an output proportional to pressure but may not remain within the specified performance limits. Storage Temperature: The temperature range over which the product can be stored safely in occasions without pressure applied or power input and remains rated performance. Beyond this temperature range may cause permanent damage to the product. All configurations are built with supply voltage reverse and output short-circuit protections. ## **CE Compliance** EN 55022 Emissions Class A & B IEC 61000-4-2 Electrostatic Discharge Immunity (4kV contact/8kV air) IEC 61000-4-3 Radiated, Radio-Frequency Electromagnetic Field Immunity (10V/m, 80M-1GHz) IEC 61000-4-4 Electrical Fast Transient Immunity (1kV) IEC 61000-4-5 Surge Immunity (V+ to V-: ±1KV/42Ω; L to Case: ±1KV/42Ω; V- to V0: ±1KV/42Ω) IEC 61000-4-6 Immunity to Conducted Disturbances Induced by Radio Frequency Fields (150K~80MHz, 3V level) For all CE compliance tests, max allowed output deviation ±1.5 %F.S. SENSOR SOLUTIONS ///M5800 05/2017 Page 3 M5800 Pressure Transducer With Rotatable Display ## **Display Specification** ||Within range: -XXX to XXXX| |---|---| |Digits Display|Overload(>110%FS): OP| |Type|7 Segment Blue LED| |Polarity|Automatic (-) Display| |Display Accuracy (excluding transducer output)|+/-0.25% of Rdg +/- 1 Count| |Character Size|0.24” height| |Viewing Direction|Rotatable| |Zero button|Tare affecting only display| |**Display Digital Resolution**|**Display Digital Resolution**||||| |---|---|---|---|---|---| |**PRESSURE UNIT**|**PRESSURE RANGE**|**PRESSURE RANGE**<br>**DISPLAY DIGIT**|**DISPLAY DIGIT**<br>**DECIMAL PLACE**|**DECIMAL PLACE**<br>**NEGATIVE PRESSURE**|**NEGATIVE PRESSURE**<br>**EXAMPLE**| |PSI|>050P & <100P|3|1|“-” precedes number|01.0~99.9, -13.7,<br>(100.0 indicate 100PSI)| |PSI|>100P & <01KP|3|NA|“-” precedes number|101~999, -013| |PSI|>01KP & <10KP|4|NA|“-” precedes number|1000~9999, -013| |KPSI|>10KP & <15KP|4|2|NA|10.00~15.00| |BAR|>3.5B & <01KB|4|1|“-” precedes number|003.5~700.0, -000.1,| ||||||(1000 indicate 01KB)| ## DIMENSIONS [mm] **==> picture [107 x 14] intentionally omitted <==** **----- Start of picture text -----**<br> CABLE, 22 AWG,<br>BELDEN 8723 OR EQUIVALENT<br>**----- End of picture text -----**<br> |**CODE**|**DIM C**| |---|---| |**1**|CABLE 2 FT| |**E**|CABLE 3 FT| |**2**|CABLE 4 FT| |**3**|CABLE 10 FT| |**M**|CABLE 1 M| |**N**|CABLE 2 M| |**P**|CABLE 5 M| |**R**|CABLE 10 M| |**X**|Cable special Length with<br>customized connector (must fit<br>22 AWG size cable)| SENSOR SOLUTIONS ///M5800 05/2017 Page 4 M5800 Pressure Transducer With Rotatable Display |**CODE**|**PORT**|**DIM B**|**DIM A REF.**|**Recommended**<br>**Torque (N.m)**| |---|---|---|---|---| |**2**|1/4-19 BSPP|0.472|0.366|30~35| |||[11.94]|[9.3]|| |**3**|G3/8 JIS B2351|0.540|0.366|35~40| |||[13.72]|[9.3]|| |**4**|7/16-20UNF MALE SAE J1926-<br>2 STRAIGHT THREAD O-<br>RINGBUNA-N90SH-904|0.433|0.366|18~20| |||[11.0]|[9.3]|| |**5**|1/4-18 NPT|0.600|0.366|2~3 TFFT| |||[15.24]|[9.3]|| |**6**|1/8-27 NPT|0.390|0.366|2~3 TFFT| |||[9.91]||| |**B**|G1/4 JIS B2351|0.472|0.366|30~35| |||[11.94]|[9.3]|| |**E**|1/4-19 BSPT|0.500|0.366|2~3 TFFT| |||[12.7]|[9.3]|| |**F**|1/4-19 BSPP FEMALE|0.621|0.366|30~35| ||(without snubber)|[15.77]|[9.3]|| |**P**|7/16-20UNF FEMALE SAE<br>J513 STRAIGHT THREAD<br>WITH INTEGRAL VALVE<br>DEPRESSOR|0.430|0.444|15~16| |||[10.92]|[11.28]|| |**N**|7/16-20UNF FEMALE SAE<br>J513 STRAIGHT THREAD|0.430|0.444|15~16| |||[10.92]|[11.28]|| |**Q**|M10 x 1.0 mm ISO 6149-2|0.374|0.366|15~16| |||[9.5]|[9.3]|| |**S**|M12 x 1.5 mm ISO 6149-2|0.433|0.366|25~30| |||[11.0]|[9.3]|| |**U**|G/14 DIN 3852 FORM E<br>GASKET DIN3869-14 NBR|0.472|0.445|30~35| |||[11.94]|[11.3]|| |**W**|M20 x 1.5 mm ISO 6149-2|0.551|0.366|40~45| |||[14.0]|[9.3]|| |**G**|M14 x 1.5 mm ISO 6149-2|0.433|0.366|25~30| |||[11.0]|[9.3]|| ## WIRING ||||| |---|---|---|---| |**Current Output Wiring**|||| |**+SUPPLY**|**-SUPPLY**|**Ground**|| |RED|BLK|Drain wire|| ||||| |**Voltage Output Wiring**|||| |**+SUPPLY**|**+OUTPUT**|**COMMON**|**Ground**| |RED|WHT|BLK|Drain wire| SENSOR SOLUTIONS ///M5800 05/2017 Page 5 M5800 Pressure Transducer With Rotatable Display ## OUTPUTS |CODE|OUTPUT SIGNAL|SUPPLY VOLTAGE| |---|---|---| |4|1 TO 5 V|8~30 V| |5|4 TO 20 mA|12~30 V| |6|0 TO 5 V|8~30 V| |7|0 TO 10 V|12~30 V| |8|1 TO 6 V|8~30 V| |9|0.5 TO 4.5 V|8~30 V| ## ORDERING INFORMATION |M58|3|1|-|0|0|00|0|5|-|100P|100P|G| |---|---|---|---|---|---|---|---|---|---|---|---|---| |**Model**|**Output**<br>**Signal**|**Connection Type**|**-**|**Port**<br>**Material**|**Snubber**|**00**|**Label**|**Pressure**<br>**Port**|**-**|**Pressure**<br>**Range **||**Pressure**<br>**Type **| |**M58**|**4**= 1 – 5V<br>**5**= 4 – 20mA<br>**6**= 0 – 5V<br>**7**= 0 – 10V<br>**8**= 1 – 6V<br>**9**= 0.5 – 4.5V|**1**= Cable 2 ft<br>**E**= Cable 3 ft<br>**2**= Cable 4 ft<br>**3**= Cable 10 ft<br>**M**= Cable 1 m<br>**N**= Cable 2 m<br>**P**= Cable 5 m<br>**R**= Cable 10 m<br>**X**= special cable length<br>with customized<br>connector|-|**0**= 17-4PH<br>**1**= 316L SS|**0**= No<br>Snubber<br>**1**= Oxygen<br>Clean B40.1<br>Level IV<br>**2**= With<br>Snubber|**00**|**0**= Adhesive<br>Label<br>**1**= Laser<br>Marking|**2**= 1/4-19 BSPP<br>**3**= G3/8 JIS B2351<br>**4**= 7/16-20UNF Male<br>SAE J1926-2 Straight<br>Thread O-Ring BUNA-<br>N 90SH-904<br>**5**= 1/4-18 NPT<br>**6**= 1/8-27NPT<br>**B**= G1/4 JIS B2351<br>**E**= 1/4-19 BSPT<br>**F**= 1/4-19 BSPP<br>Female<br>**P**= 7/16-20UNF<br>Female SAE J513<br>Straight Thread with<br>Integral Valve<br>Depressor<br>**N**= 7/16-20UNF<br>FEMALE SAE J513<br>Straight Thread<br>**Q**= M10 x 1.0 mm<br>ISO 6149-2<br>**S**= M12 x 1.5 mm<br>ISO 6149-2<br>**U**= G1/4 DIN 3852<br>Form E Gasket<br>DIN3869-14 NBR<br>**W**= M20 x 1.5 mm<br>ISO 6149-2<br>**G**= M14 x 1.5 mm<br>ISO 6149-2|-|**050P**<br>**100P**<br>**200P**<br>**300P**<br>**500P**<br>**01KP**<br>**03KP**<br>**05KP**<br>**07KP**<br>**10KP**<br>**15KP**|**3.5B**<br>**007B**<br>**010B**<br>**020B**<br>**035B**<br>**070B**<br>**200B**<br>**350B**<br>**500B**<br>**700B**<br>**01KB**|**G**= Gage<br>**C**= Compound| ## **Note** : Compound pressure range is -14.7 to xxxpsig or -1 to xxxbarg. (e.g. 200PC: -14.7 to 200psig, 020BC: -1 to 20barg) Refer to online installation instruction for recommended torque. For installation instructions, please find the document under “RELATED MATERIALS” at the M5800 product website of te.com SENSOR SOLUTIONS ///M5800 05/2017 Page 6 M5800 Pressure Transducer With Rotatable Display ## **NORTH AMERICA** Measurement Specialties, Inc., a TE Connectivity company Tel: 800-522-6752 (option 2) Email: customercare.frmt@te.com ## **EUROPE** MEAS France SAS, a TE Connectivity company Tel: 800-440-5100 Email: customercare.lcsb@te.com ## **ASIA** Measurement Specialties (China) Ltd., a TE Connectivity company Tel: 0400-820-6015 Email: customercare.shzn@te.com ## **te.com/sensorsolutions** Measurement Specialties, Inc., a TE Connectivity company. Measurement Specialties (MEAS), American Sensor Technologies (AST), TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. © 2016 TE Connectivity Ltd. family of companies All Rights Reserved. SENSOR SOLUTIONS ///M5800 05/2017 Page 7
Updated at February 9, 2023
TE Connectivity is a globally recognized engineering and manufacturing leader, specializing in highly reliable connectivity and sensing solutions. Renowned for innovation and durability, their components are engineered to perform in the most demanding environments, supporting critical advancements in industrial equipment, data communications, and automotive systems. Our extensive selection of TE Connectivity products is anchored by their industry-leading connector portfolio. We carry a comprehensive array of terminal blocks and accessories, including wire-to-board, pluggable, standard, and barrier configurations, alongside robust backplane connectors designed to ensure secure and efficient power and data transmission in complex circuit designs. Beyond physical connections, TE Connectivity is a premier manufacturer of precision sensors, antennas, and electromechanical switching components. Our inventory features a wide variety of RF antennas and highly accurate pressure, temperature, and force transducers. Additionally, we provide an expansive range of TE's dependable relays, encompassing automotive, power, and signal variants, alongside essential passive components like shielding gaskets and RF inductors to fully support your engineering requirements.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →