LZSA-500-3
AC-DC CONVERTER, ENCLOSED, 1 O/P, 504W, 21A, 24V
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC Enclosed Power Supplies
- Power Supply Applications:ITE; No. of Outputs:1Outputs; Output Power Max:504W; Output Voltage - Output 1:24V; Output Current - Output 1:21A; Output Vo 05M3602
- No. of Outputs: 1Outputs
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 1050.96 € |
| Current stock | 10+ |
| Lead time | 30 days |
LZSA Series ## 500-1500W Industrial Power supplies https://product.tdk.com/en/power/lzsa www.emea.lambda.tdk.com/lzsa The LZSA series offers a unique feature set not commonly found with standard off-the-shelf supplies. Compliance to the MIL-STD-810E standards for shock and vibration and board coating make the LZSA power supplies ideal for use in a variety of harsh environment applications. They also comply with the tough ring wave lightning surge test per IEEE C62.41. Features include remote on/off, remote sense, frequency synchronization and a wide operating temperature range of -40°C to +71°C. The series also has a wide adjustment range which can be programmed using an external voltage or resistance. |**Features**|**Benefits**| |---|---| |• Rugged Mechanical Design With Coating on PCBs|• High Reliability in Harsh Environments| |• Superior Thermal Design|• Long Life Even at 71°C Operation| |• Wide Range, Programmable Output Adjustment|• Reduces The Need For custom Outputs| |• Input Voltage Transient Protection|• Reduced System Filtering| |**Model Selector**|||||| |---|---|---|---|---|---| |||Nominal Output|Adjustment|Maximum|Maximum| |Part Number||Voltage|Range|Current|Power| |for Ordering|Model Number*|(V)|(V)|(A)|(W)| |LZSA-1000-2|LZS-A1000-2|12|10 - 15.75|84|1008| |LZSA-500-3|LZS-A500-3|24|18 - 29.4|21|504| |LZSA-1000-3|LZS-A1000-3|24|18 - 29.4|42|1008| |LZSA-1500-3-001|LZS-A1500-3-001|24|18 - 29.4|63|1512(3)| |LZSA-1500-4|LZS-A1500-4|48|36 - 56|31.5|1512(3)| * This part number is listed on the LZSA rating label and safety files LZSA Series 1 **==> picture [517 x 34] intentionally omitted <==** ## **Specification** |**Specifcation**|**Specifcation**|**Specifcation**|**Specifcation**|**Specifcation**| |---|---|---|---|---| |Model<br>LZSA500<br>LZSA1000<br>LZSA1500||||| |**Input**||||| |Input Voltage Range (Operating)|Vac|85 - 265<br>||| |Nominal Input Voltage Range|Vac|100-240 (Note: Safety certifed for 90-264Vac)<br>||| |Input Frequency(2)|Hz|47-440 (Note: Safety certifed for 47-63Hz only)<br>||| |DC Input Voltage range(1)|Vdc|100-380V (Note: Safety certifed for AC input only)||| |Input Current Maximum (100Vac)|A|7.3|15|18| |Inrush Current (110 / 220Vac)|A|25 / 45|30 / 40|| |Leakage Current (AC line to chassis ground)|uA|<500 at 265Vac, 60Hz||<1500 at 265 Vac, 60Hz| |Power Factor|-|EN61000-3-2 Class A||| |Harmonics|-|EN61000-3-2 Compliant||| |Hold Up Time at 110Vac Input<br>|ms|20 hold up, 20 ride through||| |Effciency (Typical)|-|84||| |Emissions|-|EN55032/EN55011 Class B, EN61000-3-3, MIL STD 461/462D, CE102||| |Immunity|-|See Immunity Table||| |Line Dip<br>|-|SEMI F47 Compliant(4)||| |Safety Certifcations and Markings|-|IEC/EN/UL/CSA62368-1, 60950-1, UL508, CE Mark, UKCA Mark||| ## **Immunity** |**Immunity**|**Immunity**|**Immunity**|**Immunity**|**Immunity**| |---|---|---|---|---| |Test<br>Standard<br>Test Level<br>Criteria||||Notes| |ESD|IEC 61000-4-2|±8kV air discharge,<br>±6kV contact discharge|B|See test report<br>on website| |Radiated Susceptibility|IEC 61000-4-3|10V/m, 80 - 1000MHz<br>(80% AM at 1kHz)|A|| |Electrical Fast Transient Burst|IEC 61000-4-4|AC line pulses of ±2 kV;<br>I/O line pulses of ±2kV>3m|A|| |Surge|IEC 61000-4-5|±2kV common mode,<br>±1kV differential mode|A|| |Conducted Susceptibility|IEC 61000-4-6|10Vrms, 150kHz - 80 MHz<br>1kHz 80% AM|A|| |Magnetic felds|IEC 61000-4-8|30Arms/m @ 50Hz|A|| |Voltage Dips and Input Interruptions|IEC 61000-4-11|Voltage Dips of 30%, 60% and<br>100%; Interruptions of >95%|A & B|| |Ring Wave|IEEE C62.41|6kV/30 ohms|A|| |SEMI F47 Line Dip|SEMI F47|||See installation manual on website| LZSA Series 2 **==> picture [516 x 34] intentionally omitted <==** |**Specifcation**|**Specifcation**|**Specifcation**|**Specifcation**|**Specifcation**| |---|---|---|---|---| |Model<br>LZSA500<br>LZSA1000<br>LZSA1500||||| |**Output**||||| |Line Regulation|%|0.10||| |Load Regulation|%|0.10||| |Transient Response<br>|-|±1% deviation, recovering to ±0.2% in <1.25ms (25% load change)||| |Temperature Coeffcient|ppm/°C|<br>100||| |Ripple & Noise (pk-pk) (max.)|mV|75|75|24V: 75, 48V: 150| |Minimum Load|A|None||| |Overcurrent Protection|%|110-130||| |Overvoltage Protection|-|User adjustable from front panel||| |Overtemperature Protection|-|Internal thermostat. Cycle AC to reset.||| |Remote Sense|-|Compensates for a total of 1V cable drop||| |Remote On/Off|-|TTL compatible, active high||| |Remote Adjust|-|Using front panel potentiometer, Resistance (1k/V), or Voltage (1V/V)||| |Input Power Good|-|Opto coupled, conducts up to 1mA @ <0.4V when active||| |DC Good|-|Opto coupled, conducts up to 1mA @ <0.4V when active||| |Inverter good|-|Opto coupled, conducts up to 1mA @ <0.4V when active||| |Synchronization (Sync)|-|Auxiliary signal at approximately 200kHz used for synchronizing with other equipment.||| |Indicators|-|Green LED indicates output good; red LED indicates overvoltage, overtemperature, or overcurrent||| |Parallel Operation|-|Single wire current share||| |Series Operation|-|See Installation Manual||| |**Environmental**||||| |Operating Temperature|°C|-40 to +71, derate linearly to 60% load from 60 - 71°<br>(A 20 minute warm up period needed for <30°)||| |Storage Temperature|°C|-40 to +85||| |Humidity (non condensing)|%RH|10 - 90||| |Cooling|-|Variable speed, ball bearing fan||| |Altitude|m|3,000 operating, 12,000 non-operating||| |Withstand Voltage|VDC|Input to Ground 2,121, Input to Output 4,242, Output to Ground 500||| |Vibration|-|MIL-STD-810E, Method 514.4, Category 1, 9||| |Shock|-|MIL-STD-810E, Method 516.4, Procedure I, II, IV, VI||| |**Other**||||| |Weight (Typ)|lbs / kg|<br>6.6 / 2.95|8.1 / 3.7|| |Size (WxHxD) (excluding bus bars)|mm|108 x 121 x 260|143 x 121 x 267|| |Size (WxHxD) (excluding bus bars)|Inches|<br>4.25 x 4.75 x 10.25|5.62 x 4.75 x 10.5|| |MTBF - Bellcore|Hours|132,958|99,039|99,039| |Warranty|Years|5||| Notes (1) Startup >110VDC (2) Reduced power factor above 63Hz (3) 1512W @ 180-265Vac, 1200W @ 120Vac, 1104W @ 100Vac, 1008W @ 85Vac (4) See website for detailed specifications, test methods and installation manual ## **Derating Charts** **==> picture [510 x 137] intentionally omitted <==** LZSA Series 3 ## **LZSA500 Outline Drawing** ## **LZSA1000-3 & LZSA1500-4 Outline Drawing** LZSA Series 4 ## **LZSA1000-2 & LZSA1500-3-001 Outline Drawing** LZSA Series 5 ## **TDK-Lambda France SAS** Tel: +33 1 60 12 71 65 tlf.fr-powersolutions@tdk.com www.emea.lambda.tdk.com/fr ## **Italy Sales Office** Tel +39 02 61 29 38 63 tlf.it-powersolutions@tdk.com www.emea.lambda.tdk.com/it ## **Netherlands** tlf.nl-powersolutions@tdk.com www.emea.lambda.tdk.com/nl ## **TDK-Lambda Europe GmbH** Tel: +49 7841 666 0 tlg.powersolutions@tdk.com www.emea.lambda.tdk.com/de **Austria Sales Office** Tel: +43 2256 655 84 tlg.at-powersolutions@tdk.com www.emea.lambda.tdk.com/at ## **Switzerland Sales Office** Tel: +41 44 850 53 53 tlg.ch-powersolutions@tdk.com www.emea.lambda.tdk.com/ch ## **TDK-Lambda Americas** Tel: +1 800-LAMBDA-4 or 1-800-526-2324 tla.powersolutions@tdk.com www.us.lambda.tdk.com ## **TDK Electronics do Brasil Ltda** Tel: +55 11 3289-9599 sales.br@tdk-electronics.tdk.com www.tdk-electronics.tdk.com/en ## **TDK-Lambda Corporation** Tel: +81-3-6778-1113 www.jp.lambda.tdk.com ## **TDK-Lambda (China) Electronics Co. Ltd.** Tel: +86 21 6485-0777 tlc.powersolutions@tdk.com www.lambda.tdk.com.cn ## **TDK-Lambda Singapore Pte Ltd.** Tel: +65 6251 7211 tls.marketing@tdk.com www.sg.lambda.tdk.com ## **TDK India Private Limited, Power Supply Division** Tel: +91 80 4039-0660 mathew.philip@tdk.com www.sg.lambda.tdk.com ## **TDK-Lambda Europe GmbH** Tel: Tel. +45 3222 8086 tlg.dk-powersolutions@tdk.com www.emea.lambda.tdk.com/dk ## **TDK-Lambda UK Ltd.** Tel: +44 (0) 12 71 85 66 66 tlu.powersolutions@tdk.com www.emea.lambda.tdk.com/uk ## **TDK-Lambda Ltd.** Tel: +9 723 902 4333 tli.powersolutions@tdk.com www.emea.lambda.tdk.com/il-en For Additional Information, please visit ~~a~~ https://product.tdk.com/en/power/ LZSA 260822 April 20, 2026 V4 LZSA Series 6
Updated at June 4, 2026
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →