Image not available
Illustrative purposes only
LY3F-AC24
POWER - GENERAL PURPOSE
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: OMRON / PARTNER STOCK
- Product type: Power Relays
- SVHC: No SVHC (25-Jun-2025)
| Delivery and price | |
|---|---|
| Units per pack | 15 |
| Price | 19.98 € |
| Current stock | 100+ |
| Lead time | 30 days |
**Bi-power Relays LY** CSM_LY_OEE_DS_E_ 2 _ 5 ## **Power-switching Compact General-purpose Relays** - Wiring work can be shortened by as much as 60%* compared to conventional screw terminal sockets by combining with push-in plus terminal sockets (PYF- @ - PU) that feature light insertion force and strong pullout strength to achieve less wiring work. - The standard models include models that are compliant with the UL, CSA, and SEV safety standards and with the Electrical Appliances and Material Safety Act. - Equipped with an arc barrier for arc interruption. - Withstand voltages up to 2,000 V. - New built-in diode and built-in CR circuit models have joined the series. - The lineup also includes models that are compliant with the LR and VDE safety standards. Refer to the standards certifications and compliance section of your OMRON website for the latest information on certified models. - When both push-in plus terminals and screw terminal sockets are combined with plug-in terminal types (according to actual OMRON measurements as of November 2015) **Refer to the** _**Common Relay Precautions**_ **.** ## **Model Number Structure** |**Structure**<br>**Classification**<br>**Number**<br>**of poles**<br>~~Pf~~|**Structure**<br>**Classification**<br>**Number**<br>**of poles**<br>~~Pf~~|**Structure**<br>**Classification**<br>**Number**<br>**of poles**<br>~~Pf~~|**Relays with Plug-in Terminals**<br>**With operation indicators**<br>~~Pf~~|**Relays with Plug-in Terminals**<br>**With operation indicators**<br>~~Pf~~|**Relays with PCB Terminals**<br>~~ais~~|**Case-surface mounting**<br>~~ais~~| |---|---|---|---|---|---|---| |||||**With operation indicators**<br>~~Pf~~||| |**Standard models**<br>**Compliance with**<br>**Electrical Appliances**<br>**and Material Safety Act**<br>~~Pf~~|**1**<br>~~Pf~~<br>~~a~~||***LY1**<br>~~Pf~~<br>|LY1N**<br>~~Pf~~<br>|***LY1-0**<br>~~ais~~|***LY1F**<br>~~ais~~| ||**2**<br>**Bifur-**<br>**cated**<br>~~ee~~||***LY2**<br>~~ee~~|LY2N**<br>~~ee~~|***LY2-0**|***LY2F**| |||**Bifur-**<br>**cated**<br>~~ee~~|LY2Z**<br>~~ee~~|LY2ZN**<br>~~ee~~|LY2Z-0**|LY2ZF**| ||**3**<br>~~ee~~<br>~~a~~||---<br>~~ee~~<br>~~a~~|---<br>~~ee~~<br>~~a~~|***LY3-0**<br>~~a~~|---<br>~~a~~| ||**4**<br>~~a~~||***LY4**<br>~~a~~|LY4N**<br>~~a~~|***LY4-0**<br>~~a~~|***LY4F**<br>~~a~~| |**Models with diode for**<br>**coil surge absorption**<br>**(DC coil specification**<br>**only)**<br>~~a~~<br>ge|**1**<br>~~a~~<br>~~>~~||LY1-D**<br>~~a~~<br>~~pT~~|LY1N-D2**<br>~~a~~<br>~~pT.~~|---<br>~~a~~|---<br>~~a~~| ||**2**<br>**Bifur-**<br>**cated**<br>~~a~~<br>~~>~~<br>~~ee~~||LY2-D**<br>~~a~~<br>~~pT~~|LY2N-D2**<br>~~a~~<br>~~pT.~~|---<br>~~a~~|---<br>~~a~~| |||**Bifur-**<br>**cated**<br>~~a~~<br>~~>~~<br>~~ee~~|LY2Z-D**<br>~~a~~<br>~~pT~~<br>~~a~~|LY2ZN-D2**<br>~~a~~<br>~~pT.~~|---<br>~~a~~|---<br>~~a~~| ||**4**<br>~~a~~<br>~~>~~<br>~~ee~~<br>~~ee~~||LY4-D**<br>~~a~~<br>~~pT~~<br>~~a~~<br>~~ee~~|LY4N-D2**<br>~~a~~<br>~~pT .~~<br>~~ee~~|---<br>~~a~~|---<br>~~a~~| |**Models with CR circuits**<br>**for coil surge**<br>**absorption**<br>**(AC coil specification**<br>**only)**<br>~~ee~~|**1**<br>~~ee ~~<br>~~ee~~||**---**<br> ~~a~~<br>~~ee~~|**---**<br>~~ee~~||| ||**2**<br>**Bifur-**<br>**cated**<br>~~ee~~||LY2-CR**<br>~~ee~~<br>~~a~~|LY2N-CR**<br>~~ee~~||| |||**Bifur-**<br>**cated**|LY2Z-CR**<br>~~a~~|LY2ZN-CR**||| - **Note: 1.** Cells with a diagonal line cannot be manufactured. Ask your OMRON representative for details on manufacturing products for cells containing “---” in the above table. **2.** If #187 tab terminals are required, use the LY1F-T2 or LY2F-T2 (single-pole or double-pole models only). **3.** Refer to page 20 for information on plug-in terminal and socket combinations. **4.** Items with an asterisk (*) in the table are certified for UL, CSA, and SEV. This is indicated with a certification mark on the products. **5.** Items with two asterisks (**) in the table are certified for UL and CSA. This is indicated with a certification mark on the products. **6.** All models in the table are certified for IEC (TÜV). **7.** The models with plug-in terminals (single-pole, double-pole, and 4-pole) were combined with the PTF-E for the EC Declaration of Conformity. These products display the CE Marking. **1** **LY** **When your order, specify the rated voltage.** ## **Ordering Information** ## **Relays** ## **Models with Plug-in Terminals** |**Number of poles**|**Number of poles**||**1 pole**||**2 poles**||**4 poles**| |---|---|---|---|---|---|---|---| |**Classification**||**Model**|**Rated voltage (V)**|**Model**|**Rated voltage (V)**|**Model**|**Rated voltage (V)**| |**Models with**<br>**single**<br>**contacts**|**Standard models**|**LY1**|12, 24, 100/110,<br>110/120,<br>or 200/220 VAC|**LY2**|12, 24, 100/110,110/<br>120, 200/220,<br>or220/240 VAC|**LY4**|12, 24, 100/110, or<br>200/220 VAC| ||||12, 24, 48,<br>or 100/110 VDC||12, 24, 48,<br>or 100/110 VDC||12, 24, 48,<br>or 100/110 VDC| ||<br>**Models with built-in**<br>**operation indicators**|**LY1N**|12, 24, 100/110,<br>110/120,<br>or 200/220 VAC|**LY2N**|12, 24, 100/110,110/<br>120, 200/220,<br>or 220/240 VAC|**LY4N**|12, 24, 100/110, or<br>200/220 VAC| ||||12, 24,<br>or 100/110 VDC||12, 24, 48,<br>or 100/110 VDC||12, 24, 48,<br>or 100/110 VDC| ||**Models with built-in**<br>**diodes**|**LY1-D**|12, 24, 48,<br>or 100/110 VDC|**LY2-D**|12, 24, 48,<br>or 100/110 VDC|**LY4-D**|12, 24, 48,<br>or 100/110 VDC| ||**Models with built-in**<br>**diodes and**<br>**operation indicators**|**LY1N-**<br>**D2**|12, 24, or 48 VDC|**LY2N-D2**|12, 24, 48,<br>or 100/110 VDC|**LY4N-**<br>**D2**|12, 24, 48,<br>or 100/110 VDC| ||**Models with built-in**<br>**CR circuits**|**---**|**---**|**LY2-CR**|100/110, 110/120,<br>200/220, or 220/240<br>VAC|---|---| ||**Models with built-in**<br>**CR circuits and**<br>**operation indicators**|**---**|**---**|**LY2N-CR**|100/110, 110/120,<br>200/220, or 220/240<br>VAC|---|---| |**Bifurcated**<br>**contacts**|**Standard models**|**---**|**---**|**LY2Z**|100/110 or200/220<br>VAC|---|---| |||**---**|**---**||12, 24, 48, or 100/<br>110 VDC|---|---| ||**Models with built-in**<br>**operation indicators**|**---**|**---**|**LY2ZN**|**1**<br>00/110, 110/120,<br>200/220,<br>or 220/240 VAC|---|---| |||**---**|**---**||12 or 24 VDC|---|---| ||**Models with built-in**<br>**diodes**|**---**|**---**|**LY2Z-D**|12, 24, or 48 VDC|---|---| ||**Models with built-in**<br>**diodes and**<br>**operation indicators**<br>|**---**|**---**|**LY2ZN-**<br>**D2**|12, 24, or 100/110<br>VDC|---|---| ||**Models with built-in**<br>**CR circuits**|**---**|**---**|**LY2Z-CR**|100/110 VAC|---|---| ||**Models with built-in**<br>**CR circuits and**<br>**operation indicators**|**---**|**---**|**LY2ZN-**<br>**CR**|100, 110, 110/1 20,<br>or 200/220 VAC|---|---| ## **Relays with PCB Terminals** |**Number of poles**||**1 pole**||**2 poles**||**3 poles**||**4 poles**| |---|---|---|---|---|---|---|---|---| |**Classification**|**Model**|**Rated voltage (V)**|**Model**|**Rated voltage (V)**|**Model**|**Rated voltage (V)**|**Model**|**Rated voltage (V)**| |**Models with single**<br>**contacts**|**LY1-0**|24,100/110,<br>110/120, or 200/220<br>VAC|**LY2-0**|12, 24,<br>100/110, 110/120, 200/<br>220, or 220/240 VAC|**LY3-0**|24, 100/110,<br>or 200/220 VAC|**LY4-0**|24, 100/110, or 200/<br>220 VAC| |||12 or 24 VDC||12, 24, 48<br>or 100/110 VDC||12, 24, 48, or<br>100/110 VDC||12, 24, 48, or<br>100/110 VDC| |**Bifurcated contacts**|---|---|**LY2Z-0**|100/110 VAC|---|---|---|---| |||||24, 48, or<br>100/110 VDC||||---| ## **Case-surface Mounting** |**Number of poles**||**1 pole**||**2 poles**||**4 poles**| |---|---|---|---|---|---|---| |**Classification**|**Model**|**Rated voltage (V)**|**Model**|**Rated voltage (V)**|**Model**|**Rated voltage (V)**| |**Models with single**<br>**contacts**|**LY1F**|24, 100/110,<br>110/120, 200/220,<br>or 220/240 VAC<br>6, 12, 24, or 100/110<br>VDC|**LY2F**|12, 24, 100/110, 110/<br>120, 200/220,<br>or 220/240 VAC|**LY4F**|12, 24, 100/110,<br>or 200/220 VAC| |||||12, 24, 48, or 100/110<br>VDC||12, 24, or 100/110<br>VDC| |**Bifurcated contacts**|---|---|**LY2ZF**|24, 100/110,<br>or 200/220 VAC|---|---| |||||12 or 24 VDC||| **2** **LY** ## **Accessories (Order Separately) Front-mounting Sockets** |**Applicable**<br>**relay model**|**Mounting**<br>**Method**|**Conductive**<br>**part**<br>**protection**|**Terminal Type**|**Applicable crimp**<br>**terminal/**<br>**Electric wire**|**Appearance**|**Model**|**Hold-down Clips/**<br>**Release Levers**<br>**(Order Separately)**| |---|---|---|---|---|---|---|---| |LY1@<br>LY2@<br>LY2@-CR|Mounted on a<br>DIN track or<br>with screws|Available|Push-In Plus<br>Terminal|Ferrules<br>Solid wire<br>Stranded wire||**PTF-08-PU**<br>* LY2@-CR cannot<br>be used|With release lever<br>* Hold by release<br>lever| |||||||**PTF-08-PU-L**|LY2@-CR: Y92H-3<br>Other than those<br>above: PTC-A1| ||||Screw terminal<br>(M3.5 screw size)<br>~~ar~~|Forked terminals<br>Solid wire<br>Stranded wire<br>~~ar~~||**PTFZ-08-E***|| ||||||~~arac~~|**PTF08A-E***<br>~~ac~~|| |||None||Round terminals<br>Forked terminals<br>Solid wire<br>Stranded wire<br>~~ar~~|~~arac~~|**PTF08A**<br>~~ac~~|| |LY4@||Available|Push-In Plus<br>Terminal<br>~~ar~~|Ferrules<br>Solid wire<br>Stranded wire<br>~~ar~~|~~ar ac~~|**PTF-14-PU-L**<br>~~ac~~|PYC-A1| ||||Screw terminal<br>(M3.5 screw size)<br>~~_~~|Forked terminals<br>Solid wire<br>Stranded wire<br>~~,~~|~~,Jo~~|**PTFZ-14-E***<br>~~Jo~~|| ||||||~~,Jo~~|**PTF14A-E***<br>~~Jo~~|| |||None||Round terminals<br>Forked terminals<br>Solid wire<br>Stranded wire<br>~~,~~<br>~~_~~|~~, Jo~~|**PTF14A**<br>~~Jo~~|| * The PYFZ@A-E and PTF@A-E Relays have finger protection. Round terminals cannot be used. Use forked terminals. **3** **LY** ## **Back-mounting Sockets** |**Applicable relay model**|**Terminal Type**|**Appearance**|**Mode**|**Hold-down Clips**<br>**(Order Separately)**| |---|---|---|---|---| |LY1@<br>LY2@<br>LY2@-CR|Solder terminals||**PT08***|LY2@-CR: PYC-1<br>Other than those above:<br>PYC-P| ||Wrapping terminals||**PT08QN**|| ||PCB terminals||**PT08-0**|| |LY4@|Solder terminals||**PT14***|PYC-P| ||Wrapping terminals||**PT14QN**|| ||PCB terminals||**PT14-0**|| * When ordering PT08, PT11, or PT14 sockets, please note that the minimum order quantity is 10 and orders are accepted in multiples of the minimum order. **4** **LY** ## **Relay Hold-down Clips** |**Application**||**Used with Socket**|**Used with Socket**||**Used with Socket**<br>**mounting plate**|**For models with built-in CR circuits**|**For models with built-in CR circuits**| |---|---|---|---|---|---|---|---| |**Item**|||||||| |**Appearance**||||Approx. 3|Approx. 2.5||| |**Model**|**PYC-A1**||**PYC-P**||**PYC-S**|**Y92H-3**|**PYC-1**| |**Minimum order**<br>**(quantity) ***|100||100||10|10|10| - Orders are accepted in multiples of the minimum order. ## **Socket Mounting Plates** |**Applicable sockets**|**Number of sockets**|**Model**| |---|---|---| |PT08<br>PT08QN|1|**PYP-1 *1**| ||18|**PYP-18 *2**| ||36|**PYP-36 *2**| |PT14<br>PT14QN|1|**PTP-1**| ||10|**PTP-10**| - *1. When ordering PYP-1, please note that the minimum order quantity is 10 and orders are accepted in multiples of the minimum order. - *2. PYP-18 and PYP-36 can be cut to any required length. ## **DIN Track Mounting Parts** |**Type**||**Appearance**|**Model**| |---|---|---|---| |DIN Tracks|Shallow type, total length: 1 m||**PFP-100N**<br>**PFP-50N**| ||Shallow type, total length: 0.5 m||| ||Deep type, total length: 1 m||**PFP-100N2**| |End Plate|||**PFP-M**| |Spacer|||**PFP-S**| **5** **LY** ## **Ratings and Specifications** ## **Ratings** ## **Standard Models with Built-in Operation Indicators Operating Coil, Single-pole and Double-pole Models** |**Item**|**Item**|**Rated current (mA)**|**Rated current (mA)**|**Coil**<br>**resistance**<br>**(**Ω**)**|**Coil inductance (H)**|**Coil inductance (H)**|**Must-operate**<br>**voltage (V)**|**Must-release**<br>**voltage (V)**|**Maximum**<br>**voltage (V)**|**Power**<br>**consumption**<br>**(VA, W)**| |---|---|---|---|---|---|---|---|---|---|---| |**Rated voltage**<br>**(V)**||**50 Hz**|**60Hz**||**Armature**<br>**OFF**|**Armature ON**||||| |**AC**|**12**|106.5|91|46|0.17|0.33|80% max.*1|30% min.*2|110% of<br>rated<br>voltage|Approx. 1.0<br>to 1.2<br>(at 60 Hz)| ||**24**|53.8|46|180|0.69|1.3||||| ||**50**|25.7|22|788|3.22|5.66||||| ||**100/110**|11.7/12.9|10/11|3,750|14.54|24.6||||Approx. 0.9<br>to 1.1<br>(at 60 Hz)| ||**110/120**|9.9/10.8|8.4/9.2|4,430|19.2|32.1||||| ||**200/220**|6.2/6.8|5.3/5.8|12,950|54.75|94.07||||| ||**220/240**|4.8/5.3|4.2/4.6|18,790|83.5|136.4||||| |**DC**|**6**|150||40|0.16|0.33||10% min.*2||Approx. 0.9| ||**12**|75||160|0.73|1.37||||| ||**24**|36.9||650|3.2|5.72||||| ||**48**|18.5||2,600|10.6|21.0||||| ||**100/110**|9.1/10||11,000|45.6|86.2||||| ## **3 poles** |**Item**|**Item**|**Rated current (mA)**|**Rated current (mA)**|**Coil**<br>**resistance**<br>**(**Ω**)**|**Coil inductance (H)**|**Coil inductance (H)**|**Must-operate**<br>**voltage (V)**|**Must-release**<br>**voltage (V)**|**Maximum**<br>**voltage (V)**|**Power**<br>**consumption**<br>**(VA, W)**| |---|---|---|---|---|---|---|---|---|---|---| |**Rated voltage**<br>**(V)**||**50 Hz**|**60Hz**||**Armature**<br>**OFF**|**Armature ON**||||| |**AC**|**12**|159|134|24|0.12|0.21|80% max.*1|30% min.*2|110% of<br>rated<br>voltage|Approx. 1.6<br>to 2.0<br>(at 60 Hz)| ||**24**|80|67|100|0.44|0.79||||| ||**100/110**|14.1/16|12.4/13.7|2,300|10.5|18.5||||| ||**200/220**|9.0/10.0|7.7/8.5|8,650|34.8|59.5||||| |**DC**|**12**|112||107|0.45|0.98||10% min.*2||Approx. 1.4| ||**24**|58.6||410|1.89|3.87||||| ||**48**|28.2||1,700|8.53|13.9||||| ||**100/110**|12.7/13||8,500|29.6|54.3||||| ## **4 poles** |**Item**|**Item**|**Rated current (mA)**|**Rated current (mA)**|**Coil**<br>**resistance**<br>**(**Ω**)**|**Coil inductance (H)**|**Coil inductance (H)**|**Must-operate**<br>**voltage (V)**|**Must-release**<br>**voltage (V)**|**Maximum**<br>**voltage (V)**|**Power**<br>**consumption**<br>**(VA, W)**| |---|---|---|---|---|---|---|---|---|---|---| |**Rated voltage**<br>**(V)**||**50 Hz**|**60Hz**||**Armature**<br>**OFF**|**Armature ON**||||| |**AC**|**12**|199|170|20|0.1|0.17|80% max.*1|30% min.*2|110% of<br>rated<br>voltage|Approx.<br>1.95 to 2.5<br>(at 60 Hz)| ||**24**|93.6|80|78|0.38|0.67||||| ||**100/110**|22.5/25.5|19/21.8|1,800|10.5|17.3||||| ||**200/220**|11.5/13.1|9.8/11.2|6,700|33.1|57.9||||| |**DC**|**12**|120||100|0.39|0.84||10% min.*2||Approx. 1.5| ||**24**|69||350|1.41|2.91||||| ||**48**|30||1,600|6.39|13.6||||| ||**100/110**|15/15.9||6,900|32.0|63.7||||| - **Note: 1.** The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for the AC rated current and ±15% for the DC coil resistance. **2.** The AC coil resistance and inductance values are reference values only. (at 60 Hz). **3.** Operating characteristics were measured at a coil temperature of 23°C. **4.** The maximum voltage capacity was measured at an ambient temperature of 23°C. - *1. There is variation between products, but actual values are 80% max. - To ensure operation, apply at least 80% of the rated value (at a coil temperature of +23° C). - *2. The actual values are 30% min. for AC and 10% min. for DC. To ensure release, use a value that is lower than the specified value. **6** **LY** **Refer to** _**List of Certified Models**_ **for a list of models that are certified for safety standards and the Electrical Appliances and Material Safety Act.** |**Classification**|||**1 pole**||||**Double-, 3-, and 4-pole models**|**Double-, 3-, and 4-pole models**|**Double-, 3-, and 4-pole models**|**Double-, 3-, and 4-pole models**|**Double-, 3-, and 4-pole models**||**Bifurcated contacts**| |---|---|---|---|---|---|---|---|---|---|---|---|---|---| |**Item**<br>**Load**|**Resistive**||**load**<br>**Inductive load**<br>**(cos**φ**= 0.4, L/R = 7 ms)**||||**Resistive load**|**(cos**|**Inductive load**<br> φ**= 0.4, L/R = 7 ms)**<br>**Resistive load**<br>**Inductive load**<br>**(cos**φ**= 0.4, L/R = 7 ms)**||||| |**Contact type**|||||Single||||||||Bifurcated| |**Contact materials**|||||Ag alloy||||||||Ag| |**Rated load**|15 A at 110 VAC<br>15 A at 24 VDC<br>10 A at 110 VAC<br>7 A at 24 VDC||||||10 A at 110 VAC<br>10 A at 24 VDC||7.5 A at 110 VAC<br>5 A at 24 VDC||||5 A at 110 VAC<br>5 A at 24 VDC<br>4 A at 110 VAC<br>4 A at 24 VDC| |**Rated carry current**|||15 A||||10 A||||||7 A| |**Maximum contact voltage**|||250 VAC<br>125 VDC||||250 VAC<br>125 VDC||||||250 VAC<br>125 VDC| |**Maximum contact current**||15 A|15 A||||10 A|||10 A|||7 A<br>7 A| ||||||||||||||| |**Type**|||||**Single-pole, double-pole models**|||||||**Note:**<br>**1.**<br>Some models in the LY1 and LY2 Series have an upper|| |**Item**|**Single-pole and double-pole models**<br>**(standard models and bifurcated contact**<br>**models)**||||**(models with built-in operation indicators, models**<br>**with built-in diodes, and models with built-in CR**<br>**circuits),**<br>**3-pole and 4-pole models**||||||||temperature limit of +40°C. This limitation is due to the<br>diode junction temperature and the elements used.<br>**2.**<br>Refer to_Ambient Temperature vs. Coil Temperature_<br>_Rise_in_Engineering Data_on page 8 to 9 for information<br>on operation in temperature conditions that are not| |**Ambient operating**<br>**temperature**<br>**Ambient operating**<br>**humidity**||−25 to 55°C<br>(with no icing or condensation)*1<br>5% to|||85%||−25 to +40°C<br>(with no icing or condensation)*2||||||described here.<br>**3.**<br>When you apply a minimum of 10 A of current to an LY1<br>when it is used in combination with the PTF-08-PU,<br>PTF-08-PU-L, PTF08A, PTF08A-E, or PT08, connect<br>each of the following terminal pairs: (1) to (2), (3) to (4),| ||||||||||||||and (5) to (6).| |||||||||||||*1.|If the carry current is 4 A or less, the usable ambient temperature| ||||||||||||||range is−25 to 70° C.| |||||||||||||*2.|If the flowing current is 4 A or less, the usable ambient| ||||||||||||||temperature range is -25 to 55° C.| |**Characteristics**|||||||||||||| |||**Type**|**Standard models, models with built-in operation**||||||||||| |**Item**|||**indicators, models with built-in CR circuits, and**||||**Bifurcated contacts**||||||| ||||**models with built-in diodes**||||||||||| |**Contact resistance*1**|||50 mΩmax.|||||||||**Note:**<br>The values at the left are initial values.|| |**Operating time*2**<br>**Release time*2**|||25 ms max.<br>25 ms max.|||||||||*1. <br>*2.|Measurement conditions: 1 A at 5 VDC using the voltage<br>drop method<br> Measurement conditions: With rated operating power| |**Maximum**<br>**operating**<br>**frequency**<br>**Mechanical**<br>**Rated load**<br>**Insulation resistance*3**|||18,000 operations/h<br>1,800 operations/h<br>100 MΩmin.|||||||||*3. <br>*4.|applied, not including contact bounce.<br>Ambient temperature condition: 23° C<br> Measurement conditions: For 500 VDC applied to the<br>same location as for dielectric strength measurement.<br> Ambient temperature condition: 23° C| |**Dielectric**<br>**strength**<br>**Between coil and contacts**<br>**Between contacts of**<br>**different polarity**<br>**Between contacts of**<br>**the same polarity**|||2,000 VAC at 50/60 Hz for 1 min.<br>1,000 VAC at 50/60 Hz for 1 min.|||||||||*5.|This value was measured at a switching frequency of 120<br>operations per minute.| |**Vibration**<br>**Destruction**|||10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)||||||||||| |**resistance**<br>**Malfunction**|||10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)||||||||||| |**Shock**<br>**Destruction**|||1,000 m/s2||||||||||| |**resistance**<br>**Malfunction**|||200 m/s2||||||||||| |**Mechanical**|||AC: 50,000,000 operations min.<br>DC: 100,000,000 operations min.||||(switching frequency: 18,000<br>operations/h)||||||| |**Endurance**<br>**Electrical*4**|||1-, 3-, 4-pole: 200,000 operations min.<br>2-pole: 500,000 operations min.<br>(rated load, operating frequency: 1,800<br>operations/h)||||2-pole: 500,000 operations min.<br>(rated load, operating frequency:<br>operations/h)||1,800||||| |**Failure rate P value (reference value)*5**|||100 mA at 5 VDC||||10mA at 5 VDC||||||| |**Weight**|||1-pole and 2-pole: 40 g, 3-pole: Approx. 50 g, 4-pole: Approx. 70 g||||||||||| ## **Endurance Under Real Loads (Reference Only)** |**Load**<br>**type**<br>**Item**|**LY1, 100 VAC**|**LY1, 100 VAC**||**LY2, 100 VAC**|**LY2, 100 VAC**||**LY4, 100 VAC**|**LY4, 100 VAC**|| |---|---|---|---|---|---|---|---|---|---| ||**Conditions**|**Operating**<br>**frequency**|**Electrical life**<br>**(×10,000**<br>**operations min.)**|**Conditions**|**Operating**<br>**frequency**|**Electrical life**<br>**(×10,000**<br>**operations min.)**|**Conditions**|**Operating**<br>**frequency**|**Electrical life**<br>**(×10,000**<br>**operations min.)**| |**AC motor**|400 W, 100 VAC single-<br>phase with 35-A inrush<br>current, 7-A current<br>flow|ON for 10 s,<br>OFF for 50 s|5|200 W, 100 VAC single-<br>phase with 25-A inrush<br>current, 5-A current<br>flow|ON for 10 s,<br>OFF for 50 s|20|200 W, 200 VAC three-<br>phase with 5-A inrush<br>current, 1-A current<br>flow|ON for 10 s,<br>OFF for 50 s|50| ||||||||750 W, 200 VAC three-<br>phase with 18-A inrush<br>current, 3.5-A current<br>flow||7| |**AC lamp**|300 W, 100 VAC with<br>51-A inrush current, 3-<br>A current flow|ON for 5 s,<br>OFF for 55 s|10|300 W, 100 VAC with<br>51-A inrush current, 3-<br>A current flow|ON for 5 s,<br>OFF for 55 s|8|300 W, 100 VAC with<br>51-A inrush current, 3-<br>A current flow|ON for 5 s,<br>OFF for 55 s|5| ||500 W, 100 VAC with<br>78-A inrush current, 5-<br>A current flow||2.5||||||| |**Capacitor**<br>**(2,000 µF)**|24 VDC with 50-A<br>inrush current, 1-A<br>current flow|ON for 1 s,<br>OFF for 6 s|10|24 VDC with 50-A<br>inrush current, 1-A<br>current flow|ON for 1 s,<br>OFF for 15 s|1|24 VDC with 50-A<br>inrush current, 1-A<br>current flow|ON for 1 s,<br>OFF for 15 s|0.5| |||||24 VDC with 20-A<br>inrush current, 1-A<br>current flow||15|24 VDC with 20-A<br>inrush current, 1-A<br>current flow|ON for 1 s,<br>OFF for 2 s|20| |**AC solenoid**|50 VA with 2.5-A inrush<br>current, 0.25-A current<br>flow|ON for 1 s,<br>OFF for 2 s|150|50 VA with 2.5-A inrush<br>current, 0.25-A current<br>flow|ON for 1 s,<br>OFF for 2 s|100|50 VA with 2.5-A inrush<br>current, 0.25-A current<br>flow|ON for 1 s,<br>OFF for 2 s|100| ||100 VA with 5-A inrush<br>current, 0.5-A current<br>flow||80|100 VA with 5-A inrush<br>current, 0.5-A current<br>flow||50|100 VA with 5-A inrush<br>current, 0.5-A current<br>flow||50| **7** **LY** ## **Details on Safety-standard-certified Models, LY** @ - Standard models are certified for the UL, CSA, and SEV safety standards. - Refer to _Model Number Structure_ on page 1 for a list of applicable models. - The rated values for safety standard certification are not the same as individually defined performance values. Always check the specifications before use. ## **UL-certified Models (File No. E41643)** |**Model**|**Coil ratings**|**Number of**<br>**poles**|**Contact ratings**|**Certified number**<br>**of operations**| |---|---|---|---|---| |**LY**|6 to 240VAC<br>6 to 125VDC|1|15A, 120VAC (General use)|100,000 operations| ||||15A, 240VAC (General use)|6,000 operations| ||||15A, 30VDC (Resistive)|| ||||1/2HP, 120VAC|100,000 operations| ||||8.5FLA, 30LRA, 120VAC|| ||||TV-5, 120VAC|25,000 operations| ||||470VA, Pilot duty, 120VAC|6,000 operations| ||6 to 240VAC<br>6 to 125VDC|2|15A, 120VAC (General use)|100,000 operations| ||||12A, 240VAC (General use)|6,000 operations| ||||7A, 250VAC (General use)|| ||||15A, 30VDC (Resistive)|| ||||5A, 38VDC (Resistive)|| ||||1/2HP, 120VAC|100,000 operations| ||||1/3HP, 240VAC|1,000 operations| ||||8.5FLA, 30LRA, 120VAC|100,000 operations| ||||5FLA, 50LRA, 50VDC|| ||||TV-3, 120VAC|25,000 operations| ||||345VA, Pilot duty, 120-240VAC|6,000 operations| ||||B300/R300|| ||6 to 240VAC<br>6 to 125VDC|3<br>4|10A, 240VAC (General use)<br>(Same polarity)|6,000 operations| ||||10A, 30VDC (General use)<br>(Same polarity)|| ||||2A, 40VDC (Resistive)<br>(Same polarity)|| ||||1/2HP, 240VAC|1,000 operations| ||||0.6A, 100VDC (Resistive)<br>(Same polarity)|6,000 operations| ## **CSA-certified Models (File No. LR31928)** |**Model**|**Coil ratings**|**Number of**<br>**poles**|**Contact ratings**|**Certified number**<br>**of operations**| |---|---|---|---|---| |**LY**|6 to 240VAC<br>6 to 125VDC|1|15A, 120VAC (General use)|100,000 operations| ||||15A, 240VAC (General use)|6,000 operations| ||||15A, 30VDC (Resistive)|| ||||1/2HP, 120VAC|100,000 operations| ||||8.5FLA, 30LRA, 120VAC|| ||||TV-5, 120VAC|25,000 operations| ||||470VA, Pilot duty, 120VAC|6,000 operations| ||6 to 240VAC<br>6 to 125VDC|2|15A, 120VAC (General use)|6,000 operations| ||||12A, 240VAC (General use)|| ||||7A, 250VAC (General use)|| ||||15A, 30VDC (Resistive)|| ||||5A, 38VDC (Resistive)|| ||||1/2HP, 120VAC|100,000 operations| ||||1/3HP, 240VAC|1,000 operations| ||||8.5FLA, 30LRA, 120VAC|100,000 operations| ||||5FLA, 50LRA, 50VDC|| ||||TV-3, 120VAC|25,000 operations| ||||345VA, Pilot duty, 120-240VAC|6,000 operations| ||||B300/R300 Pilot duty|| ||6 to 240VAC<br>6 to 125VDC|3<br>4|10A, 240VAC (General use)<br>(Same polarity)|6,000 operations| ||||10A, 30VDC (Resistive)<br>(Same polarity)|| ||||1/8HP, 240VAC (Same polarity)|1,000 operations| ||||1/2HP, 240VAC (Same polarity)|| ||||1/3HP, 240VAC (Same polarity)|| ||||2A, 40VDC (Resistive)|6,000 operations| ||||0.6A, 100VDC (Resistive)|| ## **TÜV-certified Models (File No. R50030064, EN 61810-1)** |**Model**|**Coil ratings**|**Number of**<br>**poles**|**Contact ratings**|**Certified number**<br>**of operations**| |---|---|---|---|---| |**LY**@|6 to 240 VAC<br>6 to 110 VDC|1|15 A, 110 VDC resistive load|200,000<br>operations| ||||10 A, 110 VAC inductive load|| ||||10 A, 250 VAC resistive load|| ||||7A, 250 VAC inductive load|| ||||10 A, 30 VDC resistive load|| ||||7 A, 30 VDC inductive load|| |||2|10 A, 110 VAC resistive load|| ||||7.5A, 110 VAC inductive load|| ||||7A, 250 VAC resistive load|| ||||4 A, 250 VAC inductive load|| ||||7 A, 30 VDC resistive load|| ||||4 A, 30 VDC inductive load|| |||3<br>4|10 A, 110 VAC resistive load|100,000<br>operations| ||||7.5A, 110 VAC inductive load|| **8** **LY** - When ordering a model that is certified for VDE or Lloyd’s Register (LR) standards, always specify “VDE-certified Model” or “LR Standard-certified Model” with your order. ## **VDE Certification (Certificate No. 6359, EN 61810-1)** |**Model**|**Coil ratings**|**Number of**<br>**poles**|**Contact ratings**|**Certified number**<br>**of operations**| |---|---|---|---|---| |**LY**@**-VD**|6, 12, 24, 50,<br>110, or 220 VAC<br>6, 12, 24, 48,<br>or 110 VDC|1|10 A, 220 VAC resistive load|200,000<br>operations| ||||7 A, 220 VAC inductive load|| ||||10 A, 28 VDC resistive load|| ||||7 A, 28 VDC inductive load|| |||2|7 A, 220 VAC resistive load|| ||||4 A, 220 VAC inductive load|| ||||7 A, 28 VDC resistive load|| ||||4 A, 28 VDC inductive load|| ## **Compliance with Electrical Appliances and Material Safety Act, LY** @ All standard models comply with the Electrical Appliances and Material Safety Act. |**Model**|**Coil ratings**|**Number of**<br>**poles**|**Contact ratings**| |---|---|---|---| |**LY**@|6 to 240 VAC<br>6 to 120 VDC|1|15 A at 200 VAC| |||2<br>3<br>4|10A at 200 VAC| ## **LR-certified Models (File No. 00/10047)** |**Model**|**Coil ratings**|**Number of**<br>**poles**|**Contact ratings**| |---|---|---|---| |**LY**@|6 to 240 VAC<br>6 to 110 VDC|2|7.5 A, 230 VAC inductive load| |||4|5 A, 24 VDC inductive load| ## **Details on Safety-standard-certified Models, Sockets** ## **UL-certified Models (File No. E87929)** |**Model**|**Ratings**|**Listed/Recognized**| |---|---|---| |**PTF-08-PU**|10A 250V|Recognized| |**PTF-14-PU**|10A 250V (Same polarity)|| |**PTFZ-08-E**|15A 250V (at 50 deg)<br>12A 250V (at 70 deg)|| |**PTFZ-14-E**||| |**PTF08A(-E)**<br>**PT08**|15A 250V|| |**PTF11A**<br>**PTF14A(-E)**<br>**PT11**<br>**PT14**|10A 250V|| ## **CSA-certified Models (File No. LR31928)** |**Model**|**Ratings**|**Class number**| |---|---|---| |**PTF-08-PU**|10A 250V|3211 07| |**PTF-14-PU**|10A 250V (Same polarity)|| |**PTFZ-08-E**|15A 250V (at 50 deg)<br>12A 250V (at 70 deg)|| |**PTFZ-14-E**||| |**PTF08A(-E)**|15A 240V AC|| |**PTF11A**<br>**PTF14A(-E)**|10A 240V AC|| ## **CE Marking Compliance** |**Model**|**EMC Directive**|**Low Voltage Directive**|**Machinery Directive**|**Safety Category**| |---|---|---|---|---| |**PTFZ-08-E**|Not applicable|❍|Not applicable|1| |**PTFZ-14-E**||||| |**PTF08A(-E)**||||| |**PTF14A(-E)**||||| **Note: 1.** CE compliance is achieved when used with a relay (LY). **2.** The Safety Category refers to the maximum applicable category selected when constructing control system safety components. The category does not apply to individual components. ## **TÜV Rheinland certification** |**Model**|**Ratings**|**Standard number**|**Certification number**| |---|---|---|---| |**PTF-08-PU**|10A 250V*1|EN 61984|R50327595| |**PTF-14-PU**|10A 250V*2||| |**PTFZ-08-E**|15A 250V (at 50 deg)<br>12A 250V (at 70 deg)||R50438680| |**PTFZ-14-E**|||| - *1. Ratings are for an ambient temperature of 55°C. At an ambient temperature of 70°C, the value is 7A. - *2. Ratings are for an ambient temperature of 40°C. At an ambient temperature of 70°C, the value is 7A. **9** **LY** ## **Engineering Data** ## **Engineering Data** **==> picture [504 x 686] intentionally omitted <==** **----- Start of picture text -----**<br> Maximum Switching Capacity<br>LY1 LY2 LY3 and LY4<br>15 AC AC AC<br>10 resistive load 10 resistive load 10 resistive load<br>5 Life: 5 Life: 5 Life:<br>AC inductive load (cos φ = 0.4) 200,000 operations AC inductive load 500,000 operations AC inductive load 200,000 operations<br>(cos φ = 0.4) (cos φ = 0.4)<br>1 DC inductive load (L/R = 7 ms) 1 DC inductive load (L/R = 7 ms) 1 DC inductive load (L/R = 7 ms)<br>0.5 0.5 0.5<br>DC DC DC<br>resistive load resistive load resistive load<br>0.1 0.1 0.1<br>0 5 10 50 100 500 1,000 0 5 10 50 100 500 1,000 0 5 10 50 100 500 1,000<br>Contact voltage (V) Contact voltage (V) Contact voltage (V)<br>Endurance Curve<br>LY2Z LY1 LY2<br>10 AC resistive load<br>5 AC inductive load (cos φ = 0.4)<br>1,000 1,000 24 VDC<br>1 DC resistive load 500 110 VAC resistive load 500 resistive load<br>110 VAC<br>0.5 24 VDC resistive load<br>D (L/R = 7 ms) C inductive load 100 resistive load 100<br>50 50<br>110 VAC inductive load<br>0.1 (cos φ = 0.4)<br>Life: 500,000 operations 10 24 VDC inductive load 110 VAC inductive load (cos φ = 0.4) 10 24 VDC inductive load (L/R = 7 ms)<br>(L/R = 7 ms)<br>0 5 10 50 100 500 1,000 0 2 4 6 8 10 12 14 16 18 20 0 2 4 6 8 10 12 14 16 18 20<br>Contact voltage (V) Switching current (A) Switching current (A)<br>Ambient Temperature vs. Must-<br>operate and Must-release Voltage<br>LY3 and LY4 LY2Z LY2 100/110 VAC at 50Hz<br>100 Number of Relays: 5 Must-operate voltage<br>(average value) Must-release voltage<br>80<br>1,000 1,000 24 VDC<br>500 24 VDC resistive load 500 resistive load110 VAC 60<br>resistive load<br>110 VAC 110 VAC inductive load<br>100 resistive load 100 (cos φ = 0.4) 40<br>110 VAC inductive load<br>50 (cos φ = 0.4) 50<br>24 VDC inductive load (L/R = 7 ms) 20<br>10 24 VDC inductive load (L/R = 7 ms) 10<br>0<br>0 2 4 6 8 10 12 14 16 18 20 0 2 4 6 8 10 −40 −20 0 20 40 60 80<br>Switching current (A) Switching current (A) Ambient temperature (°C)<br>Ambient Temperature vs. Coil<br>Temperature Rise<br>LY2 24 VDC LY1 24 VDC LY1 100/110 VAC at 50Hz<br>100 Number of Relays: Must-operate voltage 120 Rating: 100% applied 120 Rating: 100% applied<br>5 (average value) Must-release voltage 110 Rated power consumption: 1 W 110 Rated power consumption: 1 VA<br>100 100<br>80<br>90 Maximum operating 90 Maximum operating<br>80 15 A temperature (120° C) 80 15 A temperature (120° C)<br>60 70 10 A 70 10 A<br>60 60 7 A<br> 7 A 5 A<br>40 50 5 A 3 A 50 3 A<br>40 No contact current 40 No contact current<br>30 30<br>20 20 20<br>10 10<br>0<br> −40 −20 0 20 40 60 80 0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80<br>Ambient temperature (°C) Ambient temperature (°C)<br>Ambient temperature (°C)<br>Contact current (A) Contact current (A) Contact current (A)<br>4 operations) 4 operations)<br>Contact current (A)<br>Number of operations (×10<br>Number of operations (×10<br>4 operations) 4 operations)<br>Number of operations (×10 Number of operations (×10 Must-operate/must-release voltage (%)<br>Must-operate/must-release voltage (%) Coil temperature rise (°C) Coil temperature rise (°C)<br>**----- End of picture text -----**<br> **10** **LY** ## **LY2** 24 VDC ## **LY2** 100/110 VAC at 50Hz ## **LY3** 24 VDC **==> picture [484 x 282] intentionally omitted <==** **----- Start of picture text -----**<br> 120 120 120<br>110 Rating: 100% appliedRated power consumption: 1 W 110 Rating: 100% appliedRated power consumption: 1.0 VA 110 Rating: 100% appliedRated power consumption: 1.4 VA<br>100 100 100<br>90 Maximum operating temperature (120° C) 90 Maximum operating temperature (120° C) 90 10 A Maximum operating temperature (120° C)<br>80 80 80<br>70 10 A 70 10 A 70 7 A<br>60 7 A 60 7 A 60 5 A<br>50 5 A 50 5 A 50 3 A<br>40 3 A 40 3 A 40<br>No contact current<br>30 No contact current 30 No contact current 30<br>20 20 20<br>10 10 10<br>0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80<br>Ambient temperature (°C) Ambient temperature (°C) Ambient temperature (°C)<br>100/110 VAC at 50Hz LY4 24 VDC LY4 100/110 VAC at 50Hz<br>120 120 120<br>110 Rating: 100% appliedRated power consumption: 1.6 VA 110 Rating: 100% appliedRated power consumption: 1.5 W 110 Rating: 100% appliedRated power consumption: 1.95 VA<br>100 100 100<br>90 10 A Maximum operating temperature (120° C) 90 10 A Maximum operating temperature (120° C) 90 10 A Maximum operating temperature (120° C)<br>80 80 80<br>70 7 A 70 7 A 70 7 A<br>60 5 A 60 5 A 60 5 A<br>50 3 A 50 3 A 50 3 A<br>40 No contact current 40 No contact current 40 No contact current<br>30 30 30<br>20 20 20<br>10 10 10<br>0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80<br>Ambient temperature (°C) Ambient temperature (°C) Ambient temperature (°C)<br>Coil temperature rise (°C) Coil temperature rise (°C) Coil temperature rise (°C)<br>Coil temperature rise (°C) Coil temperature rise (°C) Coil temperature rise (°C)<br>**----- End of picture text -----**<br> ## **LY3** 100/110 VAC at 50Hz ## **Models with built-in diodes** The diode absorbs surge from the coil. With Diode **==> picture [124 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> ON OFF<br>A<br>24 VDC<br>Di [To digital ]<br>memory<br>A’<br>**----- End of picture text -----**<br> ## Without Diode **==> picture [124 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> ON OFF<br>140 V<br>A<br>24 VDC To digital<br>memory<br>A’<br>**----- End of picture text -----**<br> - **Note: 1.** Make sure that the polarity is correct. **2.** The release time will increase, but the 25-ms specification for standard models is satisfied. **3.** Diode characteristics: Reversed dielectric strength: 1,000 V Forward current: 1 A ## **Models with Built-in CR Circuits** ## With CR **==> picture [124 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> 282 V<br>80 V<br>4.12 ms<br>9.4 ms<br>A<br>200 AC C = 0.033 μF<br>R = 120 Ω<br>A’<br>**----- End of picture text -----**<br> ## Without CR **==> picture [124 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> 282 V<br>2.5<br>ms ec<br>600 V<br>A<br>To digital<br>200 AC memory<br>scope<br>A’<br>**----- End of picture text -----**<br> **11** **LY** ## **Malfunctioning Shock** ## **LY2** 100/110 VAC Y **==> picture [410 x 128] intentionally omitted <==** **----- Start of picture text -----**<br> 560 EnergizedNot energized N = 20Measurement: Shock was applied 2 times each in 6 directions along 3 axes<br>440 720 with the Relay energized and not energized to check the shock values that<br>X 500 520 Z cause the Relay to malfunction.<br>370 Criteria: Non-energized: 200 m/s [2] , Energized: 200 m/s [2]<br>350 Shock direction<br>520 450 X X'<br>700<br>Z' X' Y<br>Z<br>500<br>Z'<br>600 Unit: m/s [2] Y'<br>Y'<br>**----- End of picture text -----**<br> ## **Dimensions** **(Unit: mm)** ## **Relays** ## **Solder terminals** **==> picture [505 x 245] intentionally omitted <==** **----- Start of picture text -----**<br> LY1 Terminal Arrangement/Internal Connections (Bottom View)<br>LY1N LY1 LY1-D<br>LY1-D<br>LY1N-D2<br>0.5<br>Eight, 2-dia. holes 2 8 max.<br>(The coil has no polarity.)<br>5<br>(Check the coil polarity when wiring<br>3 2 1.5 max . and wire all connections correctly.)<br>3 6 max . 6.4<br>LY1N<br>DC Models AC Models LY1N-D2<br>Note: 1. For the DC models, check the coil polarity<br>when wiring and wire all connections<br>correctly.<br>2. The indicator is red for AC and green for DC.<br>3. The operation indicator indicates the<br>energization of the coil and does not<br>represent contact operation. Check the coil polarity when wiring and wire all connections (The coil has no polarity.) Check the coil polarity when wiring<br>correctly. and wire all connections correctly.<br>**----- End of picture text -----**<br> **LY2 LY2-D LY2Z LY2Z-D LY2N LY2N-D2 LY2ZN LY2ZN-D2** **==> picture [258 x 241] intentionally omitted <==** **----- Start of picture text -----**<br> Terminal Arrangement/Internal Connections (Bottom View)<br>LY2(Z) LY2(Z)-D<br>(The coil has no polarity.)<br>Check the coil polarity when wiring and wire all<br>connections correctly.<br>LY2(Z)N<br>DC Models AC Models LY2(Z)N-D2<br>Check the coil polarity when (The coil has no polarity.)<br>wiring and wire all connections Check the coil polarity when wiring<br>correctly. and wire all connections correctly.<br>**----- End of picture text -----**<br> **==> picture [172 x 64] intentionally omitted <==** **----- Start of picture text -----**<br> 0.5<br>Eight, 3-dia. holes 2 8 max.<br>5<br>3 2 1.5 max .<br>3 6 max . 6.4<br>**----- End of picture text -----**<br> **==> picture [167 x 24] intentionally omitted <==** **----- Start of picture text -----**<br> Note: 1. For the DC models, check the coil polarity<br>when wiring and wire all connections<br>correctly.<br>**----- End of picture text -----**<br> **2.** The indicator is red for AC and green for DC. **==> picture [127 x 24] intentionally omitted <==** **----- Start of picture text -----**<br> 3. The operation indicator indicates the<br>energization of the coil and does not<br>represent contact operation.<br>**----- End of picture text -----**<br> **12** **LY** **==> picture [497 x 250] intentionally omitted <==** **----- Start of picture text -----**<br> LY4<br>Terminal Arrangement/Internal Connections (Bottom View)<br>LY4N LY4 LY4-D<br>LY4-D<br>LY4N-D2<br>0.5<br>2 8 max.<br>5 (The coil has no polarity.)<br>3 4 1.5 max . Check the coil polarity when wiring<br>3 6 max . 6.4 Fourteen, 3-dia. holes and wire all connections correctly.<br>LY4N-D2<br>LY4N<br>DC Models AC Models<br>Check the coil polarity when wiring<br>and wire all connections correctly.<br>Check the coil polarity when (The coil has no polarity.)<br>wiring and wire all connections<br>correctly.<br>**----- End of picture text -----**<br> **==> picture [310 x 16] intentionally omitted <==** **----- Start of picture text -----**<br> Note: 1. For the DC models, check the coil polarity when wiring and wire all connections correctly.<br>2. The indicator is red for AC and green for DC.<br>**----- End of picture text -----**<br> **3.** The operation indicator indicates the energization of the coil and does not represent contact operation. **==> picture [495 x 109] intentionally omitted <==** **----- Start of picture text -----**<br> LY2-CR<br>Terminal Arrangement/Internal Connections (Bottom View)<br>LY2Z-CR<br>LY2(Z)-CR LY2(Z)N-CR<br>LY2N-CR<br>LY2ZN-CR 0.5<br>Eight, 3-dia. holes* 2 8 max.<br>5<br>3 21.5 max . CR element<br>C = 0.033 μF<br>5 3 max . 6.4 R = 120 Ω<br>*These dimensions are for the LY2N-CR. (The coil has no polarity.)<br>**----- End of picture text -----**<br> ## **Relays with PCB Terminals** **LY1-0, LY3-0, LY2-0, and LY4-0** **==> picture [158 x 39] intentionally omitted <==** **----- Start of picture text -----**<br> 28 max.<br>21.5 max.<br>36 max.<br>**----- End of picture text -----**<br> **==> picture [210 x 16] intentionally omitted <==** **----- Start of picture text -----**<br> Note: The figures and dimensions depicted here are for the LY2-0.<br>The dimension with an asterisk (*) is 6.4 for the LY1-0.<br>**----- End of picture text -----**<br> **==> picture [218 x 109] intentionally omitted <==** **----- Start of picture text -----**<br> PCB Processing Dimensions (Bottom View)<br>1 pole 2 poles 3 poles 4 poles<br>Five, 2.5-dia. holes Eight, 2.5-dia. holes Eleven, 2.5-dia. holes Fourteen, 2.5-dia. h<br>Note: 1. The dimensional tolerance is 0.1 mm.<br>**----- End of picture text -----**<br> **2.** There are exposed parts (conductive parts) on the LY1-0 other than the terminals. Be careful when using this Relay on a double-sided PCBs. **==> picture [220 x 93] intentionally omitted <==** **----- Start of picture text -----**<br> Terminal Arrangement/Internal Connections (Bottom View)<br>LY1-0 LY2-0 LY3-0 LY4-0<br>2<br>3<br>6<br>7 8<br>(The coil has no polarity.)<br>**----- End of picture text -----**<br> **13** **LY** ## **Case-surface mounting** **==> picture [495 x 100] intentionally omitted <==** **----- Start of picture text -----**<br> LY1F Mounting Hole Terminal Arrangement/Internal<br>LY2F 22.5 max. Dimensions Connections (Bottom View)<br>LY1F LY2F<br>44 max.<br>29 max.<br>Eight, 2-dia. holes* Two, 3.5-dia. holes or<br>35.5 max. two M3 screw holes (The coil has no polarity.)<br>**----- End of picture text -----**<br> **Note:** The figures and dimensions depicted here are for the LY1F. The LY2F is also conforms to these measurements. **==> picture [91 x 14] intentionally omitted <==** **----- Start of picture text -----**<br> Note: The dimensional<br>tolerance is ±0.1 mm.<br>**----- End of picture text -----**<br> ## **LY4F** **==> picture [393 x 116] intentionally omitted <==** **----- Start of picture text -----**<br> Mounting Hole Terminal Arrangement/Internal<br>41.5 max. Dimensions Connections (Bottom View)<br>LY4F<br>Three, 3.5 dia. holes or<br>two M3 screw holes<br>28 max. 44 max.<br>Fourteen, 3-dia. holes (The coil has no polarity.)<br>35.5 max.<br>**----- End of picture text -----**<br> **14** **LY** ## **Accessories (Order Separately)** ## **Socket Characteristics** |**Model**|**Continuous**<br>**carry current**|**Dielectric strength**|**Insulation**<br>**resistance***1|**Remarks**| |---|---|---|---|---| |PTF-@-PU(L)|10 A|Between contact terminals of same polarity: 2,000 VAC, 1 min|1,000 MΩmin.|| |||Between contact terminals of different polarity: 2,000 VAC, 1 min||| |||Between coil and contact terminals: 2,000 VAC, 1 min||| |PTFZ-@@-E|12 A (@70°C)<br>15 A (@50°C)*2|Between contact terminals of different polarity: 2,500 VAC, 1 min|1,000 MΩmin.|| |||Between contact terminals of same polarity: 2,500 VAC, 1 min||| |||Between ground terminals: 2,500 VAC, 1 min||| |||Between coil and contact terminals: 2,500 VAC, 1 min||| |PTF@@A(-E)|10 A|Between terminals: 2,000 VAC for 1 min|100 MΩmin.|| |PT-@@|10 A|Between terminals: 2,000 VAC for 1 min|100 MΩmin.|| |PT@@-0|10 A|Between terminals: 2,000 VAC for 1 min|100 MΩmin.|| |PT@@QN|10 A|Between terminals: 2,000 VAC for 1 min|100 MΩmin.|| - *1. The insulation resistance was measured with a 500-VDC insulation resistance meter at the same places as those used for measuring the dielectric strength. - *2. However, do not exceed the continuous carry current of the socket to be mounted. ## **Connection Sockets** **==> picture [511 x 204] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions Terminal Arrangement/Internal Connections Mounting Hole Dimensions<br>ee PTF-08-PU(-L) 66.2 Two, M3 screw hole or two, 3.5 dia. hole<br>48.2<br>45 21(6) (5)11<br>36.3 24 14<br>27.6 3.9 (4) (3)<br>(4.2) 22 12<br>(2) (1)<br>108<br>90<br>35.3<br>(8) (7)<br>A2 A1<br>27.4<br>(Top View)<br>Release lever *<br>(4.2)<br>Note: The numbers in (Top View)<br>24.8 27.6 parentheses are<br>28.1 traditionally used Note: Pull out the hooks to mount<br>30.3 terminal numbers. the Relay with screws.<br>**----- End of picture text -----**<br> - The PTF-08-PU-L Sockets do not have release levers. **15** **LY** **==> picture [499 x 621] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions Terminal Arrangement/Internal Connections Mounting Hole Dimensions<br>PTF08A Two, 4.5 × 6 mounting holes 7 [±0.2] 3.4<br>8-M3.5×8<br>F e) ——<br>G<br>G 78.5 max. [es 35.5<br>ala j 1 Tl<br>8<br>28.5 max.<br>=] 3 0 max oe .<br>PTFZ-08-E (Finger Protection Structure)<br>Two, 4.5 × 6 7 3.4<br>mounting holes<br>8-M3.5×7 Two, 4.5 dia. or<br>M4 mounting holes<br>2 1<br>4 3<br>78.5 max. 35.5<br>: lel Qo 68 [±0.3] j |<br>SARS) 6 5<br>Peet 8 7<br>8<br>28.5 max. 33 max. (Top View) 19 [±0.2]<br>“Tr -<br>(Top View)<br>PTF08A-E (Finger Protection Structure)<br>Two, 4.5 × 6 mounting holes 8-M3.5×8 3.4 Note: Track mounting is also<br>BAw . + (Obpash L possible.<br>a>BLS| o rd fo} J<br>loco )<br>78.5 max. 35.5<br>1<br>e21 4] ie<br>8<br>28.5 max.<br>|__| 3 3 max _ r .<br>PTF-14-PU-L<br>Two, M3 screw hole or<br>_ 48.2 (12) Ooo 41 (11)31 21(10) o 11(9) two, 3.5 dia. hole<br>45 44 34 24 14<br>_ 36.3 ~ (8) LJCI (7) CI (6) C (5) /<br>43.4<br>P 27.6 3.9 42 32 22 12<br>(4.2) = se | (4) (3) (2) (1)<br>27.4<br>108<br>90<br>35.3<br>(14) (13)<br>A2 A1<br>(Top View)<br>(4.2) Po NT<br>27.6 Note: The numbers in (Top View)<br>28.1 parentheses are<br>30.3 traditionally used Note: Pull out the hooks to mount<br>terminal numbers. the Relay with screws.<br>**----- End of picture text -----**<br> **16** **LY** **==> picture [502 x 456] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions Terminal Arrangement/Internal Connections Mounting Hole Dimensions<br>PTF14A<br>Two, 4.5 × 6 mounting holes 7 [±0.2] 3.4<br>14-M3.5×8<br>PD ici!<br>on aD ANSE<br>Sept L H oHoHOHe —<br>y ooaogo<br>rex ‘A) , 78.5 max. nooo a oo a 35.4<br>Sleieiel s<br>e le sl e tollo<br>4 5.5 max . 8<br>3 0 max .<br>PTFZ-14-E (Finger Protection Structure)<br>Two, 4.5 × 6 7 3.4<br>mounting holes<br>14-M3.5×7 Two, 4.5 dia. or M4 mounting holes<br>ee, (Fy<br>DOK: 1 S-O-6-s 4 3 2 1 ;<br>8 7 6 5<br>i<br>an 78.5 max. ——— sooo 35.5 | Doce<br>>. 1 l 68 [±0.3] '<br>12 11 10 9<br>14 13<br>a 45.5 max. ie T 8<br>33 max. (Top View) 36 [±0.2]<br>(Top View)<br>Note: Track mounting is also<br>PTF14A-E (Finger Protection Structure)<br>possible.<br>Two, 4.5 × 6 mounting holes 7 [±0.2] 3.4<br>PS S 7 eect 14-M3.5×8 cH<br>lxf | oeSe G =LO-@-@-O z<br>< i, = ooo ?<br>Ne 74 78.5 max. ——— 35.5<br>l l<br>Le] Fela |<br>4 5.5 max . 8<br>“SH 3 3 max .<br>**----- End of picture text -----**<br> **Note:** If you use the PTF-08-PU, PTF-08-PU-L, PTF08A, PTF08A-E, or PT08 with an LY1 Relay, connect the following terminal pairs: 1-2, 3-4, and 5-6 (for usage at 10 A or higher). **17** **LY** **==> picture [512 x 721] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions Terminal Arrangement/Internal Connections Mounting hole and PCB dimensions<br>PT08<br>5<br>0.3<br>25.5 29.5<br>max. max.<br>2.7 24 max. 2<br>25.8 [±0.2]<br>20.5 max. Eight, 1.7-dia × 3.5 oblong holes<br>PT08QN<br> 021.4 [+0.2]<br>1.5×1.0<br>1 2<br>25.5 29.5<br>1.0 max. max. 3 4<br>2.7 9 2.5 20 1.5 2 5 6<br>3 5 max .<br>24 max. 7 8<br>PT08-0 (Bottom View)<br>*Maintain a sufficient distance from the<br>2 pattern when using double-sided PCBs. 1 5.6<br>• The structure does not resist flux.<br>Manual soldering is recommended for 1 0<br>this product.<br>0.3 5.35<br>4.6<br>29.5 max. 12.45<br>2 5 [*] 6.45<br>6.5<br>6.5<br>1 4.3<br>22 max. 3 Eight, 2.5-dia. holes<br>18 max. (±0.1 tolerance)<br>PT14<br>0.3<br>5<br>Fourteen, 1.7-dia × 3.5 holes<br>42.5 max.<br>2.7<br>26.5 max.<br>20.5 max. 29.5 max. 41 [±0.2]<br>PT14QN<br>1.5×1.0 26.6 0 [+0.3]<br>13 9 5 1<br>42.5 max. 10 6 2<br>1.5<br>11 7 3<br>9 2.5<br>2.7 20 1.0 14 12 8 4<br>3 5 max .<br>26.5 max.<br>29.5 max. (Bottom View)<br>PT14-0 *Maintain a sufficient distance from the 12.45<br>0.3 pattern when using double-sided PCBs. 4.6<br>• The structure does not resist flux. 6.45<br>Manual soldering is recommended for<br>this product. 5.1 5.8<br>10<br>31.4 10<br>4 2.5 max.<br>2 5 [*]<br>10<br>Fourteen,<br>2.7 4.3 6.4 2.5-dia. holes<br>17.5 max. 26.5 max. 6.4 5.45<br>29.5 max. (±0.1 tolerance)<br>**----- End of picture text -----**<br> **Note:** Use a panel with a thickness of 1 to 2 mm when mounting a Socket on it. **18** **LY** ## **Hold-down Clips** **==> picture [511 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> PYC-A1 PYC-P PYC-S Y92H-3 PYC-1<br>Approx. 0.54 g (per clip) Approx. 1.4 g Approx. 1.8 g Approx. 0.7 g (per clip) Approx. 6 g<br>One Set (2 Clips) One Set (2 Clips)<br>Approx. 5<br>9.4<br>Approx. 5<br>5 8 28<br>A pprox. 29 Approx. 3 28<br>2.5<br>36.3 53<br>38.5 52 58.2<br>4.5<br>4.5 1.2 4.5<br>4.5 1.2<br>**----- End of picture text -----**<br> ## **Socket Mounting Plates (t = 1.6)** OMRON can provide Socket Mounting Plate for convenient Socket installation. Please use these Plates as required. ## **PYP-1** **==> picture [32 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> PYP-18<br>**----- End of picture text -----**<br> **==> picture [32 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> PYP-36<br>**----- End of picture text -----**<br> **==> picture [464 x 130] intentionally omitted <==** **----- Start of picture text -----**<br> 492<br>21.6 17×27.4 = 465.8492 [±0.6] 13.1 72, oval holes 21.6 27.4±0.1527.4×17 = 465.84.3.4 5 R1.7 [±0.6] 13. 1 21.4 [+0.2] 0<br>Two, 3.4-dia. holes 4.5 72, oval holes<br>3.4 R1.7<br>5.1<br>39.7 [±0.2]<br>5.1 42 49 5.1 42 [±0.1] 49 86.4<br>39.7 [±0.2]<br>28 21.6<br>17×27.4 = 465.8 [±0.6]<br>17×27.4 = 465.8 [±0.6] 13.1 21.6<br>27.4×17 = 465.8 [±0.6]<br>**----- End of picture text -----**<br> ## **PTP-1** ## **PTP-10** **==> picture [339 x 105] intentionally omitted <==** **----- Start of picture text -----**<br> 7.4<br>59 R5 9×49.4 = 444.6 [±0.6] 40, oval holes<br>Four,<br>3.4-dia. holes 7.7 7.7<br>42 [±0.1] 49 42 [±0.1] 49<br>R1.7<br>3.4<br>52 [±0.1] 1.1<br>4.5<br>9×49.4 = 444.6 [±0.6] 7.4<br>9×49.4 = 444.6 [±0.6] 23.7<br>492<br>**----- End of picture text -----**<br> **19** **LY** ## **Connection Socket and Hold-down Clip Application Table** ||**Item**|**Front-mounting Sockets**|**Front-mounting Sockets**|**Front-mounting Sockets**|**Front-mounting Sockets**|**Front-mounting Sockets**|**Front-mounting Sockets**|**Back-mounting Sockets**|**Back-mounting Sockets**|**Back-mounting Sockets**| |---|---|---|---|---|---|---|---|---|---|---| |**Applicable Relay**|**Number**<br>**of poles**|**Track or screw mounting**||||||**Solder terminals, wrapping terminals, or**<br>**PCB terminals**||| |||**PTF-**<br>**08-PU**|**PTF-08-**<br>**PU-L**|**PTF08A**|**PTF-14-**<br>**PU-L**|**PTF14A**|**Applicable**<br>**Hold-down**<br>**Clips**|**PT08(QN)**<br>**PT08-0**|**PT14(QN)**<br>**PT14-0**|**Applicable**<br>**Hold-down Clips**| |**•**<br>**Standard models: LY**@<br>**•**<br>**Bifurcated contact models:**<br>**LY**@**Z**<br>**•**<br>**Models with built-in**<br>**operation indicators: LY**@**N**<br>**•**<br>**Models with built-in diodes:**<br>**LY**@**-D(2)**|**1 or 2**|*|||||PYC-A1|||PYC-P| ||**3**|||||||||| ||**4**|||||||||| |**•**<br>**Models with built-in CR**<br>**circuits: LY**@**-CR**|**2**||||||Y92H-3|||PYC-1| - A Release Lever is provided as a standard feature. The hold-down clips are unnecessary. ## **Mounting Height with Sockets** **Front-mounting Sockets** ## **Back-mounting Sockets** **==> picture [311 x 219] intentionally omitted <==** **----- Start of picture text -----**<br> LY<br>66.2 64.1<br> 28.1<br> (3.9)<br>PTF-@-PU<br>LY2 LY4<br>66 70 66 70<br>34 30 34 30<br>PTFZ-08-E PTFZ-14-E<br>**----- End of picture text -----**<br> **Note: 1.** The PTF @ A can be mounted on a track or with screws. **2.** The measurements in parentheses are for the LY @ -CR (built-in CR circuit). **20** **LY** ## **Safety Precautions** **Refer to the** _**Common Relay Precautions**_ **for precautions that apply to all Relays.** ## **Precautions for Correct Use** - Use two M3 screws to attach case-surface-mounted models (LY1F, LY2F, LY3F, and LY4F) and tighten the screws securely. (Normal tightening torque: 0.98 N·m) - For Relays with Tab Terminals, select a wire diameter for the lead wires that connect to the faston receptacle terminals that is within the allowed range for the load current. - Do not impose excessive external force on the Relay when inserting the Relay to the faston receptacle or pulling the Relay out from the faston receptacle. Do not attempt to insert a terminal diagonally or insert or pull out more than one terminal at the same time. - LY Single-contact Relays are for power switching applications. Do not use the LY Series for switching minute loads of 100 mA or less, such as signals. ## **About the Built-in Diode and CR Elements** The diode or CR element that are built into the Relay are designed to absorb the reverse voltage from the Relay coil. If a large surge in voltage is applied to the diode or CR element from an external source, the element will be destroyed. If there is the possibility of large voltage surges that could be applied to the elements from an external source, take any necessary surge absorption measures. ## **Applying 10 A or More When Using an LY1 with the Following Sockets** When you use an LY1 in combination with the PTF-08-PU, PTF-08PU-L, PTF08A, PTF08A-E, or PT08, connect each of the following terminal pairs: (1) to (2), (3) to (4), and (5) to (6). ## **Relay Replacement** To replace the Relay, turn OFF the power supply to the load and Relay coil sides to prevent unintended operation and possible electrical shock. ## **Attaching and Removing Relay Hold-down Clips** When you attach a Hold-down Clip to or remove it from a Socket, wear gloves or take other measures to prevent injuring your fingers on the Hold-down Clip. **21** ## **OMRON AUTOMATION AMERICAS HEADQUARTERS •** Chicago, IL USA **•** 847.843.7900 **•** 800.556.6766 **•** automation.omron.com ## **OMRON CANADA, INC. • HEAD OFFICE** Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • automation.omron.com **OMRON ELECTRONICS DE MEXICO • HEAD OFFICE** Ciudad de México • 52.55.5901.4300 • 01.800.386.6766 • mela@omron.com ## **OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE** São Paulo, SP, Brasil • 55 11 5171-8920 • automation.omron.com ## **OMRON ARGENTINA • SALES OFFICE** Buenos Aires, Argentina • +54.11.4521.8630 • +54.11.4523.8483 mela@omron.com ## **OMRON ELECTRONICS DE MEXICO • SALES OFFICE** San Pedro Garza García, N.L. • 81.12.53.7392 • 01.800.386.6766 • mela@omron.com ## **OTHER OMRON LATIN AMERICA SALES** +54.11.4521.8630 • +54.11.4523.8483 • mela@omron.com ## **OMRON ELECTRONICS DE MEXICO • SALES OFFICE** Eugenio Garza Sada,León, Gto • 01.800.386.6766 • mela@omron.com _Authorized Distributor:_ ## **Controllers & I/O** - Machine Automation Controllers (MAC) • Motion Controllers - Programmable Logic Controllers (PLC) • Temperature Controllers • Remote I/O **Robotics** • Industrial Robots • Mobile Robots ## **Operator Interfaces** - Human Machine Interface (HMI) ## **Motion & Drives** - Machine Automation Controllers (MAC) • Motion Controllers • Servo Systems • Frequency Inverters ## **Vision, Measurement & Identification** - Vision Sensors & Systems • Measurement Sensors • Auto Identification Systems **Sensing** • Photoelectric Sensors • Fiber-Optic Sensors • Proximity Sensors • Rotary Encoders • Ultrasonic Sensors **Safety** - Safety Light Curtains • Safety Laser Scanners • Programmable Safety Systems • Safety Mats and Edges • Safety Door Switches • Emergency Stop Devices • Safety Switches & Operator Controls • Safety Monitoring/Force-guided Relays **Control Components** • Power Supplies • Timers • Counters • Programmable Relays • Digital Panel Meters • Monitoring Products ## **Switches & Relays** - Limit Switches • Pushbutton Switches • Electromechanical Relays • Solid State Relays ## **Software** - Programming & Configuration • Runtime Note: Specifications are subject to change. © 2022 Omron. All Rights Reserved. Printed in U.S.A.
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →