LTC 600-SF
Current Transducer, Closed Loop Hall Effect, AC/DC/Pulsed, 500A, Analogue-100mA, ± 15V to 24V Supply
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- SVHC: No SVHC (25-Jun-2025)
- Accuracy: ± 0.7%
- Product Range: LTC Series
- Primary Current: 500A
- Sensor Mounting: Panel Mount
- Measured Current: AC / DC / Pulsed
- Sensor Output Type: Analogue
- Supply Voltage Range: ± 15V to 24V
- Secondary Signal Type: 100mA
- Current Sensor Technology: Closed Loop Hall Effect
- Operating Temperature Max: 85°C
- Operating Temperature Min: -40°C
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 177.27 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Current Transducer LTC 600-SF** ## _I_ **= 500 A** P N For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. ## ~~**Electrical data**~~ |_I_P N|Primary nominal RMS current||500|||A| |---|---|---|---|---|---|---| |_I_P M|Primary current, measuring range|@ ±24 V|0 ... ±1500|||A| |_Î_P max|Primary withstand peak current (maximum)||10/10|||kA/ms| |_R_M|Measuring resistance||_R_M min|_R_M max||| ||with ±15 V<br>@ ±500 Amax||0||70|Ω| ||@ ±1200 Amax||0||5|Ω| ||with ±24 V<br>@ ±500 Amax||0|150||Ω| ||@ ±1500 Amax||0||20|Ω| |_I_S N|Secondary nominal RMS current||100|||mA| |_N_P/_N_S|Turns ratio||1 : 5000|||| |_U_C|Supply voltage (±5 %)||±15 ...|24||V| |_I_C|Current consumption||< 32(@ ±24 V)+|||_I_SmA| |~~**Accuracy - Dynamic performance data**~~||||||| |_ε_tot|Total error @_I_P N,_T_A= 25 °C||< ±0.7|||%| ||@_I_P N,_T_A= −40 °C ... +85 °C||< ±1.6|||%| |_ε_L|Linearity error||< 0.1|||%| ||||Max|||| |_I_O|Ofset current @_I_P= 0,_T_A= 25 °C||±0.5|||mA| |_I_O_T_|Temperature variation of_I_O|−40 °C ... +85 °C|±1|||mA| |_t_D 90|Delay time to 90 % of the fnal output value for_I_P Nstep||1)< 1|||µs| |_BW_|Frequency bandwidth (−1 dB)||DC ... 100|||kHz| |~~**General data**~~||||||| |_T_A|Ambient operating temperature||−40 ...|+85||°C| |_T_A st|Ambient storage temperature||−45 ...|+90||°C| |_R_S|Resistance of secondary winding @_T_A= 85 °C||44|||Ω| |_m_|Mass||780|||g| ||Standards||EN 50155: 20172)|||| ||||UL 508:||2010|| ||||EN 50121-3-2: 2016|||| ## **Features** - ●Closed loop (compensated) current transducer using the Hall effect - ●Insulating plastic case recognized according to UL 94-V0. ## **Advantages** - ●Excellent accuracy - ●Very good linearity - ●Low temperature drift - ●Optimized response time - ●Wide frequency bandwidth - ●No insertion losses - ●High immunity to external interference - ●Current overload capability. ## **Applications** - ●Single or three phase inverters - ●Propulsion and braking choppers - ●Propulsion converters - ●Auxiliary converters - ●Battery chargers. ## **Application Domain** - ●Railway (fixed installations and onboard). Notes: 1) For a d _i_ /d _t_ = 100 A/µs - 2) Additional information available on request. N° 97.A2.52.000.0 Page 1/3 LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com 16August2021/version 3 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice ## **Current Transducer LTC 600-SF** ## ~~**Insulation coordination**~~ _U_ d RMS voltage for AC insulation test, 50 Hz, 1 min 13.4[1)] kV 1.5[2)] kV _U_ t Partial discharge RMS test voltage ( _q_ m < 10 pC) > 2.8[3)] kV Min _d_ Cp Creepage distance 66.7 mm _d_ CI Clearance 45.9 mm _CTI_ Comparative tracking index (group I) 600 Notes:[1)] Between primary and secondary + shield - 2) Between secondary and shield - 3) Test carried out with a busbar ⌀ 40 mm centred in the through-hole. ## **Safety** This transducer must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 16August2021/version 3 ## **Dimensions LTC 600-SF** (in mm) **==> picture [510 x 364] intentionally omitted <==** **----- Start of picture text -----**<br> Connection<br>I P I S R M<br>d Cl d Cp U C<br>U C<br>d Cl d Cp<br>**----- End of picture text -----**<br> ## ~~**Mechanical characteristics**~~ - ●General tolerance ±1 mm - ●Transducer fastening 4 slots ⌀ 6.5 mm 4 M6 steel screws Recommended fastening torque 4.7 N·m - ●Primary through-hole ⌀ 42 mm ●Connection of secondary 4 M5 threaded studs Recommended fastening torque 2.2 N·m - Faston 6.3 × 0.8 mm ## **Remarks** - _I_ S is positi ~~ve~~ when _I_ P flow ~~s~~ in the direction of the arrow. - ●Temperature of the primary conductor should not exceed 100 °C. - ●Installation of the transducer must be done unless otherwise specified on the datasheet, according to LEM Transducer Generic Mounting Rules. Please refer to LEM document N°ANE120504 available on our Web site: **.** - **https://www.lem.com/en/file/3137/download/** - ●Dynamic performances ( d _i_ / d _t_ and delay time) are best with a single bar completely filling the primary hole. - ●This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. Page 3/3 16August2021/version 3 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →