LS200-5
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 200 W, 5 VDC, 40 A
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:200W; Output Voltage - Output 1:5V; Output Current - Output 1:40A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - Output
- SVHC: No SVHC (15-Jan-2018)
- Product Range: LS Series
- No. of Outputs: 1Outputs
- Output Power Max: 200W
- Current, Output 4: -
- Input Voltage VAC: 88V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 88V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 40A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 5VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 82.21 € |
| Current stock | 10+ |
| Lead time | 30 days |
LS200 Series https://product.tdk.com/en/power/ls www.emea.lambda.tdk.com/ls ## 150-200W Single Output General Purpose Power Supplies The LS series offers economically priced 150 to 200W power supplies for general purpose light industrial use. With output voltages ranging from 3.3 to 48V, the products have a five-year warranty[(1)] and conservatively rated electrolytic capacitor temperatures for longer field life. Two case styles are available - enclosed with internal fan, or a U-channel construction which can be operated either with external airflow or convection cooled at a lower power level. These compact products have a wide -25 to +70°C temperature range and are capable of withstanding a 300Vac surge for up to five seconds. |**Features**|**Benefits**| |---|---| |• Compact Package Sizes|• Space Saving in End Equipment| |• Low Cost|• Suitable for General Purpose Light Industrial Use| |• Withstands 300Vac Input Surges|• Can Operate on Unstable Input Voltages| |• Conservative Electrolytic Capacitor Temperatures|• Long Field Life| |• Five Year Warranty(1)|• Lower Cost of Ownership| ## **Model Selector** |||Adjustable|Max|Max|Peak|Load|Line|Ripple|Efficiency| |---|---|---|---|---|---|---|---|---|---| |Model|Voltage|Range|Current|Current Convection|Current|Reg|Reg|Noise|(typ)| ||(V)|(V)|(A)(2)|(A)(3)|(A)(4)|(mV)|(mV)|(mV)|%(5)| |LS200-3.3|3.3|3.0 - 3.6|40|N/A|-|40|16|80|67 / 68| |LS200-3.3/L|3.3|3.0 - 3.6|40|26|-|40|16|80|67 / 68| |LS200-5|5|4.75 - 5.5|40|N/A|-|40|20|80|72 / 75| |LS200-5/L|5|4.75 - 5.5|40|26|-|40|20|80|72 / 75| |LS200-7.5|7.5|6.8 - 8.2|26.7|N/A|-|40|20|80|74 / 77| |LS200-7.5/L|7.5|6.8 - 8.2|26.7|17.3|-|40|20|80|74 / 77| |LS200-12|12|10.8 - 14.4|16.7|N/A|-|96|48|120|76 / 79| |LS200-12/L|12|10.8 - 14.4|16.7|11.6|-|96|48|120|76 / 79| |LS200-15|15|13.5 - 16.5|13.4|N/A|-|120|60|120|80 / 83| |LS200-15/L|15|13.5 - 16.5|13.4|9.3|-|120|60|120|80 / 83| |LS200-24|24|22 - 28.8|8.4|N/A|10.4|192|96|120|82 / 84| |LS200-24/L|24|22 - 28.8|8.4|5.8|10.4|192|96|120|82 / 84| |LS200-36|36|32 - 40|5.6|N/A|6.9|288|144|150|82 / 85| |LS200-36/L|36|32 - 40|5.6|3.9|6.9|288|144|150|82 / 85| |LS200-48|48|42 - 57.6|4.2|N/A|-|384|192|200|82 / 85| |LS200-48/L|48|42 - 57.6|4.2|2.9|-|384|192|200|82 / 85| **LS200 -24 /L** 3.3 3.3V Output Voltage Blank Enclosed with internal fan 5 /L U-Channel without internal fan 3.3 3.3V Output Voltage 5 5V Output Voltage 7.5 7.5V Output Voltage 12 12V Output Voltage 15 15V Output Voltage 24 24V Output Voltage 36 36V Output Voltage 48 48V Output Voltage LS200 Series 1 **==> picture [517 x 34] intentionally omitted <==** |**Related Products**|**Related Products**|**Related Products**|**Related Products**|**Related Products**|**Related Products**| |---|---|---|---|---|---| ||Part Number|||Description|| |Lower power LS|LS25-150|||25W to 150W LS models|| |Higher power 7 year warranty|<br>RWSB|||50W to 1500W single output AC-DC power supplies|| ||||||| |**Specifcations**|||||| |Model<br>LS200 (Enclosed with fan)<br>LS200/L (U-Channel, no fan)|||||| |**Input**|||||| |AC Input Voltage Range (Operating)||Vac|85 - 264<br>||85 - 264(6)<br>| |Nominal Input Voltage Range||Vac|100 - 240 (Note: Safety certifed for 90-264Vac only)||| |Input Surge Voltage||Vac|300 for up to 5s<br>||| |Input Frequency||Hz|47 - 63 (Note: Safety certifed for 50/60Hz only)<br>||| |DC Input Voltage range||Vdc|120 - 373 (Note: Safety certifed for AC input only)||| |Input Current (115 / 230Vac)||A|3.5 / 1.7 (typical)||| |Inrush Current at 230Vac (Cold Start)||A|60||| |Leakage Current (230Vac 60Hz)||mA|<1||| |Harmonic Compliance||-|IEC61000-3-2, -3||| |Hold Up Time (115 / 230Vac Input)<br>||ms|20||| |Effciency||-|See Model Selector Table||| |Conducted & Radiated EMI||-|EN55011/EN55032-B, FCC-B||| |Immunity||-|See Immunity Table||| |Insulation Class<br>||-|Class I||| |Safety Certifcations and Markings||-|IEC/EN/UL/CSA62368-1, 60950-1, CE Mark and UKCA Mark||| ## **Immunity** |**Immunity**|**Immunity**|**Immunity**|**Immunity**|**Immunity**| |---|---|---|---|---| |Test<br>Standard<br>Test Level<br>Criteria<br>Notes||||| |ESD|EN61000-4-2|± 8kV air discharge<br>± 6kV contact discharge|A|See immunity report on website for more details| |Radiated Susceptibility|EN61000-4-3|10V/m from 80-1000 MHz|A|| |Electrical Fast Transient Burst|EN61000-4-4|± 2kV|A|| |Surge|EN61000-4-5|± 4kV common mode<br>± 2kV differential mode|A|| |Conducted Susceptibility|EN61000-4-6|10Vrms, 150kHz - 80 MHz|A|| |Magnetic Fields|EN61000-4-8|30A/m|A|| |Voltage Dips|EN61000-4-11<br>(230Vac)|30% dip for 10ms<br>60% dip for 100ms<br>100% 5000ms|A<br>B<br>B|| LS200 Series 2 **==> picture [516 x 34] intentionally omitted <==** ## **Specifications** |**Specifcations**|**Specifcations**|**Specifcations**|**Specifcations**| |---|---|---|---| |Model<br>LS200 (Enclosed with fan)<br>LS200/L (U-Channel, no fan)|||| |**Output**|||| |Output Voltage Adjustment||See model selector|| |Switching Frequency|kHz|130|| |Line Regulation|-|See model selector|| |Load Regulation|-|See model selector|| |External Load Capacitance|-|See instruction manual|| |Ripple & Noise<br>|-|See model selector|| |Temperature Coeffcient|%/°C|<0.02 (0 - 50°C)|| |Minimum Load|-|No minimum load required|| |Overcurrent Protection(7)|%|105 of maximum output current for 3.3V - 15V & 48V and 105 of peak output current for 24V - 36V|| |Overvoltage Protection(8)|V|3.3V: 3.8 - 4.45, 5V: 5.75 - 6.75, 7.5V: 8.6 - 10.1, 12V: 15.1 - 17.75, 15V: 17.25 - 20.25,<br>24V: 30.25 - 35.5, 36V: 41.4 - 48.6, 48V: 60 - 72.5|| |Overtemperature Protection(8)|-|Yes|| |Remote Sense|-|No|| |Remote On/Off|-|CN2: 3 - 12VDC POWER OFF, < 0 - 0.8VDC POWER ON|| |Indicators|-|Green LED indicates DC is OK|| |Parallel Operation|-|Not possible|| |**Environmental**|||| |Operating Temperature (-25°C start-up)|°C|-25 to +70 (see installation manual for derating curves)|| |Storage Temperature|°C|-40° to +85|| |Humidity (non condensing)|%RH|Operating: 20 - 90, Storage: 10 - 95|| |Cooling|-|Fan cooled (exhaust from fan end)|Convection| |Altitude|m|2,000|| |Withstand Voltage (For 1 minute)|Vac|Input to Ground 1,500, Input to Output 3,000, Output to Ground 500 for 1 min.|| |Isolation Resistance|MΩ|>100 at 25°C, 70%RH & 500VDC|| |Vibration (Non operating)|-|10 - 55Hz: 19.6m/s2constant sweep 1 min X, Y, Z for 1 hour|| |Shock|-|< 196.1 m/s2(20G)|| |**Other**|||| |Weight (Typ)|g|700|600| |Size (LxWxH)|mm|199 x 98 x 41|| |Size (LxWxH)|Inches|<br>7.8 x 3.9 x 1.61|| |Connectors||Screw terminals|| |Case Material|-|Metal|| |MTBF - MIL-HDBK-217F|Hrs|300,000|| |Warranty(1)|Yrs|5|| Notes: See website for detailed specifications, test methods and installation manual (1) The Americas and EMEA regions: 5 years. Other regions: 3 years. See applicable regional terms of sale. (2) With internal fan version LS200-xx or LS200-xx/L version with external airflow (3) Max current at nominal output voltage; see installation manual for derating curve (4) Operating period at peak output current is <10s at <35% duty cycle (5) 115 / 230Vac input (6) Derate linearly to 65% load from 115Vac to 85Vac (7) Constant current limiting with automatic recovery. Avoid to operate at overload and dead short for more than 30 seconds (8) OVP, OTP circuit will shutdown output, manual reset (Re-power on) LS200 Series 3 ## **Outline Drawing LS200 (Enclosed with fan)** ## **Outline Drawing LS200/L (U-Channel, no fan)** LS200 Series 4 ## **TDK-Lambda France SAS** Tel: +33 1 60 12 71 65 tlf.fr.powersolutions@tdk.com www.emea.lambda.tdk.com/fr **TDK-Lambda Americas** Tel: +1 800-LAMBDA-4 or 1-800-526-2324 tla.powersolutions@tdk.com www.us.lambda.tdk.com ## **Italy Sales Office** Tel: +39 02 61 29 38 63 tlf.it.powersolutions@tdk.com www.emea.lambda.tdk.com/it ## **Netherlands** ## **TDK Electronics do Brasil Ltda** Tel: +55 11 3289-9599 sales.br@tdk-electronics.tdk.com www.tdk-electronics.tdk.com/en tlf.nl.powersolutions@tdk.com www.emea.lambda.tdk.com/nl ## **TDK-Lambda Germany GmbH** Tel: +49 7841 666 0 tlg.powersolutions@tdk.com www.emea.lambda.tdk.com/de ## **TDK-Lambda Corporation** Tel: +81-3-6778-1113 www.jp.lambda.tdk.com ## **TDK-Lambda (China) Electronics Co. Ltd.** Tel: +86 21 6485-0777 tlc.powersolutions@tdk.com www.lambda.tdk.com.cn ## **Austria Sales Office** Tel: +43 2256 655 84 tlg.at.powersolutions@tdk.com www.emea.lambda.tdk.com/at ## **Switzerland Sales Office** Tel: +41 44 850 53 53 tlg.ch.powersolutions@tdk.com www.emea.lambda.tdk.com/ch ## **Nordic Sales Office** **TDK-Lambda Singapore Pte Ltd.** Tel: +65 6251 7211 tls.marketing@tdk.com www.sg.lambda.tdk.com **TDK India Private Limited, Power Supply Division** Tel: +91 80 4039-0660 mathew.philip@tdk.com www.sg.lambda.tdk.com Tel: +45 8853 8086 tlg.dk.powersolutions@tdk.com www.emea.lambda.tdk.com/dk ## **TDK-Lambda UK Ltd.** Tel: +44 (0) 12 71 85 66 66 tlu.powersolutions@tdk.com www.emea.lambda.tdk.com/uk ## **TDK-Lambda Ltd.** Tel: +9 723 902 4333 tli.powersolutions@tdk.com www.emea.lambda.tdk.com/il-en For Additional Information, please visit ~~a~~ https://product.tdk.com/en/power/ LS200_260865 March 6th, 2023 V2 LS200 Series 5
Updated at June 4, 2026
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →