Image not available
Illustrative purposes only
LRTM/2 12-230V AC/DC
Analogue Timer, LRTM/2, Multifunction, 0.1 s, 100 h, 7 Ranges, 2 Changeover Relays
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: BROYCE CONTROL
- Product type: Analogue Timers - DIN Rail
- Product Range:LRTM/2 Series; Timer Functions:Multifunction; Time Min:0.1s; Time Max:100h; No. of Timing Ranges:7Ranges; Timer Output:2 Changeover Relays; Supply Voltage Max:230V; Current
- SVHC: No SVHC (04-Feb-2026)
- Time Max: 100h
- Time Min: 0.1s
- Timer Output: 2 Changeover Relays
- Product Range: LRTM/2
- Timer Functions: Multifunction
- Current Rating Nom: 8A
- Supply Voltage Max: 230V
- No. of Timing Ranges: 7Ranges
- Connection / Termination: Screw Terminals
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 42.94 € |
| Current stock | 10+ |
| Lead time | 30 days |
## _**Type: LRTM/2**_ **Asymmetrical Recycling / Delayed Pulse Timer**
**==> picture [262 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
Terminal Protection ———s Q *NEW* 17.5mm DIN rail housing<br>to IP20 Q Microprocessor based<br>**----- End of picture text -----**<br>
**Dual Function - Asymmetrical recycling “Off/On” AF or Delayed Pulse DP Separate adjustments for “on” and “off” ranges**
**7 Selectable time ranges (0.1 seconds – 100 hours)**
**==> picture [88 x 66] intentionally omitted <==**
**----- Start of picture text -----**<br>
“é!<br>ost,<br>ar=cd<br>Dims: to DIN 43880 LRTW/2<br>W. 17.5mm<br>**----- End of picture text -----**<br>
**Fine adjustment of selected time range Multi-voltage input (12 – 230V AC/DC) DPDT relay output 8A Green LED indication for supply / timing status Red LED indication for relay status Conforms to IEC 61812**
**==> picture [540 x 355] intentionally omitted <==**
**----- Start of picture text -----**<br>
• FUNCTION DIAGRAMS • TECHNICAL SPECIFICATION<br>Asymmetrical Recycling Off / On (AF) Supply voltage U (A1, A2) : 12 – 230V AC/DC<br>yaSuppl afe, !] Frequency range: Supply variation: AC: +15/-10% DC: +/-15% 48 - 63Hz (AC supplies)<br>Overvoltage category: III (IEC 60664)<br>Link | Rated impulse withstand voltage: 4kV (1.2/50µS) IEC 60664<br>ALBIoQo | Power consumption (max.): 12V 24V 110V 230V<br>Output . m AC: 0.6VA 0.8VA 2.6VA 6.8VA<br>RLY Ho & OF @ OO DC: 0.52W 0.48W 0.94W 1.9W<br>18 (28 Timing function: Asymmetrical Recycling “Off / On” or<br>1525-0.” a ee |__| Delayed Pulse (A1 > B1 linked)<br>Timing ranges (7): Seconds: Minutes: Hours:<br>(applies to “tON” and “tOFF”) 0.1 – 1 0.1 – 1 0.1 – 1<br>Delayed Pulse (DP) 1 – 10 1 – 10 10 - 100 1 – 10<br>(terminals A1 and B1 linked)<br>Suppl E We Reset time [2] : <100mS<br>ae Accuracy: ± 1% of maximum full scale<br>Adjustment accuracy: < 5% of maximum full scale<br> a ul a tO Repeat accuracy: ± 0.5% at constant conditions (IEC 61812)<br>anBio’ Drift with temperature: ± 0.05% / °C<br>Outputoo 18.28ooo #1 a4 Power on indication / TimingAmbient temp: Relay status: [1] : Green LED -20 to +60Red LED °C<br>15 (25-0 TT{st Relative humidity: +95%<br>Output (15, 16, 18 / 25, 26, 28) : DPDT relay<br>vl, Output rating: AC1 250V 8A (2000VA)<br>AC15 250V 3A<br>LED operation: fi LED Off hk -™ LED On & a. LED Flashing DC1 25V 8A (200W)<br>Electrical life: ≥ 150,000 ops at rated load<br>• INSTALLATION AND SETTING Installation work must be carried Dielectric voltage: Rated impulse withstand voltage: 4kV (1.2/502kV AC (rms) IEC 60947-1 µS) IEC 60664<br>• BEFORE INSTALLATION, ISOLATE THE SUPPLY. out by qualified personnel. Housing: Orange flame retardant UL94<br>• Connect the unit as required. Weight: ≈ 80g<br>• If the Delayed Pulse function is required, place a link between terminals A1 and B1. Mounting option: On to 35mm symmetric DIN rail to BS EN 60715<br>or direct surface mounting via 2 x M3.5 or 4BA screws<br>Setting the unit. using the black clips provided on the rear of the unit.<br>• Set the “tOFF” ➍ and “tON” ➏ “Range” selectors to the required position (depending on whether Terminal conductor size ≤ 2 x 2.5mm [2] solid or stranded<br>seconds, minutes or hours are required). Approvals: Conforms to IEC 61812.<br>• Set the “Set %” adjustment for the “tOFF” ➌ and “tON” ➎ as required. The “Set %” is a % of the<br>selected range, so 60% of the 1 – 10 hour range will give 6 hours. Gy)ustes IND. CONT.E111187 EQ.<br>Applying power. CE, C-tick Cc and RoHS Compliant.<br>• Apply power and the green LED ➊➊ will start flashing to indicate timing is in progress. EMC: Immunity: EN 61000-6-2 (EN 61000-4-3 10V/m<br>• The red relay LED ➋ will illuminate to indicate the relay is the energised state when the “tON” ➋ will illuminate to indicate the relay is the energised state when the “tON” will illuminate to indicate the relay is the energised state when the “tON” ON” ” 80MHz - 2.7GHz)<br>Emissions: EN 61000-6-4<br>**----- End of picture text -----**<br>
- Apply power and the green LED ➊➊ will start flashing to indicate timing is in progress.
- • The red relay LED ➋ will illuminate to indicate the relay is the energised state when the “tON” ➋ will illuminate to indicate the relay is the energised state when the “tON” will illuminate to indicate the relay is the energised state when the “tON” ON” ” delay is running.
- When the “tOFF” delay is running and relay is de-energised, the red LED will remain extinguished.
- • If the Delayed Pulse function is selected, the green LED will stop flashing and remain illuminated when the relay de-energises after the “tON” period.
_Note:_
- _1 In accordance with IEC 61812, the green LED is permitted to extinguish during a voltage dip or momentary interruption of the power supply providing the state of the output relay does not change._
- _2 The dip / interruption (reset) duration and levels are defined in the product standard however, the standard allows for these to be different from the levels actually specified._
**==> picture [98 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
• CONNECTION DIAGRAM<br>**----- End of picture text -----**<br>
**==> picture [501 x 133] intentionally omitted <==**
**----- Start of picture text -----**<br>
• SETTING DETAILS • DIMENSIONS<br>N/-ve 1. Power supply status / SSPROVGE 89 (exc. clips)<br>SupplyL/+ve A1 A2B1 i Link terminals A1and B1 for DelayedPulse Timing (Green) LED 2. Relay output status (Red) LED 3. “tOFF” delay “Set %” ➊ 100 90 ➎ ' H 67.545 ' H<br>_ adjustment ou, pit | | |<br>4. “tOFF” delay “Range”<br>15 selector ➏ aaciea rt Insert screwdriver !<br>(25) 5. “tON” delay “Set %” 0.1-1.1-10) \ to release clips : H<br>R adjustment<br>16 ) 7 18 6. “tON” delay “Range” ➍ 01-1440 & ' !<br>(26) (28) selector to-0010 age0°" t ➌ Withdraw clips<br>15 16 18 fully when<br>➋ oOR a surface mounting<br>25 26 28 rai ——— 92 (+/- 1mm) — all dimensions in mm.<br>66.5<br>49.5<br>29<br>**----- End of picture text -----**<br>
Broyce Control Ltd., Pool Street, Wolverhampton, West Midlands WV2 4HN. England Tel: +44 (0) 1902 773746 Fax: +44 (0) 1902 420639 Email: sales@broycecontrol.com Web: www.broycecontrol.com
_The Information provided in this literature is believed to be accurate (subject to change without prior notice); however, use of such information shall be entirely at the user’s own risk._
LRTM_2-2-A.DOCX 1811
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →