LRS-50-12
AC/DC Enclosed Power Supply (PSU), ITE & Household, 1 Outputs, 50.4 W, 12 VDC, 4.2 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:50.4W; Output Voltage - Output 1:12V; Output Current - Output 1:4.2A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - O
- SVHC: No SVHC (25-Jun-2025)
- Product Range: LRS-50 Series
- No. of Outputs: 1Outputs
- Output Power Max: 50.4W
- Input Voltage VAC: 85V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 85V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 4.2A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Household
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 11.61 € |
| Current stock | 200+ |
| Lead time | 30 days |
**LRS - 50 series** 50W Single Output Switching Power Supply **==> picture [276 x 53] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>S AS/NZS60950-1 GB4943.1 @ UL62368-1 B y EN623680-1 www.ID 2000000000tuv.com TP TC004 IEC62368-1<br>C & © Wa s tiICBCE<br>■ <br>**----- End of picture text -----**<br> - ‧ - ‧ - ‧ - ‧ - ‧℃ - ‧ ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - - ‧ - ‧ - ‧ - ‧ - ‧Ⅲ - ‧ - ‧ ## ■ **** ℃℃ ## ■ **** ** ** [] **** _File Name:LRS-50-SPEC 2019-07-23_ 50W Single Output Switching Power Supply ## **LRS - 50 series** ## **SPECIFICATION** |**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION Note.4**<br>**LOAD REGULATIONNote.5**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>****<br>**PACKING**<br>**OVER LOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1000ms, 30ms/230VAC 2000ms,30ms/115VAC at full load<br>30ms/230VAC 12ms/115VAC at full load<br>85 ~ 264VAC 120 ~ 373VDC<br>47 ~ 63Hz<br>80%<br>86%<br>88%<br>88%<br>90%<br>0.95A/115VAC 0.56A/230VAC<br>COLD START 45A/230VAC<br><0.75mA / 240VAC<br>110 ~ 150% rated output power<br>I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>-30 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 90% RH non-condensing<br>-40 ~ +85℃, 10 ~ 95% RH non-condensing<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>645K hrs min. MIL-HDBK-217F (25℃)<br>0.23Kg; 60pcs/14.8Kg/0.88CUFT<br>99*82*30mm (L*W*H)<br>3.3V<br>12V<br>15V<br>24V<br>48V<br>10A<br>4.2A<br>3.4A<br>2.2A<br>1.1A<br>0 ~ 10A<br>0 ~ 4.2A<br>0 ~ 3.4A<br>0 ~ 2.2A<br>0 ~ 1.1A<br>33W<br>50.4W<br>51W<br>52.8W<br>52.8W<br>80mVp-p<br>120mVp-p<br>120mVp-p<br>150mVp-p<br>200mVp-p<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±2.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**PROTECTION**<br>**ENVIRONMENT**<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>89%<br>36V<br>1.45A<br>0 ~ 1.45A<br>52.2W<br>200mVp-p<br>±1.0%<br>±0.5%<br>±0.5%<br>5V<br>10A<br>0 ~ 10A<br>50W<br>80mVp-p<br>±2.0%<br>±0.5%<br>±1.0%<br>83%<br>**SAFETY STANDARDS**<br>Protection type : Shut down o/p voltage, re-power on to recover<br>3.8 ~ 4.45V<br>5.9~ 7.3V<br>13.8 ~ 16.2V<br>18.75 ~ 21.75V 28.8 ~ 33.6V<br>41.4 ~ 48.6V<br>55.2 ~ 64.8V<br>±3.0%<br>Compliance to EN55032 (CISPR32) Class B, EN55014, EN61000-3-2,-3, GB/T 9254, BSMI CNS13438, EAC TP TC 020<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020<br>**SAFETY &**<br>**EMC**<br>**(Note 9)**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>2.97 ~ 3.6V<br>10.2 ~ 13.8V<br>13.5 ~ 18V<br>21.6 ~ 28.8V<br>43.2 ~ 52.8V<br>32.4 ~ 39.6V<br>4.5 ~ 5.5V<br>**LRS-50-3.3**<br>**LRS-50-5**<br>**LRS-50-12**<br>**LRS-50-15**<br>**LRS-50-24**<br>**LRS-50-36**<br>**LRS-50-48**<br>UL62368-1, TUV EN62368-1, EN60335-1, EN61558-1/-2-16,CCC GB4943.1, BSMI CNS14336-1,<br>℃<br><br><br><br><br><br><br><br><br>℃<br><br><br><br><br>**OVER VOLTAGE CATEGORY**<br>Ⅲ; Compliance to EN61558, EN50178, EN60664-1, EN62477-1; altitude up to 2000 meters<br>EAC TP TC 004, AS/NZS 60950.1(by CB) approved|**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION Note.4**<br>**LOAD REGULATIONNote.5**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>****<br>**PACKING**<br>**OVER LOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1000ms, 30ms/230VAC 2000ms,30ms/115VAC at full load<br>30ms/230VAC 12ms/115VAC at full load<br>85 ~ 264VAC 120 ~ 373VDC<br>47 ~ 63Hz<br>80%<br>86%<br>88%<br>88%<br>90%<br>0.95A/115VAC 0.56A/230VAC<br>COLD START 45A/230VAC<br><0.75mA / 240VAC<br>110 ~ 150% rated output power<br>I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>-30 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 90% RH non-condensing<br>-40 ~ +85℃, 10 ~ 95% RH non-condensing<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>645K hrs min. MIL-HDBK-217F (25℃)<br>0.23Kg; 60pcs/14.8Kg/0.88CUFT<br>99*82*30mm (L*W*H)<br>3.3V<br>12V<br>15V<br>24V<br>48V<br>10A<br>4.2A<br>3.4A<br>2.2A<br>1.1A<br>0 ~ 10A<br>0 ~ 4.2A<br>0 ~ 3.4A<br>0 ~ 2.2A<br>0 ~ 1.1A<br>33W<br>50.4W<br>51W<br>52.8W<br>52.8W<br>80mVp-p<br>120mVp-p<br>120mVp-p<br>150mVp-p<br>200mVp-p<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±2.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**PROTECTION**<br>**ENVIRONMENT**<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>89%<br>36V<br>1.45A<br>0 ~ 1.45A<br>52.2W<br>200mVp-p<br>±1.0%<br>±0.5%<br>±0.5%<br>5V<br>10A<br>0 ~ 10A<br>50W<br>80mVp-p<br>±2.0%<br>±0.5%<br>±1.0%<br>83%<br>**SAFETY STANDARDS**<br>Protection type : Shut down o/p voltage, re-power on to recover<br>3.8 ~ 4.45V<br>5.9~ 7.3V<br>13.8 ~ 16.2V<br>18.75 ~ 21.75V 28.8 ~ 33.6V<br>41.4 ~ 48.6V<br>55.2 ~ 64.8V<br>±3.0%<br>Compliance to EN55032 (CISPR32) Class B, EN55014, EN61000-3-2,-3, GB/T 9254, BSMI CNS13438, EAC TP TC 020<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020<br>**SAFETY &**<br>**EMC**<br>**(Note 9)**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>2.97 ~ 3.6V<br>10.2 ~ 13.8V<br>13.5 ~ 18V<br>21.6 ~ 28.8V<br>43.2 ~ 52.8V<br>32.4 ~ 39.6V<br>4.5 ~ 5.5V<br>**LRS-50-3.3**<br>**LRS-50-5**<br>**LRS-50-12**<br>**LRS-50-15**<br>**LRS-50-24**<br>**LRS-50-36**<br>**LRS-50-48**<br>UL62368-1, TUV EN62368-1, EN60335-1, EN61558-1/-2-16,CCC GB4943.1, BSMI CNS14336-1,<br>℃<br><br><br><br><br><br><br><br><br>℃<br><br><br><br><br>**OVER VOLTAGE CATEGORY**<br>Ⅲ; Compliance to EN61558, EN50178, EN60664-1, EN62477-1; altitude up to 2000 meters<br>EAC TP TC 004, AS/NZS 60950.1(by CB) approved|**LRS-50-3.3**|**LRS-50-5**|**LRS-50-12**|**LRS-50-15**|**LRS-50-24**|**LRS-50-36**|**LRS-50-48**| |---|---|---|---|---|---|---|---|---| ||**DC VOLTAGE**|3.3V|5V|12V|15V|24V|36V|48V| ||**RATED CURRENT**|10A|10A|4.2A|3.4A|2.2A|1.45A|1.1A| ||**CURRENT RANGE**|0 ~ 10A|0 ~ 10A|0 ~ 4.2A|0 ~ 3.4A|0 ~ 2.2A|0 ~ 1.45A|0 ~ 1.1A| ||**RATED POWER**|33W|50W|50.4W|51W|52.8W|52.2W|52.8W| ||**RIPPLE & NOISE (max.)Note.2**|80mVp-p|80mVp-p|120mVp-p|120mVp-p|150mVp-p|200mVp-p|200mVp-p| ||**VOLTAGE ADJ. RANGE**|2.97 ~ 3.6V|4.5 ~ 5.5V|10.2 ~ 13.8V|13.5 ~ 18V|21.6 ~ 28.8V|32.4 ~ 39.6V|43.2 ~ 52.8V| ||**VOLTAGE TOLERANCENote.3**|±3.0%|±2.0%|±1.0%|±1.0%|±1.0%|±1.0%|±1.0%| ||**LINE REGULATION Note.4**|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%| ||**LOAD REGULATIONNote.5**|±2.0%|±1.0%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%| ||**SETUP, RISE TIME**|1000ms, 30ms/230VAC 2000ms,30ms/115VAC at full load||||||| ||**HOLD UP TIME (Typ.)**|30ms/230VAC 12ms/115VAC at full load||||||| ||**VOLTAGE RANGE**|85 ~ 264VAC 120 ~ 373VDC||||||| ||**FREQUENCY RANGE**|47 ~ 63Hz||||||| ||**EFFICIENCY (Typ.)**|80%|83%|86%|88%|88%|89%|90%| ||**AC CURRENT (Typ.)**|0.95A/115VAC 0.56A/230VAC||||||| ||**INRUSH CURRENT (Typ.)**|COLD START 45A/230VAC||||||| ||**LEAKAGE CURRENT**|<0.75mA / 240VAC||||||| ||**OVER LOAD**|110 ~ 150% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed||||||| ||**OVER VOLTAGE**|Protection type : Shut down o/p voltage, re-power on to recover<br>3.8 ~ 4.45V<br>5.9~ 7.3V<br>13.8 ~ 16.2V<br>18.75 ~ 21.75V 28.8 ~ 33.6V<br>41.4 ~ 48.6V<br>55.2 ~ 64.8V||||||| ||**WORKING TEMP.**|-30 ~ +70℃(Refer to "Derating Curve")||||||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing||||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85℃, 10 ~ 95% RH non-condensing||||||| ||**TEMP. COEFFICIENT**|±0.03%/℃(0 ~ 50℃)||||||| ||**VIBRATION**|10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes||||||| ||**OVER VOLTAGE CATEGORY**|Ⅲ; Compliance to EN61558, EN50178, EN60664-1, EN62477-1; altitude up to 2000 meters||||||| ||**SAFETY STANDARDS**|UL62368-1, TUV EN62368-1, EN60335-1, EN61558-1/-2-16,CCC GB4943.1, BSMI CNS14336-1,<br>EAC TP TC 004, AS/NZS 60950.1(by CB) approved||||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC||||||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH||||||| ||**EMC EMISSION**|Compliance to EN55032 (CISPR32) Class B, EN55014, EN61000-3-2,-3, GB/T 9254, BSMI CNS13438, EAC TP TC 020||||||| ||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020||||||| ||**MTBF**|645K hrs min. MIL-HDBK-217F (25℃)||||||| ||**DIMENSION**|99*82*30mm (L*W*H)||||||| ||**PACKING**|0.23Kg; 60pcs/14.8Kg/0.88CUFT||||||| _File Name:LRS-50-SPEC 2019-07-23_ **LRS - 50 series** ## 50W Single Output Switching Power Supply **==> picture [483 x 314] intentionally omitted <==** **----- Start of picture text -----**<br> Block Diagram<br>fosc : 115Vac : 75KHz<br> 230Vac :110KHz<br>EMI RECTIFIERS POWER RECTIFIERS +V<br>I/P FILTER & SWITCHING & -V<br>FILTER FILTER<br>O.V.P.<br>FG<br>DETECTION<br>O.L.P. CONTROL<br>CIRCUIT<br>Derating Curve Static Characteristics<br>230VAC 100<br>100<br>90<br>75<br>80<br>100VAC 100VAC<br>60 Input only for 5V 70<br>60<br>40<br>50<br>20<br>40<br>-30 -25 0 10 20 30 40 50 60 70 (HORIZONTAL) 85 95 100 115 120 140 160 180 200 220 240 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:LRS-50-SPEC 2019-07-23_ **LRS - 50 series** 50W Single Output Switching Power Supply ## **Mechanical Specification** **==> picture [222 x 291] intentionally omitted <==** **----- Start of picture text -----**<br> 4.5 92.5<br>1<br>2<br>3<br>4<br>5<br>20.5 55<br>99<br>6.5 90<br>10 74<br>3.5<br>ψ<br>2-M3 L=3.0<br>ψ<br>3.5<br>2-M3 L=5<br>9.5<br>70 82<br>8<br>40.5<br>3.5<br>6.5<br>30<br>26<br>15 3.5 14.5<br>**----- End of picture text -----**<br> **==> picture [85 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Case No.239A Unit:mm<br>**----- End of picture text -----**<br> **==> picture [160 x 50] intentionally omitted <==** **----- Start of picture text -----**<br> Terminal Pin No. Assignment<br>Pin No. Assignment Pin No. Assignment<br>1 AC/L 4 DC OUTPUT -V<br>2 AC/N 5 DC OUTPUT +V<br>3 FG<br>**----- End of picture text -----**<br> ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:LRS-50-SPEC 2019-07-23_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →