Image not available
Illustrative purposes only
LRS-150-15
AC/DC Enclosed Power Supply (PSU), ITE & Household, 1 Outputs, 150 W, 15 VDC, 10 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:150W; Output Voltage - Output 1:15V; Output Current - Output 1:10A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - Outp
- SVHC: No SVHC (25-Jun-2025)
- Product Range: LRS-150 Series
- No. of Outputs: 1Outputs
- Output Power Max: 150W
- Input Voltage VAC: 85V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 85V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 10A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 15VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Household
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 13.71 € |
| Current stock | 50+ |
| Lead time | 30 days |
**LRS - 150 series** 150W Single Output Switching Power Supply ## ■ **==> picture [190 x 43] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>www.ID 2000000000tuv.com<br>@ CAL 4 /CBCE<br>■<br>**----- End of picture text -----**<br> ℃ ## ■ ℃ ℃ ## ■ _File Name:LRS-150-SPEC 2016-05-11_ **LRS - 150 series** ## 150W Single Output Switching Power Supply ## **SPECIFICATION** |**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION Note.4**<br>**LOAD REGULATION Note.5**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER LOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>500ms, 30ms/230VAC 500ms,30ms/115VAC at full load<br>40ms/230VAC 35ms/115VAC at full load<br>85 ~ 132VAC / 170 ~ 264VAC by switch 240 ~ 370VDC(switch on 230VAC)<br>47 ~ 63Hz<br>2.8A/115VAC 1.6A/230VAC<br>COLD STAR 60A/230VAC<br><0.75mA / 240VAC<br>110 ~ 140% rated output power<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>-30 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>601K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>0.48Kg ; 30pcs/15.4Kg/0.75CUFT<br>159*97*30mm (L*W*H)<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**PROTECTION**<br>**ENVIRONMENT**<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>**SAFETY STANDARDS**<br>UL60950-1, TUV EN60950-1, EN60335-1, EN61558-1<br>,CCC GB4943 approved<br>/- -<br>2 16<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, re-power on to recover<br>Compliance to EN55022 (CISPR22), GB9254 Class B, EN55014, EN61000-3-2Class A(<br>75% Load),EN61000-3-3<br>≤<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A<br>**SAFETY &**<br>**EMC**<br>**(Note 7)**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**OVER TEMPERATURE**<br>87.5%<br>88.5%<br>89%<br>90%<br>12V<br>15V<br>24V<br>48V<br>12.5A<br>10A<br>6.5A<br>3.3A<br>0 ~ 12.5A<br>0 ~ 10A<br>0 ~ 6.5A<br>0 ~ 3.3A<br>150W<br>150W<br>156W<br>158.4W<br>150mVp-p<br>150mVp-p<br>200mVp-p<br>200mVp-p<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>89%<br>36V<br>4.3A<br>0 ~ 4.3A<br>154.8W<br>200mVp-p<br>±1.0%<br>±0.5%<br>±0.5%<br>13.8 ~ 16.2V<br>18.75 ~ 21.75V<br>28.8 ~ 33.6V<br>41.4 ~ 48.6V<br>55.2 ~ 64.8V<br>10.2 ~ 13.8V<br>13.5 ~ 18V<br>21.6 ~ 28.8V<br>43.2 ~ 52.8V<br>32.4 ~ 39.6V<br>**LRS-150-12**<br>**LRS-150-15**<br>**LRS-150-24**<br>**LRS-150-36**<br>**LRS-150-48**<br>℃<br>℃<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. Line regulation is measured from low line to high line at rated load.<br>5. Load regulation is measured from 0% to 100% rated load.<br>6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up<br>time.<br>7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by<br>mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Awww.meanwell.com)<br>8. The ambient temperature derating of<br>5<br>/1000m is needed for operating altitude greater than 2000m (6500ft).|**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION Note.4**<br>**LOAD REGULATION Note.5**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER LOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>500ms, 30ms/230VAC 500ms,30ms/115VAC at full load<br>40ms/230VAC 35ms/115VAC at full load<br>85 ~ 132VAC / 170 ~ 264VAC by switch 240 ~ 370VDC(switch on 230VAC)<br>47 ~ 63Hz<br>2.8A/115VAC 1.6A/230VAC<br>COLD STAR 60A/230VAC<br><0.75mA / 240VAC<br>110 ~ 140% rated output power<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>-30 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes<br>601K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>0.48Kg ; 30pcs/15.4Kg/0.75CUFT<br>159*97*30mm (L*W*H)<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**PROTECTION**<br>**ENVIRONMENT**<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>**SAFETY STANDARDS**<br>UL60950-1, TUV EN60950-1, EN60335-1, EN61558-1<br>,CCC GB4943 approved<br>/- -<br>2 16<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, re-power on to recover<br>Compliance to EN55022 (CISPR22), GB9254 Class B, EN55014, EN61000-3-2Class A(<br>75% Load),EN61000-3-3<br>≤<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A<br>**SAFETY &**<br>**EMC**<br>**(Note 7)**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**OVER TEMPERATURE**<br>87.5%<br>88.5%<br>89%<br>90%<br>12V<br>15V<br>24V<br>48V<br>12.5A<br>10A<br>6.5A<br>3.3A<br>0 ~ 12.5A<br>0 ~ 10A<br>0 ~ 6.5A<br>0 ~ 3.3A<br>150W<br>150W<br>156W<br>158.4W<br>150mVp-p<br>150mVp-p<br>200mVp-p<br>200mVp-p<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>89%<br>36V<br>4.3A<br>0 ~ 4.3A<br>154.8W<br>200mVp-p<br>±1.0%<br>±0.5%<br>±0.5%<br>13.8 ~ 16.2V<br>18.75 ~ 21.75V<br>28.8 ~ 33.6V<br>41.4 ~ 48.6V<br>55.2 ~ 64.8V<br>10.2 ~ 13.8V<br>13.5 ~ 18V<br>21.6 ~ 28.8V<br>43.2 ~ 52.8V<br>32.4 ~ 39.6V<br>**LRS-150-12**<br>**LRS-150-15**<br>**LRS-150-24**<br>**LRS-150-36**<br>**LRS-150-48**<br>℃<br>℃<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. Line regulation is measured from low line to high line at rated load.<br>5. Load regulation is measured from 0% to 100% rated load.<br>6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up<br>time.<br>7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by<br>mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Awww.meanwell.com)<br>8. The ambient temperature derating of<br>5<br>/1000m is needed for operating altitude greater than 2000m (6500ft).|**LRS-150-12**|**LRS-150-15**|**LRS-150-24**|**LRS-150-36**|**LRS-150-48**| |---|---|---|---|---|---|---| ||**DC VOLTAGE**|12V|15V|24V|36V|48V| ||**RATED CURRENT**|12.5A|10A|6.5A|4.3A|3.3A| ||**CURRENT RANGE**|0 ~ 12.5A|0 ~ 10A|0 ~ 6.5A|0 ~ 4.3A|0 ~ 3.3A| ||**RATED POWER**|150W|150W|156W|154.8W|158.4W| ||**RIPPLE & NOISE (max.) Note.2**|150mVp-p|150mVp-p|200mVp-p|200mVp-p|200mVp-p| ||**VOLTAGE ADJ. RANGE**|10.2 ~ 13.8V|13.5 ~ 18V|21.6 ~ 28.8V|32.4 ~ 39.6V|43.2 ~ 52.8V| ||**VOLTAGE TOLERANCE Note.3**|±1.0%|±1.0%|±1.0%|±1.0%|±1.0%| ||**LINE REGULATION Note.4**|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%| ||**LOAD REGULATION Note.5**|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%| ||**SETUP, RISE TIME**|500ms, 30ms/230VAC 500ms,30ms/115VAC at full load||||| ||**HOLD UP TIME (Typ.)**|40ms/230VAC 35ms/115VAC at full load||||| ||**VOLTAGE RANGE**|85 ~ 132VAC / 170 ~ 264VAC by switch 240 ~ 370VDC(switch on 230VAC)||||| ||**FREQUENCY RANGE**|47 ~ 63Hz||||| ||**EFFICIENCY (Typ.)**|87.5%|88.5%|89%|89%|90%| ||**AC CURRENT (Typ.)**|2.8A/115VAC 1.6A/230VAC||||| ||**INRUSH CURRENT (Typ.)**|COLD STAR 60A/230VAC||||| ||**LEAKAGE CURRENT**|<0.75mA / 240VAC||||| ||**OVER LOAD**|110 ~ 140% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed||||| ||**OVER VOLTAGE**|Protection type : Shut down o/p voltage, re-power on to recover<br>13.8 ~ 16.2V<br>18.75 ~ 21.75V<br>28.8 ~ 33.6V<br>41.4 ~ 48.6V<br>55.2 ~ 64.8V||||| ||**OVER TEMPERATURE**|Shut down o/p voltage, re-power on to recover||||| ||**WORKING TEMP.**|-30 ~ +70℃(Refer to "Derating Curve")||||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH<br>℃||||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)||||| ||**VIBRATION**|10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes||||| ||**SAFETY STANDARDS**|UL60950-1, TUV EN60950-1, EN60335-1, EN61558-1<br>,CCC GB4943 approved<br>/- -<br>2 16||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC||||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃||||| ||**EMC EMISSION**|Compliance to EN55022 (CISPR22), GB9254 Class B, EN55014, EN61000-3-2Class A(<br>75% Load),EN61000-3-3<br>≤||||| ||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A||||| ||**MTBF**|601K hrs min. MIL-HDBK-217F (25<br>)<br>℃||||| ||**DIMENSION**|159*97*30mm (L*W*H)||||| ||**PACKING**|0.48Kg ; 30pcs/15.4Kg/0.75CUFT||||| ||℃<br>℃<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. Line regulation is measured from low line to high line at rated load.<br>5. Load regulation is measured from 0% to 100% rated load.<br>6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up<br>time.<br>7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by<br>mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Awww.meanwell.com)<br>8. The ambient temperature derating of<br>5<br>/1000m is needed for operating altitude greater than 2000m (6500ft).|||||| ℃ /1000m is needed for operating altitude greater than 2000m (6500ft). _File Name:LRS-150-SPEC 2016-05-11_ **LRS - 150 series** ## 150W Single Output Switching Power Supply **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Block Diagram<br>fosc : 65KHz<br>EMI RECTIFIERS POWER RECTIFIERS +V<br>I/P FILTER & SWITCHING & -V<br>FILTER FILTER<br>DETECTION<br>FG O.L.P.<br>CIRCUIT<br>CONTROL<br>O.T.P.<br>O.V.P.<br>Derating Curve Static Characteristics<br>230VAC 100<br>100<br>90<br>80 170 ~ 264VAC<br>80 85 ~ 132VAC<br>115VAC<br>60 Input only 70<br>50<br>60<br>40<br>50<br>20<br>40<br>-30 -25 0 10 20 30 40 50 60 70 (HORIZONTAL) 85 100 110 120 130 132<br>170 200 220 240 260 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:LRS-150-SPEC 2016-05-11_ **LRS - 150 series** ## 150W Single Output Switching Power Supply **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Case No.241A Unit:mm<br>4.5 152.5<br>1<br>2<br>3<br>4<br>5<br>6<br>7<br>LED<br>SVR1<br>24 78<br>159<br>6.5 150<br>Terminal Pin No. Assignment<br>Pin No. Assignment Pin No. Assignment<br>1 AC/L 4,5 DC OUTPUT -V<br>2 AC/N 6,7 DC OUTPUT +V<br>3 FG<br>22 117<br>Installation Manual<br>Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html<br>3-M3 L=5<br>3.5<br>ψ<br>2-M3 L=3.0<br>ψ<br>3.5<br>9.5<br>85 97<br>8<br>32<br>3.5<br>6.5<br>26 18 30<br>15 6 3.5 14.5<br>**----- End of picture text -----**<br> _File Name:LRS-150-SPEC 2016-05-11_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →