Image not available
Illustrative purposes only
LR600240D40
SOLID STATE RELAY
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SENSATA-CRYDOM / PARTNER STOCK
- Product type:
- SVHC: No SVHC (27-Jun-2024)
- Product Range: LR Series
| Delivery and price | |
|---|---|
| Units per pack | 6 |
| Price | 73.25 € |
| Current stock | 25+ |
| Lead time | 30 days |
## **| LR SERIES** ## PCB MOUNT SOLID STATE RELAYS ## Features - Ratings up to 40 A @ 600 VAC with external heat sink - SCR output for heavy industrial loads - AC or DC control - Zero voltage (resistive loads) or instantaneous turn-on (inductive loads) output - Optional mounting clip available (LMC-1) ## **PRODUCT SELECTION** |**Control Voltage**|**25 A**|**40 A**|**25 A**|**40 A**|**25 A**|**40 A**| |---|---|---|---|---|---|---| |**90-140 VAC**|LR600240A25-120|LR600240A40-120|LR1200480A25-120|LR1200480A40-120|LR1200600A25-120|R1200600A40-120| |**180-260 VAC**|LR600240A25-240|LR600240A40-240|LR1200480A25-240|LR1200480A40-240|LR1200600A25-240|LR1200600A40-240| |**4-32 VDC**|LR600240D25|LR600240D40|LR1200480D25|LR1200480D40|LR1200600D25|LR1200600D40| |**Description**<br>~~(Gf~~|**25A**<br>~~(Gf~~|**40A**<br>~~(Gf~~|**25A**<br>~~(Gf~~|**40A**<br>~~(Gf~~|**25A**<br>~~(Gf~~|**40A**<br>~~(Gf~~| |---|---|---|---|---|---|---| |**Operating Voltage Range (47-63 Hz) [Vrms]**|24-280|24-280|48-530|48-530|48-600|48-600| |**Transient Overvoltage [Vpk]**<br>~~Oe~~|600<br>~~Oe~~|600<br>~~Oe~~|1200<br>~~Oe~~|1200<br>~~Oe~~|1200<br>~~Oe~~|1200<br>~~Oe~~| |**Maximum Off-State Leakage Current @ Rated Voltage**<br>**[mArms]**|0.1|0.1|0.1|0.1|0.1|0.1| |**Minimum Off-State dv/dt @ Maximum Rated Voltage [V/**<br>**μsec](3)**|500|500|500|500|500|500| |**Maximum Load Current [Arms]**<br>~~Po~~<br>~~a~~|25<br>~~ee~~|40<br>~~ee~~|25<br>~~ee~~|40|25<br>~~|~~|40<br>~~|~~| |**Minimum Load Current [Arms]**<br>~~Po~~<br>~~a~~|0.15<br>~~ee~~|0.15<br>~~ee~~|0.15<br>~~ee~~|0.15|0.15<br>~~|~~|0.15<br>~~|~~| |**Maximum Surge Non-Repetitive (16.6 msec)[Apk]**<br>~~a~~<br>~~PO~~<br>~~ee~~|250<br>~~ee~~<br>~~ee~~|400<br>~~ee~~<br>~~eee~~|250<br>~~ee~~<br>~~eee~~|400|250<br>~~|~~<br>~~|~~|40<br>~~|~~<br>~~|~~| |**Maximum On-State Voltage Drop @ Rated Current [Vpk]**<br>~~PO~~<br>~~ee~~|1.6<br>~~ee~~|1.6<br>~~eee~~|1.6<br>~~eee~~|1.6|1.6<br>~~|~~|1.6<br>~~|~~| |**Maximum I² t for Fusing (8.33 msec) [A² sec]**<br>~~ee~~<br>~~PO~~|260<br>~~ee~~|660<br>~~eee~~|260<br>~~eee~~|660|260<br>~~|~~|660<br>~~|~~| |**Maximum Thermal Resistance Junction to Ceramic**<br>**Base**<br>~~PO~~|0.9°C/W|0.7°C/W|0.9°C/W|0.7°C/W|0.9°C/W|0.7°C/W| |**Minimum Power Factor (with Maximum Load)**<br>~~PB~~|0.5|0.5|0.5|0.5|0.5|0.5| ## Output[(1)] Page 1 Copyright © 2024 Sensata Technologies, Inc. www.sensata.com ## Input[(1)] |**Description**|**No Suffix**|**-120**|**-240**| |---|---|---|---| |**Control Voltage Range**|4-32 VDC|90-140 VAC|180-260 VAC| |**Must Turn-On Voltage**|4.0 VDC|90 VAC|180 VAC| |**Must Turn-Off Voltage**|1.0 VDC|10 VAC|10 VAC| |**Typical Input Current [mA](5)(6)**|9|15|11| |**Maximum Turn-on Time(4)**|1/2 Cycle|10|10| |**Maximum Turn-off Time**|1/2 Cycle|40|40| ## General[(1)] |**Description**|**Parameters**| |---|---| |**Dielectric Strength, Input/Output/Base (50/60 Hz)**|2500 Vrms| |**Minimum Insulation Resistance (@ 500 VDC)**|109Ohms| |**Maximum Capacitance, Input/Output**|8 pF| |**Ambient Operating Temperature Range**|-30 to 80 °C| |**Ambient Storage Temperature Range**|-30 to 125 °C| |**Weight (typical)**|0.5 oz. (14.4g)| |**Encapsulation**|Thermally Conductive Epoxy| ## **THERMAL DERATE INFORMATION** ## **MECHANICAL DIMENSIONS** Tolerance: ±0.02 in / 0.5 mm All dimensions are in inches [millimeters] **==> picture [278 x 100] intentionally omitted <==** **----- Start of picture text -----**<br> 1.37<br>[34.8]<br>1.0<br>[25.4] 0.50 TYP.<br>[1.2]<br>0.50<br>[12.7] 0.37<br>[9.4]<br>0.78 1.12<br>[19.8] [28.4]<br>0.25<br>[6.3]<br>**----- End of picture text -----**<br> Page 2 Copyright © 2024 Sensata Technologies, Inc. www.sensata.com Mounting Clip (Optional) **==> picture [396 x 260] intentionally omitted <==** **----- Start of picture text -----**<br> 1.73<br>[43.9]<br>1.28 LMC-1 Mounting Clip<br>[32.5]<br>1.02<br>[25.9]<br>0.110 [2.79]<br>DIA. NOTE: This plastic shell is designed<br>to secure LR Series Solid State Relay<br>to the surface of external heat sink.<br>1.28<br>[32.5] .245 1.02<br>1.25 [6.22] [25.9]<br>[31.7] 0.12<br>[3.04]<br>.007 .068<br>1.40 [0.17] [1.72]<br>[35.5] 1.14<br>1.65 [28.5]<br>[41.9]<br>1.39<br>2.05<br>ES & [35.3]<br>[52.0]<br>**----- End of picture text -----**<br> NOTE: This plastic shell is designed to secure LR Series Solid State Relay to the surface of external heat sink. ## **ORDERING OPTIONS** Example : LR600240A25R-120 **LR 600 240 A 25 R -120 Series LR Blocking Voltage 600:** 600 Vpk **1200:** 1200 Vpk **Operating Voltage 240:** 24-280 VAC **480:** 48-530 VAC **600:** 48-600 VAC **Control Voltage D:** DC Input **A:** AC Input **Rated Load Current 25:** 25 Amps **40:** 40 Amps **Switching Type Blank:** Zero voltage Turn-on **R:** Instantaneous Turn-on **AC Control Range Blank:** 4-32 VDC (DC Only) Required for valid part number **-120:** 90-140 VAC (AC Only) For options only and not required for valid part number ~~On~~ **-240:** 180-260 VAC (AC Only) Page 3 Copyright © 2024 Sensata Technologies, Inc. www.sensata.com ## **GENERAL NOTES** > (1) All parameters at 25 °C and per section unless otherwise specified > (2) Dielectric and insulation resistance are measured between input and output. > (3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 > (4) Turn-on time for instantaneous turn-on models is 0.1 ms > (5) DC input circuity incorporates active current limiter. > (6) Use suffix -120 for 120 VAC control and -240 for 240 VAC control. ## **AGENCY APPROVALS & CERTIFICATIONS** Designed in accordance with the requirements of IEC 62314 ## E116950 ## **WARNINGS** ## RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE - The product’s side panels may be hot, allow the product to cool before touching - Follow proper mounting instructions including torque values - Do not allow liquids or foreign objects to enter this product **Failure to follow these instructions can result in serious injury, or equipment damage.** HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH - Disconnect all power before installing or working with this equipment • Verify all connections and replace all covers before turning on power **Failure to follow these instructions will result in death or serious injury.** Page 4 Datasheets provided by Sensata Technologies, Inc., its subsidiaries and/or affiliates (“Sensata”) are solely intended to assist third parties (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation, and judgment in designing Buyer’s systems and products. Sensata datasheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular datasheet. Sensata may make corrections, enhancements, improvements, and other changes to its datasheets or components without notice. Buyers are authorized to use Sensata datasheets with the Sensata component(s) identified in each particular datasheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATASHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATASHEETS OR USE OF THE DATASHEETS, EXPRESS, IMPLIED, OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATASHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com. SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY, AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. ## **CONTACT US** ## **Americas** +1(800) 350 2727 sales.crydom@sensata.com **Europe, Middle East & Africa** +44 (1202) 416170 ssr-info.eu@sensata.com **Asia Pacific** sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA www.sensata.com Rev:07/15/24 Copyright © 2024 Sensata Technologies, Inc.
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →