LR5043
Data Logger, 1 Chanel, Voltage, DC Voltage, 50 V, 60000 Data, IP54
- Manufacturer: HIOKI
- Product type:
- Available until stocks are exhausted Alternative available
- SVHC: To Be Advised
- Display Type: LCD
- Product Range: LR5000 Series
- Data Interface: -
- Maximum Samples: 60K Samples
- Data Logger Type: DC Voltage
- No. of Channels / Inputs: 2 Channel
- Sensor / Measurement Type: Voltage
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 172.26 € |
| Current stock | 10+ |
| Lead time | 30 days |
DATA LOGGER LR5000 Series ## **Complete Line of Easy-to-Use Com act Lo ers with Ex anded Memor p gg p y** The new HIOKI compact data logger series easily records temperature, voltage, current, and instrumentation signals over long periods. Carried over from its highly reputed predecessor, this series includes features and functions such as 7 times the recording capacity of former models, data import during recording, continuous measurement even during battery replacement, and intuitive PC software. Flexible and easy-to-use at single and multiple locations, the new HIOKI compact data logger series is ideal for any application that requires simple set-up but long-term, reliable recording capabilities. 2 ## Meet a Wide Variety of Data Logging Applications Instrumentation Logger / Voltage Logger Record fluid flow such as for water, gas and oil. Measure flow meter output signals to Temperature Logger /Humidity Logger Manage the temperature and humidity in offices monitor flow trends. ype sR and factories. Visually monitor the data to save on air-conditioning and heating costs. Ee: = = ~ y ) — = re 3 Clamp Logger Manage the current consumption of plant and building equipment. Visually monitor ~~-~~ power costs to efficiently conduct energy and cost ~~-~~ saving activities. Use as a Voltage Logger to record pyranometer output for evaluating insulation. Use as a Clamp Logger and leakage sensor to record and monitor leakage trends. pyranometer **==> picture [103 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Voltage logger has a Preheat function<br>**----- End of picture text -----**<br> Use as a Temperature Logger to record warehouse temperatures for visually monitoring temperature changes of products and goods. Use as an Instrumentation Logger to record pressure sensor output and monitor fluctuations in air or oil pressure. 3 ## Easy operation in just steps ! a Install a Data Logger, set an interval, and start measuring. **==> picture [504 x 540] intentionally omitted <==** **----- Start of picture text -----**<br> Easy to start recording Unlimited installation capabilities<br>Wall-mounted Holder<br>STEP<br>(sold separately)<br>Not usable with LR5051<br>@0 @6, © 00 @. Ei)<br>Set up<br>&Record fey Magnetic Strap<br>Set your recording interval. Hold the REC button (sold separately)<br>(from one second to 60 minutes) for two seconds to<br>start recording. (included, except Kickstand<br>for Model LR5051)<br>Download data<br>HIOK! ) using infrared communication. Grab the Data Logger from the worksite and connect to a PC.<br>ick val © ,<br>STEP<br>Communication Adapter<br>Transfer data LR5091<br>Retrieving the Transfer data from Data Logger to<br>from Data Logger Data Logger PC using a USB connection<br>to PC<br>Using the Data Collector's internal memory, import data from up to 16 Data<br>Loggers installed on site.*<br>Download data<br>using infrared<br>! [Requires optional ] communication.<br>Communication<br>sey * o \s<br>Adapter<br>Importing to Retrieving Transfer data from Data Logger to<br>or 86 a Data Collector the Data Collector PC using a USB connection<br>J e<br>Data Collector Front Back * Data for up to 16 channels can be stored. Combine up to 16 single-channel Data Loggers (Models LR5011, LR5031,<br>Data Collector LR5041, LR5042, and LR5043), or up to eight 2-channel Data Loggers (Models LR5001, and LR5051).<br>LR5092-20 Using an optional SD Memory Card, the amount of data that can be import-<br>ed is practically limitless.<br>Top surface of LR5092-20<br>SD Card slot<br>or<br>=» ee]<br>USB Connector<br>Importing to an Transfer data from SD Memory Card Transfer data directly<br>SD Memory Card ee within Data Collector to PC using USB eee from SD Memory Card<br>**----- End of picture text -----**<br> View data graphically and easily print using the bundled software. ## **STEP** View graphs and manage data 4 ## Advanced Features and Functions ## Install Almost Anywhere Recording capacity up to 7 times previous models Large internal memory stores 60,000 data points per channel. Long-term recording capability exceeds that of previous models. Easily mount the light-weight, pocket-sized loggers in tight spaces. |Interval<br>times<br>~~Pp~~|Instantaneous value<br>~~Pp~~<br>~~TY~~|Statistical value| |---|---|---| |1s<br>~~Pp~~|16h<br>40m<br>~~Pp~~<br>~~TY~~|-| |2s|1d<br>9h<br>20m<br>~~TY~~|8h<br>20m| |5s<br>~~-~~|3d<br>11h<br>20m<br>~~-~~|20h<br>50m| |10s<br>~~-~~|6d<br>22h<br>40m<br>~~-~~<br>~~———~~|1d<br>17h<br>40m| |15s<br>~~-~~|10d<br>10h<br>~~-~~<br>~~———~~|2d<br>14h<br>30m| |20s|13d<br>21h<br>20m<br>~~———~~<br>~~OtCt~—S~~|3d<br>11h<br>20m| |30s<br>~~—~~|20d<br>20h<br>~~———~~<br>~~OtCt~—S~~<br>~~—~~|5d<br>5h| |1m<br>~~—~~|41d<br>16h<br>~~OtCt~—S~~<br>~~—~~|10d<br>10h| |2m<br>~~—~~<br>~~|~~|83d<br>8h<br>~~—~~<br>~~|~~<br>~~—C‘idr~~|20d<br>20h| |5m<br>~~—~~<br>~~|~~|208d<br>8h<br>~~—~~<br>~~|~~<br>~~—C‘idr~~<br>~~—~~|52d<br>2h| |10m<br>~~—~~<br>~~|~~|416d<br>16h<br>~~—~~<br>~~|~~<br>~~—C‘idr~~<br>~~—~~|104d<br>4h| |15m|625d<br>~~—~~|156d<br>6h| |20m|833d<br>8h<br>~~—~~|208d<br>8h| |30m|1250d<br>~~—~~<br>~~-——~~|312d<br>12h| |60m|2500d<br>~~-——~~|625d| **==> picture [45 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Actual size<br>**----- End of picture text -----**<br> A The maximum recording time depends on battery life. The battery may need to be replaced during long-term recording. Customers using the previous Model 3636-20 Clamp Logger should note that the LR5051 can only record 15,000 points of average data, vs. 32,000 data points available in the 3636-20. ## Easy-to-see dual display Temperature and humidity or current channels can be displayed. View maximum and minimum values while measuring. ## Record without missing fluctuations ~~=~~ Moist environments s ~~é~~ IP54 splash-proof rating withstands operation in extremely humid environments like kitchens and pipe rooms. (Except Model LR5051) With usual (instantaneous value) recording at long intervals, detailed fluctuations occurring within the intervals are missed. However, with the statistical value recording mode, detailed fluctuations are captured even when they occur during long recording intervals. In STAT mode, measurement is taken every second, and the maximum, minimum, average, and instantaneous values within the specified interval are recorded. **==> picture [236 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> Data interval(2sec to 60min)<br>1sec<br>Data interval(2sec to 60min) Maximum<br>data<br>Maximum<br>data<br>Average Instant<br>data data<br>Ani<br>Average<br>data<br>Instant<br>data<br>Input signal Minimum<br>(Temperature, data<br>Voltage, etc.) Minimumdata Time<br>Record 4 data Record 4 data<br>for interval for interval<br>**----- End of picture text -----**<br> Transfer data even during recording Continue to record even when transferring data. **==> picture [44 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> Transfer data<br>from Data Logger<br>to PC!<br>**----- End of picture text -----**<br> **==> picture [45 x 13] intentionally omitted <==** **----- Start of picture text -----**<br> In the middle of<br>Recording ...<br>**----- End of picture text -----**<br> ## Batteries last up to 2 years Energy-efficient design provides up to two years of battery life (For the LR5011 only. Actual battery life depends on model type and settings). ## Never worry about a dead battery The worry-free backup function preserves measurement data even after the battery dies. ## Never worry about operating errors ## Replace batteries while recording Worry-free backup preserves recorded data even if a _Note. With the recording is interrupted_ LR5001 _,_ new measurement is started by mistake. _during battery replacement if the battery is very weak. After batteries are replaced, recording resumes automati-_ **!** _cally. Previously recorded data is not lost during battery replacement._ a ad Recording continues for about 30 seconds even with the battery removed. 5 ## Bundled Software Ensures Smooth and Easy Data Analysis m7 |_| Import data to a PC and create graphs Sm ||)= SimCase broert ln) BS [ee|| Woon! fo~ | Use the LR5000 Utility program to import Data Logger data to a PC to make graphs and analyze data further. Easily print results using your PC. ## Show specific values using the cursor function Use the A/B cursors to select any location on a graph and display its value. The PC software can also calculate maximum, minimum, and average values between A and B cursors. ## Simple file aggregation and management Transferred data can be combined with data previously transferred (from the same Data Logger unit) into one data on the PC. **==> picture [233 x 63] intentionally omitted <==** **----- Start of picture text -----**<br> Ld Past data re New data ee Saving 1 file<br> Display data from former Data Logger models<br>The PC application also supports data collected from the HIOKI<br>36XX Series Data Loggers.<br>**----- End of picture text -----**<br> ## Display data from former Data Logger models ## LR5000 Utility Specifications •Import/export Data Logger settings (LR5091 or Configurating LR5092-20 required) Data Logger •Settings sent to each LR5000 logger are also saved to the PC. •Graphically display data for up to 16 channels •Select colors and display/hide any channel and graph Graph display •Copy graph images to clipboard •Display statistical data (maximum, minimum and average) •Scaling function |Print function|Print graphs<br>Print statistical data.| |---|---| |Data processing|Scaling<br>Power calculation<br>Energy cost calculation<br>Operating ratio calculation<br>Integration<br>Dew point temperature<br>Calculate between channels| |Operating<br>environment|**OS**:Windows XP (SP2 or later)<br>Windows Vista (SP1 or later) / Windows 7<br>**CPU**: 1GHz or more<br>**Memory**: 512MB or more<br>**Interface**: USB<br>**Free space in hard disk**:30MB or more| 6 ## Communication Adapter and Data Collector Specifcations |Communication Adapter and Data Collector Specifcationsications|Communication Adapter and Data Collector Specifcationsications|Communication Adapter and Data Collector Specifcationsications| |---|---|---| |Communication Adapter and Data Collector Specifcationsications||| |Physical<br>appearance|——=—<br>LUSB..J<br>«iGU<br>CE<br>;|i<br>use.<br>a<br>sz<br>He<br>7 ©<br>Warranty| |Model|Communication Adapter LR5091|Data Collector LR5092-20| |Features|•Transfer data from a Data logger to a PC<br>•Transfer Data Logger configurations or clock settings<br>from a PC to the Data Logger|•Collect recorded data from the Data Logger to internal memory or SD card<br>•View collected data in a graph<br>•Transfer Data Logger configurations or clock settings from internal<br>memory or SD card to the Data Logger<br>•Transfer data from a Data Logger to a PC<br>•Transfer Data Logger configurations or clock settings from a PC to<br>the Data Logger| |Interface with<br>Data Logger|Infrared optical communications|| |Interface with PC|USB2.0,Full Speed,Series Mini B Receptacle|| |Clock functions|-<br>~~Pe~~|Auto calender,auto leap year| |Display|-<br>~~pO~~|Dot-matrix LCD(128 × 64 dots)| |Display items|-<br>~~pO~~|Data Logger configurations (Interval, Start/Stop method, Recording<br>mode, Scaling, Alarm, Power-saving mode, Clock, Range)<br>Collected data(Record list,Maximum data,Minimum data,Average,Graph,Value)| |Internal memory<br>capacityof data|-|60,000 data elements ×16ch (instantaneous value mode)<br>15,000 data elements ×16ch(statistical value mode)| |Removable stor-<br>age media|-|SD Card (SDHC, Max 32GB)<br>Save data and configurations| |Operatingenvironment|Indoors|| |Power supply|DC 5 V (USB bus power) Maximum rated power 0.5 VA|DC 3 V (LR6 (AA) Alkaline battery 1.5 V×2) or DC 5 V (USB bus power)<br>Maximum ratedpower 1 VA| |Batterylife|-<br>~~po~~|Approx. 12 hours or 500 times of data collection| |Operating temperature<br>and humidity|0˚C (32˚F) to 40˚C (104˚F) , 80% RH or less (non-condensating)<br>~~po~~|| |Dimensions & Mass|83 mm (3.27 in)W × 61 mm (2.40 in)H × 19mm (0.75 in)D,<br>43 g (1.5 oz)|91 mm (3.58 in)W × 141 mm (5.55 in)H × 31 mm (1.22 in)D,<br>215 g (7.6 oz) (excluding batteries)| |Accessories|USB cable (1 m)×1,<br>CD (Application software "LR5000 Utility") × 1|Instruction manual ×1, Operation manual×1,<br>LR6 (AA) Alkaline battery 1.5V×2, USB cable (1 m)×1,<br>CD(Application software "LR5000 Utility")× 1| LR5092-20 Option SD Memory Card (2GB) Z4001 ## LR5000 Series Common specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year) |LR5000 Series Common specifications|| |---|---| |Storage capacity|**Instantaneous value mode**<br>60,000 data sets per channel<br>**Statistical value mode**<br>15,000 data sets per channel<br>_Note.Customers using the previous Model_3636-20_Clamp Logger should note that the_LR5051_can_| ||_only record 15,000 points of average data, vs. 32,000 data points available in the_3636-20_._| |Display items|Measured value, Interval configration, Date, Time,<br>Alarm, Remaining battery power, Number of data,<br>Maximum data,Minimum data<br>**Recording start**<br>Manual start<br>Timer start| |Recording|**Recording stop**| |start / stop|Manual stop| |Data backup|Timer stop<br> When the memory capacity is full<br>(One time recording)<br>Data from the last recording session is always backed up.<br>Back up recorded data and configuration when battery is dead.| |Interface|Infrared optical communications withLR5091, LR5092-20| ||During battery replacement, recording and clock operations| ||are preserved for about 30 seconds. (Recording operation| |Power supply|continues if the battery is replaced within about 30 seconds.)| ||_Note. With the_LR5001_, recording is interrupted during battery replacement if the_| ||_battery is very weak. After batteries are replaced, recording resumes automatically._| ||_Previously recorded data is not lost during battery replacement._| Recording 1/ 2/ 5/ 10/ 15/ 20/ 30 seconds interval 1/ 2/ 5/ 10/ 15/ 20/ 30/ 60 minutes **One time recording** Stop recording when the memory capacity is full. Recording **Endless recording** methods Continue recording even when the memory capacity is full. (old data is overwritten.) **Instantaneous recording** Recording modes Instantaneous values are recorded at every recording interval. (instantaneous **Statistical value recording** value mode/ Measure at one second intervals, and record the statistical value instantaneous, maximum, mode) minimum, and average values within every recording interval. LR5000 Series common options Magnetic Strap Wall-mounted Holder Z5004 LR9901 Not compatible with Model LR5051 7 Analysis of measurement data on a PC requires the optional LR5091 Communication Adapter or LR5092-20 Data Collector. See page 6 for details. |ecifications<br>Physical<br>appearance<br>~~RC~~|ecifications<br>Bundled sensor (LR9504)<br>(Sensor is out of warranty)<br>4<br>ce<br>| eox<br>~~RC~~|ecifications<br>Bundled sensor (LR9504)<br>(Sensor is out of warranty)<br>4<br>ce<br>| eox<br>~~RC~~|ecifications<br>Bundled sensor (LR9504)<br>(Sensor is out of warranty)<br>Optional sensor (LR9604)<br>(Sensor is out of warranty)<br>ce<br>|<br>ce<br>"e0O@| |---|---|---|---| |Model<br>~~RC~~|HUMIDITY LOGGER LR5001<br>~~RC~~||TEMPERATURE LOGGER LR5011| |Features<br>~~RC~~|Temperature and humidity are recorded simultaneously using<br>supplied or optional temperature and humidity sensors.<br>~~RC~~||Temperature and humidity are recorded simultaneously using<br>Temperature measurement with external temperature sensor.<br>Select the sensor according to the measurement object| |Measurement<br>items|Temperature 1ch and Humidity 1ch||Temperature 1ch| |Measurement<br>range|Temperature : -40˚C to 85˚C<br>Humidity: 0% to 100% RH||-40.0˚C to 180˚C<br>*Depends on measurement range of sensor.| |Accuracy|Temperature<br>(LR5001+ Sensor)<br>Temperature : ˚C<br>85<br>70<br>35<br>0<br>-40<br>±2.0˚C<br>±1.0˚C<br>±0.5˚C<br>±1.0˚C|Humidity (LR5001+Sensor)<br>Temperature : ˚C<br>90<br>70<br>50<br>10<br>0<br>100<br>-40<br>0<br>10<br>20<br>30<br>50<br>Relative humidity : %rh<br>±<br>10%rh ±<br>10%rh<br>±<br>10%rh<br>±<br>~~8~~%rh<br>±<br>~~6~~%rh<br>±<br>8%rh<br>±<br>6%rh<br>±<br>5%rh<br>±<br>~~8~~%rh<br>±<br>~~8~~%rh<br>±<br>6%rh<br>±<br>6%rh<br>*<br>_Values provided for reference only._<br>~~*~~<br>~~*~~<br>~~*~~<br>~~rite]~~|+Sensor)<br>(LR5011+Sensor)<br>Temperature : ˚C<br>180<br>120<br>70<br>35<br>0<br>-40<br>±5.0˚C<br>±2.0˚C<br>±1.0˚C<br>±0.5˚C<br>±1.0˚C<br>50<br>85<br>±<br>15%rh<br>_Values provided for reference only._<br>*<br>~~rite]~~| |Waterproof and dust-<br>proofperformance|IP54 (splash-proof construction)<br>_Values provided for reference only._||| |Operating temperature<br>and humidity|-20˚C (-4˚F) to 70˚C (158˚F) , 80% RH or less (non-condensating)||| |Dimensions &<br>mass|Approx. 79 mm (3.11 in)W × 57 mm (2.24 in)H × 28 mm (1.10 in)D<br>105g (3.7 oz)||| |Power supply|LR6(AA)Alkaline battery1.5 V×1||| |Accessories|Humiditysensor LR9504×1,Kickstand||Kickstand| ||LR6(AA)Alkaline battery1.5 V×1,Instruction manual ×1,Operation manual×1||| |Battery life|Case 1 : Approx. 3 months Case 2: Approx. 20 days||Case 1 : Approx. 2years Case 2: Approx. 2 months| ||Case 1 : 1min. recording interval, power-saving mode, Instantaneous recording, environmental temp.20˚C<br>Case 2 :1sec. recordinginterval, power-savingmode,Instantaneous recording,environmental temp.20˚C||| _(Reference) When the recording interval is set to 10 minutes, the_ LR5001 _Temperature and Humidity Logger can measure for about one year between battery replacements._ LR5001 Options Humidity Sensor ## n Humidity Sensor 30 mm (Thickness : 8 mm) l Models (length) : LR9501 (1 m) 13 mm LR9502 (5 m) ~~—— ———~~ 1 m (LR9501) LR9503 (10 m) ~~r~~ 10 m 5 m (LR9502)(LR9503) ~~T a~~ LR9504 (40 mm, bundled accessory) l Temperature range : -40.0˚C to 85.0˚C ~~(G3 kaa~~ l Humidity range : 0.0% to 100.0% RH 40 mm l Response time : Approximately 300 seconds (LR9504) (Temperature and humidity; 90% response time) LR5011 Options Temperature Sensor n Molded plastic type n Lug type diameter:6 mm 28 mm 1 m 5 m (LR9601)(LR9602) Outer diameterInner diameter:3.2 :7 mmmm 5 m 1 m (LR9612)(LR9611) ~~a~~ 10 m (LR9603) ~~oy~~ 10 m (LR9613) ~~ir~~ 45mm (LR9604) l Models (length) : LR9601 (1 m) LR9602 (5 m) l Models(length) : LR9611 (1 m) LR9612 (5 m) LR9603 (10 m) LR9604 (45 mm) LR9613 (10 m) l Temperature range : -40˚C to 180˚C l Temperature range : -30˚C to 180˚C l Response time : Approx. 100 seconds (90% response time) l Response time : Approx. 45 seconds (90% response time) l Material : Cable : Silicon Sensor head : Silicon l Material: Cable : Silicon Sensor head : Nickel-plated brass ## n Sheathed type Sheathed type n Needle type ~~——————~~ 180 mm ~~|r|~~ 25 mm diameter 4 mm diameter 1.3 mm 1 m 1 m ~~rs i a~~ l Models(length) : LR9621(1 m) l Models(length) : LR9631(1 m) l Temperature range : -40˚C to 120˚C l Temperature range : -40˚C to 120˚C l Response time : Approx. 90 seconds (90% response time) l Response time : Approx. 20 seconds (90% response time) l Material : Cable : Silicon Sensor head : SUS304 l Material : Cable : Silicon Sensor head : SUS304 Analysis of measurement data on a PC requires the optional LR5091 Communication Adapter or LR5092-20 Data Collector. See page 6 for details. Product Specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year) See page 6 for Common specifications Physical appearance ~~@~~ Bundled accessory ~~CED~~ Bundled accessory e00e@ (LR9801) eoo@ (LR9802) LR5042(5V) Model ~~pO~~ INSTRUMENTATION LOGGER LR5031 VOLTAGE LOGGER LR5041, LR5042, LR5043 For recording instrumentation signals and measuring analog outputs from Features ~~po~~ For recording 4-20 mA instrumentation signals, etc. sensors and other devices Measurement items ~~PT~~ For Instrumentation / 0 to 20 mA DC, 1ch DC voltage 1ch Measurement LR5041: -50.00 mV to 50.00 mV DC -30.00 to 30.00 mA LR5042: -5.000 V to 5.000 V range LR5043: -50.00 V to 50.00 V Accuracy ~~pO~~ ±0.5% rdg. ±5 dgt. (@23˚C ±5˚C) ±0.5% rdg. ±5 dgt. (@23˚C ±5˚C) Waterproof and dustIP54 (splash-proof construction) proof performance Operating temperature -20˚C(-4˚F) to 70˚C(158˚F) , 80% RH or less (non-condensating) and humidity Dimensions & Mass Approx. 79 mm (3.11 in)W × 57 mm (2.24 in)H × 28 mm (1.10 in)D, 105 g (3.7 oz) Power supply LR6 (AA) Alkaline battery 1.5 V×1 Accessories Connection Cable LR9801×1, Kickstand Connection Cable LR9802×1, Kickstand LR6 (AA) Alkaline battery 1.5 V×1, Instruction manual ×1, Operation manual×1 Case 1 : Approx. 2 years Case 2: Approx. 2 months Battery life Case 1 : 1min. recording interval, power-saving mode, Instantaneous recording, environmental temp.20˚C Case 2 : 1 sec. recording interval, power-saving mode, Instantaneous recording, environmental temp.20˚C Other ~~PO~~ - Preheat function (When using preheat function, a separate external power supply is required.) LR5031 Option LR5041, LR5042, LR5043 Option 2 wires 4 wires 1m 1m CONNECTION CABLE LR9801(Bundled accessory) CONNECTION CABLE LR9802 (Bundled accessory) gProduct Specificationsuaranteed for 1 year) See pag(Accuracy guaranteed for 1 year, Post-adjustment accuracy e 6 for Common specifications LR5051 OptionsLoad current 3 m (9.84 ft) cord length 3 m (9.84 ft) cord length Connection cord 9219 is (Sensor warranty is required (sold separately) one year) Physical Physical **Insulatedconductor** *Sensor is sold separately. appearance appearance a_ *For customers using the previous Model 3636-20 ~ Clamp Logger, please note the difference in record-able average data points available in the LR5051. Not CE marked (Please refer to page 4.) Model ~~ee~~ CLAMP ON SENSOR 9669 CLAMP ON SENSOR CT6500 ~~ee~~ CLAMP ON SENSOR 9695-02 Model CLAMP LOGGER LR5051 Measurable con- _φ_ 55 mm (2.17") or less, ductor diameter ~~ee~~ 80 (3.15") × 20 (0.79") mm busbar _[φ]_[46 mm (1.81") or less] _φ_ 15 mm (0.59") or less Recording load current of 50Hz/60Hz Recording leak current Primary current rating ~~ee~~ 1000 A AC 500 A AC 50 A AC Features *Current and leak current that occur intermittently cannot be measured. Accuracy (45Hz to 66Hz) ~~ee~~ ±1.0% rdg. ±0.01% f.s. ±1.5% rdg. ±0.03% f.s. ±0.3% rdg. ±0.02% f.s. The Clamp Logger LR5051 may be affected by high-frequency noise during leak current measurement. Please contact Hioki for more information if you plan to Maximum rated voltage to earth ~~ee~~ CAT III 600 V rms CAT III 600 V rms CAT III 300 V rms use the instrument in an environment where it would be affected by such noise. Maximum allowable input (45 to 66 Hz) 1000 A continuous 600 A continuous 60 A continuous Measurement items When Using 9669 AC Current : 1000 A range(2 channels) Dimensions & mass ~~ee~~ 42 (1.65")D mm, 590 g (20.8 oz.)99.5 (3.92")W × 188 (7.40")H × 42 (1.65")D mm, 360 g (12.7 oz.)77 (3.03")W × 151 (5.94")H × ~~ee~~ 19 (0.75")D mm, 50 g (1.8 oz.)51 (2.01")W × 58 (2.28")H × Measurement When Using CT6500 : 50.00 A / 500.0 A range ~~|[T][SC]~~ length range When Using 9675 When Using 9695-02 : : 500.0 mA / 5.000 A range5.000 A / 50.00 A range sa Connection Cord 9219(For 9695-02 connection) ~~e a= [a 3~~ ) : 3m(9.84ft) When Using 9657-10 : 500.0 mA / 5.000 A range Load current Accuracy ±0.5% rdg. ±5dgt. + Clamp sensor accuracy **Insulatedconductor** 3 m (9.84 ft) cord length **Insulatedconductor** 3 m (9.84 ft) cord length Physical Waterproof and dust-proof performance Not waterproof appearance cE 4ce OS Operating temperature and humidity 80% RH or less -0˚C (32˚F) to 50˚C (122˚F) ,(non-condensating) Model ~~po~~ CLAMP ON LEAK SENSOR 9675 CLAMP ON LEAK SENSOR 9657-10 Dimensions & mass Approx. 79 mm (3.11 in)W × 70 mm (2.76 in)H × 37 mm (1.46 in)D, 165 g(5.8 oz) Measurable conductor diameter ~~po~~ _φ_ 30 mm _φ_ 40 mm Power supply LR6 (AA) Alkaline battery 1.5V × 2 Primary current rating ~~po~~ 5 A AC (Using with LR5051) 5 A AC (Using with LR5051) Accuracy (45Hz to 66Hz) ~~Po~~ ±1.0% rdg. ±0.005% f.s. ±1.0% rdg. ±0.05% f.s. Accessories Instruction manual ×1LR6 (AA) Alkaline battery 1.5V × 2, Operation manual×1 Lag current ~~Po~~ 1 mA(When 10 A AC is input) 5 mA(When 100 A AC is input) Case 1 : Approx. 1 years Case 2: Approx. 1 months Measurable conductor ~~Po~~ Insulated conductor Insulated conductor Maximum allowable input (45 to 66 Hz) ~~Po~~ 10A continuous 30A continuous Battery life Case 1 : 1min. recording interval, power-saving mode, Instantaneous recording, environmental temp.20˚C Case 2 : 1 sec. recording interval, Dimensions & mass[60 (2.36")W × 113 (4.45")H × ] 74 (2.91")W × 145 (5.71")H × power-saving mode, Instantaneous recording, environmental temp.20˚C ~~|~~ 24 (0.94")D mm, 160g (5.6 oz.) 42 (1.65")D mm, 380g (13.4 oz.) _Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies._ HEADQUARTERS 81 Koizumi Ueda, Nagano 386-1192 Japan www.hioki.com HIOKI (Shanghai) SALES & TRADING CO., LTD. TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360 info@hioki.com.cn / www.hioki.cn HIOKI SINGAPORE PTE.LTD. TEL +65-6634-7677 FAX +65-6634-7477 info-sg@hioki.com.sg / www.hioki.com.sg HIOKI KOREA CO., LTD. TEL +82-2-2183-8847 FAX +82-2-2183-3360 info-kr@hioki.co.jp / www.hiokikorea.com HIOKI EUROPE GmbH TEL +49-6173-31856-0 FAX +49-6173-31856-25 hioki@hioki.eu / www.hioki.com HIOKI TAIWAN CO., LTD. TEL +886-3-3467160 FAX +886-3-3467162 info-tw@hioki.com.tw / www.hioki.com DISTRIBUTED BY HIOKI USA CORPORATION TEL +1-609-409-9109 FAX +1-609-409-9108 hioki@hiokiusa.com / www.hiokiusa.com All information correct as of Jan. 23, 2019. All specifications are subject to change without notice. series_LR5000E22-91E Printed in Japan
Updated at June 4, 2026
Hioki is a distinguished manufacturer recognized globally for its innovative and precision-driven test and measurement solutions. The company develops advanced, high-quality instruments designed to meet the rigorous demands of engineers, technicians, and researchers across the electronics, automotive, and energy sectors. Within its comprehensive portfolio of measurement technology, Hioki is particularly noted for its highly reliable data acquisition and data logging systems. Their precision dataloggers are meticulously engineered to gather crucial information with unparalleled accuracy, enabling professionals to seamlessly monitor, record, and analyze complex electrical and environmental phenomena over time. Built with a commitment to user-friendly operation and robust performance, Hioki instruments are designed to streamline complex workflows and accelerate both research and industrial diagnostics. By delivering exceptional build quality and consistent, verifiable results, the brand remains a trusted choice for critical measurement tasks and long-term data collection.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →