LR5-02LENW
Body Unit, LR5 Series Signal Tower, Off-White, Mounting with Pole/L-Bracket, 24 VDC, LR5 Series
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: PATLITE
- Product type: Signal Indicator Accessories
- SVHC: No SVHC (21-Jan-2025)
- For Use With: Patlite LR5 Series Signal Towers
- Product Range: LR5 Series
- Accessory Type: Body Unit
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 253.66 € |
| Current stock | 10+ |
| Lead time | 30 days |
Drawing No. LR5-02WE-W18 Rev. B Page 1/8 ## **SPECIFICATIONS** Product Name:Signal Tower with Ethernet Model:LR5-02□ENW、LR5-□02□E□W-□ |Drawing No.|Rev.|Page| |---|---|---| |LR5-02WE-W18|B|2/8| ## **1 . General Specifications** |**1.General Specifications**|**1.General Specifications**|**1.General Specifications**|||||| |---|---|---|---|---|---|---|---| |Rated Voltage|||24V DC||||| |OperatingVoltage Range|||Rated Voltage ± 10%||||| |Rated Current<br>Consumption|||Main Unit||||Typ.15 mA Max. 20 mA| ||||LED Unit||||Typ.40 mA Max. 45 mA(per tier)| ||||Buzzer Unit||||Typ.40 mA Max. 45 mA| |OperatingAmbient Temperature|||-20℃ ~+50℃||||| ||OperatingAmbient Humidity||90% RH or less,no freezing,no condensation||||| ||Storage Ambient Temperature||-30℃ ~+60℃||||| ||Storage Ambient Humidity||90% RH or less,no freezing,no condensation||||| ||MountingLocation||Indoors||||| ||MountingDirection||Upright||||| ||Protection Rating||WE Type||IP 65(IEC 60529)||| ||||LE Type||IP 54(IEC 60529)||| ||Environmental Condition||Upright||||| ||Insulation Resistance||More than 5M Ω at 500 VDC between the livepart and non-current carryingmetallicpart||||| ||Withstand Voltage||500 VAC applied for 1 min between live part<br>and non-current carryingmetallicpart without breakinginsulation||||| ||Mass (Tolerance:±10%)||(LED Unit)+[Buzzer Unit]||||| ||||WE Type||0.1kg+(0.04kg)×Tiers +[0.05kg]||| ||||LE Type||0.39kg+(0.04kg)×Tiers +[0.05kg]||| ||Outer Dimensions||Refer to the Outer Dimension Drawing||||| ||Buzzer Sound<br>/Typical Frequency||No.1|Rapid intermittent beep/ 3,378Hz|||| ||||No.2|Continuous beepsound / 3,378Hz|||| ||||No.3|Rapid Hi-Lo / 2,016Hz&3,012Hz|||| ||||No.4|Sweepsound / 1,000Hz-4,032Hz|||| ||Setting||Dependingon DIP Switch Settings Refer to the 7.Buzzer Pattern Set-up||||| ||Sound Pressure Level||Typ.85dB||||| ||||Sound Reduction Approx. -10dB<br>Dependingon DIP Switch Settings Refer to the 7.Buzzer Pattern Set-up||||| ||Environmental Condition||Buzzer sound No.4 was measured from the total circumfrence of the Buzzer Unit at 1m||||| |Interfaces||Power Supply|Screwless Terminal Block(24V DC)||||| ||||Supported<br>Wire Diameter|||Single wire:φ0.5~1.2mm Stranded wire:0.2-1.5mm2(AWG24-16)|| |||Ethernet|RJ-45 Connector||||| |Network Communication Format|||Ethernet (IEEE802.3 Conformity)<br>10BASE-T/100BASE-TX(Auto-MDI/MDIX)||||| |Operation Interface|||Switch for Initialize ×1pc||||| |Accessories|||WE Type||Hexagon nut with flange(M3)×3pcs||| ||||LE Type||L-bracket ×1pc||| |Supported Unit|||LED Unit||||LR5-E-□、LR5-E-□Z<br>*Maximum number of 5 tiers for LED Units| ||||Buzzer Unit||||LR5-BW| ||||WD transmitter||||WDT-5LR-Z2| |Supported Option|||Wall-Mount Bracket||||SZK-002W,SZK-001U| ||||Circular Bracket||||SZ-010| ||||L-bracket||||SZL-001| ||||Circular Bracket||||SZW-001W| ||||MountingBracket||||SZW-002W| ||||AC Adapter||||ADP-001C| |||Drawing No.|Rev.|Page| |---|---|---|---|---| |||LR5-02WE-W18|B|3/8| |||||| |Conformity Standards|UL 508 ,CAN/CSA C22.2 No.14-18<br>FCC Part15 SubpartB(Class A), ICES-003 Issue 7(Class A)<br>EN 61000-6-4, EN 61000-6-2, EN IEC 63000<br>KS C 9610-6-4,KS C 9610-6-2|||| |Remarks|・Due to the characteristics of the LED elements, a variation in difference of<br>the color tone and brightness of every product may occur<br>・Conforms to the CE/UKCA requirements<br>・UL Recognized Component(File No.E215660)<br>・Modbus is a registered trademark of Modicon Inc.<br>(Schneider Automation International).<br>・Microsoft Edge is registered trademark of Microsoft Corporation in the United States<br>and other countries.<br>・Google Chrome is a trademark or registered trademark of Google LLC.|||| ## **2.Model Number Configuration** **==> picture [449 x 351] intentionally omitted <==** **----- Start of picture text -----**<br> Unit Model(Body Unit)<br>L R 5 -0 2 W ENW<br>Size Body Color<br>5 Φ50 W Off-white<br>Rated Voltage Mounting/Wiring<br>02 24V DC WE Direct mounting, Ethernet communication<br>LE Mounting with pole/L-bracket, Ethernet communication<br>Assembly Model<br>—<br>L R 5 -3 0 2 WEBW RY G<br>LED Unit Color<br>R Red<br>Body Color Y Amber<br>Size Rated Voltage W Off-white G Green<br>5 Φ50 02 24V DC B Blue<br>Buzzer Unit C White<br>Tiers B With buzzer From top to bottom<br>1 1Tier N No buzzer<br>2 2Tiers<br>3 3Tiers Mounting/Wiring<br>4 4Tiers WE Direct mounting, Ethernet communication<br>5 5Tiers LE Mounting with pole/L-bracket, Ethernet communication<br>**----- End of picture text -----**<br> |Drawing No.|Rev.|Page| |---|---|---| |LR5-02WE-W18|B|4/8| ## **3.Action Specifications** |**3.Action Specifications**|||| |---|---|---|---| |LED unit operation control||7patterns + off can be controlled for each LED unit color|| ||Flashing<br>Pattern|1|Continuous ON| |||2|Flashing(Slow) 【0.5sec ON / 0.5sec OFF】| |||3|Flashing(Medium) 【0.25sec ON / 0.25sec OFF】| |||4|Flashing(Fast) 【0.125sec ON / 0.125sec OFF】| |||5|Single Flash| |||6|Double Flash| |||7|Triple Flash| |Buzzer unit operation control||ON/OFF control|| ※ The intermittent buzzer and the LED pattern do not synchronize. ## **4.Function Specifications** ## 4.1 LED unit, Buzzer unit control function |4.1 LED unit, Buzzer unit control|function| |---|---| |Modbus/TCP|Controllable with Modbus/TCP Command| |HTTP/HTTPS|Controllable with HTTP/HTTPS Command| |Socket Communication|Controllable with PNS Command| |4.2 Status Acquisition Function|| |Modbus/TCP|Current status of Signal Tower, Buzzer<br>can be acquired byModbus/TCP Command.| |HTTP/HTTPS|Current status of Signal Tower, Buzzer and Firmware Version<br>can be acquired byHTTP/HTTPS Command.| |Socket Communication|Current status of Signal Tower,Buzzer can be acquired byPNS Command.| ## 4.3 External Monitoring Function |Ping M|onitoring|Network abnormalitydetection bysendingPingnetwork devices| |---|---|---| ||Number of Monitoring|1| ||MonitoringCycle|1~600 seconds| ||SendingCount|The number of times to detect can be set from 1 to 30.| ||Number of Sending|The number of sendingPingbyone monitoringcan be set from 1 to 3.| |Number of Monitoring<br>Modbus/TCP Monitoring||Monitor the connection status with the Modbus/TCP master| ||Number of Monitoring|1| |4.4 Setting Function||| |<br>Automatic Network Setting||Network setting in this product can communicate with<br>a DHCP server to be set automatically.| |Configuration Setting||Various configurations of the Main Unit can be read and written as settingfiles| |Main Unit Setting||Various settings of the main body can be done with a web browser.<br>Supported browsers:Microsoft Edge,Google Chrome| |Firmware Update||Firmware of the main unit can be updated usingWEB browser.| |Languages supported<br>on the settingscreen||Japanese, English, Traditional Chinese, Sinplified Chinese, Korean, Thai<br>German,French,Italian,Spanish| Drawing No. Rev. Page LR5-02WE-W18 B 5/8 ## **5.Wiring** - ・Fuse Fuse Rating 250V / 1A - ※Reccomended Fuse : 250V/1A (5 × 20mm Fast-Acting Glass Body Cartridge Fuse) - ・LAN cable Since the RJ-45 connector at the end of the LAN cable is connected to the body, it should meet the dimensional requirements shown below. **==> picture [257 x 175] intentionally omitted <==** **----- Start of picture text -----**<br> WE RJ-45 connector<br>Wire entry hole’ Jy > Pa<br>(¢20mm) L<br>JJn : 4 a<br>LE Type NeX |N< ™ 40 mm<br>Inner diameter of pole)<br>(¢ 15.5mm)<br>*When using the wall-mount bracket SZK-002W and SZK-001U,<br>you have to use LAN cable with a diameter of 15 mm or less.<br>**----- End of picture text -----**<br> Drawing No. Rev. Page LR5-02WE-W18 B 6/8 ## **6.Outer Dimensions** **==> picture [472 x 621] intentionally omitted <==** **----- Start of picture text -----**<br> 6.1 [WE] Direct mounting<br>φ50 Unit:mm<br>|}<—>|<br>φ50<br>1<br>53.5<br>2<br>19<br>40 40<br>3 3<br>LR5-02WE : 99<br>LR5-102WE : 173.5<br>LR5-102WE : 139<br>LR5-202WE : 213.5<br>| | LR5-202WE : 179<br>LR5-302WE : 253.5<br>LR5-302WE : 219<br>LR5-402WE : 293.5<br>LR5-402WE : 259<br>LR5-502WE : 333.5<br>LR5-502WE : 299<br>4 4<br>80 80<br>5 5<br>12 12<br>6 6<br>7 7<br>RJ-45 ~_S Mounting dimensions<br>terminalot AN wy) Soe|<br> block “el as Ce<br>initialize —--L. +<br>Removed Direct Mount Bracket<br>Switch for | (oe $30<br>120° ASO ]<br>No. Name Material<br>1 Buzzer Unit PC(Off-white) Dame<br>2 Head Cover PC(Off-white) Namie (G20) Untimm)<br>3 Globe PC(Color based on LED unit)<br>4 Body PC(Off-white)<br>5 Direct Mount Bracket PC(Off-white)<br>6 Waterproof Packing Silicone Rubber<br>7 Mounting Bolt(M3) Steel<br>**----- End of picture text -----**<br> ※Maximum Board Thickness:7 |Drawing No.|Rev.|Page| |---|---|---| |LR5-02WE-W18|B|7/8| **==> picture [476 x 608] intentionally omitted <==** **----- Start of picture text -----**<br> 6.2 [LE] Mounting with pole/L-bracket,<br>φ50 Unit:mm<br>k—|<br>φ50<br>1 53.5 2<br>19<br>3 40 3 40<br>a :<br>LR5-02LE : 114<br>LR5-102LE : 188.5<br>LR5-102LE : 154<br>LR5-202LE : 228.5<br>LR5-202LE : 194<br>LR5-302LE : 268.5<br>LR5-302LE : 234<br>LR5-402LE : 308.5<br>LR5-402LE : 274<br>LR5-502LE : 348.5<br>LR5-502LE : 314<br>4 4<br>(20) (20)<br>5 5<br>φ21.7 φ21.7<br>6 6<br>( H—, (280 (). (280 terminal blockSwitch for . Raw/<br>initialize<br>9 9 Removed Pole Mount Bracket<br>(32)<br>8 8 (20)<br>7 80<br>7 u \<br>20 55<br>No. Name Material Mounting dimensions<br>12 Head CoverBuzzer Unit PC(OffPC(Off--white)white) Va L-bracket Outline<br>3 Globe PC(Color based on LED unit) 2-611 PT a<br>4 Body PC(Off-white)<br>5 Pole Bracket PC<br>6 Pole AL<br>|~e— + pe<br>7 Rubber Bushing EPR<br>8 L-bracket Steel (t=3)<br>9 Hexagon Nut M22 SUM<br>**----- End of picture text -----**<br> |Drawing No.|Rev.|Page| |---|---|---| |LR5-02WE-W18|B|8/8| ## **7.Buzzer Pattern Set-up** If your product is a model with a buzzer unit ( B ), you can set a buzzer sound and volume. To set them, you have to remove the buzzer unit and configure the DIP switches on its bottom.
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →