Image not available
Illustrative purposes only
LPT103-M
AC/DC Open Frame Power Supply (PSU), Medical, 3 Output, 130W @ 200LFM, 80 W, 90V AC to 264V AC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: ARTESYN / ADVANCED ENERGY
- Product type: AC / DC Open Frame Power Supplies
- No. of Outputs:3 Output; Power Rating (Covection Cooling):80W; Power Rating (Forced Cooling):130W @ 200LFM; Input Voltage VAC:90V AC to 264V AC; Power Supply Output Type:Adjustab
- SVHC: No SVHC (15-Jan-2018)
- Product Range: LPT100-M Series
- No. of Outputs: 3 Output
- Output Power Max: 80W
- Input Voltage VAC: 90V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 90V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 13A
- Output Current - Output 2: 4A
- Output Current - Output 3: 1A
- Output Current - Output 4: -
- Output Voltage - Output 1: 5VDC
- Output Voltage - Output 2: 15VDC
- Output Voltage - Output 3: -15VDC
- Output Voltage - Output 4: -
- Power Supply Applications: Medical
- Power Rating (Forced Cooling): 130W @ 200LFM
- Power Rating (Convection Cooling): 80W
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 86.73 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **ARTESYN LPT100-M SERiES** 130 Watts Advanced Energy's Artesyn LPT100-M series of triple output open-frame AC-DC power supplies features ITE and medical safety approvals. There is a choice of four models, covering output voltages from 3.3 V to 24 V. The power supplies have a typical full load power conversion efficiency of 82% and with a height of only 1.28 inches offer a power density in excess of 12 watts per cubic inch. LPT100-M power supplies are primarily designed for use in information technology equipment (ITE) and light industrial systems, as well as for equipment intended for non-patient contact and non-patient critical use in low power medical, dental and laboratory applications. - Thermal overload protection ## **SPEciAL FEATuRES** ## **Data Sheet** ## **Total Power:** **130 Watts** **input Voltage:** **90 - 264 Vac** **# of Outputs:** **Triple** - LPX100 enclosure kit available - Medical and ITE safeties - RoHS compliant - Active power factor correction - 2” x 4” footprint - Less than 1U high - EN61000-3-2 compliant - Remote sense - Power fail - Adjustable main output - Built-in Class B EMI filter - Overvoltage protection ## **SAFETY** > TUV 62368, 60601-1 > UL 62368, 60601-1 > CSA 62368, 60601-1 > NEMKO 62368, 60601-1 > AUSTEL 62368, 60601-1 > CB Certificate & report > CE Mark (LVD) - Overload protection ©2020 Advanced Energy Industries, Inc. **LPT100-M** **==> picture [479 x 318] intentionally omitted <==** **----- Start of picture text -----**<br> ELEcTRicAL SPEciFicATiONS<br>input<br>Input ra nge 90 - 264 Vac; 127 - 300 Vdc<br>Frequency 47 - 63 Hz<br>Inrush current 50 A max., cold start @ 25 °C<br>Efficiency 82% typical at full load<br>EMI/RFI FCC Class B conducted; CISPR22 Class B conducted;<br>EN55022 Class B conducted; VDE0878PT3 Class B conducted<br>Safety ground leakage current 275 µA @ 50/60 Hz, 264 Vac input<br>Output<br>Maximum power 130 W with 200 LFM forced air<br>Adjustment range All outputs adjustable: -20%, +10%, except for +24V output on LPT104-M which will be -10%, +20%<br>and 3.3 V output on the LPT101-M +10%, -15%<br>Hold-up time 10 ms @ 130 W load, 120 Vac input<br>Overload protection Short circuit protection on all outputs. Case overload protected @ 110 - 160% above rating for<br>V1 & V2, 150 - 250% for V3<br>Overvoltage protection 15 - 35% above nominal output<br>Logical control<br>Power failure Active LowTTL logic signal goes high 100 - 500 msec after main output; it goes low at least 6 msec<br>before loss of regulation<br>Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected.<br>Reverse connection protected.<br>**----- End of picture text -----**<br> **==> picture [479 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> ENViRONMENTAL SPEciFicATiONS<br>Operating temperature 0 °C to 50 °C ambient derate each output as 2.5% per degree from 50 °C to 70 °C. -20 °C start up<br>Storage temperature -40 °C to +85 °C<br>Electromagnetic susceptibility: Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3<br>Humidity Operating; non-condensing 10% to 90% RH, non-operating, non-condensing 10% - 95%<br>Vibration IEC68-2-6 to the levels of IEC721-3-2<br>MTBF calculated 583,000 hours at full load and 25 °C ambient conditions. 230 Vac input, Bellcore<br>**----- End of picture text -----**<br> **2 advancedenergy.com** **LPT100-M** ## **Mechanical Drawing** **==> picture [474 x 318] intentionally omitted <==** **----- Start of picture text -----**<br> ADJUST POT'S<br>S K3<br>OUTPUT VOLTAGE SEE DETAIL A<br>1<br>GND<br>S K2<br>PIN 1 (LIVE)<br>SK1<br>PIN 3 (NEUTRAL) 8<br> 0.16[4] 3.72 " 1 POWER FAIL<br>4 places mounting holemax screw head [94,6] 4 " C OMMON<br>( +) REMOTE SENSE<br>diameter 0.22"[5.6] [101,6]<br>( -) REMOTE SENSE<br>4<br>SK3<br>DETAIL A<br>"<br> 2 [50,8] 1.72 " [43,8]<br> 1.29" [32,7]<br>0.1 " [2,5] max lead protrusion 0.197 [5]min stand-offheight<br>**----- End of picture text -----**<br> **advancedenergy.com 3** **LPT100-M** ## **ORDERiNg iNFORMATiON** **==> picture [479 x 187] intentionally omitted <==** **----- Start of picture text -----**<br> Model Number Output Voltage Minimum Load Maximum Load with30cFM Forced Air Peak Load Regulation2 P/P (PARD)Ripple 3<br>+3.3 V 0 A 18 A 20 A ±2% 50 mV<br>LPT101-M +5 V 0 A 9 A 10 A ±5% 50 mV<br>+12 V 0 A 2.3 A 2.3 A ±5% 120 mV<br>+5 V 0 A 18 A 20 A ±2% 50 mV<br>LPT102-M +12 V 0 A 9 A 10 A ±5% 120 mV<br>-12 V 0 A 2 A 2 A ±5% 120 mV<br>+5 V 0 A 18 A 20 A ±2% 50 mV<br>LPT103-M +15 V 0 A 7.2 A 8 A ±5% 150 mV<br>-15 V 0 A 1.5 A 2 A ±5% 150 mV<br>+5 V 0 A 18 A 20 A ±2% 50 mV<br>LPT104-M +24 V 0 A 3 A 3.5 A ±7% 240 mV<br>+12 V 0 A 2.3 A 2.3 A ±5% 120 mV<br>**----- End of picture text -----**<br> 1. Peak current lasting < 15 seconds with a maximum 10% duty cycle. - 2 . At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. - 3 . Peak-to-peak with 20 mHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. 4. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is not intended for sale to End Users. **4 advancedenergy.com** **LPT100-M** ## **PiN ASSigNMENTS** **==> picture [479 x 216] intentionally omitted <==** **----- Start of picture text -----**<br> connector LPT100-M<br>SK1 PIN 1 Live<br>PIN 3 Neutral<br>SK2 PIN 1 V1out<br>PIN 2 V1out<br>PIN 3 GND<br>PIN 4 GND<br>PIN 5 GND<br>PIN 6 GND<br>PIN 7 V2out<br>PIN 8 V3out<br>SK3 PIN 1 Power Fail<br>PIN 2 GND<br>PIN 3 + Remote Sense<br>PIN 4 - Remote Sense<br>**----- End of picture text -----**<br> ## **MATiNg cONNEcTORS** |**Ac input (SK1)**|Molex 09-50-3031<br>PINS: 08-52-0072| |---|---| |**Ac ground**|Molex 01-90020001| |**Dc Output (SK2)**|JST VHR-8N<br>PINS: SVH-21T-P1.1| |**Remote Sense (SK3)**|JST PHR-4; PINS: SPH-002T-PO.5S<br>OR<br>LANDWIN 2001S0400; PINS: 2005T| |Artesyn Embedded Power Connector Kit #70-841-026, includes all of the above|| Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±.02”. 3. All mounting holes should be grounded for EMI purpose 4. Mounting M1 is safety ground connection 5. This power supply requires mounting on metal standoffs 0.20” (5 m) in height. 6. For DC input an external DC safety rated fuse must be used. 7. Warranty: 2 year 8. Weight: 0.44 lb. / 0.20 kg **advancedenergy.com 5** **==> picture [596 x 270] intentionally omitted <==** ## **ABOuT ADVANcED ENERgY** Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. Our products enable customer innovation in complex applications for a wide range of industries including semiconductor equipment, industrial, manufacturing, telecommunications, data center computing, and medical. With deep applications know-how and responsive service and support across the globe, we build collaborative partnerships to meet rapid technological developments, propel growth for our customers, and innovate the future of power. For international contact information, visit advancedenergy.com. powersales@aei.com (Sales Support) productsupport.ep@aei.com (Technical Support) +1 888 412 7832 Specifications are subject to change without notice. Not responsible for errors or omissions. ©2020 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, AE® and Artesyn™ are U.S. trademarks of Advanced Energy Industries, Inc. ENG-LPT100-M-235-01 12.30
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →