Image not available
Illustrative purposes only
LPQ201-M
AC/DC Open Frame Power Supply (PSU), Medical, 4 Output, 200W @ 30CFM, 100 W, 90V AC to 264V AC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: ARTESYN / ADVANCED ENERGY
- Product type: AC / DC Open Frame Power Supplies
- No. of Outputs:4 Output; Power Rating (Covection Cooling):100W; Power Rating (Forced Cooling):200W @ 30CFM; Input Voltage VAC:90V AC to 264V AC; Power Supply Output Type:Adjustab
- SVHC: No SVHC (15-Jan-2018)
- Product Range: LPQ200-M Series
- No. of Outputs: 4 Output
- Output Power Max: 100W
- Input Voltage VAC: 90V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 90V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 13A
- Output Current - Output 2: 13A
- Output Current - Output 3: 5A
- Output Current - Output 4: 2A
- Output Voltage - Output 1: 3.3VDC
- Output Voltage - Output 2: 5VDC
- Output Voltage - Output 3: 12VDC
- Output Voltage - Output 4: -12V
- Power Supply Applications: Medical
- Power Rating (Forced Cooling): 200W @ 30CFM
- Power Rating (Convection Cooling): 100W
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 89.6 € |
| Current stock | 25+ |
| Lead time | 30 days |
## **ARTESYN LPQ200-M SERIES** 200 Watts Advanced Energy’s Artesyn LPQ200-M series of open-frame AC-DC power supplies comprises two quad output models, one offering 3.3 V, 5 V, 12 V and -12 V outputs, the other offering 5 V, 12 V, 24 V and -12 V. Both models feature medical safety approvals and accept a universal input of 90—264 Vac or 120—300 Vdc. These compact switch-mode power supplies feature main output overvoltage protection and remote sense, with short-circuit protection on all outputs. Additional facilities include thermal overload protection and remote indication of power failure. LPQ200-M series power supplies provide 100 watts of output power with free air convection cooling and 200 watts with 30 CFM of forced air. Less than 1U high, they are suitable for a wide range of uses, including non-patient contact and non-patient critical medical applications. ## **SPECIAL FEATURES** ## **SAFETY** > Medical and ITE safeties TUV > Active power factor correction UL > 3” x 5” footprint CSA > Less than 1U high CB > EN61000-3-2 compliant CE 62368, 60601-1 62368, 60601-1 62368, 60601-1 Certificate & report Mark (LVD) ## **DATA SHEET** ## **Total Power:** **100 - 200 Watts** **Input Voltage:** **90 - 264 Vac** **# of Outputs:** **Quad** - Remote sense - Power fail - Adjustable outputs - Built-in Class B EMI filter - Overvoltage protection - Overload protection - Thermal overload protection - LPX200 enclosure kit available - RoHS compliant ©2020 Advanced Energy Industries, Inc. **LPQ200-M** **==> picture [479 x 319] intentionally omitted <==** **----- Start of picture text -----**<br> ELECTRICAL SPECIFICATIONS<br>Input<br>Input ra nge 90 - 264 Vac; 120 - 300 Vdc<br>Frequency 47 - 63 Hz<br>Inrush current 50 A max., cold start @ 25 °C, 230 Vac input<br>Efficiency 84% typical at full load<br>EMI/RFI FCC Class B conducted; CISPR22 Class B conducted;<br>EN55022 Class B conducted; VDE0878PT3 Class B conducted<br>Safety ground 275 μA @ 50/60 Hz, 264 Vac input<br>leakage current<br>Output<br>Maximum power 100 W for convection; 200 W with 30CFM forced air<br>Adjustment range All outputs -20%, +10%, except for the 3.3 V output which will be -15%, +10% (LPQ201-M)<br>Hold-up time 16 ms @ 200 W load, 120 Vac input<br>Overload protection Short circuit protection on all outputs. V1, V2 & V3 overload protected @ 110 - 160%. V4 is<br>150 - 250% above rating<br>Overvoltage protection 30 - 50% above nominal output on V1 (and V2 on LPQ201-M)<br>Logical Control<br>Power failure Active low logic signal goes high 100-500 msec after main output; it goes low at least 6<br>msec before loss of regulation<br>Remote sense Compensates for 0.4 V lead drop min. Will operate without remote sense connected. Reverse<br>connection protected.<br>**----- End of picture text -----**<br> ## **ENVIRONMENTAL SPECIFICATIONS** **==> picture [479 x 83] intentionally omitted <==** **----- Start of picture text -----**<br> Operating temperature 0 °C to 50 °C ambient derate each output as 2.5% per degree from 50 °C to 70 °C. -20 °C start up<br>Storage temperature -40 °C to +85 °C<br>Electromagnetic susceptibility Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3<br>Humidity Operating; non-condensing 10% to 90% RH, non-operating, non-condensing 10 - 95%<br>Vibration IEC68-2-6 to the levels of IEC721-3-2<br>MTBF calculated 516,000 hours at full load and 25 °C ambient conditions. 230 Vac input, Bellcore<br>**----- End of picture text -----**<br> **2 advancedenergy.com** **LPQ200-M** ## **ORDERING INFORMATION** **==> picture [479 x 143] intentionally omitted <==** **----- Start of picture text -----**<br> Maximum Load Maximum Load<br>NumberModel Output Voltage Minimum Load with Convection with 30CFM Peak Load Regulation2 Ripple P/P (PARD)3<br>Cooling Forced Air<br>+3.3 V 0 A 13 A 18 A 20 A ± 2% 50 mV<br>+5 V 0 A 13 A 18 A 20 A ± 2% 50 mV<br>LPQ201-M<br>+12 V 0 A 5 A 9 A 10 A ± 5% 120 mV<br>-12 V 0 A 1 A 2 A 2.5 A ± 5% 120 mV<br>+5 V 0 A 13 A 18 A 20 A ± 2% 50 mV<br>+12 V 0 A 5 A 9 A 10 A ± 5% 120 mV<br>LPQ202-M<br>+24 V 0 A 1.5 A 3 A 3.5 A ± 7% 240 mV<br>-12 V 0 A 1 A 2 A 2.3 A ± 5% 120 mV<br>**----- End of picture text -----**<br> 1. Peak current lasting < 30 seconds with a maximum 10% duty cycle. - 2 . At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. - 3 . Peak-to-peak with 20 MHz bandwidth and 10 μF (tantalum capacitor) in parallel with a 0.1 μF capacitor at rated line voltage and load ranges. 4. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is not intended for sale to End Users. ## **PIN ASSIGNMENTS** **==> picture [479 x 286] intentionally omitted <==** **----- Start of picture text -----**<br> Connector LPQ200-M<br>SK1 PIN 1 Neutral<br>PIN 3 Line<br>SK2 PIN 1 V1 OUT<br>PIN 2 V2 OUT<br>PIN 3 GND OUT<br>PIN 4 GND OUT<br>PIN 5 GND OUT<br>PIN 6 GND OUT<br>PIN 7 V3 OUT<br>PIN 8 V4 OUT<br>SK3 PIN 1 +V1 Remote sense<br>PIN 2 -V1 Remote sense<br>PIN 3 N/C<br>PIN 4 N/C<br>PIN 5 +Power fail<br>PIN 6 Common<br>PIN 7 N/C<br>PIN 8 Common<br>PIN 9 +V2 Remote Sense (LPQ201-M only)<br>PIN 10 -V2 Remote Sense (LPQ201-M only)<br>**----- End of picture text -----**<br> **advancedenergy.com 3** **LPQ200-M** ## **MATING CONNECTORS** **==> picture [479 x 128] intentionally omitted <==** **----- Start of picture text -----**<br> AC Input (SK1) Molex 09-50-3031 (connector)<br>PINS: 08-52-0072<br>AC Ground Molex 01-90020001<br>DC Output (SK2) Terminal block<br>Wire size based on Cable Ampacity/AWG<br>Control Signals (SK3) Molex 90142-0010 (USA)<br>PINS: 90119-2110 or<br>AMP: 87977-3<br>PINS: 87309-8<br>Astec connector kit #70-841-015, includes all of above<br>**----- End of picture text -----**<br> 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ± 0.02” (± 0.5 mm) 3. Mounting holes MH1 and MH2 should be grounded for EMI purposes. 4. Mounting hole MH1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 Vac input, 25 °C unless otherwise stated. 6. This power supply requires mounting on metal standoffs 0.20” (5 m) in height. 7. Warranty: 2 years 8. Weight: 1.5 lbs/0.68 kg **4 advancedenergy.com** **LPQ200-M** ## **MECHANICAL DRAWING** **==> picture [353 x 367] intentionally omitted <==** **----- Start of picture text -----**<br> 3.00 (76.2)<br>0.224 (5.7) (4X) 2.55 (64.8)<br>J<br>:y =1 O}Ot ar<br>9 | Ph eT Ke, [I Hl<br>oes ene ee<br>0.06 (1.5) (2X)<br>0.098 (2.5)<br>PTE 0.472 (12)<br>1.32 (33.6) max<br>0.224 (5.7) (4X) PIN - 5 SK3 PIN - 10 PIN - 1 V3 Pot Adj SK2 PIN -8 Ø4 (4X)Mounting Hole V4 Adjust POT<br>Output VoltageAdjust POTs<br>V2 Pot Adj.<br>V1 Pot Adj<br>5.00 (127) 4.55 (115.6)<br>100W<br>MH1 Saety Gnd<br>PIN - 1 SK 1 PIN - 3<br>Ground Tab<br>**----- End of picture text -----**<br> **advancedenergy.com 5** **==> picture [596 x 270] intentionally omitted <==** ## **ABOUT ADVANCED ENERGY** Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. Our products enable customer innovation in complex applications for a wide range of industries including semiconductor equipment, industrial, manufacturing, telecommunications, data center computing, and medical. With deep applications know-how and responsive service and support across the globe, we build collaborative partnerships to meet rapid technological developments, propel growth for our customers, and innovate the future of power. For international contact information, visit advancedenergy.com. powersales@aei.com (Sales Support) productsupport.ep@aei.com (Technical Support) +1 888 412 7832 Specifications are subject to change without notice. Not responsible for errors or omissions. ©2020 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, AE® and Artesyn™ are U.S. trademarks of Advanced Energy Industries, Inc. ENG-LPQ200-M-235-01 12.28
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →