Image not available
Illustrative purposes only
LPF-90D-15
LED Driver, LED Lighting, 75 W, 15 VDC, 5 A, Constant Current, 90 V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: LPF-90D
- Output Current: 5A
- LED Driver Mode: Constant Current
- Output Power Max: 75W
- Input Voltage Max: 305V
- Input Voltage Min: 90V
- Output Voltage Max: 15VDC
- Power Supply Applications: LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 26.66 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- LPF 90D series** eE_e| 90W Constant Current Mode LED Driver ## ** ** V VV > ** IP67 ** V VV CD Kos Ads ( ~~4~~ ) | FAL CBCE@ ## ■ **** ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ ## ■ **** ~ ℃℃ ## ■ **** ## ** ** _File Name:LPF-90D-SPEC 2020-10-13_ 90W Constant Current Mode LED Driver ## **- LPF 90D series** ## **SPECIFICATION** |**MODEL**<br>**OUTPUT**<br>**VOLTAGE RANGENote.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**EMC IMMUNITY**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER TEMPERATURE**<br>**OVER VOLTAGE**<br>47 ~ 63Hz<br><0.75mA / 240VAC<br>Compliance to EN55015,EN61000-3-2 Class C (@load≧60%) ; EN61000-3-3,GB17743 and GB17625.1,EAC TP TC 020<br>20 ~ 95% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>1036.4K hrs min. Telcordia SR-332 (Bellcore) ;267.2Khrs min. MIL-HDBK-217F (25℃)<br>**ENVIRONMENT**<br>**EMC EMISSIONNote.8**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>I/P-O/P:3.75KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**TOTAL HARMONIC DISTORTION**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RATED POWERNote.5**<br>**SETUP, RISE TIMENote.6**<br>**HOLD UP TIME (Typ.)**<br>**CONSTANT CURRENT REGIONNote.2**<br>**OVER CURRENT**<br>**SAFETY STANDARDSNote.8**<br>COLD START 70A(twidth=435 s measured at 50% Ipeak) at 230VAC<br>μ<br>;Per NEMA 410<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC<br>**MAX. CASE TEMP.**<br>Tcase=+70℃<br>Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Line 2KV),EAC TP TC 020<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>90 ~ 305VAC 127 ~ 431VDC<br>℃<br><br><br><br><br><br><br><br><br> <br>℃<br><br>℃℃<br><br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf<br>※ : , https://www.meanwell.com/serviceDisclaimer.aspx<br>95 ~ 108%<br>Constant current limiting, recovers automatically after fault condition is removed<br>PF≧0.97/115VAC, PF≧0.96/230VAC, PF≧0.95/277VAC@full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>THD< 20%(@load≧60%/115VC,230VAC; @load≧75%/277VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>Tcase=-40 ~ +70℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>Shut down o/p voltage, re-power on to recover<br>15V<br>**LPF-90D-15**<br>**LPF-90D-20**<br>**LPF-90D-24**<br>**LPF-90D-30**<br>**LPF-90D-36**<br>**LPF-90D-42**<br>**LPF-90D-48**<br>**LPF-90D-54**<br>20V<br>24V<br>30V<br>36V<br>48V<br>5A<br>4.5A<br>3.75A<br>3A<br>2.5A<br>1.88A<br>75W<br>90W<br>90W<br>90W<br>90W<br>90.24W<br>54V<br>1.67A<br>90.18W<br>42V<br>2.15A<br>90.3W<br>9 ~ 15V<br>12 ~ 20V<br>14.4 ~ 24V<br>18 ~ 30V<br>21.6 ~ 36V<br>28.8 ~ 48V<br>32.4 ~ 54V<br>25.2 ~ 42V<br>16ms/230VAC 16ms/115VAC<br>1200ms, 200ms / 115VAC 500ms, 200ms / 230VAC<br>0.95A / 115VAC 0.5A / 230VAC 0.4A / 277VAC<br>18 ~ 21V<br>23 ~ 27V<br>28 ~ 34V<br>34 ~ 38V<br>41 ~ 46V<br>54 ~ 60V<br>47 ~ 53V<br>59 ~ 65V<br>Shut down o/p voltage, re-power on to recover<br>UL8750(type”HL”), CSA C22.2 No.250.13-12, TUV EN61347-1, EN61347-2-13, EAC TP TC 004,<br>GB19510.1,GB19510.14,IP67 approved ; Design refer to UL60950-1, TUV EN60950-1<br>161*61*36mm (L*W*H)<br>0.7Kg;20pcs/15Kg/0.73CUFT<br>**CURRENT TOLERANCE**<br>**CURRENT RIPPLE**<br>±5.0%<br>5.0% max. @rated current<br>89%<br>89.5%<br>90%<br>90.5%<br>90.5%<br>90.5%<br>90.5%<br>90.5%|**MODEL**<br>**OUTPUT**<br>**VOLTAGE RANGENote.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**EMC IMMUNITY**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER TEMPERATURE**<br>**OVER VOLTAGE**<br>47 ~ 63Hz<br><0.75mA / 240VAC<br>Compliance to EN55015,EN61000-3-2 Class C (@load≧60%) ; EN61000-3-3,GB17743 and GB17625.1,EAC TP TC 020<br>20 ~ 95% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>1036.4K hrs min. Telcordia SR-332 (Bellcore) ;267.2Khrs min. MIL-HDBK-217F (25℃)<br>**ENVIRONMENT**<br>**EMC EMISSIONNote.8**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>I/P-O/P:3.75KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**TOTAL HARMONIC DISTORTION**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RATED POWERNote.5**<br>**SETUP, RISE TIMENote.6**<br>**HOLD UP TIME (Typ.)**<br>**CONSTANT CURRENT REGIONNote.2**<br>**OVER CURRENT**<br>**SAFETY STANDARDSNote.8**<br>COLD START 70A(twidth=435 s measured at 50% Ipeak) at 230VAC<br>μ<br>;Per NEMA 410<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC<br>**MAX. CASE TEMP.**<br>Tcase=+70℃<br>Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Line 2KV),EAC TP TC 020<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>90 ~ 305VAC 127 ~ 431VDC<br>℃<br><br><br><br><br><br><br><br><br> <br>℃<br><br>℃℃<br><br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf<br>※ : , https://www.meanwell.com/serviceDisclaimer.aspx<br>95 ~ 108%<br>Constant current limiting, recovers automatically after fault condition is removed<br>PF≧0.97/115VAC, PF≧0.96/230VAC, PF≧0.95/277VAC@full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>THD< 20%(@load≧60%/115VC,230VAC; @load≧75%/277VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>Tcase=-40 ~ +70℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>Shut down o/p voltage, re-power on to recover<br>15V<br>**LPF-90D-15**<br>**LPF-90D-20**<br>**LPF-90D-24**<br>**LPF-90D-30**<br>**LPF-90D-36**<br>**LPF-90D-42**<br>**LPF-90D-48**<br>**LPF-90D-54**<br>20V<br>24V<br>30V<br>36V<br>48V<br>5A<br>4.5A<br>3.75A<br>3A<br>2.5A<br>1.88A<br>75W<br>90W<br>90W<br>90W<br>90W<br>90.24W<br>54V<br>1.67A<br>90.18W<br>42V<br>2.15A<br>90.3W<br>9 ~ 15V<br>12 ~ 20V<br>14.4 ~ 24V<br>18 ~ 30V<br>21.6 ~ 36V<br>28.8 ~ 48V<br>32.4 ~ 54V<br>25.2 ~ 42V<br>16ms/230VAC 16ms/115VAC<br>1200ms, 200ms / 115VAC 500ms, 200ms / 230VAC<br>0.95A / 115VAC 0.5A / 230VAC 0.4A / 277VAC<br>18 ~ 21V<br>23 ~ 27V<br>28 ~ 34V<br>34 ~ 38V<br>41 ~ 46V<br>54 ~ 60V<br>47 ~ 53V<br>59 ~ 65V<br>Shut down o/p voltage, re-power on to recover<br>UL8750(type”HL”), CSA C22.2 No.250.13-12, TUV EN61347-1, EN61347-2-13, EAC TP TC 004,<br>GB19510.1,GB19510.14,IP67 approved ; Design refer to UL60950-1, TUV EN60950-1<br>161*61*36mm (L*W*H)<br>0.7Kg;20pcs/15Kg/0.73CUFT<br>**CURRENT TOLERANCE**<br>**CURRENT RIPPLE**<br>±5.0%<br>5.0% max. @rated current<br>89%<br>89.5%<br>90%<br>90.5%<br>90.5%<br>90.5%<br>90.5%<br>90.5%|**LPF-90D-15**|**LPF-90D-20**|**LPF-90D-24**|**LPF-90D-30**|**LPF-90D-36**|**LPF-90D-42**|**LPF-90D-48**|**LPF-90D-54**| |---|---|---|---|---|---|---|---|---|---| ||**DC VOLTAGE**|15V|20V|24V|30V|36V|42V|48V|54V| ||**RATED CURRENT**|5A|4.5A|3.75A|3A|2.5A|2.15A|1.88A|1.67A| ||**RATED POWERNote.5**|75W|90W|90W|90W|90W|90.3W|90.24W|90.18W| ||**CONSTANT CURRENT REGIONNote.2**|9 ~ 15V|12 ~ 20V|14.4 ~ 24V|18 ~ 30V|21.6 ~ 36V|25.2 ~ 42V|28.8 ~ 48V|32.4 ~ 54V| ||**CURRENT RIPPLE**|5.0% max. @rated current|||||||| ||**CURRENT TOLERANCE**|±5.0%|||||||| ||**SETUP, RISE TIMENote.6**|1200ms, 200ms / 115VAC 500ms, 200ms / 230VAC|||||||| ||**HOLD UP TIME (Typ.)**|16ms/230VAC 16ms/115VAC|||||||| ||**VOLTAGE RANGENote.5**|(Please refer to "STATIC CHARACTERISTIC" section)<br>90 ~ 305VAC 127 ~ 431VDC|||||||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||||||| ||**POWER FACTOR**|PF≧0.97/115VAC, PF≧0.96/230VAC, PF≧0.95/277VAC@full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)|||||||| ||**TOTAL HARMONIC DISTORTION**|THD< 20%(@load≧60%/115VC,230VAC; @load≧75%/277VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)|||||||| ||**EFFICIENCY (Typ.)**|89%|89.5%|90%|90.5%|90.5%|90.5%|90.5%|90.5%| ||**AC CURRENT**|0.95A / 115VAC 0.5A / 230VAC 0.4A / 277VAC|||||||| ||**INRUSH CURRENT(Typ.)**|COLD START 70A(twidth=435 s measured at 50% Ipeak) at 230VAC<br>μ<br>;Per NEMA 410|||||||| ||**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**|4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC|||||||| ||**LEAKAGE CURRENT**|<0.75mA / 240VAC|||||||| ||**OVER CURRENT**|95 ~ 108%<br>Constant current limiting, recovers automatically after fault condition is removed|||||||| ||**OVER VOLTAGE**|18 ~ 21V<br>23 ~ 27V<br>28 ~ 34V<br>34 ~ 38V<br>41 ~ 46V<br>54 ~ 60V<br>47 ~ 53V<br>59 ~ 65V<br>Shut down o/p voltage, re-power on to recover|||||||| ||**OVER TEMPERATURE**|Shut down o/p voltage, re-power on to recover|||||||| ||**WORKING TEMP.**|Tcase=-40 ~ +70℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)|||||||| ||**MAX. CASE TEMP.**|Tcase=+70℃|||||||| ||**WORKING HUMIDITY**|20 ~ 95% RH non-condensing|||||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +80℃, 10 ~ 95% RH|||||||| ||**TEMP. COEFFICIENT**|±0.03%/℃(0 ~ 50℃)|||||||| ||**VIBRATION**|10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes|||||||| ||**SAFETY STANDARDSNote.8**|UL8750(type”HL”), CSA C22.2 No.250.13-12, TUV EN61347-1, EN61347-2-13, EAC TP TC 004,<br>GB19510.1,GB19510.14,IP67 approved ; Design refer to UL60950-1, TUV EN60950-1|||||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC|||||||| ||**ISOLATION RESISTANCE**|I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH|||||||| ||**EMC EMISSIONNote.8**|Compliance to EN55015,EN61000-3-2 Class C (@load≧60%) ; EN61000-3-3,GB17743 and GB17625.1,EAC TP TC 020|||||||| ||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Line 2KV),EAC TP TC 020|||||||| ||**MTBF**|1036.4K hrs min. Telcordia SR-332 (Bellcore) ;267.2Khrs min. MIL-HDBK-217F (25℃)|||||||| ||**DIMENSION**|161*61*36mm (L*W*H)|||||||| ||**PACKING**<br>℃<br><br><br><br><br><br><br><br><br> <br>℃<br><br>℃℃<br><br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf<br>※ : , https://www.meanwell.com/serviceDisclaimer.aspx<br>0.7Kg;20pcs/15Kg/0.73CUFT||||||||| _File Name:LPF-90D-SPEC 2020-10-13_ **- LPF 90D series** 90W Constant Current Mode LED Driver ## **BLOCK DIAGRAM** **==> picture [468 x 139] intentionally omitted <==** **----- Start of picture text -----**<br> fosc : 100KHz<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P & CIRCUIT SWITCHING & -V<br>RECTIFIERS FILTER<br>DIM+<br>O.L.P.<br>DIM-<br>O.T.P. O.L.P. DETECTION<br>PWM & PFC CIRCUIT<br>CONTROL<br>O.V.P.<br>**----- End of picture text -----**<br> ## **DRIVING METHODS OF LED MODULE** ※ This series works in constant current mode to directly drive the LEDs. **==> picture [219 x 150] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>Constant<br>Current area<br>60<br>(min.)<br>Hiccup<br>Protection<br>50 100 Io(%)<br>Typical output current normalized by rated current (%)<br>Vo(%)<br>**----- End of picture text -----**<br> In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Should there be any compatibility issues, please contact MEAN WELL. _File Name:LPF-90D-SPEC 2020-10-13_ **- LPF 90D series** 90W Constant Current Mode LED Driver ## **DIMMING OPERATION** **==> picture [501 x 136] intentionally omitted <==** **----- Start of picture text -----**<br> ※ 3 in 1 dimming function<br>AC/L(Brown)<br>AC/N(Blue) LPF-90D +V(Red)<br>-V(Black)<br>DIM+(Blue)<br>DIM-(White)<br>‧Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-:<br> 1 ~ 10VDC, or 10V PWM signal or resistance.<br>**----- End of picture text -----**<br> **==> picture [295 x 154] intentionally omitted <==** **----- Start of picture text -----**<br> ‧Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.<br>‧Dimming source current from power supply: 100μA (typ.)<br>◎ Applying additive 1 ~ 10VDC<br>+<br>+V +<br>-<br>-V -<br>DIM+<br>+<br>Additive Voltage<br>-<br>DIM-<br>“DO NOT connect "DIM- to -V"<br>Output current (%)<br>**----- End of picture text -----**<br> **==> picture [162 x 469] intentionally omitted <==** **----- Start of picture text -----**<br> 100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>1V 2V 3V 4V 5V 6V 7V 8V 9V 10V<br>Dimming input: Additive voltage<br>100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>Duty cycle of additive 10V PWM signal dimming input<br>100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N<br>(N=driver quantity for synchronized dimming operation)<br>Dimming input: Additive resistance<br>Output current (%)<br>Output current (%)<br>Output current (%)<br>**----- End of picture text -----**<br> **==> picture [227 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> ◎ Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz):<br>+<br>+V +<br>-<br>-V -<br>DIM+<br>Additive PWM signal<br>DIM-<br>“DO NOT connect "DIM- to -V"<br>**----- End of picture text -----**<br> **==> picture [224 x 125] intentionally omitted <==** **----- Start of picture text -----**<br> ◎ Applying additive resistance:<br>+<br>+V +<br>-<br>-V -<br>DIM+<br>Additive Resistance<br>DIM-<br>“DO NOT connect "DIM- to -V"<br>**----- End of picture text -----**<br> _File Name:LPF-90D-SPEC 2020-10-13_ **- LPF 90D series** ## 90W Constant Current Mode LED Driver **==> picture [455 x 182] intentionally omitted <==** **----- Start of picture text -----**<br> Note: In the case of turning the lighting fixture down to 0% brightness, please refer to the configuration as follow, or please contact MEAN WELL<br>for other options.<br>N L<br>Relay Switch Adjuster<br>10K/N~100K/N Ohms resistance<br>1~10V DC Voltage<br>10V PWM Signal<br>Blue<br>DIM+<br>White<br>DIM-<br>AC/L Black<br>Brown AC/N LPF-90D V(-)V(+) Red LED Lighting Fixture<br>Blue<br>**----- End of picture text -----**<br> Using a switch and relay can turn ON/OFF the lighting fixture. _File Name:LPF-90D-SPEC 2020-10-13_ **- LPF 90D series** 90W Constant Current Mode LED Driver **==> picture [499 x 415] intentionally omitted <==** **----- Start of picture text -----**<br> OUTPUT LOAD vs TEMPERATURE<br>100 100<br>80 80<br>230VAC 230VAC<br>Input only Input only<br>60 60<br>40 40<br>20 20<br>-40 -25 -10 0 15 30 50 60 70 (HORIZONTAL) -40 -25 -15 0 15 30 50 60 70 (HORIZONTAL)<br>AMBIENT TEMPERATURE,Ta ( ℃ ) Tcase ( ℃ )<br>STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC<br>※ Tcase at 60℃<br>100<br>90<br>1<br>80 0.9<br>0.8<br>70 0.7<br>0.6<br>60<br>0.5 115VAC<br>50 0.4 230VAC<br>0.3<br>40 0.2 277VAC<br>0.1<br>0<br>90 100 125 135 145 155 165 175 180 200 230 305<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>INPUT VOLTAGE (V) 60Hz (90W)<br>※De-rating is needed under low input voltage.<br>LOAD (%) LOAD (%)<br>PF<br>LOAD (%)<br>**----- End of picture text -----**<br> **==> picture [19 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> LOAD<br>**----- End of picture text -----**<br> ## **TOTAL HARMONIC DISTORTION (THD)** **==> picture [239 x 159] intentionally omitted <==** **----- Start of picture text -----**<br> ※ 48V Model, Tcase at 60℃<br>25<br>20<br>15<br>115VAC<br>10<br>230VAC<br>5 277VAC<br>0<br>50% 60% 70% 80% 90% 100%<br>LOAD<br>THD<br>**----- End of picture text -----**<br> ## **EFFICIENCY vs LOAD** **==> picture [235 x 181] intentionally omitted <==** **----- Start of picture text -----**<br> LPF-90D series possess superior working efficiency that up to 90.5% can<br>be reached in field applications.<br>※ 48V Model, Tcase at 60℃<br>92<br>91<br>90<br>89<br>88<br>87<br>86<br>85 277VAC<br>84 230VAC<br>83 115VAC<br>82<br>81<br>80<br>79<br>78<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>LOAD<br>EFFICIENCY(%)<br>**----- End of picture text -----**<br> _File Name:LPF-90D-SPEC 2020-10-13_ **- LPF 90D series** 90W Constant Current Mode LED Driver ## **LIFE TIME** **==> picture [351 x 167] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100<br>80<br>60<br>40<br>20<br>0<br>25 30 35 40 45 50 55 60 65 70<br>LIFETIME(Kh)<br>**----- End of picture text -----**<br> Tcase (℃ ) _File Name:LPF-90D-SPEC 2020-10-13_ **- LPF 90D series** ## 90W Constant Current Mode LED Driver **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> MECHANICAL SPECIFICATION<br>CASE NO.: LPF-90A Unit:mm<br>161<br>4<br>300±20<br>300±20<br>AC/L(Brown)<br>AC/N(Blue) +V(Red)<br>SJOW 17AWG×2C & H05RN-F 2×1.0mm 2 -V(Black)DIM+(Blue)<br>91 Style 2464 18AWG×4C DIM-(White)<br>tc<br>4<br>‧ : Max. Case Temperaturetc<br>Recommend Mounting Direction<br>INSTALLATION MANUAL<br>Please refer to:http://www.meanwell.com/manual.html<br>4.5<br>ψ<br>4.5<br>ψ<br>4<br>61<br>4 9<br>36<br>**----- End of picture text -----**<br> _File Name:LPF-90D-SPEC 2020-10-13_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →