Image not available
Illustrative purposes only
LOP-500-48
AC/DC Open Frame Power Supply (PSU), ITE, Industrial, Household, Medical, 1 Output, 321.6 W
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Open Frame Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: LOP-500 Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 80V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 10.4A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 48V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Industrial, Household, Medical
- Power Rating (Convection Cooling): 321.6W
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 51.5 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- LOP 500 series** 500W 5"×3" Low Profile Open Frame Power Supply **==> picture [42 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> User’s Manual<br>**----- End of picture text -----**<br> **==> picture [481 x 46] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>PWu t www.ID 2000000000tuv. com CBS OMCCKAASOE<br>UL62368-1 BS EN/EN62368-1 IEC62368-1 AS/NZS 61558-1/-2-16 GB4943.1 TPTC004<br>ANSI/AAMI ES60601-1 BS EN/EN60335-1 IEC60335-1<br>BS EN/EN61558-1/-2-16BS EN/EN60601 - 1 IEC61558-1/-2-16IEC60601 - 1 + +<br>**----- End of picture text -----**<br> **==> picture [113 x 43] intentionally omitted <==** **----- Start of picture text -----**<br> + +<br>oe Lf La<br>■ <br>**----- End of picture text -----**<br> ## ■ **** - ‧ - ‧ - - ‧× - ‧ - ‧ - ‧ - ‧ - ‧ - - - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ Ⅰ Ⅱ ‧Ⅲ Ⅲ - ‧ - ‧ - ‧℃ - ‧ - ‧ - ‧ - ‧ - ‧ ## ■ **** https://www.meanwell.com/serviceGTIN.aspx - ‧ - ‧ ## ■ **** μ ■ ** ** ~~PT~~ _File Name:LOP-500-SPEC 2024-01-05_ **LOP - 500 series** 500W 5"×3" Low Profile Open Frame Power Supply ## **SPECIFICATION** ||**MODEL**<br>**DC VOLTAGE**<br>**CURRENT**<br>**Peak(3sec.)**<br>**Convection**<br>**Convection**<br>**RATED**<br>**POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**VOLTAGE ADJ. RANGE(MAIN OUTPUT)**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME(Typ.)**<br>**VOLTAGE RANGE Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY(Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**OVER TEMPERATURE**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT(Typ.)**<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**Peak(3sec.)**<br>**FUNCTION**<br>**EXTERNAL FAN SUPPLY**<br>**REMOTE SENSE**<br>**POWER GOOD / POWER FAIL**<br>**(optional)**<br>**23CFM**<br>**23CFM**<br>**LEAKAGE CURRENT**|**MODEL**<br>**DC VOLTAGE**<br>**CURRENT**<br>**Peak(3sec.)**<br>**Convection**<br>**Convection**<br>**RATED**<br>**POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**VOLTAGE ADJ. RANGE(MAIN OUTPUT)**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME(Typ.)**<br>**VOLTAGE RANGE Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY(Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**OVER TEMPERATURE**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT(Typ.)**<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**Peak(3sec.)**<br>**FUNCTION**<br>**EXTERNAL FAN SUPPLY**<br>**REMOTE SENSE**<br>**POWER GOOD / POWER FAIL**<br>**(optional)**<br>**23CFM**<br>**23CFM**<br>**LEAKAGE CURRENT**|**MODEL**<br>**DC VOLTAGE**<br>**CURRENT**<br>**Peak(3sec.)**<br>**Convection**<br>**Convection**<br>**RATED**<br>**POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**VOLTAGE ADJ. RANGE(MAIN OUTPUT)**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME(Typ.)**<br>**VOLTAGE RANGE Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY(Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**OVER TEMPERATURE**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT(Typ.)**<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**Peak(3sec.)**<br>**FUNCTION**<br>**EXTERNAL FAN SUPPLY**<br>**REMOTE SENSE**<br>**POWER GOOD / POWER FAIL**<br>**(optional)**<br>**23CFM**<br>**23CFM**<br>**LEAKAGE CURRENT**|**LOP-500-12**|**LOP-500-15**|**LOP-500-18**|**LOP-500-24 **|**LOP-500-27 **|**LOP-500-36 **|**LOP-500-48**|**LOP-500-54**| |---|---|---|---|---|---|---|---|---|---|---|---| |||**DC VOLTAGE**||12V|15V|18V|24V|27V|36V|48V|54V| |||**CURRENT**<br>**Peak(3sec.)**<br>**Convection**<br>**Convection**<br>**RATED**<br>**POWER**<br>**RIPPLE & NOISE (max.)Note.2**<br>**Peak(3sec.)**<br>**23CFM**<br>**23CFM**|**Peak(3sec.)**|62.5A|50A|41.7A|31.3A|27.8A|20.8A|15.6A|13.9A| ||||**23CFM**|41.6A|33.3A|27.8A|20.9A|18.5A|13.9A|10.4A|9.3A| ||||**Convection**|25A|20A|16.7A|13.4A|11.9A|8.9A|6.7A|6A| ||||**Peak(3sec.)**|750W|750W|750.6W|751.2W|750.6W|748.8W|748.8W|750.6W| ||||**23CFM**|499.2W|499.5W|500.4W|501.6W|499.5W|500.4W|499.2W|502.2W| ||||**Convection**|300W|300W|300.6W|321.6W|321.3W|320.4W|321.6W|324W| |||||120mVp-p|150mVp-p|180mVp-p|200mVp-p|200mVp-p|250mVp-p|250mVp-p|250mVp-p| |||**VOLTAGE ADJ. RANGE(MAIN OUTPUT)**||11.4~12.6V|14.3~15.8V|17.1~18.9V|22.8~25.2V|25.6 ~ 28.4V|34.2 ~37.8V|45.6 ~50.4V|52 ~58V| |||**VOLTAGE TOLERANCENote.3**||±3.0%|±3.0%|±3.0%|±2.0%|±1.0%|±1.0%|±1.0%|±1.0%| |||**LINE REGULATION**||±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%| |||**LOAD REGULATION**||±1.0%|±1.0%|±1.0%|±1.0%|±1.0%|±1.0%|±1.0%|±1.0%| |||**SETUP, RISE TIME**||1000ms, 30ms/230VAC 1500ms, 30ms/115VAC at full load|||||||| |||**HOLD UP TIME(Typ.)**||26ms<br>300W load , 16ms<br>500W load<br>@<br>@|||||||| |||**VOLTAGE RANGE Note.4**||80 ~ 264VAC 113 ~ 370VDC|||||||| |||**FREQUENCY RANGE**||47 ~ 63Hz|||||||| |||**POWER FACTOR**||PF>0.95/230VAC PF>0.98/115VAC at full load|||||||| |||**EFFICIENCY(Typ.)**||93.5%|94.5%|94.5%|94.5%|95%|95%|95%|95%| |||**AC CURRENT(Typ.)**||5.2A/115VAC 2.9A/230VAC|||||||| |||**INRUSH CURRENT(Typ.)**||COLD START 40A/115VAC 80A/230VAC|||||||| |||**LEAKAGE CURRENT**||Earth leakage current<br>, touch current<br>< 500 A<br>< 70 A<br>(rms) @ 264VAC<br>(rms) @ 264VAC<br>μ<br>μ|||||||| |||**OVERLOAD**||105 ~ 150% rated output power,<br>Protection type : Hiccup after 3 sec, recovers automatically<br>after fault condition is removed|||||||| |||**OVER VOLTAGE**||16.5 ~ 19.5V<br>29.7 ~ 35.1V 39.6 ~ 46.8V<br>13.2 ~ 15.6V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>52.8 ~ 62.4V<br>26.4 ~ 31.2V<br>19.8 ~ 23.4V<br>59.4 ~ 67.5V|||||||| |||**OVER TEMPERATURE**||Protection type :Shut down o/p voltage, recovers automatically after temperature goes down or re-power on to recover|||||||| |||**EXTERNAL FAN SUPPLY**||12V@0.5A for driving a fan / 12V@0.2A for without fan ;<br>Tolerance -15% ~+15% at main output 20% rated current<br>(23CFM)|||||||| |||**REMOTE SENSE**||The remote sensing compensates voltage drop on the load wiring up to 0.5V|||||||| |||**POWER GOOD / POWER FAIL**<br>**(optional)**||500ms>PG>10ms ; The TTL signal goes high with 10ms to 500ms delay after power set up ;<br>The TTL signal goes low at least 1ms before Vo below 90% of rated value; TTL(0 ~ 1V), TTH(2 ~ 5V)|||||||| |||**WORKING TEMP.**||-40 ~ +80℃(Refer to "Derating Curve")|||||||| |||**WORKING HUMIDITY**||20 ~ 90% RH non-condensing|||||||| |||**STORAGE TEMP., HUMIDITY**||-40 ~ +85℃, 10 ~ 95% RH non-condensing|||||||| |||**TEMP. COEFFICIENT**||±0.03%/℃(0 ~ 50℃)|||||||| |||**VIBRATION**||10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes|||||||| _File Name:LOP-500-SPEC 2024-01-05_ **LOP - 500 series** 500W 5"×3" Low Profile Open Frame Power Supply ||**SAFETY &**<br>**EMC**<br>**(Note 5)**<br>**OTHERS**<br>**NOTE**|**SAFETY STANDARDS**|CB IEC62368-1, IEC60335-1, IEC61558-1/-2-16, IEC60601-1;<br>TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16, BS EN/EN60601-1<br>;<br>(3.2 Version)<br>UL UL62368-1,<br>;<br>ANSI / AAMI ES60601-1(3.2 Version)<br>CCC GB4943.1 ; RCM AS/NZS 61558-1/-2-16; EAC TPTC 004 approved.|CB IEC62368-1, IEC60335-1, IEC61558-1/-2-16, IEC60601-1;<br>TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16, BS EN/EN60601-1<br>;<br>(3.2 Version)<br>UL UL62368-1,<br>;<br>ANSI / AAMI ES60601-1(3.2 Version)<br>CCC GB4943.1 ; RCM AS/NZS 61558-1/-2-16; EAC TPTC 004 approved.|CB IEC62368-1, IEC60335-1, IEC61558-1/-2-16, IEC60601-1;<br>TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16, BS EN/EN60601-1<br>;<br>(3.2 Version)<br>UL UL62368-1,<br>;<br>ANSI / AAMI ES60601-1(3.2 Version)<br>CCC GB4943.1 ; RCM AS/NZS 61558-1/-2-16; EAC TPTC 004 approved.| |---|---|---|---|---|---| |||**OVER VOLTAGE CATEGORY**|IEC/EN 61558-1/-2-16(<br>altitude up to 2000M )<br>OVCⅢ,<br>IEC/EN/UL 62368-1 (OVCⅡ, altitude up to 5000M )<br>IEC/EN 60335-1 (OVCⅡ, altitude up to 5000M )<br>IEC/EN 60601-1 (OVCⅡ, altitude up to 4000M )||| |||**PROTECTIVE EXTRA-**<br>**LOW VOLTAGE**|IEC/EN61558-2-16 (SELV, 12~48V )<br>IEC/EN/UL 62368-1 (SELV / ES1, 12~48V )||| |||**WITHSTAND VOLTAGE**|I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC||| |||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG<br>:100M Ohms / 500VDC / 25℃/ 70% RH<br>, O/P-FG||| |||**EMC IMMUNITY**<br>**EMC EMISSION**<br>**MTBF**|**Parameter**<br>Conducted & Radiated|**Standard**|**Test Level / Note**| |||||BS EN/EN55032(CISPR32)|ClassⅠClass B , ClassⅡ: Class A<br>:| |||||BS EN/EN55014(CISPR32)|ClassⅠClass B<br>:| ||||Harmonic Current|BS EN/EN61000-3-2|Class A| ||||Voltage Flicker|BS EN/EN61000-3-3|-------| ||||EN61000-6-2<br>BS EN/EN55035,BS EN/||| ||||**Parameter**|**Standard**|**Test Level /Note**| ||||ESD|BS EN/EN61000-4-2|Level 4, 15KV air ; Level 4, 8KV contact| ||||Radiated Susceptibility|BS EN/EN61000-4-3|Level 3, 10V/m( 80MHz~2.7GHz )<br>Table 9, 9~28V/m( 385MHz~5.78GHz )| ||||EFT/Burest|BS EN/EN61000-4-4|Level 3, 2KV| ||||Surge|BS EN/EN61000-4-5|Level 4, 4KV/Line-FG ; 2KV/Line-Line| ||||Conducted|BS EN/EN61000-4-6|Level 3, 10V| ||||Magnetic Field|BS EN/EN61000-4-8|Level 4, 30A/m| ||||Voltage Dips and interruptions|BS EN/EN61000-4-11|>95% dip 0.5 periods, 100% dip 1 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods| ||||1695.7K hrs min. Telcordia SR-332 (Bellcore) ; 230.7K hrs min. MIL-HDBK-217F (25℃)||| |||**DIMENSION**|127*76.2*<br>(L*W*H)<br>30.5mm||| |||<br><br>℃<br><br><br><br><br><br><br><br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)<br>※:https://www.meanwell.com/serviceDisclaimer.aspx<br>**PACKING**<br>0.42Kg; 24pcs/12Kg/1.02CUFT<br>μ<br>μ|||| _File Name:LOP-500-SPEC 2024-01-05_ **LOP - 500 series** 500W 5"×3" Low Profile Open Frame Power Supply ## **Block Diagram** **==> picture [492 x 637] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc : 65KHz<br>PWM fosc : 100KHz<br>RECTIFIERS<br>& +12V FAN SUPPLY<br>FILTER<br>+S<br>EMI RECTIFIERS POWER RECTIFIERS +V<br>I/P & &<br>FILTER SWITCHING -V<br>PFC FILTER<br>-S<br>PG/PF(optional)<br>DETECTION<br>FG<br>CIRCUIT<br>O.L.P. CONTROL<br>O.V.P.<br>Derating Curve<br>500 500<br>With 23CFM Fan With 23CFM Fan<br>375 375<br>300 320<br>250 250<br>115VAC Convection 115VAC Convection<br>200 230VAC Convection 200 230VAC Convection<br>-40 0 10 20 30 40 50 60 70 80 (HORIZONTAL) -40 0 10 20 30 40 50 60 70 80 (HORIZONTAL)<br>AMBIENT TEMPERATURE ( ℃ )<br>(12~18V) (24~54V)<br>Cooling Max. Output Power Cooling Max. Output Power<br>Free air convection 300W Free air convection 320W<br>Force air with external Fan 500W Force air with external Fan 500W<br>Output Derating VS Input Voltage<br>100<br>90<br>80<br>70<br>60<br>50<br>40<br>80 100 115 120 140 160 180 200 220 240 264<br>INPUT VOLTAGE (VAC) 60Hz<br>LOAD (W)<br>LOAD (%)<br>**----- End of picture text -----**<br> _File Name:LOP-500-SPEC 2024-01-05_ **LOP - 500 series** 500W 5"×3" Low Profile Open Frame Power Supply ## **Mechanical Specification** **==> picture [463 x 538] intentionally omitted <==** **----- Start of picture text -----**<br> Unit:mm<br>127<br>5.7 115.6<br>JUN0000 oO000U0<br>HS1 CN221 42SVR31 CN3<br>LED<br>0000.0 0 ge e<br>FS1<br>1 -V<br>CN1 2<br>3<br>+V<br>FS2<br>a F G Es<br>SACU] BER HS2 S<br>Air flow<br>direction<br>of<br>FAN<br>23CFM<br>63.5<br>eI<br>AC Input Connector (CN1) : JST B3P-VH or equivalent FAN Connector(CN2) : TKP 8812-2 or equivalent<br>Pin No. Assignment Mating Housing Terminal Pin No. Assignment Mating Housing Terminal<br>1 AC/L 1 DC COM TKP 2502 TKP 8811<br>JST VHR JST SVH-21T-P1.1<br>2 No Pin 2 +12Vaux or equivalent or equivalent<br>or equivalent or equivalent<br>= 3 AC/N<br>Function Connector(CN3): TKP DH2I-2X2 or equivalent<br>DC Output Connector<br>Assignment Output Terminals Pin No. Assignment Mating Housing Terminal<br>-V M3.5 Pan HD screw in 2 positions 1 -R.S<br>= +V Torque to 8 lbs-in(90cNm)max. 2 +R.S TKP DH2 TKP<br>3 DC COM or equivalent or equivalent<br>Note: 4 PG(optional)<br>& TT<br>Class Ⅰ System: Mounting holes marked with have to be connected to safety earth.<br>Class Ⅱ System: Unnecessary to connect with safety earth.<br>; <br>4-φ3.5<br>5.7<br>76.2 64.8<br>5cm<br>30.5±1<br>3 max.<br>**----- End of picture text -----**<br> ## **Installation Manual** Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html _File Name:LOP-500-SPEC 2024-01-05_
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →