Image not available
Illustrative purposes only
LNE-24V100WAAA
LED DRIVER, CONST CURRENT/VOLT, 100W
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: DELTA ELECTRONICS / POWER
- Product type: AC / DC LED Power Supplies
- Product Range: LNE Series
- Output Current: 4A
- LED Driver Mode: Constant Current, Constant Voltage
- Output Power Max: 100W
- Input Voltage Max: 305VAC
- Input Voltage Min: 90VAC
- Output Voltage Max: 24V
- Power Supply Approvals: ITE
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 61.53 € |
| Current stock | 10+ |
| Lead time | 7 days |
**TECHNICAL DATASHEET** ## **LED Driver** LNE-100W Series / LNEV100W ## **LNE** ## **Highlights & Features** - North American and International AC voltage options - Up to 93.0% efficiency - 6kV common mode & 4kV differential mode surge immunity - Active PFC. Meets IEC/EN 61000-3-2, Class C - Adjustable voltage & current; dimming option available - IP65 or IP67 assembly for indoor and outdoor applications ## **Safety Standards** ## **Package Type** CB Certified for worldwide use **==> picture [74 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> A D<br>**----- End of picture text -----**<br> **Model Number:** LNE- `☐` V100W `☐☐☐` **Unit Weight:** 0.98 kg (2.16 lb) **Dimensions (L x W x D):** 220 x 68 x 38.8 mm (8.66 x 2.68 x 1.53 inch) ## **General Description** Delta LNE series of LED drivers comes with different combinations of features to suit different application requirements and energy optimization needs. Options include externally adjustable output voltage and current levels, and adjustment of LED brightness via 3-way built-in dimming function. All models in the LNE series come with a full corrosion resistant aluminum casing, major international safety certifications and are compliant with EN55015 immunity/Emissions/Harmonic requirements. The products are designed and rigorously tested to work in various indoor and outdoor LED lighting conditions. High surge immunity (common mode: 6kV, differential mode: 4kV), MTBF > 700,000hrs and compliance to IP65/IP67, all make the Delta LNE series an essential part of an energy efficient LED lighting power solution for both indoor and outdoor applications. ## **Model Information** LNE LED Driver |Model Number|Input Voltage Range|Rated OutputVoltage|Rated Output Current| |---|---|---|---| |LNE-12V100W☐☐☐|90-305Vac (LNE-☐V100W☐A☐)<br>90-264Vac (LNE-☐V100W☐C☐)|12Vdc|8.00A| |LNE-24V100W☐☐☐||24Vdc|4.00A| |LNE-36V100W☐☐☐||36Vdc|2.65A| |LNE-48V100W☐☐☐||48Vdc|2.00A| ## **Model Numbering** |**LN**<br>~~$n~~|**E –**<br>~~$n~~|**V**<br>~~$n~~|**100W**<br>~~$n~~|~~$n~~|~~$n~~|~~$n~~| |---|---|---|---|---|---|---| |LED<br>Driver|Product Series<br>E – High<br>efficiency and<br>PFC|Output Voltage<br>12V<br>24V<br>36V<br>48V|Output Power<br>(100W series<br>model)|Package Type<br>A – IP65 with potentiometers<br>to adjust output voltage &<br>constant current level<br>D – IP67 with dimming cable<br>to adjust constant current<br>level|Safety Approval<br>A – UL approval<br>C – ENEC, CE, KC,<br>PSE and CCC approval|Variable<br>A – Delta<br>standard| All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 1 **TECHNICAL DATASHEET** **LED Driver** LNE-100W Series / LNE0 V100W ## **Specifications** |Input Ratings / Characteristics|Input Ratings / Characteristics||||| |---|---|---|---|---|---| |Nominal Input Voltage||100-277Vac (LNE-☐V100W☐A☐)<br>100-240Vac(LNE-☐V100W☐C☐)|||| |Input Voltage Range*||90-305Vac (LNE-☐V100W☐A☐)<br>90-264Vac (LNE-☐V100W☐C☐)|||| |Nominal Input Frequency||50-60Hz|||| |Input Frequency Range||47-63Hz|||| |Input Current||1.30A max. @ 115Vac, 0.65A max. @ 230Vac,<br>0.60A max. @ 277Vac|||| |Efficiency at 100% Load|115Vac|90.0% typ.|92.0% typ.|91.5% typ.|92.0% typ.| ||230Vac|92.0% typ.|93.0% typ.|93.0% typ.|93.0% typ.| ||277Vac|92.0% typ.|93.0% typ.|92.5% typ.|93.0% typ.| |Max Inrush Current(Cold Start)||65A typ. @ 230Vac|||| |Power Factor at 100% Load||0.98 typ. @ 115Vac<br>0.95 typ. @ 230Vac<br>0.93 typ. @ 277Vac|||| |Total Harmonic Distortion||< 20% @ 115Vac/60 Hz & 230Vac/50 Hz (≥ 60% load)<br>< 20% @ 277Vac/50 Hz (≥ 75% load)|||| |Leakage Current||< 0.75mA @ 305Vac (LNE-☐V100W☐A☐)<br>< 0.75mA @ 264Vac (LNE-☐V100W☐C☐)|||| ## Input Ratings / Characteristics * Output power is de-rated at low input voltage. Please refer to Fig. 2 on page 10. All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 2 **TECHNICAL DATASHEET** ## **LED Driver** LNE-100W Series / LNEV100W ## Power Factor VS Output Load ## LNE-12V100W `☐` **==> picture [70 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> LNE-24V100W ☐<br>**----- End of picture text -----**<br> ## LNE-36V100W `☐` **==> picture [70 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> LNE-48V100W ☐<br>**----- End of picture text -----**<br> All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 3 **TECHNICAL DATASHEET** ## **LED Driver** LNE-100W Series / LNEV100W Efficiency VS Output Load at Nominal Output Voltage LNE-12V100W `☐` LNE-24V100W `☐` LNE-36V100W `☐` **==> picture [70 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> LNE-48V100W ☐<br>**----- End of picture text -----**<br> All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 4 **TECHNICAL DATASHEET** **LED Driver** LNE-100W Series / LNE0 V100W |Output Ratings / Characteristics*||||| |---|---|---|---|---| |Nominal Output Voltage|12Vdc|24Vdc|36Vdc|48Vdc| |LED System Voltage Range in CC Mode|6-12Vdc|12-24Vdc|18-36Vdc|24-48Vdc| |Output Voltage Adjustment Range**|10.8-13.5V|22.0-27.0V|33.0-40.0V|43.0-53.0V| |Nominal Output Current|8.0A|4.0A|2.65A|2.0A| |Output Current Adjustment Range**|4.0-8.0A|2.0-4.0A|1.325-2.65A|1.0-2.0A| |Output Power|96W|96W|95.4W|96W| |Line Regulation<br>@ 90-305Vac (LNE-☐V100W☐A☐)<br>@ 90-264Vac(LNE-☐V100W☐C☐)|± 0.5%|||| |Load Regulation (0-95% load)<br>@ 90-305Vac (LNE-☐V100W☐A☐)<br>@ 90-264Vac (LNE-☐V100W☐C☐)|± 2.0%|± 1.0%|± 0.5%|± 0.5%| |PARD*** (20MHz)|< 150mVpp|< 150mVpp|< 200mVpp|< 200mVpp| |Rise Time|< 50ms @ 115Vac & 230Vac & 277Vac|||| |Start-up Time|1200ms typ. @ 115Vac (100% load)<br>500ms typ. @ 230Vac & 277Vac (100% load)|||| |Hold-upTime|500ms typ. @ 230Vac & 277Vac (100% load)<br>16ms typ. @ 115Vac & 230Vac & 277Vac(100% load)|||| |Dynamic Response<br>(Overshoot & Undershoot O/P Voltage)|± 5% @ 0-90% load,@ 115Vac & 230Vac & 277Vac<br>(Slew Rate: 0.1A/µS)|||| * For power de-rating from 60°C to 70°C, see power de-rating at Fig.1 on page 10. ** For LNE- `☐` V100WA `☐☐` package type only. *** PARD is measured with an AC coupling mode, and in parallel with 0.1µF ceramic capacitor & 47µF electrolytic capacitor. All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 5 **TECHNICAL DATASHEET** > LNE-100W Series / LNE0 V100W ## **LED Driver** ||||**Model Number**|LNE-12V100W☐<br>LNE-24V100W☐<br>LNE-36V100W☐||LNE-48V100W☐| |---|---|---|---|---|---|---| |Mechanical||||||| |Casing||||Aluminium||| |Dimensions (L x W x D)||||220 x 68 x 38.8 mm (8.66 x 2.68 x 1.53 inch)||| |Unit Weight||||0.98 kg (2.16 lb)||| |CoolingSystem||||Convection||| |Wire|Input|LNE-☐V100W☐C☐||H05RN-F3G1.0mm2<br>Line: Brown, Neutral: Blue,||| |||||PE: Green/Yellow||| |||LNE-☐V100W☐A☐||SJTW 18AWGX3C<br>Line: Brown, Neutral: Blue,||| |||||PE: Green/Yellow||| ||Output|LNE-☐V100W☐C☐||H07RN-F2x1.5mm2<br>Positive: Red,Negative: Black||| |||LNE-☐V100W☐A☐||SJTW 14AWGX2C<br>Positive: Red, Negative: Black||| ||Dimming|LNE-☐V100W☐C☐||H05RN-F2x1.0mm2<br>Positive: White,Negative: Blue||| |||LNE-☐V100W☐A☐||SJTW 18AWGX2C<br>Positive: White,Negative: Blue||| |Noise(1 Meter frompower supply)||||Sound Pressure Level(SPL)< 25dbA||| |Environment|Environment|||||| |Surrounding Air Temperature|||Operating|-40°C to +70°C||| ||||Storage|-40°C to +85°C||| |Power De-rating||||> 60°C de-rate power by 4% / °C||| |||||< 100Vac de-ratepower by2% / Vac||| |OperatingHumidity||||5 to 95% RH(Non-Condensing)||| |OperatingAltitude||||0 to 3,000 Meters(9,840 ft.)||| |Shock Test|||Non-Operating|IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms,||IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms,| |||||3 shocks for each 3 directions||| |Vibration|||Non-Operating|IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G);||| |||||20 min per axis for all X, Y, Z direction||| |Pollution Degree||||2||| |Location Ratings||||Dry rating (LNE-☐V100WA☐☐)||| |(Included in safetyapprovals)||||Dry,dampratings(LNE-☐V100WD☐☐)||| |Protections||||||| |Overvoltage||||13.8-16.8V,<br>27.6-33.6V,<br>41.4-50.4V,||55.2-67.2V,| |||||Latch Mode<br>Latch Mode<br>Latch Mode||Latch Mode| |Overload / Overcurrent||||95-108% of rated load current, constant current limit||| |||||Auto-Recoverywhen the fault is removed||| |Over Temperature||||HiccupMode, Auto-Recoverywhen the fault is removed||| |Short Circuit||||Constant current limit, Auto-Recoverywhen the fault is removed||when the fault is removed| |Degree of Protection||||IP65 (LNE-☐V100WA☐☐)||| |||||IP67(LNE-☐V100WD☐☐)||| |Protection Against Shock||||Class I with PE* connection||| ## Mechanical ## Environment ## Protections *PE: Primary Earth All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 6 **TECHNICAL DATASHEET** **LED Driver** LNE-100W Series / LNE0 V100W ||**Model Number**|LNE-12V100W☐<br>LNE-24V100W☐|LNE-36V100W☐|LNE-48V100W☐| |---|---|---|---|---| |Reliability Data||||| |MTBF||> 700,000 hrs. per Telcordia SR-332||| |||at Input: 115Vac,Output: 100% load,Ta: 25°C||| |Expected Cap Life Time||10years (115Vac & 230Vac, 50% load @ 40°C)||| ## Reliability Data ## Safety Standards / Directives |Safety Standards / Directives||| |---|---|---| |Electrical Safety|CB scheme<br>ENEC<br>CCC<br>KC<br>PSE|**LNE-**☐**V100W**☐**C**☐**:**<br>IEC 61347-1, IEC 61347-2-13<br>EN 61347-1, EN 61347-2-13, EN 62384<br>GB19510.1, GB19510.14<br>KC61347-1, KC61347-2-13, KC62384<br>J61347-1, J61347-2-13| ||UL/cUL recognized|**LNE-**☐**V100W**☐**A**☐**:**<br>UL 8750 and CAN/CSA C22.2 No. 60950-1| |CE||In conformance with EMC Directive 2014/30/EU and Low Voltage<br>Directive 2014/35/EU**(LNE-**☐**V100W**☐**C**☐**)**| |Material and Parts||RoHS Directive 2011/65/EU Compliant| |Galvanic Isolation|Input to Output|3.85kVac| ||Input to Ground|2.0kVac| ||Output to Ground|1.5kVac| ## EMC |Emissions (CE & RE)|CISPR 15, EN 55015, GB17743<br>Compliance to CISPR 32,EN 55032,FCC Title 47: Class B| |---|---| |Immunity|EN 61547, Compliance to EN 55024| |Electrostatic Discharge<br>IEC 61000-4-2|Level 4 Criteria B2)<br>Air Discharge: 15kV<br>ContactDischarge:8kV<br>Level 3 Criteria A1)<br>Air Discharge: 8KV<br>ContactDischarge:6KV| |Radiated Field<br>IEC 61000-4-3|Level 3 Criteria A1)<br>80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation| |Electrical Fast Transient / Burst<br>IEC 61000-4-4|Level 3 Criteria A1)<br>2kV| |Surge<br>IEC 61000-4-5|Level 5 Criteria B2)<br>Common Mode3): 6kV<br>Differential Mode4): 4kV| |Conducted<br>IEC 61000-4-6|Level 3 Criteria A1)<br>150kHz-80MHz, 10Vrms| |Power Frequency Magnetic Fields<br>IEC 61000-4-8|Level 3 Criteria A1)<br>10A/Meter| |Voltage Dips<br>IEC 61000-4-11|100% dip, 0.5 cycle, Criteria A1)<br>70% dip, 10 cycle, Criteria B2)@ 100Vac & Criteria A1)@ 230Vac| |Harmonic Current Emission|IEC/EN 61000-3-2, Class C; GB17625.1<br>(THD conditions: 115Vac & 230Vac @ ≥ 60% load,<br>277Vac@≥ 75% load)| |Voltage Fluctuation and Flicker|IEC/EN 61000-3-3| - 1) Criteria A: Normal performance within the specification limits - 2) Criteria B: Temporary degradation or loss of function which is self-recoverable - 3) Asymmetrical: Common mode (Line to earth) - 4) Symmetrical: Differential mode (Line to line) All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 7 **TECHNICAL DATASHEET** ## **LED Driver** LNE-100W Series / LNEV100W ## **Block Diagram** **LNE-** `☐` **V100WA** `☐☐` **LNE-** `☐` **V100WD** `☐☐` All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 8 **TECHNICAL DATASHEET** ## **LED Driver** LNE-100W Series / LNEV100W ## **Dimensions** **L x W x D:** 220 x 68 x 38.8 mm [8.66 x 2.68 x 1.53 inch] **LNE-** `☐` **V100WA** `☐☐` **LNE-** `☐` **V100WD** `☐☐` ## **Item Device Description** - 1 Input cable 2 Output cable - 3 Constant voltage adjustment potentiometer - 4 Constant current adjustment potentiometer - 5 Dimming Cable - tc T case (tc): Temperature hot spot location on case. The temperature at this location will not exceed 80°C when used in accordance to conditions in this data sheet. All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 9 **TECHNICAL DATASHEET** ## **LED Driver** LNE-100W Series / LNEV100W ## **Engineering Data** Output Load De-rating VS Surrounding Air Temperature ## **Note** 1. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. 2. If the output capacity is not reduced when the surrounding air temperature >60°C, the device will run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. 3. Depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! **Fig. 1 De-rating for All Mounting Orientation (All Models)** > 60°C de-rate power by 4% / °C ## Output Load De-rating VS Input Voltage - No output power de-rating for the input voltage from:100Vac to 305Vac (LNE- `☐` V100W `☐` A `☐` ), 100Vac to 264Vac (LNE- `☐` V100W `☐` C `☐` ) **==> picture [227 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Fig. 2 De-rating for Low Input Voltage (All Models)<br> < 100Vac de-rate power by 2% / Vac<br>**----- End of picture text -----**<br> All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 10 **TECHNICAL DATASHEET** **LED Driver** LNE-100W Series / LNE0 V100W ## **Assembly & Installation** Mounting holes for LED driver assembly onto the mounting surface. - `Ⓐ` , `Ⓑ` Mounting holes for the LED driver (device). There are 3 mounting holes at either end of the device (locations 3). The device shall be mounted using a minimum of 2 out of the 3 mounting holes on both sides. Mounting shall be done using `Ⓐ` and `Ⓑ` in Fig. M4 screws with minimum length of 5mm. If customer’s end system or panel where the device is mounted does not have screw threads, please use suitable metal screw and nut to secure the device. - `Ⓒ` Surface `Ⓒ` belongs to customer’s end product or panel where the device is mounted. The device should be mounted on a sturdy heat conducting surface with minimum of 4 mounting holes, as detailed above. **Fig. 3 Mounting Hole Locations** ## Safety Instructions - ALWAYS switch mains of input power OFF before connecting and disconnecting the input voltage to the device. If mains are not turned OFF, there is risk of explosion / severe damage. - To guarantee sufficient convection cooling, keep a distance of 50mm above and lateral distance to nearby objects. - The device is not recommended to be placed on low thermal conductive surfaces. For example, plastics. - DO NOT insert any objects into the device. - Note that the enclosure of the device can become very hot depending on the surrounding air temperature and output load connected to the device. Risk of burns! - If the device is continuously operating outside the shaded region shown in Fig. 1. The device may be damaged or degraded. - When the PE (Green/Yellow) wire of the device is not connected, the device must be installed on a metal plate that has a PE connection. - The current rating for the all wires, connected to the input and output wires of the device, must be rated higher than or equal to the input and output current of the power supply. Please refer to the product specifications. - For device with dimming function, always ensure the dimming control is working properly. - Please ensure the correct tools are used for all adjustments and installations of the device. If in doubt, please consult your local Delta support or contact us via info@DeltaPSU.com. All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 11 **TECHNICAL DATASHEET** ## **LED Driver** LNE-100W Series / LNEV100W ## **Functions** ## Start-up Time The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied. ## Rise Time The time required for the output voltage to change from 10% to 90% of its final steady state set value. ## Hold-up Time Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value. ## **Graph illustrating the Start-up Time, Rise Time, and Hold-up Time** ## Inrush Current Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. ## Dynamic Response (For CV Operation Only) The power supply output voltage will remain within ±5% of its steady state value, when subjected to a dynamic load from 0 to 100% of its rated current. ## **90% Duty / 1 KHz** ## **90% Duty / 120 Hz** I, - All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 12 **TECHNICAL DATASHEET** ## **LED Driver** LNE-100W Series / LNEV100W ## Operating Methods of LED Modules-CV and CC Operation A typical LED power supply is able to either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs. Delta’s LNE drivers integrate CV+CC characteristics; so operation in CV mode (with external LED driver), in region `Ⓐ` or CC mode (direct drive, at area `Ⓑ` ). In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Should there be any compatibility issues or other questions with these adjustment methods, please contact with Delta. ## Dimming Operations This operation is available for LNE- `☐` V100WD `☐☐` only. The Dimming connection diagram for turning the lighting fixture ON/OFF can be configured as below. **==> picture [83 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> LNE- ☐ V100WD ☐☐<br>**----- End of picture text -----**<br> Please refer an example of reference configuration as follows. 1. Built-in 3 in 1 dimming function, IP67 rated. Output constant current level can be adjusted through output cable by connecting a resistance or 1~10Vdc or 10V PWM signal between DIM+ and DIM-. 2. The LED lighting fixture can be turned ON/OFF by the switch. All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 13 **TECHNICAL DATASHEET** **LED Driver** LNE-100W Series / LNEV100W 3. Please DO NOT connect "DIM-" to "V-". 4. Reference resistance value for output current adjustment (Typical). 5. 1 ~ 10V dimming function for output current adjustment (Typical). 6. 10V PWM signal for output current adjustment is also possible. For additional information, please contact your Delta sales representative. 7. Please note that LNE- `☐` V100WD `☐☐` can't turn the lighting fixture completely off (totally dark) by using any of these dimming adjustment methods. To completely turn off the lighting fixture, the input AC voltage must be removed. See illustration on previous page. ## External Input Protection Device The unit is protected at the L pin, with an internal fuse that cannot be replaced. The power supply has been tested and approved on 20A branch circuits without additional protection device. An external protection device is only required if the supplying branch has an ampacity greater than above. Thus, if an external protective device is necessary, a 20 Ampere C-characteristic circuit breaker can be utilized. All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 14 **TECHNICAL DATASHEET** ## **LED Driver** LNE-100W Series / LNEV100W ## Overload & Overcurrent Protections (Auto-Recovery) The power supply’s Overload (OLP) and Overcurrent (OCP) Protections will be activated when output current is between 95% and 108% of IO (Max load). Upon such an occurrence, the VO (output voltage) will start to droop. Once the power supply has reached its maximum power limit, the protection will be activated; and, the power supply will operate in “CC mode”. The power supply will recover once the fault condition once the cause of OLP or OCP is removed, and IO is back within the specified range. ## Overvoltage Protection (Latch Mode) The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 6 under “Protections”. Power supply will latch off, and require removal/re-application of input AC voltage in order to restart. ## **The power supply should be latch.** ## Over Temperature Protection (Auto-Recovery) ## Short Circuit Protection (Auto-Recovery) The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the power supply will operate in “CC mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. As mentioned above, the power supply also has Over Temperature Protection (OTP). In the event of a higher operating temperature at 100% load, the power supply will run into OTP when the operating temperature is beyond what is recommended in the de-rating graph. When activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recommended in the de-rating graph. ## **Others** ## Delta RoHS Compliant ## **Restriction of the usage of hazardous substances** The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and electronic equipment. RoHS is the abbreviation for “Restriction of the use of certain hazardous substances in electrical and electronic equipment”. This product conforms to this standard. ## PFC – Norm EN 61000-3-2 ## **Line Current Harmonic content** Typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor. In industrial environment, complying with EN 61000-3-2 is only necessary under special conditions. Complying to this standard can have some technical drawbacks, such as lower efficiency as well as some commercial aspects such as higher purchasing costs. Frequently, the user does not profit from fulfilling this standard, therefore, it is important to know whether it is mandatory to meet this standard for a specific application. ## Attention Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. All parameters are specified at 25°C ambient for all products unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 15
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →