Image not available
Illustrative purposes only
LHP-200-5
LED Driver, 200 W, 5 VDC, 40 A, 90 V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- Product Range: LHP-200
- Output Current: 40A
- Output Power Max: 200W
- Input Voltage Max: 264V
- Input Voltage Min: 90V
- Output Voltage Max: 5VDC
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 57.74 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- LHP 200 series** 200W Single Output with PFC Function ## ■ **Features** ‧ ‧ ‧ ‧ ## ■ ‧LED electronic signage ‧LED display application ‧LED luminous characters ‧ LED TV wall ‧ ‧ ‧ ‧ ‧ ## ■ ## ■ **LHP - 200 - 5** _File Name:LHP-200-SPEC 2018-04-08_ ## 200W Single Output with PFC Function ## **- LHP 200 series** ## **SPECIFICATION** |47 ~ 63Hz<br>168W<br>**RATED POWER(convection)**<br>0.39kg;30pcs/13.82kg/0.69CUFT<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGENote.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>2000ms, 100ms / 115AC 2000ms, 100ms / 230AC at full load<br>90 ~ 264VAC<br>Cold start 40A/115VAC 80A/230VAC<br><1.0mA / 240VAC<br>-40 ~ +80℃(Refer to “Derating Curve")<br>-40 ~ +90℃, 5~ 95% RH non-condensing<br>±0.02%/℃(0 ~ 50℃)<br>100K hrs min. MIL-HDBK-217F (25℃)<br>PF≥0.95/ 230VAC at full load<br>10ms/230VAC 10ms/115VAC<br>±1.0%<br>±1.0%<br>±5.0%<br>200mVp-p<br>4.2V<br>40A<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>1.AllparametersNOTspeciallymentionedaremeasuredat230VACinput,ratedloadand25ofambienttemperature.<br>2.Ripple&noisearemeasuredat20MHzofbandwidthbyusinga12"twistedpair-wireterminatedwitha0.1uf&47ufparallelcapacitor.<br>3.Tolerance:includessetuptolerance,lineregulationandloadregulation.<br>4.Deratingmaybeneededunderlowinputvoltages.Pleasecheckthederatingcurveformoredetails.<br>5.Theambient temperaturederatingof5/1000misneededforoperatingaltitudegreaterthan2000m(6500ft)<br>6.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives.ForguidanceonhowtoperformtheseEMCtests,pleasereferto“EMItestingofcomponentpowersupplies.”(asavailableonhttp://www.<br>meanwell.com)<br>**ENVIRONMENT**<br>**PROTECTION**<br>220*50*26mm (L*W*H)<br>Protection type :Hiccup mode, recovers automatically after fault condition is removed<br>Protection type :Shut down O/P voltage, recovers automatically aftertemperature goes down<br>2.2A/115VAC 1.1A/230VAC<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>**LHP-200-4.2**<br>**SAFETY STANDARDS**<br>**EMC EMISSION**<br>**EMC IMMUNITY**<br>Compliance to EN55032,GB/T9254 Class B,EN61000-3-2,EN61000-3-3<br>**SAFETY &**<br>**EMC**<br>**(Note.6)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.0KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG,O/P-FG:≥10M Ohms/500VDC/25℃/ 70%RH<br>Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11;<br>90%<br>5.5~ 6V<br>**SHORT CIRCUIT**<br>Protection type : recovers automatically after fault condition is removed<br>**OVER LOAD**<br>4.2~4.6V<br>200mVp-p<br>4.6V<br>40A<br>184W<br>**LHP-200-4.6**<br>4.5~5V<br>200mVp-p<br>5V<br>40A<br>200W<br>**LHP-200-5**<br>91%<br>91%<br>125 ~ 175% rated output power<br>1 ~ 200Hz, 2G 10min./1cycle, period for 30min. each along X, Y, Z axes<br>UL60950-1,EN60950-1 approved<br>**FUNCTION**<br>**POWER GOOD**<br>2.3~3.3V,10mA<br>3.8~4.2V<br>**VOLTAGE RANGE**|47 ~ 63Hz<br>168W<br>**RATED POWER(convection)**<br>0.39kg;30pcs/13.82kg/0.69CUFT<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGENote.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>2000ms, 100ms / 115AC 2000ms, 100ms / 230AC at full load<br>90 ~ 264VAC<br>Cold start 40A/115VAC 80A/230VAC<br><1.0mA / 240VAC<br>-40 ~ +80℃(Refer to “Derating Curve")<br>-40 ~ +90℃, 5~ 95% RH non-condensing<br>±0.02%/℃(0 ~ 50℃)<br>100K hrs min. MIL-HDBK-217F (25℃)<br>PF≥0.95/ 230VAC at full load<br>10ms/230VAC 10ms/115VAC<br>±1.0%<br>±1.0%<br>±5.0%<br>200mVp-p<br>4.2V<br>40A<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>1.AllparametersNOTspeciallymentionedaremeasuredat230VACinput,ratedloadand25ofambienttemperature.<br>2.Ripple&noisearemeasuredat20MHzofbandwidthbyusinga12"twistedpair-wireterminatedwitha0.1uf&47ufparallelcapacitor.<br>3.Tolerance:includessetuptolerance,lineregulationandloadregulation.<br>4.Deratingmaybeneededunderlowinputvoltages.Pleasecheckthederatingcurveformoredetails.<br>5.Theambient temperaturederatingof5/1000misneededforoperatingaltitudegreaterthan2000m(6500ft)<br>6.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives.ForguidanceonhowtoperformtheseEMCtests,pleasereferto“EMItestingofcomponentpowersupplies.”(asavailableonhttp://www.<br>meanwell.com)<br>**ENVIRONMENT**<br>**PROTECTION**<br>220*50*26mm (L*W*H)<br>Protection type :Hiccup mode, recovers automatically after fault condition is removed<br>Protection type :Shut down O/P voltage, recovers automatically aftertemperature goes down<br>2.2A/115VAC 1.1A/230VAC<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>**LHP-200-4.2**<br>**SAFETY STANDARDS**<br>**EMC EMISSION**<br>**EMC IMMUNITY**<br>Compliance to EN55032,GB/T9254 Class B,EN61000-3-2,EN61000-3-3<br>**SAFETY &**<br>**EMC**<br>**(Note.6)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.0KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG,O/P-FG:≥10M Ohms/500VDC/25℃/ 70%RH<br>Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11;<br>90%<br>5.5~ 6V<br>**SHORT CIRCUIT**<br>Protection type : recovers automatically after fault condition is removed<br>**OVER LOAD**<br>4.2~4.6V<br>200mVp-p<br>4.6V<br>40A<br>184W<br>**LHP-200-4.6**<br>4.5~5V<br>200mVp-p<br>5V<br>40A<br>200W<br>**LHP-200-5**<br>91%<br>91%<br>125 ~ 175% rated output power<br>1 ~ 200Hz, 2G 10min./1cycle, period for 30min. each along X, Y, Z axes<br>UL60950-1,EN60950-1 approved<br>**FUNCTION**<br>**POWER GOOD**<br>2.3~3.3V,10mA<br>3.8~4.2V<br>**VOLTAGE RANGE**|**LHP-200-4.2**<br>**LHP-200-4.6**<br>**LHP-200-5**| |---|---|---| ||**DC VOLTAGE**|4.2V<br>4.6V<br>5V| ||**RATED CURRENT**|40A<br>40A<br>40A| ||**RATED POWER(convection)**|168W<br>184W<br>200W| ||**RIPPLE & NOISE (max.)Note.2**|200mVp-p<br>200mVp-p<br>200mVp-p| ||**VOLTAGE RANGE**|4.2~4.6V<br>4.5~5V<br>3.8~4.2V| ||**VOLTAGE TOLERANCENote.3**|±5.0%| ||**LINE REGULATION**|±1.0%| ||**LOAD REGULATION**|±1.0%| ||**SETUP, RISE TIME**|2000ms, 100ms / 115AC 2000ms, 100ms / 230AC at full load| ||**HOLD UP TIME (Typ.)**|10ms/230VAC 10ms/115VAC| ||**VOLTAGE RANGENote.4**|90 ~ 264VAC| ||**FREQUENCY RANGE**|47 ~ 63Hz| ||**POWER FACTOR (Typ.)**|PF≥0.95/ 230VAC at full load| ||**EFFICIENCY (Typ.)**|90%<br>91%<br>91%| ||**AC CURRENT (Typ.)**|2.2A/115VAC 1.1A/230VAC| ||**INRUSH CURRENT (Typ.)**|Cold start 40A/115VAC 80A/230VAC| ||**LEAKAGE CURRENT**|<1.0mA / 240VAC| ||**SHORT CIRCUIT**|Protection type : recovers automatically after fault condition is removed| ||**OVER LOAD**|Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>125 ~ 175% rated output power| ||**OVER VOLTAGE**|Protection type :Hiccup mode, recovers automatically after fault condition is removed<br>5.5~ 6V| ||**OVER TEMPERATURE**|Protection type :Shut down O/P voltage, recovers automatically aftertemperature goes down| ||**POWER GOOD**|2.3~3.3V,10mA| ||**WORKING TEMP.**|-40 ~ +80℃(Refer to “Derating Curve")| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +90℃, 5~ 95% RH non-condensing| ||**TEMP. COEFFICIENT**|±0.02%/℃(0 ~ 50℃)| ||**VIBRATION**|1 ~ 200Hz, 2G 10min./1cycle, period for 30min. each along X, Y, Z axes| ||**SAFETY STANDARDS**|UL60950-1,EN60950-1 approved| ||**WITHSTAND VOLTAGE**|I/P-O/P:3.0KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG,O/P-FG:≥10M Ohms/500VDC/25℃/ 70%RH| ||**EMC EMISSION**|Compliance to EN55032,GB/T9254 Class B,EN61000-3-2,EN61000-3-3| ||**EMC IMMUNITY**|Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11;| ||**MTBF**|100K hrs min. MIL-HDBK-217F (25℃)| ||**DIMENSION**|220*50*26mm (L*W*H)| ||0.39kg;30pcs/13.82kg/0.69CUFT<br>**PACKING**<br>1.AllparametersNOTspeciallymentionedaremeasuredat230VACinput,ratedloadand25ofambienttemperature.<br>2.Ripple&noisearemeasuredat20MHzofbandwidthbyusinga12"twistedpair-wireterminatedwitha0.1uf&47ufparallelcapacitor.<br>3.Tolerance:includessetuptolerance,lineregulationandloadregulation.<br>4.Deratingmaybeneededunderlowinputvoltages.Pleasecheckthederatingcurveformoredetails.<br>5.Theambient temperaturederatingof5/1000misneededforoperatingaltitudegreaterthan2000m(6500ft)<br>6.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives.ForguidanceonhowtoperformtheseEMCtests,pleasereferto“EMItestingofcomponentpowersupplies.”(asavailableonhttp://www.<br>meanwell.com)|| _File Name:LHP-200-SPEC 2018-04-08_ **- LHP 200 series** 200W Single Output with PFC Function ## **Block Diagram** **==> picture [470 x 360] intentionally omitted <==** **----- Start of picture text -----**<br> I/P EMI FILTER& PFC SWITCH-POWER RECTIFIERS& +V<br>RECTIFIER CIRCUIT ING FILTER -V<br>FG DETECTION<br>O.T.P. O.L.P. CIRCUIT DC OK<br>CONTROL<br>O.V.P.<br>CURRENT<br>SHARING CS<br>Derating Curve<br>100<br>80<br>60<br>40<br>20<br>-40 0 15 30 40 50 60 70 80 (HORIZONTAL)<br>AMBIENT TEMPERATURE ( ℃ )<br>LOAD (%)<br>**----- End of picture text -----**<br> **==> picture [126 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> STATIC CHARACTERISTIC<br>**----- End of picture text -----**<br> **==> picture [196 x 149] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>90<br>80<br>70<br>60<br>50<br>40<br>90 100 110 120 140 160 180 200 220 240 264<br>INPUT VOLTAGE (V) 60Hz<br>LOAD (%)<br>**----- End of picture text -----**<br> _**File Name:LHP-200-SPEC 2018-04-08**_ **- LHP 200 series** 200W Single Output with PFC Function ## **Function Manual** **1.Share function** **==> picture [238 x 144] intentionally omitted <==** **----- Start of picture text -----**<br> +V +V<br>-V -V LOAD<br>PSU CS+<br>GND<br>P.G<br>+V<br>-V<br>PSU CS+<br>GND<br>P.G<br>**----- End of picture text -----**<br> _File Name:LHP-200-SPEC 2018-04-08_ **- LHP 200 series** ## 200W Single Output with PFC Function **==> picture [481 x 182] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification<br>Unit:mm<br>220 26<br>211<br>4.5<br>1 2 3 1<br>J1<br>1 2<br>2<br>3<br>3<br>4<br>5<br>3.<br>4<br>42 43 50<br>1<br>**----- End of picture text -----**<br> AC Input Terminal pin NO. Assignment DC Output Terminal pin NO. Assignment Pin No. Assignment Terminal Max mounting torque Pin No. Assignment Terminal Max mounting torque 1 (Elinker) 1,2 +V (Elinker) 2 AC/N LW1C-8.25-3P-130-04A 5Kgf-cm 3,4 -V LW1B-8.25-6P-130-05A 5Kgf-cm 3 AC/L Function Connector(J1) Pin No. Assignment Terminal 1 CS+ JIESHITAI 2 GND A2001A-03-A1MA-P-D 3 PG(Power Good) _File Name:LHP-200-SPEC 2018-04-08_ **- LHP 200 series** 200W Single Output with PFC Function ## **Installation** - 1.Operate with additional aluminum plate **==> picture [440 x 473] intentionally omitted <==** **----- Start of picture text -----**<br> In order to meet the“Derating Curve”and the “Static Characteristics” ,LHP-200 series must be installed onto an<br>aluminum plate(or the cabinet of the same size) on the bottom.The size of the suggested aluminum plate is shown<br>as below. And for optimizing thermal performance, the aluminum plate must have an even and smooth surface<br>(or coated with thermal grease), and LHP-200 series must be firmly mounted at the center of the aluminum plate.<br>unit:mm<br>M3*4<br>2.For heat dissipation, at least 5cm installation distance around the PSU should be kept, shown as below:<br>5cm 5cm<br>380<br>380<br>3<br>cm<br>5 cm<br>5<br>cm<br>5<br>**----- End of picture text -----**<br> _File Name:LHP-200-SPEC 2018-04-08_
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →