Image not available
Illustrative purposes only
LFWLT150-1303
AC/DC Open Frame Power Supply (PSU), ITE, 1 Output, 150W @ 300LFM, 100 W, 90V AC to 264V AC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EOS POWER
- Product type: AC / DC Open Frame Power Supplies
- SVHC: To Be Advised
- Product Range: WLT150 Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 4.17A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
- Power Rating (Forced Cooling): 150W @ 300LFM
- Power Rating (Convection Cooling): 100W
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 60.54 € |
| Current stock | 50+ |
| Lead time | 30 days |
**150 Watt Industrial (WLT)** ## Features - l 4 x 2 x 1.3 inches form factor - l 150 W with forced-air cooling - l Class I options - l 12 V @ 0.5 A fan voltage auxiliary output - l High efficiency > 86% - ~~l Low conducted and radiated noise~~ - l ~~Light weight~~ - l ~~Now IEC/EN/UL62368-1 Compliant~~ ~~**[New]**~~ - l Approved with metal enclosures/accessories - l Cover kit accessory available Electrical Specifications **==> picture [494 x 451] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |Input Voltage|90-264 VAC/120-390 VDC, Universal| |Input Frequency|47-63 Hz| |Input Current|120 VAC: 1.7 A max.|230 VAC: 0.85 A max.| |No Load Power|1.2 W| |Inrush Current|120 VAC: 35 A max.|230 VAC: 65 A max.| |Leakage Current|120 VAC: < 150 µA|230 VAC: < 300 µA| |Efficiency|120 VAC: 84% typical|230 VAC: 86% typical| |Hold-up Time|120 VAC: 6 ms|230 VAC: 10 ms| |Power Factor|120 VAC: 0.99|230 VAC: 0.95| |Output Power|150 W| |Peak Power|170 W for 0.2 s| |Line Regulation|+/-0.5%| |Load Regulation|+/-2.0%| |Transient Response|< 10%, 50% to 100% load change, 50 Hz, 50% duty cycle, 0.1 A/µs,| |recovery time < 5 ms| |Rise Time|< 100 ms| |Set Point Accuracy (Main Output)|+/-1%| |Output Adjustability|+/-3.0%| |Over Current Protection|110% typical above rating| |Over Voltage Protection|110 to 150%| |Short Circuit Protection|Short term, autorecovery| |-| |Switching Frequency|PFC converter: Variable, 35|250 kHz; 90 kHz typical| |Resonant converter: Variable, 35-250 kHz; 90 kHz typical| |Operating Temperature|-20 to +70°C, refer derating curve, -20 to 0°C, start-up is guaranteed| |Storage Temperature|-40 to +70°C| |Relative Humidity|95% Rh, noncondensing| |Altitude|Operating: 10,000 ft.; Nonoperating: 40,000 ft.| |MTBF|2.4m Hours, Telcordia -SR332-issue 3| |Isolation Voltage|Min. 4000 VDC between input to output| |Cooling|Convection: 80 W; 300 LFM: 100 W (5 V model)| |Convection: 100 W; 300 LFM: 150 W (other model)| |19| **----- End of picture text -----**<br> 4EM-21-209 1 39-DE60-45450-002 / B6 ||Class I with Screw Terminal<br>Class I with JST Connector<br>5 V<br>16.0 A<br>20.0 A<br>16.0 A<br>0.0 A<br>1%<br>LFWLT150-1000<br>LFWLT150-1300| |---|---| ||Class I with Screw Terminal<br>Class I with JST Connector<br>12 V<br>8.33 A<br>12.5 A<br>0.0 A<br>1%<br>LFWLT150-1001<br>LFWLT150-1301| ||Class I with Screw Terminal<br>Class I with JST Connector<br>15 V<br>6.67 A<br>10.0 A<br>0.0 A<br>1%<br>LFWLT150-1002<br>LFWLT150-1302| ||~~Class I with Screw Terminal~~<br>~~LFWLT150-1003~~| ||~~Class I with Screw Terminal~~<br>24 V<br>4.17 A<br>~~6.25 A~~<br>0.0 A<br>1%<br>~~LFWLT1501003~~| ||~~Class I with JST Connector~~<br>~~6.25 A~~<br>~~LFWLT150-1303~~| ||~~Class I with JST Connector~~<br>~~LFWLT1501303~~| ||~~Class I with Screw Terminal~~<br>~~LFWLT150-1004~~| ||~~Class I with Screw Terminal~~<br>48 V<br>2.08 A<br>3.13 A<br>0.0 A<br>1%<br>~~LFWLT1501004~~| ||~~Class I with JST Connector~~<br>3.13 A<br>~~LFWLT150-1304~~| ||~~Class I with JST Connector~~<br>~~LFWLT1501304~~| LFWLT100-CK metal cover kit accessory For Power supply unit with Base plate (metal accessory option) add “-B” suffix at the end of model number For Power supply unit with L bracket (metal accessory option) add “-L” suffix at the end of model number ~~For Power supply unit with U channel (metal accessory option) add “-U” suffx at the end of model number For Power supply unit with CK Cover kit (metal accessory option) add “-CK” suffx at the end of model number~~ ## Notes 1. Combined output power from V1 and V FAN should not exceed the total output power rating. ~~2. Ripple is 2% up to 20% load and < 1% above 20% load. Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Electrolytic capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.~~ ~~3. Fan output voltage tolerance is +/-20%.~~ ~~4. Peak current for fan output is 1 A.~~ ~~5. Class I products have an Earthing tab. Class II version available. Add “-II” suffx at the end of the Model Number to Order. Enquire with EOS Sales Rep before Order.~~ ~~6. Specifcations are for nominal input voltage, 25~~ ° ~~C and max. load unless otherwise stated.~~ 7. Derate output power linearly to 80% from 90 VAC to 80 VAC input. - - ~~8. When used in Cover Kit, de rate output power to 70 % under all operating conditions.~~ 4EM- ~~21-209 2 39-DE60-45450-002 / B6~~ **==> picture [54 x 53] intentionally omitted <==** **==> picture [265 x 148] intentionally omitted <==** **----- Start of picture text -----**<br> Connectors<br>J1 Pin 1 AC LINE<br>Pin 2 AC NEUTRAL<br>Spade Connector EARTH<br>(Class I product only)<br>J2 Pin 1, 2 V1<br>Pin 3, 4 RTN<br>J3 Pin 1 VFAN (+12 V/0.5 A)<br>Pin 2 RTN<br>**----- End of picture text -----**<br> ## ~~Mechanical Specifcations~~ **==> picture [510 x 162] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---| |AC Input Connector (J1)|Molex: 26|-|60|-|4030 or equivalent; Mating: 09|-|50|-|3031; Pins: 08|-|50|-|0106| |EARTH|Molex: 19705|-|4301 or equivalent| |Mating: 190030001| |-| |DC Output Connector (J2)|Option 1: Tyco: 1776112|4 or equivalent| |Mating: 13 AWG wire| |Option 2: JST: B4P|-|VH|-|B (LF) (SN) or B4P|-|VH (LF) (SN) or equivalent| |Mating: VHR|-|4M; Pins: SVH|-|41T|-|P1.1| |-| |Fan Connector (J3)|Tyco: 640456|2 or equivalent| |Mating: 640440|-|2| |Dimensions|4.0 x 2.0 x 1.324 inches (101.6 x 50.8 x 33.63 mm)| |Weight|150 g| **----- End of picture text -----**<br> ## ~~EMC~~ **==> picture [510 x 176] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |Parameter|Conditions/Description|Criteria| |Conducted Emissions|EN55032-B, CISPR22-B, FCC PART15-B|Pass| |Radiated Emissions|EN 55032 B|Pass| |Input Current Harmonics|EN 61000-3-2|Class D| |Voltage Fluctuation and Flicker|EN 61000-3-3|Pass| |ESD Immunity|EN 61000-4-2|Level 3, Criterion A| |Radiated Field Immunity|EN 61000-4-3|Level 3, Criterion A| |Electrical Fast Transient Immunity|EN 61000-4-4|Level 3, Criterion A| |Surge Immunity|EN 61000-4-5|Level 3, Criterion A| |Conducted Immunity|EN 61000-4-6|Level 3, Criterion A| |Magnetic Field Immunity|EN 61000-4-8|Level 3, Criterion A| |Voltage dips, interruptions|EN 61000-4-11|Criterion A & B| **----- End of picture text -----**<br> ## ~~Safety~~ **==> picture [510 x 80] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |CE Mark|Complies with LVD Directive| |Approval Agency|Nemko, IEC, UL| |Safety Standard(s) EN/IEC/UL 62368-1 (Ed.3)| |Safety File Number(s)|Class I UL: Certificate Number : E515384, Nemko: Certificate No: P20225090,| |CB Test Certificate No: NO111516| **----- End of picture text -----**<br> 4EM-21-209 3 39-DE60-45450-002 / B6 **==> picture [301 x 495] intentionally omitted <==** **----- Start of picture text -----**<br> Derating Curve<br>Convection load: 80W up to 50 °C<br>De-rate above 50 °C @ 3.125% per °C<br>m Forced air<br>@ Convection<br>Forced air cooled load : 100W up to 50°C<br>De-rate above 50 °C @ 2.5% per °C<br>50 60 70<br> 48V output<br>Convection load: 100W up to 50 °C<br>De-rate above 50 °C @ 2.5% per °C<br>m@ Forced air<br>@ Convection<br>Forced air cooled load : 150W up to 50°C<br>De-rate above 50 °C @ 1.67% per °C<br>**----- End of picture text -----**<br> 4EM-21-209 4 39-DE60-45450-002 / B6 ## Mechanical Drawing Notes: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following 1. Stand off, used to mount PCB has OD of 5.4 mm max. 2. Screws, used to fix PCB on stand off, have head dia of 6.0 mm max. 3. Washer, if used, to have dia of 6.5 mm max. 4EM-21-209 5 39-DE60-45450-002 / B6 ## Mechanical Drawing 4EM-21-209 6 39-DE60-45450-002 / B6 ## Mechanical Drawing 4EM-21-209 7 39-DE60-45450-002 / B6 ## Mechanical Drawing 4EM-21-209 8 39-DE60-45450-002 / B6 ## Mechanical Drawing 4EM-21-209 9 39-DE60-45450-002 / B6
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →