Image not available
Illustrative purposes only
LF 2005-S
Current Transducer, LF Series, 2kA, -3kA to 3kA, 0.3 %, Closed Loop Output, 15 Vdc to 24 Vdc
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- Sensor Output:Closed Loop; Supply Voltage DC Min:-; Supply Voltage DC Max:-; Current Measuring Range DC:-; Current Measuring Range AC:-; Response Ti; Available until stocks are exhausted
- SVHC: No SVHC (27-Jun-2024)
- Accuracy %: 0.3%
- Product Range: LF2005 Series
- Sensor Output Type: Closed Loop
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 353.41 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Current Transducer LF 2005-S** ## **I = 2000 A** PN For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). ## Q COMFLANT) §6 CG C€ jue 16103 SAM ## **Electrical data** |**I**PN|Primary nominal current rms|||||2000|2000|2000|2000||A| |---|---|---|---|---|---|---|---|---|---|---|---| |**I**PM|Primary current, measuring range @ ± 24 V|||||0 .. ± 3000||0 .. ± 3000||0 .. ± 3000|A| |**R**M|Measuring resistance @|**T**A= 70 °C||= 70 °C|= 70 °C|||**T**A= 85 °C|||| |||**R**M min **R**M max||||||**R**M min **R**M max|||| ||with ± 15 V<br>@ ± 2000 Amax|0|8|||||0||7|Ω| ||<br>@ ± 2200 Amax|0|5|||||0||4|Ω| ||with ± 24 V<br>@ ± 2000 Amax|5|29|||||13||28|Ω| ||<br>@ ± 3000 Amax|5|11||@ ± 2800 A 13||@ ± 2800 A 13|@ ± 2800 A 13||13|Ω| |**I**SN|Secondary nominal current rms|||||400|||||mA| |**K**N|Conversion ratio|||||1 : 5000|||||| |**V**C|Supply voltage (± 5 %)|||||± 15 .. 24|± 15 .. 24||± 15 .. 24||V| |**I**C|Current consumption (± 1)|||||33(@ ± 24 V) +|||(@ ± 24 V) +|(@ ± 24 V) +**I**SmA|| |**Accuracy - Dynamic performance data**|||||||||||| |**X**|Accuracy @**I**PN,**T**A= 25°C|||||± 0.3||± 0.3|± 0.3||%| |εL|Linearity error|||||< 0.1||< 0.1|< 0.1||%| |||||||Typ|||Max||| |**IO**<br>**I**OM|Offset current @**I**P= 0,**T**A= 25°C<br>Magnetic offset current @**I**P= 0 and specified|||= 0 and specified|= 0 and specified**R**M||||± 0.5||mA| ||after an overload of 3 x||||after an overload of 3 x**I**PN||||± 0.2||mA| |**I**OT|Temperature variation of**I**O|- 25°C .. + 85°C||||± 0.2 ± 0.5||± 0.2 ± 0.5|± 0.2 ± 0.5||mA| |||- 40°C .. - 25°C|||||||± 1.5||mA| |**t**r|Response time1)to 90 % of**I**PNstep|||||< 1|||||µs| |**di/dt**|di/dt accurately followed|||||> 50|> 50||||A/µs| |**BW**|Frequency bandwidth (-1 dB)|||||DC .. 100||DC .. 100|||kHz| |**General data**|||||||||||| |**T**A|Ambient operating temperature|||||- 40 .. + 85|||- 40 .. + 85||°C| |**T**S|Ambient storage temperature|||||- 50 .. + 90|||- 50 .. + 90||°C| |**R**S|Secondary coil resistance|@|@**T**A= 70°C|||25|||||Ω| |||@|@**T**A= 85°C|||26|||||Ω| |**_m_**|Mass|||||1.5|||||kg| ||Standards|||||EN 50178: 1997||||EN 50178: 1997|| ## **Features** - Closed loop (compensated) current transducer using the Hall effect - Isolated plastic case recognized according to UL 94-V0. ## **Advantages** - Excellent accuracy - Very good linearity - Low temperature drift - Optimized response time - Wide frequency bandwidth - No insertion losses - High immunity to external interference - Current overload capability. ## **Applications** - AC variable speed drives and servo motor drives - Static converters for DC motor drives - Battery supplied applications - Uninterruptible Power Supplies (UPS) - Switched Mode Power Supplies (SMPS) - Power supplies for welding applications. ## **Application Domain** - Industrial. Note:[1)] With a di/dt of 100 A/µs. Page 1/3 05July2011/version 11 www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. ## **Current Transducer LF 2005-S** ## **Isolation characteristics** |**V**d|Rms voltage for AC isolation test, 50 Hz, 1 min|6|kV| |---|---|---|---| |||Min|| |**dCp**|Creepage distance|29.1|mm| |**dCI**|Clearance distance|27.1|mm| |**CTI**|Comparative Tracking Index (group I)|600|| ## **Applications examples** **According to EN 50178 and IEC 61010-1 standards** and following conditions: - Over voltage category OV 3 - Pollution degree PD2 - Non-uniform field ||**EN 50178**|**IEC 61010-1**| |---|---|---| |**dCp**,**dCI**,<br>**V**w|Rated insulation voltage|Nominal voltage| |Basic insulation|4000 V|4000 V| |Reinforced insulation|2000 V|2000 V| ## **Safety** This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 05July2011/version 11 www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. ## **Dimensions LF 2005-S** (in mm) ## **Connection** ## **Mechanical characteristics** - General tolerance ± 1 mm - Transducer fastening Vertical or flat position 4 holes Ø 6.5 mm 4 steel screws M6 - Recommended fastening torque 5.5 Nm - ● Primary through-hole 60.5 x 20.5 or Ø max 57 mm - ● Connection of secondary S3P-VH ## **Remarks** - **I** S[ is positive when ] **[I]** P[ flows in the direction of the arrow.] - ● Temperature of the primary conductor should not exceed 100°C. - Dynamic performances (di/dt and response time) are best with a single bar completely filling the primary hole. - This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. Page 3/3 05July2011/version 11 www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →