Image not available
Illustrative purposes only
LESW 12-230V AC/DC
Analogue Timer, LESW, Delay-On-Release, 0.1 s, 100 h, 7 Ranges, 1 Changeover Relay
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: BROYCE CONTROL
- Product type: Analogue Timers - DIN Rail
- Product Range:LESW Series; Timer Functions:Delay-On-Release; Time Min:0.1s; Time Max:100h; No. of Timing Ranges:7Ranges; Timer Output:1 Changeover Relay; Supply Voltage Max:230V;
- SVHC: No SVHC (04-Feb-2026)
- Time Max: 100h
- Time Min: 0.1s
- Timer Output: 1 Changeover Relay
- Product Range: LESW
- Timer Functions: Delay-On-Release
- Current Rating Nom: 8A
- Supply Voltage Max: 230V
- No. of Timing Ranges: 7Ranges
- Connection / Termination: Screw Terminals
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 34.92 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Switch Initiated Delay Off (Delay On Release), Multi-voltage Timer** ## S CONTROL ## _**Type: LESW**_ > Terminal Protection aa ***NEW* 17.5mm DIN rail housing** > to IP20 Q **Switch Initiated Delay Off (Delay On Release) re-triggerable timing function** Q **7 Selectable time ranges (0.1 seconds – 100 hours)** Q **Fine adjustment of selected time range** _— a **Multi-voltage input (12 – 230V AC/DC)** of **External trigger input can be from Voltage Free Contact or Solid State** ant i) **Timer will still function with load connected to trigger (B1) input 1 x SPDT relay output 8A** a a **Green LED indication for supply / timing status** > Dims: to DIN a **Red LED indication for relay status** > 43880 W. 17.5mm a) **Conforms to IEC 61812** **==> picture [88 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> • FUNCTION DIAGRAM<br>**----- End of picture text -----**<br> **==> picture [285 x 72] intentionally omitted <==** **----- Start of picture text -----**<br> LED operation:<br>vl<br>LED Off LED On LED Flashing<br>• INSTALLATION AND SETTING Installation work must be carried<br>• BEFORE INSTALLATION, ISOLATE THE SUPPLY. out by qualified personnel.<br>• Connect the unit as required.<br>**----- End of picture text -----**<br> _Setting the unit._ - Set the “Range” ➍ to the required position (depending on whether seconds, minutes or hours are required). - Set the “Set %” adjustment ➌ as required. The “Set %” is a % of the selected range; so for example, a 30% setting on the 1 – 10 hour range will give 3 hours. - _Applying power._ - Apply power across terminals **A1** and **A2** and the green LED ➊ will illuminate. - The relay will remain de-energised (contacts **15** / **16** closed and **15** / **18** open) and red LED ➋ extinguished. - Close the contact across **A1** and **B1** and the relay will energise (contacts **15** / **16** open and **15** / **18** closed) and red LED illuminate. - When the contact across **A1** and **B1** opens, the delay period “t” will begin and the green LED will flash to indicate timing is now in progress. - After the delay period “t” has elapsed, the relay will de-energise (contacts **15** / **16** closed and **15** - / **18** open) and the red LED will extinguish. - The green LED will now remain permanently lit. - The whole timing process is repeated by removing and re-applying power. - If during the time period “t”, the contact across **A1** and **B1** closes, timing will stop and restart over again the next time the contact opens. _Note:_ > _1 In accordance with IEC 61812, the green LED is permitted to extinguish during a voltage dip or momentary interruption of the power supply providing the state of the output relay does not change. The dip / interruption duration and levels are defined in the product standard._ |•<br>_TECHNICAL SPECIFICATION_| |---| |Supply voltage U**(A1, A2)**:<br>12 – 230V AC/DC<br>Frequency range:<br>48 - 63Hz (AC supplies)<br>Supply variation:<br>+/ - 15%<br>Overvoltage category:<br>III (IEC 60664)<br>Rated impulse withstand voltage:<br>4kV (1.2/50µS) IEC 60664<br>Power consumption (max.):<br>12V<br>24V<br>110V<br>230V<br>AC:<br>0.3VA<br>0.4VA<br>1.3VA<br>3.4VA<br>DC:<br>0.26W<br>0.24W<br>0.47W<br>0.95W<br>Timing function:<br>Switch Initiated Delay Off<br>Timing ranges (7):<br>Seconds:<br>Minutes:<br>Hours:<br>0.1 – 1<br>0.1 – 1<br>0.1 – 1<br>1 – 10<br>1 – 10<br>1 – 10<br>10 - 100<br>Reset time:<br>100mS<br>Accuracy:<br>±1% of maximum full scale<br>Adjustment accuracy:<br>< 5% of maximum full scale<br>Repeat accuracy:<br>±0.5% at constant conditions (IEC 61812)<br>Drift with temperature:<br>±0.05% /°C<br>Drift with voltage:<br>±0.2% / V<br>External trigger input**(A1 > B1)**:<br>Volt Free Contact, Open Collector<br>External loading:<br>Yes, between B1 and A2 (i.e. LED, Relay, Lamp)<br>Trigger threshold:<br>>75% of voltage present between A1 and A2 (auto-set)<br>Minimum trigger time:<br>AC: 60mS DC: 40mS (B1 terminal unloaded)<br>Maximum input frequency:<br>10 Hz (with 50:50 duty cycle)<br>Maximum cable length:<br>10m<br>(between Timer and external switching device)<br>Power on indication / Timing1:<br>Green LED<br>Relay status<br>Red LED<br>Ambient temp:<br>-20 to +60°C<br>Relative humidity:<br>+95%<br>Output**(15, 16, 18)**:<br>SPDT relay<br>Output rating:<br>AC1<br>250V 8A (2000VA)<br>AC15<br>250V 5A (no), 3A (nc)<br>DC1<br>25V 8A (200W)<br>Electrical life:<br>≥150,000 ops at rated load<br>Dielectric voltage:<br>2kV AC (rms) IEC 60947-1<br>Rated impulse withstand voltage:<br>4kV (1.2/50µS) IEC 60664<br>Housing:<br>Orange flame retardant UL94<br>Weight:<br>≈60g<br>Mounting option:<br>On to 35mm symmetric DIN rail to BS EN 60715<br>or direct surface mounting via 2 x M3.5 or 4BA screws<br>using the black clips provided on the rear of the unit.<br>Terminal conductor size<br>≤2 x 2.5mm2solid or stranded<br>Approvals:<br>Conforms to IEC 61812.<br>CE, C-tick<br>and RoHS Compliant.<br>EMC: Immunity: EN 61000-6-2 (EN 61000-4-3 10V/m<br>80MHz - 2.7GHz)<br>Emissions: EN 61000-6-4<br>e(U)usLISTED !ND.CONT.EQ.<br>111187<br>©| **==> picture [560 x 158] intentionally omitted <==** **----- Start of picture text -----**<br> • , CONNECTION DIAGRAM • , SETTING DETAILS • , DIMENSIONS<br>SupplyL/+veN/-veExternal é ow A1 B1 15 7 1. Power supply status / Timing (Green) LED 2. Relay output status (Red) LED cl]t <——SSBROYCE ➊ le j 89 (exc. clips)67.545 epo . .<br>N.O. contact 3. “Set %” adjustment<br>4. Time delay “Range”<br>Example of external selector<br>15 loads that can beconnected to thetrigger input 0.1-1,1-10 \ Insert screwdriverto release clips<br>R simultaneously.<br>/ ➍ 014 -1 0 i« b eo<br>16 18 10. 20 ➌<br>16 18 240-400 1100"ae @ Withdraw clips fully when )<br>L ➋ 400 9080 surface mounting<br>A2 92 (+/- 1mm) all dimensions in mm<br>Broyce Control Ltd., Pool Street, Wolverhampton, West Midlands WV2 4HN. England LESW-3-A.DOCX<br>1805<br>Relay Lamp<br>66.5<br>49.5<br>29<br>**----- End of picture text -----**<br> Broyce Control Ltd., Pool Street, Wolverhampton, West Midlands WV2 4HN. England Tel: +44 (0) 1902 773746 Fax: +44 (0) 1902 420639 Email: sales@broycecontrol.com Web: www.broycecontrol.com _The Information provided in this literature is believed to be accurate (subject to change without prior notice); however, use of such information shall be entirely at the user’s own risk._
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →