Image not available
Illustrative purposes only
LER00040TBPBKMAA15
SWITCHES PRESSURE SWITCHES
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: HONEYWELL / PARTNER STOCK
- Product type: Pressure Switches
- SVHC: No SVHC (25-Jun-2025)
| Delivery and price | |
|---|---|
| Units per pack | 6 |
| Price | 63.17 € |
| Current stock | 50+ |
| Lead time | 30 days |
## Honeywell Pressure Switches HP, HE, MH, ME, LP, LE, 5000, and 1000 Series # 50094081 _Issue 5_ **==> picture [62 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> Datasheet<br>**----- End of picture text -----**<br> ## DESCRIPTION The Honeywell Pressure Switch portfolio consists of: - High Pressure (HE/HP Series) - Medium Pressure (ME/MH Series) - Low Pressure (LE/LP Series) - 5000 Series, 1000 Series ## FEATURES - Pressure switching set point range: 3.5 psi to 4500 psi - Proof pressure: from 500 psi up to 10,000 psi - Burst pressure: from 1250 psi up to 20,000 psi - Life cycle rating up to 2 million - IP67 sealing rating[4] - Operating temperature: -40 °C to 120 °C [-40 °F to 248 °F] These pressure switches are durable, reliable electromechanical gauge pressure on/off switches that are available with either single pole single throw (SPST) normally open or normally closed circuitry, or single pole double throw (SPDT) circuitry. Their high proof pressure and burst pressure ratings can allow for use in many rugged applications that require the making or breaking of an electrical connection in response to a pressure change of the system media. - Hysteresis option[5] - More than 15 pressure port options and over 30 electrical terminations - Plated steel, brass or stainless steel options[3] - Switching point accuracy up to ±2 % ## POTENTIAL APPLICATIONS ## DIFFERENTIATION - Through optional smart diagnostic technology, - Honeywell pressure switches are able to detect failures such as open circuits, cut wires, worn insulation, and more[6] - Optional smart diagnostic technology allows up to four segregated signal amplitudes to perform diagnostics and status[6] - Pressure port snubber suppresses pressure spikes[2] - IP67 sealing provides enhanced durability in harsh environmental and washing applications[1] - Agricultural machinery - Heavy duty construction machinery and trucks - Lawn & garden machinery - Marine vessels - Material handling machinery - Railway - CNC machines - Compressors/boilers - Fracking equipment - Food & beverage equipment - Generators - HVAC/R equipment - Mud pumps - Pneumatic equipment - Presses/punches - Pressure washers ## VALUE TO CUSTOMERS - Designed to provide resistance to corrosion and enhances equipment life with available two million life cycle rating and IP67 rating[1] - Can expedite design and product cycle due to ability to receive samples in two weeks and production units in four weeks - Can reduce tooling, service, and manufacturing labor costs due to standard connections, extended product life, and expedited design and production cycle - Trash compactors - Water pumps & jet cutting machines ## PORTFOLIO Honeywell also offers the PBN1 Series and PBN3 Series Pressure Sensor. - 1 HP, HE, MH, ME, LP, LE Series - 2 HP, HE Series - 3 ME, MH, LP, LE Series - 4 HP, HE, LP, LE, ME Series - 5 HP, HE, LP Series - 6 HP, HE, ME, LP, LE Series Safety and Productivity Solutions ## Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series Table 1. Specifications **==> picture [542 x 593] intentionally omitted <==** **----- Start of picture text -----**<br> Character-<br>HP Series HE Series ME Series MH Series LP Series LE Series 5000 Series 1000 Series<br>istic<br>Product<br>–<br>length (various see pages 5 and 6 see page 5 see page 8 see page 7 see page 9 see page 9 see page 10<br>terminations)<br>Product length 58,42 mm 65,6 mm<br>(blade) see pages 5 and 6 see page 5 see page 8 see page 7 see page 9 see page 9 [2.3 in] [2.583 in]<br>Product length 60,96 mm –<br>(#8-32 screws) see pages 5 and 6 see page 5 see page 8 see page 7 see page 9 see page 9 [2.4 in]<br>Product length 73,66 mm –<br>(Metripack) see pages 5 and 6 see page 5 see page 8 see page 7 see page 9 see page 9 [2.9 in]<br>Hex size 27 mm 27 mm 27 mm 27 mm 27 mm 27 mm 0.50 in (steel) M10 x 1.25 banjo<br>0.437 in (brass) ftting<br>Ease of 18 mm open<br>installation box spanner box spanner box spanner box spanner box spanner box spanner 1/2 in open spanner spanner<br>Snap-action switch yes yes no no yes no no no<br>Set point [1] 10 psi to 60 psi<br>100 psi to 4500 psi 150 psi to 4500 psi 25 psi to 350 psi 40 psi to 500 psi 3.5 psi to 150 psi 3.5 psi to 150 psi 75 psi to 150 psi<br>range [0,69 bar to 2,7 bar]<br>Set point 6 (Base Style A) 6 4 4 4 4 8 –<br>ranges 7 (Base Style B)<br>0.5 psi to 1 psi<br>(±0.3 psi);<br>40 psi to 70 psi 1.1 psi to 3 psi<br>25 psi to 50 psi (±7 psi); (±0.5 psi);<br>100 psi to 150 psi 150 psi to 1000 psi<br>(±3 psi); >70 psi to 130 psi 3.1 psi to 7 psi<br>(±10 %); (±14%);<br>>50 psi to 100 psi (±10 psi); (±1 psi);<br>150 psi to 500 psi 1000 psi to<br>Set point (±7 psi); >130 psi to 200 psi 3.5 psi to 10 psi (±1 psi); 8 psi to 13 psi<br>(±6 %); 2000 psi 20 psi ±10 psi;<br>accuracy 501 psi to 4000 psi (±12 %); >100 psi to 150 psi (±15 psi); >10 psi to 50 psi (±3 psi); (±2 psi); 58 psi ±20 psi<br>@ 25 °C (±10 psi); >200 psi to 280 psi >50 psi to 100 psi (±7 psi); 14 psi to 24 psi<br>(±3.5 %); 2000 psi to<br>(before test) >150 psi to 250 psi (±20 psi); >100 psi to 150 psi (±10 psi) (±3 psi);<br>4000 psi to 4500 4000 psi<br>(±13 psi); >280 psi to 350 psi 25 psi to 50 psi<br>psi (±11 %);<br>>250 psi to 350 psi (±30 psi); (±5 psi);<br>(±2 %) >4000 psi (±10 %)<br>(±16 psi) >350 psi to 500 psi 51 psi to 90 psi<br>(±40 psi) (±7 psi);<br>91 psi to 150 psi<br>(±10 psi)<br>0.5 psi to 3 psi<br>40 psi to 70 psi (±1.5 psi);<br>25 psi to 50 psi (±6 psi); 4 psi to 7 psi<br>(20 psi); >70 psi to 130 psi 3.5 psi to 10 psi (±2.5 psi);<br>>50 psi to 100 psi (±10 psi); (±2.8 psi); 8 psi to 13 psi<br>(30 psi); >130 psi to 200 psi >10 psi to 50 psi (±3.5 psi);<br>Average dead- n/a n/a >100 psi to 150 psi (±15 psi); n/a (±14 psi); 14 psi to 24 psi n/a<br>band max. (40 psi); >200 psi to 280 psi >50 psi to 100 psi (±8 psi);<br>>150 psi to 250 psi (±20 psi); (±38 psi); 25 psi to 50 psi<br>(50 psi); >280 psi to 350 psi >100 psi to 150 psi (±15 psi);<br>>250 psi to 350 psi (±30 psi); (±40 psi) 51 psi to 90 psi<br>(60 psi) >350 psi to 500 psi (±23 psi);<br>(±40 psi) 91 psi to 150 psi<br>(±40 psi)<br>Operating 1400 psi<br>5,000 psi max. 5,000 psi max. 500 psi max. 600 psi max. 250 psi max. 250 psi max. 150 psi, 250 psi<br>pressure [2] [96,5 bar] max.<br>10,000 psi (Base<br>Style A) 2973 psi<br>Proof pressure [3] 10,000 psi 4,000 psi 6,000 psi 500 psi 500 psi 500 psi<br>6,500 psi (Base [205 bar]<br>Style B)<br>5 % to 55 % 3 % to 65 % 5 % to 55 %<br>Hysteresis (based on set point (based on set point n/a n/a (based on set point n/a n/a n/a<br>range) range) range)<br>20,000 psi (Base<br>3500 psi<br>Burst pressure [4] Style A); 9,000 psi 20,000 psi 8,000 psi 9,000 psi 1250 psi 1250 psi 4000 psi [241 bar]<br>(Base Style B)<br>15 A, 6 Vdc;<br>Current rating 5 A at 250 Vac 3 A at 250 Vac 7.5 mA to 3 A, 100 mA to 3 A max. 7.5 mA to 5 A, 7.5 mA to 3 A, 8 A, 12 Vdc; 12 Vdc with two-<br>(resistive) 5 A at 24 Vdc 3 A at 24 Vdc 24 Vdc and 250 Vac 24 Vdc and 250 Vac 24 Vdc and 250 Vac 1157 bulbs (4.4 A)<br>4 A, 24 Vdc<br>Current rating 5 A at 115 Vac (SX n/a n/a n/a 1 A at 28 Vdc n/a 1 A, 120 Vac n/a<br>(inductive) rating); 3 A at 28 Vdc 0.5 A, 240 Vac<br>**----- End of picture text -----**<br> 8Port Style C: Switches less than 975 psi will use Base Style B; switches greater than 975 psi will use Base Style A. Port Styles F and G: Switches less than 350 psi will use Base Style B; switches greater than 350 psi will use Base Style A. Port Styles A, B, E, M, P, T, and Y will use Base Style B. Switches less than 150 psi will only use Base Style B. 2 sensing.honeywell.com ## Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series **==> picture [542 x 636] intentionally omitted <==** **----- Start of picture text -----**<br> Character-<br>HP Series HE Series ME Series MH Series LP Series LE Series 5000 Series 1000 Series<br>istic<br>Rated thermal<br>5 A 3 A 3 A n/a 5 A 3 A n/a n/a<br>current<br>Rated insula-<br>28 V 28 V 28 V n/a 28 V 28 V n/a n/a<br>tion voltage<br>Short-circuit<br>protective Class J fuse (10 A, 600 V) n/a Class J fuse (10 A, 600 V) n/a n/a<br>device c-type<br>max. rating<br>Conditional<br>short circuit 1000 A n/a 1000 A 1000 A n/a n/a<br>current<br>Pollution<br>3 (macro environment) n/a 3 (macro environment) n/a n/a<br>degree<br>Temperature -40 °C to 120 °C -40 °C to 85 °C -40 °C to 121 °C -20 °C to 74 °C<br> -40 °C to 120 °C [-40 °F to 248 °F]<br>rating [-40 °F to 248 °F] [-40 °F to 185 °F] [-40 °F to 250 °F] [-4 °F to 165 °F]<br>Media multiple ports multiple ports 1/8-27 NPT male multiple ports<br>connection available available multiple ports available thread available<br>A = 1/4-18 NPT<br>A = 1/4-18 NPT B = 1/8-27 NPT A = 1/4-18 NPT A = 1/4-18 NPT<br>B = 1/8-27 NPT C = 1/2-20 UNF B = 1/8-27 NPT B = 1/8-27 NPT<br>C = 1/2-20 UNF D = 1/8-27 PTF C = 1/2-20 UNF C = 1/2-20 UNF<br>D = 1/8-27 PTF E = M12 × 1.5 D = 1/8-27 PTF D = 1/8-27 PTF<br>E = M12 × 1.5 F = M14 × 1.5 E = M12 × 1.5 E = M12 × 1.5<br>C = 1/2-20 UNF<br>F = M14 × 1.5 G = 9/16-18 UNF F = M14 × 1.5 F = M14 × 1.5 M10 x 1.25 double<br>F = M14 × 1.5<br>Refer to product G =9/16-18 UNF G = 9/16-18 UNF H = 3/4-16 UNF G = 9/16-18 UNF G = 9/16-18 UNF banjo;<br>Pressure ports nomenclature for H = 3/4-16 UNF H = 3/4-16 UNF J = G1/8 BSPP H = 3/4-16 UNF H = 3/4-16 UNF 1/8-27 NPT M10 x 1;<br>pressure port types. K = M18 × 1.5 J = G1/8 BSPP L = 3/8-24 UNF J = G1/8 BSPP J = G1/8 BSPP 1/8-27 NPT<br>M = 7/16-20 UNF M = 7/16-20 UNF M = 7/16-20 UNF M = 7/16-20 UNF<br>N = 7/8-14 UNF<br>R = R1/8 BSPT P = 1/2-14 NPT R = R1/8 BSPT R = R1/8 BSPT<br>T = M10 × 1.0 R = R1/8 BSPT T = M10 × 1.0 T = M10 × 1.0<br>V = R1/2 BSPT T = M10 × 1.0 V = R1/2 BSPT V = R1/2 BSPT<br>Y = G1/4 BSPP V = R1/2 BSPT Y = G1/4 BSPP Y = G1/4 BSPP<br>Z = R1/4 BSPT Y = G1/4 BSPP Z = R1/4 BSPT Z = R1/4 BSPT<br>Z = R1/4 BSPT<br>Circuit forms [5] SPDT, SPST - NO/NC SPDT, SPST - NO/NC SPST - NO/NC SPDT, SPST - NO/NC SPDT, SPST - NO/NC SPST-NO; SPST-NC SPNO<br>Smart pressure single- or dual-resistor topology available – single- or dual-resistor topology available – –<br>2 million (Base A)<br>Life 1 million (Base B) 1 million 1 million 1 million 2 million 1 million 100,000 cycles 100,000 cycles<br>Agency approv- – – – – – – UL Custom –<br>als (special use<br>(select models)<br>switches)<br>Agency approv- CE CE CE CE CE CE – –<br>als (other)<br>Field<br>adjustability [6] no no yes yes yes yes yes no<br>Spike dampening yes yes no no no no no no<br>IP67 (connecetors)<br>IP67 (connectors) IP67 (connectors) IP67 (connectors)<br>Ingress IP67 (wire/Base A) IP67 (connectors) IP67 (wire out) IP67 (connectors) IP67 (wire out) IP67 (wire out) IP00 IP65<br>protection [7] IP69K (wire/Base B) IP00 (blade/screw) IP00 (blade/screw)<br>IP00 (blade/screw) IP00 (blade/screw) IP00 (blade/screw)<br>IP00 (blade/screw)<br>Vibration resistance swept sine: 10 Hz to 2000 Hz at 15 g, 20 min/sweep; 8 hours in each axisrandom: 5 Hz to 2000 Hz, 8 hours/axis; 14,88 g-RMS, each axis – –<br>Shock<br>500 m/sec [2] , 11 mSEC, 100 shocks / axis 500 m/sec [2] , 11 mSEC 15 G @ 5 mSEC<br>resistance<br>Wetted part (diaphragm) n/a (TeflonKapton [®] coated) [® ] Nitrile/EPDM/LTNB (TeflonKapton [®] coated) [® ] Tefzel [®] Polymide film EPDM<br>Wetted part (piston) nitrile o-ring, steel piston nitrile or EPDM o-ring nitrile or EPDM o-ring nitrile or EPDM o-ring nitrile or EPDM o-ring nitrile or EPDM o-ring EPDM<br>133 g [4.7 oz] (Base Style A)<br>Weight 53 g [1.9 oz] 53 g [1.9 oz] 58 g [2.0 oz] 53 g [1.9 oz] 65 g [2.3 oz] 40 g [1.4 oz]<br>178 g [6.28 oz] (Base Style B)<br>Contacts silver / gold inlay silver gold plated gold plated gold plated gold plated silver-plated copper silver-plated copper<br>Rynite 545 glass<br>glass reinforced filled (housing);<br>Product finish zinc plating zinc plating zinc plating zinc plating zinc plating zinc plating polyester (housing);<br>Travalent plated steel<br>plated steel (base)<br>(base)<br>**----- End of picture text -----**<br> - 1Set point: Point at which switch actuates or de-actuates 2Operating pressure: Maximum normal system operating pressure 3Proof pressure: Maximum pressure that the switch can handle while it maintains set point accuracy. Intermittent spikes to this level are acceptable. 4Burst pressure: Point of complete switch failure - 5SPST: Single pole, single throw. SPDT: Single pole, double throw. NO: Normally open. NC: Normally closed. - 6Field adjustability only available with AA, BA, CA, and DA (SPST only) terminations. 7IP00 for AA and BA terminations. Safety and Productivity Solutions 3 Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series ## Table 2. Terminations |Series|Available Terminations| |---|---| |HP, HE, ME,<br>LP, LE|AA = Spade Terminals<br>BA = Screw Terminals<br>CA = Deutsch DT04-3P-E005 (3-Pin Connector)<br>DA = Amp Super Seal 1.5 - 282105-1 (3-Pin Connector)<br>EA = 10-inch Cable, 18 AWG (Wire Out, No Connector)<br>FA = 10-inch Cable w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)*<br>GA = 10-inch Cable w/Amp Super Seal 1.5 - 282105-1 (3-Pin Connector) (18 AWG)*<br>HA = 10-inch Cable w/Metripack 280 Delphi 15300002 (2-Pin Connector) (18 AWG)*<br>JA = 10-inch Cable w/Din43650-C (3-Pin Connector) (18 AWG)*<br>KA = 10-inch Cable w/M12x1 (Brad Harrison Micro) - 21032121306 Harting P/N (3-Pin Connector) (18 AWG)*<br>LA = 10-inch Cable w/Packard Weatherpack Male Terminal - 12020827 (3-Pin Connector) (18 AWG)*<br>MA = 10-inch Cable w/Deutsch DT04-2P-E005 (2-Pin Connector) (18 AWG)<br>NA = 3-inch Cable w/Packard 2P Tower Connector - 12015792 (2-Pin Connector) (18 AWG)<br>PA = 2.75-inch Cable w/Packard 2P Shroud Connector - 12010973 (2-Pin Connector) (18 AWG)<br>RA = 4-inch Cable w/Packard 2P Shroud Connector - 12010973 (2-Pin Connector) (16 AWG)<br>SA = 5.5-inch Cable w/ITT Cannon 2P Sure-Seal Circular Connector - SS2R-120-1804-000 (2-Pin Connector) (18 AWG)<br>TA = 8.5-inch Cable w/ITT Cannon 3P Sure-Seal Circular Connector - SS3R-120-8551-001 (3-Pin Connector) (16 AWG)*<br>UA = 10-inch Cable - Vacuum Impregnated w/Deutsch DT06-3S-EP06 (3-Socket Connector) (16 AWG)*<br>VA = 10-inch Cable - Vacuum Impregnated w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)*<br>WA = 4.5-inch Cable w/Blade Terminals 6,3 mm x 0,8 mm (16 AWG)*<br>XA = 10-inch Cable w/ Metripack 2-Pin Shroud Connector 153000027 (18 AWG)<br>YA = 6-inch Cable w/Amp Super Seal 1.5 - 282104-1 (2-Pin Connector) (18 AWG)*<br>ZA = 10-inch Cable w/Deutsch DT06-2S-CE06 (2-Socket Connector) (18 AWG)<br>AB = Deutsch DT04-2P-E005 (2-Pin Connector)<br>BB = 10-inch Cable w/Metripack 150 Delphi 12129615 (3-Pin Connector) (18 AWG)*<br>CB = 6-inch Cable w/ AMP Super Seal 1.5 - 282080-1 (2-Pin Connector) (18 AWG)<br>DB = 10-inch Cable w/AMP 2,5 mm System Series Connector 1-967402-1 (18 AWG)*<br>EB = 4.5-inch Cable w/Packard Shroud Connector 12015792 (2-Pin Connector) (18 AWG)<br>FB = 10-inch Cable w/Metripack 150 Delphi 12052641 (2-Pin Connector) (18 AWG)<br>GB = 8.5-inch Cable w/Deutsch Plug HD 16-3 96S (3-Pin Connector) (16 AWG)| |MH|AA = Spade Terminals<br>BA = Screw Terminals<br>DA = Amp Super Seal 1.5 - 282105-1 (3-Pin Connector)<br>EA = 10-inch Cable, 18 AWG (Wire Out, No Connector)<br>HA = 10-inch Cable w/Metripack 280 Delphi 15300002 (2-Pin Connector) (18 AWG)*<br>MA = 10-inch Cable w/Deutsch DT04-2P-E005 (2-Pin Connector) (18 AWG)<br>NA = 3-inch Cable w/Packard 2P Tower Connector - 12015792 (2-Pin Connector) (18 AWG)<br>PA = 2.75-inch Cable w/Packard 2P Shroud Connector - 12010973 (2-Pin Connector) (18 AWG)<br>RA = 4-inch Cable w/Packard 2P Shroud Connector - 12010973 (2-Pin Connector) (16 AWG)<br>SA = 5.5-inch Cable w/ITT Cannon 2P Sure-Seal Circular Connector - SS2R-120-1804-000 (2-Pin Connector) (18 AWG)<br>WA = 4.5-inch Cable w/Blade Terminals 6,3 mm x 0,8 mm (16 AWG)*<br>XA = 10-inch Cable w/ Metripack 2-Pin Shroud Connector 153000027 (18 AWG)<br>YA = 6-inch Cable w/Amp Super Seal 1.5 - 282104-1 (2-Pin Connector) (18 AWG)*<br>ZA = 10-inch Cable w/Deutsch DT06-2S-CE06 (2-Socket Connector) (18 AWG)<br>AB = Deutsch DT04-2P-E005 (2-Pin Connector)<br>CB = 6-inch Cable w/ AMP Super Seal 1.5 - 282080-1 (2-Pin Connector) (18 AWG)<br>DB = 10-inch Cable w/AMP 2,5 mm System Series Connector 1-967402-1 (18 AWG)*<br>EB = 4.5-inch Cable w/Packard Shroud Connector 12015792 (2-Pin Connector) (18 AWG)<br>FB = 10-inch Cable w/Metripack 150 Delphi 12052641 (2-Pin Connector) (18 AWG)| *These connectors are designed for dual circuit (SPDT) by default. They can be used for single-circuit applications (SPNC/SPNO) by making suitable connections. Refer to wiring diagram. 4 sensing.honeywell.com Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series ## DIMENSIONS - HIGH PRESSURE: HP SERIES (BASE STYLE A), HE SERIES Base Style A key specifications • Life: 2 million (HP), 1 million (HE); Burst pressure: 20,000 psi Figure 1. AMP Superseal 1.5 **==> picture [330 x 130] intentionally omitted <==** **----- Start of picture text -----**<br> 61,64 mm 20,02 mm<br>27 mm [2.427 in] [0.788 in]<br>[1.063] hex A/F<br>(top view) (bottom view)<br>Female Connector Part Number (included): C-282105<br>Male Mating Connector (customer provided): C-282087<br>IP Rating: IP67<br>**----- End of picture text -----**<br> Figure 2. Deutsch **==> picture [328 x 128] intentionally omitted <==** **----- Start of picture text -----**<br> 61,64 mm 21,16 mm<br>27 mm [2.427 in] [0.833 in]<br>[1.063] hex A/F<br>(bottom view)<br>(top view)<br>Female Connector Part Number (included): DT04-3P<br>Male Mating Connector (customer provided): DT06-3S<br>IP Rating: IP67<br>**----- End of picture text -----**<br> Figure 3. Spade Terminal **==> picture [323 x 94] intentionally omitted <==** **----- Start of picture text -----**<br> 27 mm 61,64 mm<br>[1.063] hex A/F [2.427 in] 14,43 mm<br>[0.568 in]<br>(top view) (bottom view)<br>**----- End of picture text -----**<br> Figure 4. Screw Terminal **==> picture [300 x 101] intentionally omitted <==** **----- Start of picture text -----**<br> 61,64 mm<br>27 mm [2.427 in] 12,65 mm<br>[1.063] hex A/F [0.498 in]<br>(top view)<br>**----- End of picture text -----**<br> **(bottom view)** Figure 5. Cable **==> picture [351 x 111] intentionally omitted <==** **----- Start of picture text -----**<br> 61,64 mm 19,51 mm<br>27 mm [2.427 in] [0.768 in]<br>[1.063] hex A/F<br>(top view) (bottom view)<br>IP Rating: IP67<br>**----- End of picture text -----**<br> Safety and Productivity Solutions 5 Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series ## DIMENSIONS - HIGH PRESSURE: HP SERIES (BASE STYLE B) Base Style B key specifications • Life: 1 million; Burst pressure: 9,000 psi ## Figure 6. HP Series Base Style B **==> picture [319 x 128] intentionally omitted <==** **----- Start of picture text -----**<br> 71,47 mm<br>[2.814 in]<br>14,43 mm<br>[0.568 in]<br>HP with smaller port: dimension 2.814 in remains same (bottom view)<br>for all base ports.<br>**----- End of picture text -----**<br> Figure 7. HP Series Pressure Port Dimensions **==> picture [209 x 165] intentionally omitted <==** **----- Start of picture text -----**<br> “H”<br>Thread<br>“H”<br>Thread<br>“Ø D” “Ø D”<br>“A”<br>“H”<br>Thread<br>“Ø D”<br>“Ø C”<br>**----- End of picture text -----**<br> ## Table 3. HP/HE Series Pressure Port Diameters and Heights |Nomenclature Code|Thread|Height “A”|Diameter “ØD”|Diameter “ØC”|Height “H”| |---|---|---|---|---|---| |M|7/16-20 UNF|–|9,25 mm[0.364 in]|–|11 mm [0.433 in]| |C1|1/2-20 UNF|–|10,85 mm[0.427 in]|–|11 mm [0.433 in]| |G2|9/16-18 UNF|–|12,24 mm[0.482 in]|–|12 mm[0.472 in]| |H|3/4-16 UNF|–|16,74 mm [0.66 in]|–|14 mm [0.551 in]| |N|7/8-14 UNF|–|19,6 mm [0.773 in]|–|16 mm [0.630 in]| |T|M10 x 1.0|1,60 mm [0.063 in]|9,25 mm [0.364 in]|13,79 mm [0.543 in]|11 mm [0.433 in]| |E|M12 x 1.5|2,48 mm [0.098 in]|10,85 mm[0.427 in]|16,79 mm [0.661 in]|11 mm [0.433 in]| |F2|M14 x 1.5|2,48 mm [0.098 in]|12,24 mm[0.482 in]|18,8 mm [0.74 in]|12 mm[0.472 in]| |K|M18 x 1.5|2,48 mm [0.098 in]|16,74 mm [0.66 in]|23,8 mm [0.937 in]|14 mm [0.551 in]| |B|1/8-27 NPT|–|10,29 mm [0.405 in]|–|12,497 mm [0.492 in]| |A|1/4-18 NPT|–|13,72 mm [0.540 in]|–|17,63 mm [0.694 in]| 1Port Style C: Switches less than 975 psi will use Base Style B; switches greater than 975 psi will use Base Style A. 2Port Styles F and G: Switches less than 350 psi will use Base Style B; switches greater than 350 psi will use Base Style A. Switches less than 150 psi will use only Base Style B. 6 sensing.honeywell.com Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series ## DIMENSIONS - MEDIUM PRESSURE: MH SERIES Figure 8. AMP Superseal 1.5 **==> picture [228 x 188] intentionally omitted <==** **----- Start of picture text -----**<br> (bottom view) 67,06 mm max.[2.64 in] max.<br>Figure 9. Deutsch 2-pin<br>67,06 mm max.<br>(bottom view) [2.64 in] max.<br>**----- End of picture text -----**<br> Figure 9. Deutsch 2-pin Figure 10. Wire out **==> picture [205 x 95] intentionally omitted <==** **----- Start of picture text -----**<br> (bottom view) 50,29 mm max.<br>[1.98 in] max.<br>**----- End of picture text -----**<br> Figure 11. Blade terminal **==> picture [234 x 205] intentionally omitted <==** **----- Start of picture text -----**<br> 38,35 mm max.<br>(bottom view) [1.51 in] max.<br>Figure 12. Screw terminal<br>38,35 mm max.<br>(bottom view) [1.51 in] max.<br>**----- End of picture text -----**<br> Figure 13. MH Series Pressure Port Dimensions **==> picture [177 x 160] intentionally omitted <==** **----- Start of picture text -----**<br> “A”<br>**----- End of picture text -----**<br> Table 4. MH Series Pressure Port Diameters and Heights **==> picture [266 x 193] intentionally omitted <==** **----- Start of picture text -----**<br> Port Diameter “ØD” Height “H”<br>R 1/2 BSPT 21,34 mm [0.840 in] 17,09 mm [0.673 in]<br>R 1/4 BSPT 13,46 mm [0.530 in] 13,74 mm [0.541 in]<br>R 1/8 BSPT 9,96 mm [0.392 in] 10,24 mm [0.403 in]<br>1/8-27 PTF 10,34 mm [0.407 in] 9,24 mm [0.364 in]<br>1/4-18 NPT 13,72 mm [0.540 in] 17,63 mm [0.694 in]<br>1/8-27 NPT 10,29 mm [0.405 in] 12,497 mm [0.492 in]<br>G 1/4 BSPP 11,1 mm [0.437 in] 11,20 mm [0.441 in]<br>G 1/8 BSPP 8,28 mm [0.326 in] 7,59 mm [0.299 in]<br>3/4-16 UNF 16,74 mm [0.659 in] 11,1 mm [0.437 in]<br>7/16-20 UNF 9,25 mm [0.364 in] 9,09 mm [0.358 in]<br>9/16-18 UNF 12,24 mm [0.482 in] 10,00 mm[0.394 in]<br>1/2-20 UNF 10,85 mm [0.427 in] 9,09 mm [0.358 in]<br>**----- End of picture text -----**<br> |Port|Height<br>“A”|Diameter<br>“ØC”|Diameter<br>“ØD”|Height “H”| |---|---|---|---|---| |M14 × 1.5|2,49 mm<br>[0.098 in]|18,8 mm<br>[0.74 in]|11,71 mm<br>[0.461 in]|10,998 mm<br>[0.433 in]| |M12 × 1.5|2,49 mm<br>[0.098 in]|16,79 mm<br>[0.661 in]|9,70 mm<br>[0.382 in]|10,998 mm<br>[0.433 in]| |M10 × 1.0|1,6 mm<br>[0.063 in]|13,79 mm<br>[0.543 in]|8,41 mm<br>[0.331 in]|8,51 mm<br>[0.335 in]| Safety and Productivity Solutions 7 Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series ## DIMENSIONS - MEDIUM PRESSURE: ME SERIES Figure 14. AMP Superseal 1.5 **==> picture [229 x 321] intentionally omitted <==** **----- Start of picture text -----**<br> 65,3 mm max.<br>(bottom view) [2.57 in] max.<br>Female connector part number (included): C-282105<br>Male mating connector (customer provided): C-282087<br>IP rating: IP67<br>Figure 15. Deutsch 3-pin<br>64 mm max.<br>(bottom view) [2.52 in] max.<br>Female connector part number (included): DT04-3P<br>Male mating connector (customer provided): DT06-3S<br>IP rating: IP67<br>Figure 16. Deutsch 2-pin<br>65,5 mm max.<br>(bottom view) [2.58 in] max.<br>Female connector part number (included): DT04-2P<br>Male mating connector (customer provided): DT06-2S<br>IP rating: IP67<br>**----- End of picture text -----**<br> Figure 17. Wire out **==> picture [231 x 286] intentionally omitted <==** **----- Start of picture text -----**<br> 48,51 mm max.<br>(bottom view) [1.91 in] max.<br>IP rating: IP67<br>Figure 18. Blade terminal<br>(bottom view) 38,9 mm max.<br>[1.57 in] max.<br>Figure 19. Screw terminal<br>(bottom view) 38,9 mm max.<br>[1.57 in] max.<br>**----- End of picture text -----**<br> Figure 20. ME Series Pressure Port Dimensions **==> picture [210 x 191] intentionally omitted <==** **----- Start of picture text -----**<br> H<br>H<br>ØD<br>ØD<br>A<br>H<br>ØD<br>ØC<br>**----- End of picture text -----**<br> Table 5. ME Series Pressure Port Diameters and Heights **==> picture [266 x 308] intentionally omitted <==** **----- Start of picture text -----**<br> Port Diameter “ØD” Height “H”<br>R 1/2 BSPT 21,34 mm [0.840 in] 17,09 mm [0.673 in]<br>R 1/4 BSPT 13,46 mm [0.530 in] 13,74 mm [0.541 in]<br>R 1/8 BSPT 9,96 mm [0.392 in] 10,24 mm [0.403 in]<br>1/8-27 PTF 10,34 mm [0.407 in] 9,24 mm [0.364 in]<br>1/4-18 NPT 13,72 mm [0.540 in] 17,63 mm [0.694 in]<br>1/8-27 NPT 10,29 mm [0.405 in] 12,497 mm [0.492 in]<br>G 1/4 BSPP 11,1 mm [0.437 in] 11,20 mm [0.441 in]<br>G 1/8 BSPP 8,28 mm [0.326 in] 7,59 mm [0.299 in]<br>3/4-16 UNF 16,74 mm [0.659 in] 11,1 mm [0.437 in]<br>7/16-20 UNF 9,25 mm [0.364 in] 9,09 mm [0.358 in]<br>9/16-18 UNF 12,24 mm [0.482 in] 10,00 mm[0.394 in]<br>1/2-20 UNF 10,85 mm [0.427 in] 9,09 mm [0.358 in]<br>Height Diameter Diameter<br>Port Height “H”<br>“A” “ØC” “ØD”<br>2,49 mm 18,8 mm 11,71 mm 10,998 mm<br>M14 × 1.5<br>[0.098 in] [0.74 in] [0.461 in] [0.433 in]<br>2,49 mm 16,79 mm 9,70 mm 10,998 mm<br>M12 × 1.5<br>[0.098 in] [0.661 in] [0.382 in] [0.433 in]<br>1,6 mm 13,79 mm 8,41 mm 8,51 mm<br>M10 × 1.0<br>[0.063 in] [0.543 in] [0.331 in] [0.335 in]<br>**----- End of picture text -----**<br> 8 sensing.honeywell.com Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series ## DIMENSIONS - LOW PRESSURE: LP SERIES, LE SERIES **==> picture [230 x 91] intentionally omitted <==** **----- Start of picture text -----**<br> Figure 21. AMP Superseal 1.5<br>58,93 mm max.<br>(bottom view) [2.32 in] max.<br>**----- End of picture text -----**<br> Figure 22. Deutsch 3-pin **==> picture [231 x 419] intentionally omitted <==** **----- Start of picture text -----**<br> (bottom view) 57,66 mm max.[2.27 in] max.<br>Figure 23. Deutsch 2-pin<br>(bottom view) 58,93 mm max.[2.32 in] max.<br>Figure 24. Wire out<br>42,16 mm max.<br>(bottom view) [1.66 in] max.<br>IP rating: IP67<br>Figure 25. Spade terminal<br>(bottom view) 33,02 mm max.[1.30 in] max.<br>**----- End of picture text -----**<br> Figure 27. LP/LE Series Pressure Port Dimensions **==> picture [210 x 192] intentionally omitted <==** **----- Start of picture text -----**<br> H<br>H<br>ØD<br>ØD<br>A<br>H<br>ØD<br>ØC<br>**----- End of picture text -----**<br> Table 6. LP/LE Series Pressure Port Diameters and Heights **==> picture [266 x 308] intentionally omitted <==** **----- Start of picture text -----**<br> Port Diameter “ØD” Height “H”<br>R 1/2 BSPT 21,34 mm [0.840 in] 17,09 mm [0.673 in]<br>R 1/4 BSPT 13,46 mm [0.530 in] 13,74 mm [0.541 in]<br>R 1/8 BSPT 9,96 mm [0.392 in] 10,24 mm [0.403 in]<br>1/8-27 PTF 10,34 mm [0.407 in] 9,24 mm [0.364 in]<br>1/4-18 NPT 13,72 mm [0.540 in] 17,63 mm [0.694 in]<br>1/8-27 NPT 10,29 mm [0.405 in] 12,497 mm [0.492 in]<br>G 1/4 BSPP 11,1 mm [0.437 in] 11,20 mm [0.441 in]<br>G 1/8 BSPP 8,28 mm [0.326 in] 7,59 mm [0.299 in]<br>3/4-16 UNF 16,74 mm [0.659 in] 11,1 mm [0.437 in]<br>7/16-20 UNF 9,25 mm [0.364 in] 9,09 mm [0.358 in]<br>9/16-18 UNF 12,24 mm [0.482 in] 10,00 mm [0.394 in]<br>1/2-20 UNF 10,85 mm [0.427 in] 9,09 mm [0.358 in]<br>Height Diameter Diameter<br>Port Height “H”<br>“A” “ØC” “ØD”<br>2,49 mm 18,8 mm 11,71 mm 10,998 mm<br>M14 × 1.5<br>[0.098 in] [0.74 in] [0.461 in] [0.433 in]<br>2,49 mm 16,79 mm 9,70 mm 10,998 mm<br>M12 × 1.5<br>[0.098 in] [0.661 in] [0.382 in] [0.433 in]<br>1,6 mm 13,79 mm 8,41 mm 8,51 mm<br>M10 × 1.0<br>[0.063 in] [0.543 in] [0.331 in] [0.335 in]<br>**----- End of picture text -----**<br> Figure 26. Screw terminal **==> picture [188 x 64] intentionally omitted <==** **(bottom view)** **==> picture [69 x 15] intentionally omitted <==** **----- Start of picture text -----**<br> 33,02 mm max.<br>[1.30 in] max.<br>**----- End of picture text -----**<br> Safety and Productivity Solutions 9 Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series ## DIMENSIONS - 1000 SERIES, 5000 SERIES Figure 28. 1000 Series Dimensions **==> picture [350 x 530] intentionally omitted <==** **----- Start of picture text -----**<br> 11,18 mm [0.44 in] min.<br>last full thread ref. 12,4 mm<br>[0.488 in]<br>6,02 mm<br>[0.237 in]<br>31,5 mm 33,1 mm<br>[1.24 in] [1.303 in]<br>65,6 mm<br>[2.583 in]<br>55,11 mm<br>[2.17 in]<br>34,85 mm<br>[1.37 in] 5,5 mm<br>[0.22 in]<br>M 10 x 1.25 -6G<br>45°<br>45°<br>3,2 mm 2X 9,91 mm<br>[0.13 in] [0.39 in]<br>8,99 mm<br>[0.35 in]<br>1,5 x 45°<br>2,1 mm Ø2,5 cross drill<br>[0.08 in] 0.25 x 45° chamfer<br>Figure 29. 5000 Series Dimensions<br>8-32 x 1/4 screw (3)<br>1/8-27 NPT<br>0.500 hex ref.<br>Ø 37,34 mm<br>[Ø 1.47 in]<br>ref.<br>58,42 mm<br>[2.3 in] ref.<br>**----- End of picture text -----**<br> 10 sensing.honeywell.com Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series ## NOMENCLATURE: HIGH PRESSURE For example, HPR05500PFNSPAAA01 defines a high pressure switch, rising factory set, non-adjustable set point, 550 psi set point, psig, sealed gage pressure unit, M14 x 1.5 port type, SPST-NO silver contacts output, cold-rolled steel base, glycol-based fluid (EPDM) actuation/application, spade terminal connectors, standard switch, individually boxed units. **HP R 05500 P F N S P AA A 01** Pressure Pressure Actuation/ Connector Packaging Series Set Point Set Point Unit Port Type Output Base Application Type Options Options **HP SeriesHE Series R** Risingfactory set, non-adjustable 6,89 bar to 310,26 bar[100 psi to 4500 psi] **P** psig,sealed gage **A** 1/4-18 NPT **N** SPST-NO,silver contacts **S** Cold-rolledsteel **N** Petroleum-basedhydraulic fluid (Nitrile) **AA** 1/4 in SpadeTerminals* **A** Standardswitch **01**[Individually ] boxed units* (100 psi to 4500 psi),PressureSwitchHigh **NOTE: Set point below 100 psiis available only withHP Series (Body Style B).F** Fallingfactory set,non-adjustable value will be multiplied by 100 and entered in the listing. For example, **NOTE: Pressure set point is always five digits.** For bar, the set point **B** bar,sealed gage **BCE** 1/8-27 NPTM12 x 1.51/2-20 UNF **CDH** SPST-NC,silver contactsSPDT-NO/NC,silver contactsNO, gold inlay contacts EDPM O-ring option only availablefrom 100 psi to 250 psi. **P** Glycol-basedfluid (EPDM) **BACADA** ScrewTerminals*Deutsch DT04-3P-E005 (3-Pin Connector)*Amp Super Seal 1.5 - 282105-1 (3-Pin Connector)* **CBD** With 3 shrink sleeveWith shrink sleeve (plastic coating)With shrink sleeve (acrylic coating) **021516** Individually boxed units**25 individual boxes packed in bulk 25 individual boxes packed in bulk packaging**packaging* 15,45 Bar is noted as 01545. This allows for 2 decimal places. **F** M14 x 1.5 **J** NC, gold inlay contacts **EA** 10-inch Cable, 18 AWG (Wire Out, No Connector) **F** 304,8 mm [12 in]total wire length **20** 50 individual boxes packed in bulk packaging* For psi, the set point value will be multiplied **G** 9/16-18 UNF **K** SPDT(NO/NC), gold inlay contacts **FA** 10-inch Cable w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)* **G** With conduit sleeve **21** 50 individual boxes packed in bulk packaging** by 10 and entered in the listing. For example,245.5 psi is noted as 02455. **H** 3/4-16 UNF **E** NO, with 510 0.5 W & 160 0.5 W resistorsΩΩ// **GA** 10-inch Cable w/Amp Super Seal 1.5 - 282105-1 (3-Pin Connector) (18 AWG)* **H**[With Vibra seal for] port threads **25** 25 units in bulk packaging* This allows for 1 decimal place. **K** M18 x 1.5 **F** NC, with 3000 0.125 W resistorΩ/ **HA** 10-inch Cable w/Metripack 280 Delphi 15300002 (2-Pin Connector) (18 AWG) **J** #8-32 screw withexternal toothlockwasher* 26** 25 units in bulk packaging M** 7/16-20 UNF **JA** 10-inch Cable w/Din43650-C (3-Pin Connector) (18 AWG)* **K** 914,4 mm [36 in]total wire length **50** 50 individual parts inbulk packaging* **NT** M10 x 1.07/8-14 UNF **LAKA** 10-inch Cable w/Packard Weatherpack Male Terminal - 12020827 (3-Pin Connector) (18 AWG)*10-inch Cable w/M12x1 (Brad Harrison Micro) - 21032121306 Harting P/N (3-Pin Connector) (18 AWG)* *** For screw terminal optiononly **ML** 304,8 mm [12 in]total wire length withacrylic sleeve914,4 mm [36 in]total wire length withacrylic sleeve * Not applicable for HPSeries (Base Style B)** Not applicable for HP (Base Style A) & HE Series HP Series Port Types **MA** 10-inch Cable w/Deutsch DT04-2P-E005 Thread Type Base Style A Base Style B 3-inch Cable w/Packard 2P (2-Pin Connector) (18 AWG) A = 1/4-18 NPT n/a 100 psi to 4500 psi **NA** Tower Connector - 12015792 (2-Pin Connector) (18 AWG) B = 1/8-27 NPT n/a 100 psi to 4500 psi 2.75-inch Cable w/Packard C = 1/2-20 UNF >975 psi n/a **PA** 2P Shroud Connector - 12010973 (2-Pin Connector) (18 AWG) E = M12 x 1.5F = M14 x 1.5 n/a>350 psi 100 n/a psi to 4500 psi **RA** 4-inch Cable w/Packard 2P Shroud Connector - 12010973 (2-Pin Connector) (16 AWG) G = 9/16-18 UNF >350 psi <350 psi 5.5-inch Cable w/ITT Cannon 2P Sure-Seal **SA** Circular Connector - H = 3/4-16 UNF >150 psi <150 psi SS2R-120-1804-000 (2-Pin Connector) (18 AWG) K = M18 x 1.5 150 psi to 4500 psi n/a 8.5-inch Cable w/ITT Cannon 3P Sure-Seal M = 7/16-20 UNFN = 7/8-14 UNF n/a150 psi to 4500 psi 100 n/a psi to 4500 psi **TA** Circular Connector - SS3R-120-8551-001 (3-Pin Connector10-inch Cable - Vacuum ) (16 AWG)* Impregnated w/Deutsch ~~_-~~ T = M10 x 1.0 n/a 100 psi to 4500 psi **UA** DT06-3S-EP06 (3-Socket Connector) (16 AWG)* Port Type A, B, E, M, and T will be available only with HP Series. 10-inch Cable - Vacuum Base Style B will be available only with HP Series **VA** Impregnated w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)* 4.5-inch Cable w/ 1/4 in **WA** Spade Terminals 6,3 mm x 0,8 mm (16 AWG) 10-inch Cable w/ Metripack **XA** 2-Pin Shroud Connector 153000027 (18 AWG) 6-inch Cable w/Amp **YA** Super Seal 1.5 - 282104-1 (2-Pin Connector) (18 AWG) 10-inch Cable w/Deutsch **ZA** DT06-2S-CE06 (2-Socket Connector) (18 AWG) 10-inch Cable w/Metripack **BB** 150 Delphi 12129615 (3-Pin Connector) (18 AWG) 6-inch Cable w/ AMP Super **CB** Seal 1.5 - 282080-1 (2-Pin Connector) (18 AWG) 10-inch Cable w/AMP 2,5 mm **DB** System Series Connector 1-967402-1 (18 AWG)* 4.5-inch Cable w/Packard **EB** Shroud Connector 12015792 (2-Pin Connector) (18 AWG) 10-inch Cable w/Metripack **FB** 150 Delphi 12052641 (2-Pin Connector) (18 AWG) 8.5-inch Cable w/Deutsch **GB** Plug HD 16-3 96S (3-Pin Connector) (16 AWG)* *These connectors are designed for dual circuit (SPDT) by default. They can be used for single-circuit applications (SPNC/SPNO) by making suitable connections. Refer to wiring diagram. Safety and Productivity Solutions 11 Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series ## NOMENCLATURE: MEDIUM PRESSURE, HIGH BURST For example, MHR01500PFPVMAAA01 defines a medium pressure, high burst switch, rising factory set, non-adjustable set point, 150 psi set point, psig, sealed gage pressure unit, 1/4-18 NPT port type, SPST-NO contacts output, stainless steel base, LTNB diaphragm, and spade terminal connectors. **MH R 01500 P A P N M AA A 01** Pressure Pressure Actuation/ Connector Packaging Series Set Point Set Point Unit Port Type Output Base Application Type Options Options **MH Series** Medium ie **R** Risingfactory set, non-adjustable oe 0,24 bar to 10,34 bar[3.5 psi to 150 psi] oe **P** psig,sealed gage oe **A** 1/4-18 NPT oe **P** SPST-NO **N** Cold-rolledsteel **M** LTNB diaphragm(Low-temp Buna N) **AA** 1/4 in SpadeTerminals ee **A** Standardswitch e **01**[Individually ] boxed units PressureSwitch **FT** Rising, field adjustable*Fallingfactory set,non-adjustable value will be multiplied **NOTE: Pressure set point is always five digits.** For bar, the set point **BM** bar,sealed gagebar,true gage* **BC** 1/8-27 NPT1/2-20 UNF **M** SPST-NC **BV**[Brass] Stainlesssteel **NE** HNBR diaphragm(Hydrogenated Nitrile Butadiene RubberEPDM diaphragm(Ethylene-Propylene-Diene Monomer) ) **BADA** ScrewTerminalsAmp Super Seal 1.5 - 282105-1 (3-Pin Connector) **CD** With shrink sleeve (plastic coating)With shrink sleeve (acrylic coating) **1520** 25 individual boxes packed in bulk packaging150 units in bulk packaging **C** Falling,field adjustable* 15,45 Bar is noted as by 100 and entered in the listing. For example, **T** psig,true gage* **D** 1/8-27 PTF **EA** 10-inch Cable, 18 AWG (Wire Out, No Connector) **F** 304,8 mm [12 in]total wire length **25** 25 units in bulk packaging (SPNO & SPNC)* Field adjustable option is onlyavailable for: 1. Blade and screw terminations (SPDT, SPNO, SPNC)2. Deutsch DT04-3P (SPDT, SPNO, SPNC)3. Amp Superseal 1.5 (3-pin) This allows for 1 decimal place.01545. This allows for 2 decimal places.For psi, the set point value will be multiplied by 10 and entered in the listing. For example,245.5 psi is noted as 02455. *Blade and screw electricalterminations are availablewith only the the true gageoption.**Connector cavity and rollforming area filled with epoxy **GH** psig,sealed gagewith epoxy**bar,sealed gagewith epoxy EFGH** M12 x 1.5M14 x 1.59/16-18 UNF3/4-16 UNF **HAMANAPA** 3-inch Cable w/Packard 2P Tower Connector - 12015792 (2-Pin Connector) (18 AWG)10-inch Cable w/Metripack 280 Delphi 15300002 (2-Pin Connector) (18 AWG)*10-inch Cable w/Deutsch DT04-2P-E005 (2.75-inch Cable w/Packard 2P Shroud Connector - 12010973 (2-Pin Connector) 2-Pin Connector) (18 AWG) **GHJK**[With conduit ] sleeveWith Vibra sealfor threads#8-32 screw withexternal toothlockwasher***914,4 mm [36 in]total wire length **30** 150 individualboxes packed in bulk packaging to meet dunk test sealing (18 AWG) 304,8 mm [12 in] capability. **J** G1/8 BSPP 4-inch Cable w/Packard **L** total wire lengthw/ shrink sleeve **RA** 2P Shroud Connector - 12010973 (2-Pin Connector) 914,4 mm [36 in] **L** 3/8-24 UNF (16 AWG) **M** total wire lengthw/ shrink sleeve 5.5-inch Cable w/ITT **M** 7/16-20 UNF **SA** Cannon 2P Sure-Seal Circular Connector - ***applicable only forscrew terminal version. SS2R-120-1804-000 (2-Pin Connector) (18 AWG) **P** 1/2-14 NPT **WA** 4.5-inch Cable w/ 1/4 in Spade Terminals 6,3 mm x 0,8 mm (16 AWG)* **R** R1/8 BSPT 10-inch Cable w/ Metripack **XA** 2-Pin Shroud Connector 153000287 (18 AWG) **T** M10 × 1.0 6-inch Cable w/Amp **YA** Super Seal 1.5 - 282104-1 (2-Pin Connector) (18 AWG)* **V** R1/2 BSPT **ZA** 10-inch Cable w/Deutsch DT06-2S-CE06 (2-Socket Connector) (18 AWG) **Y** G1/4 BSPP **AB** Deutsch DT04-2P-E005 (2-Pin Connector) **Z** R1/4 BSPT **CB** 6-inch Cable with AmpSuper Seal 1.5 - 282080-1 (2-Pin Connector) (18 AWG) 10-inch Cable w/AMP 2,5 mm **DB** System Series Connector 1-967402-1 (18 AWG)* 4.5-inch Cable w/Packard **EB** Shroud Connector 12015792 (2-Pin Connector) (18 AWG) 10-inch Cable w/Metripack **FB** 150 Delphi 12052641 ~~“TT~~ (2-Pin Connector) (18 AWG) *These connectors are designed for dual circuit (SPDT) by default. They can be used for single-circuit applications (SPNC/SPNO) by making suitable connections. Refer to wiring diagram. 12 sensing.honeywell.com Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series ## NOMENCLATURE: MEDIUM PRESSURE For example, MER01500PFPVKAAA01 defines a medium pressure switch, rising factory set, non-adjustable set point, 55 psi set point, psig, sealed gage pressure unit, M14 x 1.5 port type, SPST-NO gold-plated contacts output, stainless steel base, Kapton[®] diaphragm (Teflon[®] coated), Nitrile O-ring actuation/application, spade terminal connectors, standard switch, individually boxed units. |**ME**<br>Series||Set Point<br>**R**||Pressure<br>Set Point<br>**01500**||Pressure<br>Unit<br>**P**|Pressure<br>Unit<br>**P**|**F**<br>Port Type|**F**<br>Port Type||**P**<br>Output||Base<br>**V**||**K**<br>Actuation/<br>Application||**AA**<br>Connector<br>Type||Options<br>**A**||Packaging<br>Options<br>**01**| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |**ME Series**<br>Medium|**R**|Rising<br>factory set,<br>non-adjustable|1,72 bar to 24,13 bar<br>[25 psi to 350 psi]||**P**||psig,<br>sealed gage|**A**|1/4-18 NPT|**P**|SPST-NO,<br>gold-plated contacts|**N**|Cold-rolled<br>steel with<br>zinc plating|**K**|Kapton®diaphragm<br>(Teflon®coated),<br>Nitrile O-ring1|**AA**|1/4 in Spade<br>Terminals|**A**|Standard<br>switch|**01**|Individually<br>boxed units| |Pressure<br>Switch|**F**<br>**T**|Falling<br>factory set,<br>non-adjustable<br>Rising,<br>field adjustable*|**NOTE:**<br>**Pressure set point**<br>**is always five digits.**<br>For bar, the set point<br>value will be multiplied||**B**<br>**M**||bar,<br>sealed gage<br>bar,<br>true gage|**C**<br>**B**|1/2-20 UNF<br>1/8-27 NPT|**Y**<br>**M**|SPST-NC,<br>gold-plated contacts<br>SPDT-NO/NC,<br>gold-plated contacts|**V**|Stainless<br>steel|**H**<br>Kapton®diaphragm<br>(Teflon®coated),<br>EPDM O-ring2<br>1Air, Petroleum-based<br>hydraulic fluid, engine oil<br>2Glycol-based fluid||**CA**<br>**BA**|Screw<br>Terminals<br>Deutsch DT04-3P-E005<br>(3-Pin Connector)|**B**<br>**C**|With 3 shrink<br>sleeve<br>With shrink<br>sleeve<br>(plastic coating)|**15**<br>**20**|150 units in<br>bulk packaging<br>25 individual<br>boxes packed in<br>bulk packaging| ||**C**|Falling,<br>field adjustable*|by 100 and entered<br>in the listing. For example,<br>15,45 Bar is noted as<br>01545. This allows for||**T**||psig,<br>true gage|**D**|1/8-27 PTF|**E**|NO, with 510Ω/<br>0.5 W & 160Ω/<br>0.5 W resistors|||||**DA**|Amp Super Seal 1.5 -<br>282105-1<br>(3-Pin Connector)|**D**|With shrink<br>sleeve<br>(acrylic coating)|**25**|25 units in<br>bulk packaging| ||* Field adjustable option is only<br>available for:<br>1. Blade and screw terminations<br>(SPDT, SPNO, SPNC)<br>2. Deutsch DT04-3P<br>(SPDT, SPNO, SPNC)<br>3. Amp Superseal 1.5 (3-pin)<br>(SPNO & SPNC)||2 decimal places.<br>For psi, the set point<br>value will be multiplied<br>by 10 and entered<br>in the listing. For example,<br>245.5 psi is noted as 02455.<br>This allows for 1 decimal place.||Blade and screw electrical<br>terminations are available<br>with only the the true gage<br>**G**<br>psig,<br>sealed gage<br>with epoxy<br>**H**<br>bar,<br>sealed gage<br>with epoxy|||**E**<br>**F**<br>**G**|M14 x 1.5<br>M12 x 1.5<br>9/16-18 UNF|**F**|NC, with 3000Ω/<br>0.125 W resistor|||||**FA**<br>**GA**<br>**EA**|10-inch Cable, 18 AWG<br>(Wire Out, No Connector)<br>10-inch Cable w/Amp<br>Super Seal 1.5 - 282105-1<br>(3-Pin Connector) (18 AWG)*<br>10-inch Cable w/Deutsch<br>DT04-3P-E005<br>(3-Pin Connector) (16 AWG)*|**F**<br>**G**<br>**E**|304,8 mm [12 in]<br>total wire length<br>With conduit<br>sleeve<br>With 1/8 W resistor<br>between terminals|**30**|150 individual<br>boxes packed in<br>bulk packaging| ||||||option.|||**H**|3/4-16 UNF|||||||**HA**|10-inch Cable w/Metripack<br>280 Delphi 15300002<br>(2-Pin Connector) (18 AWG)*|**H**|With Vibra seal<br>for port threads||| |||||||||**J**|G1/8 BSPP|||||||**JA**|10-inch Cable w/<br>Din43650-C<br>(3-Pin Connector) (18 AWG)*|**J**|#8-32 screw with<br>external tooth<br>lockwasher||| |||||||||**M**|7/16-20 UNF|||||||**KA**|10-inch Cable w/M12x1<br>(Brad Harrison Micro) -<br>21032121306 Harting P/N|**K**|914,4 mm [36 in]<br>total wire length||| ||||||||||||||||||(3-Pin Connector) (18 AWG)*||||| |||||||||**R**<br>**T**|R1/8 BSPT<br>M10 × 1.0|||||||**LA**|10-inch Cable w/Deutsch<br>10-inch Cable w/Packard<br>Weatherpack Male Terminal -<br>12020827 (3-Pin Connector)<br>(18 AWG)*|**R**<br>*** For screw terminal option<br>only|With port neck<br>O-ring for LPS<br>*** For screw terminal option||| |||||||||**V**|R1/2 BSPT|||||||**MA**|DT04-2P-E005<br>(2-Pin Connector) (18 AWG)<br>3-inch Cable w/Packard 2P||||| |||||||||||||||||**NA**|Tower Connector -<br>12015792 (2-Pin Connector)||||| |||||||||**Y**|G1/4 BSPP||||||||(18 AWG)||||| ||||||||||||||||||2.75-inch Cable w/Packard||||| |||||||||**Z**|R1/4 BSPT|||||||**PA**|2P Shroud Connector -<br>12010973 (2-Pin Connector)<br>(18 AWG)||||| ||||||||||||||||||4-inch Cable w/Packard||||| |||||||||||||||||**RA**|2P Shroud Connector -<br>12010973 (2-Pin Connector)||||| ||||||||||||||||||(16 AWG)||||| ||||||||||||||||||5.5-inch Cable w/ITT||||| |||||||||||||||||**SA**|Cannon 2P Sure-Seal<br>Circular Connector -<br>SS2R-120-1804-000 (2-Pin||||| ||||||||||||||||||Connector) (18 AWG)||||| ||||||||||||||||||8.5-inch Cable w/ITT||||| |||||||||||||||||**TA**|Cannon 3P Sure-Seal<br>Circular Connector -||||| ||||||||||||||||||SS3R-120-8551-001 (3-Pin||||| ||||||||||||||||||Connector) (16 AWG)*||||| ||||||||||||||||||10-inch Cable - Vacuum||||| |||||||||||||||||**UA**|Impregnated w/Deutsch<br>DT06-3S-EP06 (3-Socket||||| ||||||||||||||||||Connector) (16 AWG)*||||| ||||||||||||||||||10-inch Cable - Vacuum||||| |||||||||||||||||**VA**|Impregnated w/Deutsch<br>DT04-3P-E005 (3-Pin||||| ||||||||||||||||||Connector) (16 AWG)*||||| |||||||||||||||||**WA**|4.5-inch Cable w/ 1/4 in<br>Spade Terminals 6,3 mm x||||| ||||||||||||||||||0,8 mm (16 AWG)*||||| |||||||||||||||||**XA**|10-inch Cable w/ Metripack<br>2-Pin Shroud Connector<br>153000287 (18 AWG)||||| |||||||||||||||||**YA**|6-inch Cable w/Amp<br>Super Seal 1.5 - 282104-1<br>(2-Pin Connector) (18 AWG)*||||| ||||||||||||||||||10-inch Cable w/Deutsch||||| |||||||||||||||||**ZA**|DT06-2S-CE06 (2-Socket<br>Connector) (18 AWG)||||| |||||||||||||||||**AB**|Deutsch DT04-2P-E005<br>(2-Pin Connector)||||| |||||||||||||||||**BB**|10-inch Cable w/Metripack<br>150 Delphi 12129615<br>(3-Pin Connector) (18 AWG)*||||| |||||||||||||||||**CB**|6-inch Cable with Amp<br>Super Seal 1.5 - 282080-1<br>(2-Pin Connector) (18 AWG)||||| |||||||||||||||||**DB**|10-inch Cable w/AMP 2,5 mm<br>System Series Connector<br>1-967402-1(18 AWG)*||||| ||||||||||||||||||4.5-inch Cable w/Packard||||| |||||||||||||||||**EB**|Shroud Connector 12015792<br>(2-Pin Connector) (18 AWG)||||| |||||||||||||||||**FB**|10-inch Cable w/Metripack<br>150 Delphi 12052641<br>(2-Pin Connector) (18 AWG)||||| |||||||||||||||||**GB**|8.5-inch Cable w/Deutsch<br>Plug HD 16-3 96S<br>(3-Pin Connector) (16 AWG)||||| *These connectors are designed for dual circuit (SPDT) by default. They can be used for single-circuit applications (SPNC/SPNO) by making suitable connections. Refer to wiring diagram. Safety and Productivity Solutions 13 Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series ## NOMENCLATURE: LOW PRESSURE For example, LPR00550PFPVKAAA01 defines a low pressure switch, rising factory set, non-adjustable set point, 55 psi set point, psig, sealed gage pressure unit, M14 x 1.5 port type, SPST-NO gold-plated contacts output, stainless steel base, Kapton[®] diaphragm (Teflon[®] coated), Nitrile O-ring actuation/application, spade terminal connectors, standard switch, individually boxed units. |**LP**<br>Series||Set Point<br>**R**||Pressure<br>Set Point<br>**00550**||Pressure<br>Unit<br>**P**|Pressure<br>Unit<br>**P**|**F**<br>Port Type|**F**<br>Port Type||**P**<br>Output||Base<br>**V**||**K**<br>Actuation/<br>Application||**AA**<br>Connector<br>Type||Options<br>**A**||Packaging<br>Options<br>**01**| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |**LP Series,**<br>**LE Series**|**R**|Rising<br>factory set,<br>non-adjustable|0,24 bar to 10,34 bar<br>[3.5 psi to 150 psi]||**P**||psig,<br>sealed gage|**A**|1/4-18 NPT|**P**|SPST-NO,<br>gold-plated contacts|**B**|Brass|**K**|Kapton®diaphragm<br>(Teflon®coated),<br>Nitrile O-ring1|**AA**|1/4 in Spade<br>Terminals|**A**|Standard<br>switch|**01**|Individually<br>boxed units| |Low<br>Pressure<br>Switch|**F**<br>**T**|Falling<br>factory set,<br>non-adjustable<br>Rising,<br>field adjustable*|**NOTE:**<br>**Pressure set point**<br>**is always five digits.**<br>For bar, the set point<br>value will be multiplied||**B**<br>**M**||bar,<br>sealed gage<br>bar,<br>true gage|**C**<br>**B**|1/2-20 UNF<br>1/8-27 NPT|**Y**<br>**M**|SPST-NC,<br>gold-plated contacts<br>SPDT-NO/NC,<br>gold-plated contacts|**N**<br>**V**|Cold-rolled<br>steel with<br>zinc plating<br>Stainless<br>steel|**H**<br>**T**|Kapton®diaphragm<br>(Teflon®coated),<br>EPDM O-ring2<br>Tefzel®and Kapton®<br>diaphragm,<br>Nitrile O-ring3|**CA**<br>**BA**|Screw<br>Terminals<br>Deutsch DT04-3P-E005<br>(3-Pin Connector)|**B**<br>**C**|With 3 shrink<br>sleeve<br>With shrink<br>sleeve<br>(plastic coating)|**15**<br>**20**|150 units in<br>bulk packaging<br>25 individual<br>boxes packed in<br>bulk packaging| ||**C**|Falling,<br>field adjustable*|by 100 and entered<br>in the listing. For example,<br>15,45 Bar is noted as<br>01545. This allows for||**T**||psig,<br>true gage|**D**|1/8-27 PTF|**E**|NO, with 510Ω/<br>1 W & 160Ω/<br>1 W resistors****|||**U**|Tefzel®and Kapton®<br>diaphragm,<br>EPDM O-ring4|**DA**|Amp Super Seal 1.5 -<br>282105-1<br>(3-Pin Connector)**|**D**|With shrink<br>sleeve<br>(acrylic coating)|**25**|25 units in<br>bulk packaging| ||* Field adjustable option is only<br>available for:<br>1. Blade and screw terminations<br>(SPDT, SPNO, SPNC)<br>2. Deutsch DT04-3P<br>(SPDT, SPNO, SPNC)<br>3. Amp Superseal 1.5 (3-pin)<br>(SPNO & SPNC)||2 decimal places.<br>For psi, the set point<br>value will be multiplied<br>by 10 and entered<br>in the listing. For example,<br>245.5 psi is noted as 02455.<br>This allows for 1 decimal place.||Blade and screw electrical<br>terminations are available<br>with only the the true gage<br>**G**<br>psig,<br>sealed gage<br>with epoxy<br>**H**<br>bar,<br>sealed gage<br>with epoxy|||**E**<br>**F**<br>**G**|M14 x 1.5<br>M12 x 1.5<br>9/16-18 UNF|**F**<br>NC, with 3000Ω/<br>0.125 W resistor<br>**G**<br>NC with 510Ω/<br>0.5 W and 160Ω/<br>0.5 W resistors****<br>**** Available only on LP Series||||1Air, Petroleum-based<br>hydraulic fluid, engine oil<br>2Glycol-based fluid<br>3For high temperature<br>fluid media**(LE Series only)**<br>4For high temperature<br>fluid media, glycol-based<br>fluid**(LE Series only)**||**FA**<br>**GA**<br>**EA**|10-inch Cable, 18 AWG<br>(Wire Out, No Connector)*<br>10-inch Cable w/Amp<br>Super Seal 1.5 - 282105-1<br>(3-Pin Connector) (18 AWG)*<br>10-inch Cable w/Deutsch<br>DT04-3P-E005<br>(3-Pin Connector) (16 AWG)*|**F**<br>**G**<br>**H**|304,8 mm [12 in]<br>total wire length<br>With conduit<br>sleeve<br>With Vibra seal<br>for port threads|**30**|150 individual<br>boxes packed in<br>bulk packaging| ||||||option.<br>True gage option is available<br>only up to 20 psig set<br>point for integral connectors<br>and wire out electrical<br>terminations.|||**J**<br>**H**|G1/8 BSPP<br>3/4-16 UNF|||||||**HA**<br>**JA**|10-inch Cable w/Metripack<br>280 Delphi 15300002<br>(2-Pin Connector) (18 AWG)*<br>10-inch Cable w/<br>Din43650-C<br>(3-Pin Connector) (18 AWG)*|**K**<br>**L**|914,4 mm [36 in]<br>total wire length<br>304,8 mm [12 in]<br>total wire length with<br>acrylic sleeve||| |||||||||**M**|7/16-20 UNF|||||||**KA**|10-inch Cable w/M12x1<br>(Brad Harrison Micro) -<br>21032121306 Harting P/N|**M**|914,4 mm [36 in]<br>total wire length with<br>acrylic sleeve||| |||||||||**R**|R1/8 BSPT|||||||**LA**|(3-Pin Connector) (18 AWG)*<br>10-inch Cable w/Packard<br>Weatherpack Male Terminal -<br>12020827 (3-Pin Connector)|*** For screw terminal option<br>only|*** For screw terminal option||| |||||||||**T**|M10 × 1.0||||||||10-inch Cable w/Deutsch<br>(18 AWG)*||||| |||||||||**V**|R1/2 BSPT|||||||**MA**|DT04-2P-E005<br>(2-Pin Connector) (18 AWG)<br>3-inch Cable w/Packard 2P||||| |||||||||||||||||**NA**|Tower Connector -<br>12015792 (2-Pin Connector)||||| |||||||||**Y**|G1/4 BSPP||||||||(18 AWG)||||| ||||||||||||||||||2.75-inch Cable w/Packard||||| |||||||||**Z**|R1/4 BSPT|||||||**PA**|2P Shroud Connector -<br>12010973 (2-Pin Connector)<br>(18 AWG)||||| ||||||||||||||||||4-inch Cable w/Packard||||| |||||||||||||||||**RA**|2P Shroud Connector -<br>12010973 (2-Pin Connector)||||| ||||||||||||||||||(16 AWG)||||| ||||||||||||||||||5.5-inch Cable w/ITT||||| |||||||||||||||||**SA**|Cannon 2P Sure-Seal<br>Circular Connector -<br>SS2R-120-1804-000 (2-Pin||||| ||||||||||||||||||Connector) (18 AWG)||||| ||||||||||||||||||8.5-inch Cable w/ITT||||| |||||||||||||||||**TA**|Cannon 3P Sure-Seal<br>Circular Connector -||||| ||||||||||||||||||SS3R-120-8551-001 (3-Pin||||| ||||||||||||||||||Connector) (16 AWG)*||||| ||||||||||||||||||10-inch Cable - Vacuum||||| |||||||||||||||||**UA**|Impregnated w/Deutsch<br>DT06-3S-EP06 (3-Socket||||| ||||||||||||||||||Connector) (16 AWG)*||||| ||||||||||||||||||10-inch Cable - Vacuum||||| |||||||||||||||||**VA**|Impregnated w/Deutsch<br>DT04-3P-E005 (3-Pin||||| ||||||||||||||||||Connector) (16 AWG)*||||| |||||||||||||||||**WA**|4.5-inch Cable w/ 1/4 in<br>Spade Terminals 6,3 mm x||||| ||||||||||||||||||0,8 mm (16 AWG)*||||| |||||||||||||||||**XA**|10-inch Cable w/ Metripack<br>2-Pin Shroud Connector<br>153000287 (18 AWG)||||| |||||||||||||||||**YA**|6-inch Cable w/Amp<br>Super Seal 1.5 - 282104-1<br>(2-Pin Connector) (18 AWG)*||||| ||||||||||||||||||10-inch Cable w/Deutsch||||| |||||||||||||||||**ZA**|DT06-2S-CE06 (2-Socket<br>Connector) (18 AWG)||||| |||||||||||||||||**AB**|Deutsch DT04-2P-E005<br>(2-Pin Connector)||||| |||||||||||||||||**BB**|10-inch Cable w/Metripack<br>150 Delphi 12129615<br>(3-Pin Connector) (18 AWG)*||||| |||||||||||||||||**CB**|6-inch Cable with Amp<br>Super Seal 1.5 - 282080-1<br>(2-Pin Connector) (18 AWG)||||| |||||||||||||||||**DB**|10-inch Cable w/AMP 2,5 mm<br>System Series Connector<br>1-967402-1(18 AWG)*||||| ||||||||||||||||||4.5-inch Cable w/Packard||||| |||||||||||||||||**EB**|Shroud Connector 12015792<br>(2-Pin Connector) (18 AWG)||||| |||||||||||||||||**FB**|10-inch Cable w/Metripack<br>150 Delphi 12052641<br>(2-Pin Connector) (18 AWG)||||| |||||||||||||||||**GB**|8.5-inch Cable w/Deutsch<br>Plug HD 16-3 96S<br>(3-Pin Connector) (16 AWG)||||| - *These connectors are designed for dual circuit (SPDT) by default. They can be used for single-circuit applications (SPNC/SPNO) by making suitable connections. Refer to wiring diagram. - **For electrical termination with SPST option, only SPNO configuration is available. SPNC configuration cannot be provided. 14 sensing.honeywell.com ## ADDITIONAL MATERIALS The following associated literature is available at sensing.honeywell.com: - Product range guide - Product line guide - Technical note: Smart Diagnostic Technology ## m WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. - Product application-specific information - Application Note: Honeywell Pressure Switches - Sensors and switches in front loaders - Sensors and switches in mobile cranes - Sensors and switches in oil rig applications - Industrial product line card ## m WARNING ## MISUSE OF DOCUMENTATION - The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. - Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. ## Warranty/Remedy ## Find out more Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. To learn more about Honeywell’s sensing and switching products, Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer’s sole responsibility to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use. ## call +1-815-235-6847 or 1-800-537-6945, visit sensing.honeywell.com, or e-mail inquiries to info.sc@honeywell.com ## Honeywell Safety and Productivity Solutions 9680 Old Bailes Road Fort Mill, SC 29707 honeywell.com 50094081-5-EN IL50 GLO October 2016 © 2016 Honeywell International Inc. All rights reserved. ® DuPont™, Teflon[®] , Tefzel[®] , and Kapton[®] are trademarks or registered trademarks of E.I. du Pont de Nemours and Company
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →