- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: LDC-80
- Output Current: 2.1A
- LED Driver Mode: Constant Current, Constant Voltage
- Output Power Max: 80W
- Input Voltage Max: 295V
- Input Voltage Min: 180V
- Output Voltage Max: 56VDC
- Power Supply Applications: LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 22.95 € |
| Current stock | 10+ |
| Lead time | 30 days |
**LDC - 80 series** 80W Constant Power MODE Linear LED Driver **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> **==> picture [15 x 119] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>■<br>**----- End of picture text -----**<br> > ℃ ~+85 ℃ **==> picture [116 x 35] intentionally omitted <==** **----- Start of picture text -----**<br> IS 15885(Part 2/Sec13)<br>THOMAS SAMUEL THOMAS SAMUEL 05<br>R-41027766 (8) ck us CG<br>■<br>**----- End of picture text -----**<br> _File Name:LDC-80-SPEC 2018-09-14_ **LDC - 80 series** ## 80W Constant Power MODE Linear LED Driver ## **SPECIFICATION** |**MODEL**<br>**OUTPUT**<br>**SET UP TIME**<br>**Note.4**<br>**VOLTAGE RANGE**<br>**Note.3**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS Note.5**<br>**EMC IMMUNITY**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER TEMPERATURE**<br>500ms/230VAC<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>47 ~ 63Hz<br>PF<br>0.95/230VAC@load<br>50%; PF<br>0.92/277VAC@load<br>75%<br>≧<br>≧<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>0.48A / 230VAC 0.36A/277VAC<br><0.75mA / 277VAC<br>Compliance toEN55015,EN61000-3-2 Class C (@load<br>50%) ; EN61000-3-3;GB/T17743,GB17625.1<br>≧<br>,EAC TP TC 020<br>20 ~ 95% RH non-condensing<br>-40 ~ +80<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>360 30<br>*<br>*21mm (L*W*H)<br>**ENVIRONMENT**<br>**EMC EMISSION**<br>**Note.5**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>**SHORT CIRCUIT**<br>90%(230VAC@Full load)<br>Hiccup mode or constant current limiting ,recovers automatically after fault condition is removed<br>I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**CURRENT TOLERANCE**<br>±5.0%<br>THD< 10%(@load 50%/230VAC; @load 75%/277VAC)<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>**TOTAL HARMONIC DISTORTION**<br>**OPEN CIRCUIT VOLTAGE(max.)**<br>COLD START 55A(twidth=<br>s measured at 50% Ipeak)/230VAC<br>300<br>Per NEMA 410<br>μ<br>;<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>6 units (circuit breaker of type B) / 11 units (circuit breaker of type C) at 230VAC<br>Tcase=-25 ~ +85<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>**MAX. CASE TEMP.**<br>Tcase=+85℃<br>Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge immunity:Line-Earth:2KV,Line-Line:1KV) criteria A,EAC TP TC 020<br>UL8750<br>ENEC EN61347-1, EN61347-2-13,<br>;<br>, CSA C22.2 No. 250.13-12;<br>AS/NZS 61347.1:2016, AS/NZS IEC 61347.2.13:2013<br>EN62384; GB19510.14,GB19510.1<br>,<br>approved<br>, EAC TP TC 004 BIS IS15885<br>℃<br>℃<br>℃<br>℃<br>0.295Kg; 40pcs/12.8Kg/0.81CUFT<br>3.0% max. @rated current<br>180 ~ 295VAC<br>**LDC-80**<br>60V<br>Compliance to IEC62386-101.102.207 for DA-Type only<br>**DALI STANDARDS**<br>**DIMMING**<br>**FUNCTION**<br>By external NTC, please refer to TEMPERATURE COMPENSATION OPERATION section<br>“<br>”<br>Please refer to DIMMING OPERATION”section<br>“<br>**CURRENT RIPPLE**<br>Shut down o/p voltage, with auto-recovery<br>1065K hrs min. Telcordia SR-332 (Bellcore)<br>259Khrs min. MIL-HDBK-217F (25<br>)<br>℃<br>**OVER VOLTAGE**<br>Shut down o/p voltage with auto-recovery or re-power on to recovery<br>61 ~ 80V<br>**TEMP. COMPENSATION**<br>**LOW FREQUENCY**<br>**OUTPUT CURRENT REGION**<br>**RATED POWER Note.2**<br>**CONSTANT CURRENT REGION Note.2** 27 ~ 56V<br>700 ~ 2100mA(700mA default)<br>80W<br>**FULL POWER CURRENT RANGE** 1400 ~ 2100mA<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated currentand 25 _ of ambient temperature.<br>2. Please refer to" OUTPUT CURRENT SETTING ".<br>3. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>6.Thisseriesmeetsthetypical lifeexpectancyof>50000hoursofoperationwhenTcase, particularly (c)point(orTMP,perDLC), isabout75<br>orless.<br>7. Please refer to the warranty statement on MEAN WELL's website at ~~htto://www.meanwell.com~~<br>8. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|**MODEL**<br>**OUTPUT**<br>**SET UP TIME**<br>**Note.4**<br>**VOLTAGE RANGE**<br>**Note.3**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS Note.5**<br>**EMC IMMUNITY**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER TEMPERATURE**<br>500ms/230VAC<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>47 ~ 63Hz<br>PF<br>0.95/230VAC@load<br>50%; PF<br>0.92/277VAC@load<br>75%<br>≧<br>≧<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>0.48A / 230VAC 0.36A/277VAC<br><0.75mA / 277VAC<br>Compliance toEN55015,EN61000-3-2 Class C (@load<br>50%) ; EN61000-3-3;GB/T17743,GB17625.1<br>≧<br>,EAC TP TC 020<br>20 ~ 95% RH non-condensing<br>-40 ~ +80<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>360 30<br>*<br>*21mm (L*W*H)<br>**ENVIRONMENT**<br>**EMC EMISSION**<br>**Note.5**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>**SHORT CIRCUIT**<br>90%(230VAC@Full load)<br>Hiccup mode or constant current limiting ,recovers automatically after fault condition is removed<br>I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**CURRENT TOLERANCE**<br>±5.0%<br>THD< 10%(@load 50%/230VAC; @load 75%/277VAC)<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>**TOTAL HARMONIC DISTORTION**<br>**OPEN CIRCUIT VOLTAGE(max.)**<br>COLD START 55A(twidth=<br>s measured at 50% Ipeak)/230VAC<br>300<br>Per NEMA 410<br>μ<br>;<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>6 units (circuit breaker of type B) / 11 units (circuit breaker of type C) at 230VAC<br>Tcase=-25 ~ +85<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>**MAX. CASE TEMP.**<br>Tcase=+85℃<br>Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge immunity:Line-Earth:2KV,Line-Line:1KV) criteria A,EAC TP TC 020<br>UL8750<br>ENEC EN61347-1, EN61347-2-13,<br>;<br>, CSA C22.2 No. 250.13-12;<br>AS/NZS 61347.1:2016, AS/NZS IEC 61347.2.13:2013<br>EN62384; GB19510.14,GB19510.1<br>,<br>approved<br>, EAC TP TC 004 BIS IS15885<br>℃<br>℃<br>℃<br>℃<br>0.295Kg; 40pcs/12.8Kg/0.81CUFT<br>3.0% max. @rated current<br>180 ~ 295VAC<br>**LDC-80**<br>60V<br>Compliance to IEC62386-101.102.207 for DA-Type only<br>**DALI STANDARDS**<br>**DIMMING**<br>**FUNCTION**<br>By external NTC, please refer to TEMPERATURE COMPENSATION OPERATION section<br>“<br>”<br>Please refer to DIMMING OPERATION”section<br>“<br>**CURRENT RIPPLE**<br>Shut down o/p voltage, with auto-recovery<br>1065K hrs min. Telcordia SR-332 (Bellcore)<br>259Khrs min. MIL-HDBK-217F (25<br>)<br>℃<br>**OVER VOLTAGE**<br>Shut down o/p voltage with auto-recovery or re-power on to recovery<br>61 ~ 80V<br>**TEMP. COMPENSATION**<br>**LOW FREQUENCY**<br>**OUTPUT CURRENT REGION**<br>**RATED POWER Note.2**<br>**CONSTANT CURRENT REGION Note.2** 27 ~ 56V<br>700 ~ 2100mA(700mA default)<br>80W<br>**FULL POWER CURRENT RANGE** 1400 ~ 2100mA<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated currentand 25 _ of ambient temperature.<br>2. Please refer to" OUTPUT CURRENT SETTING ".<br>3. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>6.Thisseriesmeetsthetypical lifeexpectancyof>50000hoursofoperationwhenTcase, particularly (c)point(orTMP,perDLC), isabout75<br>orless.<br>7. Please refer to the warranty statement on MEAN WELL's website at ~~htto://www.meanwell.com~~<br>8. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|**LDC-80**| |---|---|---| ||**OUTPUT CURRENT REGION**|700 ~ 2100mA(700mA default)| ||**RATED POWER Note.2**|80W| ||**CONSTANT CURRENT REGION Note.2**|27 ~ 56V| ||**FULL POWER CURRENT RANGE**|1400 ~ 2100mA| ||**OPEN CIRCUIT VOLTAGE(max.)**|60V| ||**CURRENT RIPPLE**<br>**LOW FREQUENCY**|3.0% max. @rated current| ||**CURRENT TOLERANCE**|±5.0%| ||**SET UP TIME**<br>**Note.4**|500ms/230VAC| ||**VOLTAGE RANGE**<br>**Note.3**|(Please refer to "STATIC CHARACTERISTIC" section)<br>180 ~ 295VAC| ||**FREQUENCY RANGE**|47 ~ 63Hz| ||**POWER FACTOR (Typ.)**|PF<br>0.95/230VAC@load<br>50%; PF<br>0.92/277VAC@load<br>75%<br>≧<br>≧<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)| ||**TOTAL HARMONIC DISTORTION**|THD< 10%(@load 50%/230VAC; @load 75%/277VAC)<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)| ||**EFFICIENCY (Typ.)**|90%(230VAC@Full load)| ||**AC CURRENT (Typ.)**|0.48A / 230VAC 0.36A/277VAC| ||**INRUSH CURRENT(Typ.)**|COLD START 55A(twidth=<br>s measured at 50% Ipeak)/230VAC<br>300<br>Per NEMA 410<br>μ<br>;| ||**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**|6 units (circuit breaker of type B) / 11 units (circuit breaker of type C) at 230VAC| ||**LEAKAGE CURRENT**|<0.75mA / 277VAC| ||**SHORT CIRCUIT**|Hiccup mode or constant current limiting ,recovers automatically after fault condition is removed| ||**OVER VOLTAGE**|Shut down o/p voltage with auto-recovery or re-power on to recovery<br>61 ~ 80V| ||**OVER TEMPERATURE**|Shut down o/p voltage, with auto-recovery| ||**DIMMING**|Please refer to DIMMING OPERATION”section<br>“| ||**TEMP. COMPENSATION**|By external NTC, please refer to TEMPERATURE COMPENSATION OPERATION section<br>“<br>”| ||**WORKING TEMP.**|Tcase=-25 ~ +85<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃| ||**MAX. CASE TEMP.**|Tcase=+85℃| ||**WORKING HUMIDITY**|20 ~ 95% RH non-condensing| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +80<br>, 10 ~ 95% RH<br>℃| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes| ||**SAFETY STANDARDS Note.5**|UL8750<br>ENEC EN61347-1, EN61347-2-13,<br>;<br>, CSA C22.2 No. 250.13-12;<br>AS/NZS 61347.1:2016, AS/NZS IEC 61347.2.13:2013<br>EN62384; GB19510.14,GB19510.1<br>,<br>approved<br>, EAC TP TC 004 BIS IS15885| ||**DALI STANDARDS**|Compliance to IEC62386-101.102.207 for DA-Type only| ||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃| ||**EMC EMISSION**<br>**Note.5**|Compliance toEN55015,EN61000-3-2 Class C (@load<br>50%) ; EN61000-3-3;GB/T17743,GB17625.1<br>≧<br>,EAC TP TC 020| ||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge immunity:Line-Earth:2KV,Line-Line:1KV) criteria A,EAC TP TC 020| ||**MTBF**|1065K hrs min. Telcordia SR-332 (Bellcore)<br>259Khrs min. MIL-HDBK-217F (25<br>)<br>℃| ||**DIMENSION**|360 30<br>*<br>*21mm (L*W*H)| ||**PACKING**|0.295Kg; 40pcs/12.8Kg/0.81CUFT| ||℃<br>℃<br>℃<br>℃<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated currentand 25 _ of ambient temperature.<br>2. Please refer to" OUTPUT CURRENT SETTING ".<br>3. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>6.Thisseriesmeetsthetypical lifeexpectancyof>50000hoursofoperationwhenTcase, particularly (c)point(orTMP,perDLC), isabout75<br>orless.<br>7. Please refer to the warranty statement on MEAN WELL's website at ~~htto://www.meanwell.com~~<br>8. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|| _File Name:LDC-80-SPEC 2018-09-14_ **LDC - 80 series** ## 80W Constant Power MODE Linear LED Driver ## **BLOCK DIAGRAM** **==> picture [433 x 148] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc : 50~400KHz<br>PWM fosc : 30~200KHz<br>EMI FILTER POWER RECTIFIERS +V<br>I/P & SWITCHING & -V<br>RECTIFIERS FILTER<br>CP. DIM+<br>DIM-<br>(B Type)<br>O.T.P. O.L.P. DETECTION<br>PWM & PFC CIRCUIT<br>CONTROL<br>O.V.P.<br>CASE GROUND<br>**----- End of picture text -----**<br> ## **OUTPUT CURRENT SETTING** ## ◎I-V Operating Area. Output rated current level can be adjusted by a additive resistance. **==> picture [452 x 338] intentionally omitted <==** **----- Start of picture text -----**<br> LDC-80<br>60V<br>56V<br>50V<br>40V<br>30V LDC-80<br>27V<br>20V<br>10V<br>0V<br>500mA 700mA 900mA 1100mA 1300mA 1500mA 1700mA 1900mA 2100mA 2300mA<br>CURRENT<br>◎ Rated current setting table<br>Vo+<br>Vo+<br>18.7K 23.2K 28K 34K 46K 68K 103K 188K NC Vo-Vo-<br>NTC<br>2.1A 1.9A 1.75A 1.6A 1.4A 1.2A 1.05A 0.9A 0.7A TB2 IADJNTC<br>IADJ<br>Note: output power≤80W DIM+DIM- resistor<br>VOLTAGE<br>**----- End of picture text -----**<br> _File Name:LDC-80-SPEC 2018-09-14_ **LDC - 80 series** 80W Constant Power MODE Linear LED Driver ## **DIMMING OPERATION** **==> picture [371 x 77] intentionally omitted <==** **----- Start of picture text -----**<br> Vo+<br>AC/L Vo+<br>Vo-<br>AC/N Vo-<br>FG NTC<br>NTC<br>IADJ<br>DA-;N IADJ<br>DA+;Ls DIM+<br>DIM-<br>**----- End of picture text -----**<br> ## ※ **3 in 1 dimming function(for B-Type)** - �Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: 0 ~ 10VDC, or 10V PWM signal or resistance. - �Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers. �Dimming source current from power supply: 100μA (typ.) **==> picture [450 x 490] intentionally omitted <==** **----- Start of picture text -----**<br> ◎ Applying additive 0 ~ 10VDC 100%<br>90%<br>80%<br>+<br>Vo+ + 70%<br>60%<br>-<br>Vo- - 50%<br>DIM+ 40%<br>+<br>Additive Voltage 30%<br>- 20%<br>DIM-<br>10%<br>“DO NOT connect "DIM- to Vo-" 0%<br>0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V<br>Dimming input: Additive voltage<br>◎ Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz): 100%<br>90%<br>80%<br>+<br>Vo+ + 70%<br>60%<br>-<br>Vo- - 50%<br>DIM+ 40%<br>Additive PWM signal 30%<br>20%<br>DIM-<br>10%<br>“DO NOT connect "DIM- to Vo-" 0%<br>0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>Duty cycle of additive 10V PWM signal dimming input<br>100%<br>◎ Applying additive resistance: 90%<br>80%<br>+<br>Vo+ + 70%<br>- 60%<br>Vo- - 50%<br>DIM+<br>40%<br>Additive Resistance 30%<br>20%<br>DIM-<br>10%<br>“DO NOT connect "DIM- to Vo-" 0%<br>Short 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N<br>(N=driver quantity for synchronized dimming operation)<br>Dimming input: Additive resistance<br>Note : 1. Min. dimming level is about 8% and the output current is not defined when 0%< Iout<8%.<br>2. The output current could drop down to 0% when dimming input is about 0Vdc or 10V PWM signal with 0% duty cycle.<br>3. To ensure the dimming performance at low dimming level,output current must be over 80mA.<br>Output current (%)<br>Output current (%)<br>Output current (%)<br>**----- End of picture text -----**<br> _File Name:LDC-80-SPEC 2018-09-14_ **LDC - 80 series** 80W Constant Power MODE Linear LED Driver ※ **DALI interface** **==> picture [455 x 77] intentionally omitted <==** **----- Start of picture text -----**<br> Vo+<br>AC/L Vo+<br>Vo-<br>AC/N Vo-<br>FG NTC<br>AC/N NTC<br>IADJ<br>Push Button DA-;N IADJ<br>AC/L DA+;Ls DIM+<br>DIM-<br>**----- End of picture text -----**<br> ## ◎ **PUSH dimming(primary side)** |**Action**|**Action duration**|**Function**| |---|---|---| |Short push|0.1~1 sec.|Turn ON-OFF the driver| |Long push|1.5~10 sec.|Every Long Push changes the dimming direction, dimming up or down| |Reset|>11 sec.|Set up the dimming level to 100%| - �The factory default dimming level is at 100%. - �If the push action lasts less than 0.05 sec., it will not lead to a change for the status of the driver. �Up to 10 drivers can perform the PUSH dimming at the same time when utilizing one common push button. - �The maximum length of the cable from the push button to the last driver is 20 meters. - �The additive push button can be connected only between the LS terminal, as displayed in the diagram, and AC/L (in brown or black); it will lead to short circuit if it is connected to AC/N. ## ◎ **DALI interface(primary side)** - �Apply DALI signal between DA+ and DA- - �DALI protocol comprises 16 groups and 64 addresses. - �First step is fixed at 8% of rated output power. **NOTE: DALI, Push dimming can not be used in the same time!(The factory setting defaults to DA)** _File Name:LDC-80-SPEC 2018-09-14_ **LDC - 80 series** 80W Constant Power MODE Linear LED Driver ## **TEMPERATURE COMPENSATION OPERATION** LDC-80 have the built-in temperature compensation function ; by connecting a temperature sensor (NTC resistor) between the _+NTC / -NTC_ terminal of LDC-80 and the detecting point on the lighting system or the surrounding environment, output current of LDC-80 could be correspondingly changed, based on the sensed temperature, to ensure the long life of LED. **==> picture [334 x 77] intentionally omitted <==** **----- Start of picture text -----**<br> Vo+<br>Vo+<br>Vo-<br>Vo-<br>NTC<br>NTC<br>IADJ<br>NTC resistor<br>IADJ<br>DIM+<br>DIM-<br>**----- End of picture text -----**<br> ◎ LDC-80 can still be operated normally when the NTC resistor is not connected and the value of output current will be the current level selected through the IADJ. pin ◎ NTC reference: NTC resistance Output Current <17.5K Output current reduce as the resistance decreases >17.5K Normal output current Notes: 1. MEAN WELL does not offer the NTC resistor and all the data above are measured by using resistor. 2. If new brand of NTC resistor is applied,please check the temperature curve first. ◎ Dimming function of the driver will be invalid when the "temperature compensation" function is in use. _File Name:LDC-80-SPEC 2018-09-14_ **LDC - 80 series** 80W Constant Power MODE Linear LED Driver ## **OUTPUT LOAD vs TEMPERATURE** **==> picture [487 x 601] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>80 80<br>60 60<br>40 40<br>20 20<br>-25 -10 0 15 30 50 60 65 (HORIZONTAL) -25 -10 0 20 45 55 65 75 85 (HORIZONTAL)<br>AMBIENT TEMPERATURE,Ta ( ℃ ) Tcase ( ℃ )<br>STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC<br>※ Tcase at 75℃<br>1<br>100<br>0.98<br>90<br>0.96<br>80<br>277V<br>70 0.94<br>230V<br>60 0.92<br>50<br>0.9<br>40<br>0.88<br>50% 60% 70% 80% 90% 100%<br>180 190 200 210 220 230 240 295<br>(80W)<br>INPUT VOLTAGE (V) 60Hz LOAD<br>(230Vac Input)<br>TOTAL HARMONIC DISTORTION (THD) EFFICIENCY vs LOAD<br>LDC-80 series possess superior working efficiency up to 90%.<br>※ 1400mA Model, Tcase at 75℃ ※ 1400mA Model, Tcase at 75℃<br>7% 96<br>94<br>6% 92<br>90<br>6%<br>88<br>5% 277VAC 86<br>230VAC 84 277V<br>5% 82<br>230V<br>80<br>4% 78<br>76<br>4%<br>74<br>3% 72<br>50% 60% 70% 80% 90% 100% 70<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>LOAD LOAD<br>LOAD (%) LOAD (%)<br>LOAD (%) PF<br>THD<br>EFFICIENCY(%)<br>**----- End of picture text -----**<br> _File Name:LDC-80-SPEC 2018-09-14_ **LDC - 80 series** 80W Constant Power MODE Linear LED Driver ## **LIFE TIME** **==> picture [388 x 246] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100<br>80<br>60<br>40<br>20<br>0<br>20 30 40 50 60 70 80 ��<br>Tcase ( ) ℃<br>LIFETIME(Kh)<br>**----- End of picture text -----**<br> _File Name:LDC-80-SPEC 2018-09-14_ **LDC - 80 series** ## 80W Constant Power MODE Linear LED Driver **- series** MEAN WELL ~~eee~~ eee eee ee ee ee ee ee ee eee ~~eee eee~~ **==> picture [470 x 407] intentionally omitted <==** **----- Start of picture text -----**<br> MECHANICAL SPECIFICATION<br>CASE NO.:264A Unit:mm<br>360<br>353 3.5<br>135<br>tc 6<br>[& TB1 Gz|Ad EpHEIL, TB2 || 4<br>ψ4.5 Wor Hz| ~*S ψ4.5<br>tc : Max. Case Temperature<br>--- —— 5°0—NnmwjqmxoS—="1000000[—T"— T0€TY">/?YV9#<br>Terminal Pin No. Assignment (TB1) : Terminal Pin No. Assignment (TB2) :<br>Pin No. Assignment Pin No. Assignment<br>a 1 ACL 1 Vo+ PUSH DIMMING<br>potastve pushto-ma<br>2 ACN 2 Vo+<br>Retractive push-to-make<br>po 3 NC 3 Vo- v<br>4 FG 4 Vo-<br>5 NC(for DA-type only ) 5 NTC<br>po sci g—P_on t,<br>so 6 (for DA-type only) 6 NTC<br>[pats 7 (for DA-type only) 7 IADJ<br>8 IADJ<br>9 DIM+(for B-type only)<br>10 DIM-(for B-type only)<br>15 15<br>30<br>21<br>9.5<br>**----- End of picture text -----**<br> 8-9mm 8-9mm ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:LDC-80-SPEC 2018-09-14_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →