Image not available
Illustrative purposes only
LCM-25DA2
LED Driver, LED Lighting, 25.2 W, 24 VDC, 1.05 A, Constant Current, 180 V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: LCM-25DA
- Output Current: 1.05A
- LED Driver Mode: Constant Current
- Output Power Max: 25.2W
- Input Voltage Max: 277V
- Input Voltage Min: 180V
- Output Voltage Max: 24VDC
- Power Supply Applications: LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 24.47 € |
| Current stock | 10+ |
| Lead time | 30 days |
**LCM - 25DA series** 25W Multiple-Stage Constant Current Mode LED Driver **IS 15885(Part 2/Sec13)** THOMAS SAMUEL THOMAS SAMUEL ** R-41027766** 2 Whs& ICBCE (except for DA2-Type)(except for DA2-Type) > 2 ** ** > (for DA2-Type only) ~~ap~~ (for DA-Type only) ~~aid gO~~ L)//V/ ~~E~~ Oa®M@ ## ■ **** - ‧ - - ‧ - ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - - - ‧ ## ■ **** ~ ℃℃ ## ■ **** ## **** ~~{~~ _File Name:LCM-25DA-SPEC 2020-11-27_ ## 25W Multiple-Stage Constant Current Mode LED Driver ## **LCM - 25DA series** ## **SPECIFICATION** |**MODEL**<br>**LCM-25**<br>**DC VOLTAGE RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**SETUP TIME**<br>**VOLTAGE RANGENote.2**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)Note.4**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**DALI STANDARDS**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>18.9W<br>59V<br>41V<br>500ms / 230VAC<br>180 ~ 277VAC 254 ~ 392VDC(254~375VDC for DA2-Type)<br>47 ~ 63Hz<br>86%<br>20 ~ 90% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>℃<br><br><br><br><br><br><br>℃℃<br><br><br>※ : , https://www.meanwell.com/serviceDisclaimer.aspx<br>**OPEN CIRCUIT VOLTAGE (max.)**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**FUNCTION**<br>**EMC**<br>**PROTECTION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>IEC62386-101, 102, 207,251<br>I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH<br>**CURRENT LEVEL**<br>350mA<br>600mA<br>500mA<br>700mA(default)<br>900mA<br>1050mA<br>**CURRENT TOLERANCE**<br>**SHORT CIRCUIT**<br>**OVER TEMPERATURE**<br>**SYNCHRONIZATION**<br>Constant current limiting, recovers automatically after fault condition is removed<br>Please refer to "SYNCHRONIZATION OPERATION” section<br>**DIMMING**<br>Please refer to "DIMMING OPERATION" section<br>**TOTAL HARMONIC DISTORTION**<br><0.5mA / 240VAC<br>PF≧0.94/230VAC, PF≧0.91/277VAC@full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>COLD START 20A(twidth=260μs measured at 50% Ipeak) at 230VAC<br>;Per NEMA 410<br>±5%<br>±0.03%/℃(0 ~ 50℃)<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>26 units (circuit breaker of type B) / 44 units (circuit breaker of type C) at 230VAC<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>**WORKING TEMP.**<br>**MAX. CASE TEMP.**<br>Tcase=+85℃<br>Tcase=-30 ~ +85℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>**CURRENT RIPPLE**<br>5.0% max. @rated current<br>Current level selectable via DIP switch, please refer to”DIP SWITCH TABLE” section<br>THD< 20%(@load≧50%/230VAC; @load≧75%/277VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>Compliance to EN55015, EN61000-3-2 Class C(@load≧50%) ; EN61000-3-3; GB17625.1,GB17743, EAC TP TC 020<br>**EMC IMMUNITY**<br><0.5W<br>**STANDBY POWER**<br>**CONSUMPTIONNote.5**<br>**EMC EMISSION Note.6**<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level(surge immunity Line-Line 2KV), EAC TP TC 020<br>6 ~ 50V<br>6 ~ 54V<br>6 ~ 42V<br>6 ~ 36V<br>6 ~ 24V<br>6 ~ 28V<br>25.2W<br>0.17A/230VAC 0.15A/277VAC<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>UL8750(except for DA2-Type), CSA C22.2 NO.250.0-08, ENEC EN61347-1, EN61347-2-13, EN62384 independent,GB19510.14,<br>GB19510.1,BIS IS15885(except for DA2-Type), EAC TP TC 004 approved; According to EN61347-2-13<br>appendix J suitable for emergency installations<br>I/P-O/P:3.75KVAC ; I/P-DA:1.5KVAC ; O/P-DA:1.5KVAC<br>213.3K hrs min. MIL-HDBK-217F (25℃)<br>105*68*23mm (L*W*H)<br>0.17Kg ; 72pcs/13.2Kg/1.04CUFT<br> **Note.3**<br> **Note.8**|**MODEL**<br>**LCM-25**<br>**DC VOLTAGE RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**SETUP TIME**<br>**VOLTAGE RANGENote.2**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)Note.4**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**DALI STANDARDS**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>18.9W<br>59V<br>41V<br>500ms / 230VAC<br>180 ~ 277VAC 254 ~ 392VDC(254~375VDC for DA2-Type)<br>47 ~ 63Hz<br>86%<br>20 ~ 90% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>℃<br><br><br><br><br><br><br>℃℃<br><br><br>※ : , https://www.meanwell.com/serviceDisclaimer.aspx<br>**OPEN CIRCUIT VOLTAGE (max.)**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**FUNCTION**<br>**EMC**<br>**PROTECTION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>IEC62386-101, 102, 207,251<br>I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH<br>**CURRENT LEVEL**<br>350mA<br>600mA<br>500mA<br>700mA(default)<br>900mA<br>1050mA<br>**CURRENT TOLERANCE**<br>**SHORT CIRCUIT**<br>**OVER TEMPERATURE**<br>**SYNCHRONIZATION**<br>Constant current limiting, recovers automatically after fault condition is removed<br>Please refer to "SYNCHRONIZATION OPERATION” section<br>**DIMMING**<br>Please refer to "DIMMING OPERATION" section<br>**TOTAL HARMONIC DISTORTION**<br><0.5mA / 240VAC<br>PF≧0.94/230VAC, PF≧0.91/277VAC@full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>COLD START 20A(twidth=260μs measured at 50% Ipeak) at 230VAC<br>;Per NEMA 410<br>±5%<br>±0.03%/℃(0 ~ 50℃)<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>26 units (circuit breaker of type B) / 44 units (circuit breaker of type C) at 230VAC<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>**WORKING TEMP.**<br>**MAX. CASE TEMP.**<br>Tcase=+85℃<br>Tcase=-30 ~ +85℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>**CURRENT RIPPLE**<br>5.0% max. @rated current<br>Current level selectable via DIP switch, please refer to”DIP SWITCH TABLE” section<br>THD< 20%(@load≧50%/230VAC; @load≧75%/277VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>Compliance to EN55015, EN61000-3-2 Class C(@load≧50%) ; EN61000-3-3; GB17625.1,GB17743, EAC TP TC 020<br>**EMC IMMUNITY**<br><0.5W<br>**STANDBY POWER**<br>**CONSUMPTIONNote.5**<br>**EMC EMISSION Note.6**<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level(surge immunity Line-Line 2KV), EAC TP TC 020<br>6 ~ 50V<br>6 ~ 54V<br>6 ~ 42V<br>6 ~ 36V<br>6 ~ 24V<br>6 ~ 28V<br>25.2W<br>0.17A/230VAC 0.15A/277VAC<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>UL8750(except for DA2-Type), CSA C22.2 NO.250.0-08, ENEC EN61347-1, EN61347-2-13, EN62384 independent,GB19510.14,<br>GB19510.1,BIS IS15885(except for DA2-Type), EAC TP TC 004 approved; According to EN61347-2-13<br>appendix J suitable for emergency installations<br>I/P-O/P:3.75KVAC ; I/P-DA:1.5KVAC ; O/P-DA:1.5KVAC<br>213.3K hrs min. MIL-HDBK-217F (25℃)<br>105*68*23mm (L*W*H)<br>0.17Kg ; 72pcs/13.2Kg/1.04CUFT<br> **Note.3**<br> **Note.8**|**LCM-25**|**LCM-25**|**LCM-25**|**LCM-25**|**LCM-25**|**LCM-25**| |---|---|---|---|---|---|---|---| ||**CURRENT LEVEL**|350mA<br>600mA<br>500mA<br>700mA(default)<br>900mA<br>1050mA<br>Current level selectable via DIP switch, please refer to”DIP SWITCH TABLE” section|||||| ||**RATED POWER**|18.9W|25.2W||||| ||**DC VOLTAGE RANGE**|6 ~ 54V|6 ~ 50V|6 ~ 42V|6 ~ 36V|6 ~ 28V|6 ~ 24V| ||**OPEN CIRCUIT VOLTAGE (max.)**|59V|||41V||| ||**CURRENT RIPPLE**|5.0% max. @rated current|||||| ||**CURRENT TOLERANCE**|±5%|||||| ||**SETUP TIME**<br> **Note.3**<br> **Note.8**|500ms / 230VAC|||||| ||**VOLTAGE RANGENote.2**|180 ~ 277VAC 254 ~ 392VDC(254~375VDC for DA2-Type)<br>(Please refer to "STATIC CHARACTERISTIC" section)|||||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||||| ||**POWER FACTOR (Typ.)**|PF≧0.94/230VAC, PF≧0.91/277VAC@full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)|||||| ||**TOTAL HARMONIC DISTORTION**|THD< 20%(@load≧50%/230VAC; @load≧75%/277VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)|||||| ||**EFFICIENCY (Typ.)Note.4**|86%|||||| ||**AC CURRENT (Typ.)**|0.17A/230VAC 0.15A/277VAC|||||| ||**INRUSH CURRENT (Typ.)**|COLD START 20A(twidth=260μs measured at 50% Ipeak) at 230VAC<br>;Per NEMA 410|||||| ||**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**|26 units (circuit breaker of type B) / 44 units (circuit breaker of type C) at 230VAC|||||| ||**LEAKAGE CURRENT**|<0.5mA / 240VAC|||||| ||**STANDBY POWER**<br>**CONSUMPTIONNote.5**|<0.5W|||||| ||**SHORT CIRCUIT**|Constant current limiting, recovers automatically after fault condition is removed|||||| ||**OVER TEMPERATURE**|Shut down o/p voltage, recovers automatically after temperature goes down|||||| ||**DIMMING**|Please refer to "DIMMING OPERATION" section|||||| ||**SYNCHRONIZATION**|Please refer to "SYNCHRONIZATION OPERATION” section|||||| ||**WORKING TEMP.**|Tcase=-30 ~ +85℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)|||||| ||**MAX. CASE TEMP.**|Tcase=+85℃|||||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +80℃, 10 ~ 95% RH|||||| ||**TEMP. COEFFICIENT**|±0.03%/℃(0 ~ 50℃)|||||| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes|||||| ||**SAFETY STANDARDS**|UL8750(except for DA2-Type), CSA C22.2 NO.250.0-08, ENEC EN61347-1, EN61347-2-13, EN62384 independent,GB19510.14,<br>GB19510.1,BIS IS15885(except for DA2-Type), EAC TP TC 004 approved; According to EN61347-2-13<br>appendix J suitable for emergency installations|||||| ||**DALI STANDARDS**|IEC62386-101, 102, 207,251|||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC ; I/P-DA:1.5KVAC ; O/P-DA:1.5KVAC|||||| ||**ISOLATION RESISTANCE**|I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH|||||| ||**EMC EMISSION Note.6**|Compliance to EN55015, EN61000-3-2 Class C(@load≧50%) ; EN61000-3-3; GB17625.1,GB17743, EAC TP TC 020|||||| ||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level(surge immunity Line-Line 2KV), EAC TP TC 020|||||| ||**MTBF**|213.3K hrs min. MIL-HDBK-217F (25℃)|||||| ||**DIMENSION**|105*68*23mm (L*W*H)|||||| ||**PACKING**<br>℃<br><br><br><br><br><br><br>℃℃<br><br><br>※ : , https://www.meanwell.com/serviceDisclaimer.aspx<br>0.17Kg ; 72pcs/13.2Kg/1.04CUFT||||||| _File Name:LCM-25DA-SPEC 2020-11-27_ **LCM - 25DA series** ## 25W Multiple-Stage Constant Current Mode LED Driver ## **BLOCK DIAGRAM** **==> picture [474 x 178] intentionally omitted <==** **----- Start of picture text -----**<br> BLOCK DIAGRAM PFC fosc : 45KHz<br>PWM fosc : 70KHz<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P & CIRCUIT SWITCHING & -V<br>RECTIFIERS FILTER<br>CURRENT<br>LIMITING<br>O.L.P.<br>PWM DETECTION<br>PFC CONTROL CIRCUIT<br>CONTROL<br>O.T.P.<br>MCU<br>DA+/DA-<br>PUSH<br>**----- End of picture text -----**<br> ## **DIP SWITCH TABLE** LCM-25DA/DA2 is a multiple-stage constant current driver, selection of output current through DIP switch is exhibited below. **==> picture [452 x 173] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||||| |---|---|---|---|---|---|---|---| |DIP S.W.| |Io|1|2|3|4|5|6| |350mA|----|----|----|----|----|----| |500mA|ON|----|----|----|----|----| |600mA|ON|ON|----|----|----|----|ON| |700mA(factory default)|ON|ON|ON|----|----|ON| |1|2|3|4|5|6| |900mA|ON|ON|ON|ON|----|ON| |1050mA|ON|ON|ON|ON|ON|ON| |Note: For more current setting,please contact MW’s sales.| |ON| |1|2|3|4|5|6| **----- End of picture text -----**<br> _File Name:LCM-25DA-SPEC 2020-11-27_ **LCM - 25DA series** 25W Multiple-Stage Constant Current Mode LED Driver ## **DIMMING OPERATION** **==> picture [434 x 85] intentionally omitted <==** **----- Start of picture text -----**<br> LCM-25DA DA- LCM-25DA2<br>DA+ DA-<br>PUSH Push Button DA+ Push Button<br>AC/N AC/N AC/N AC/N<br>AC/L AC/L AC/L AC/L<br>**----- End of picture text -----**<br> ## ※ **PUSH dimming(primary side)** |**Action**|**Action duration**|**Function**| |---|---|---| |Short push|0.1~1 sec.|Turn ON-OFF the driver| |Long push|1.5~10 sec.|Every Long Push changes the dimming direction, dimming up or down| |Reset|>11 sec.|Set up the dimming level to 100%| - ‧The factory default dimming level is at 100%. - ‧If the push action lasts less than 0.05 sec., it will not lead to a change for the status of the driver. - ‧Up to 10 drivers can perform the PUSH dimming at the same time when utilizing one common push button. - ‧The maximum length of the cable from the push button to the last driver is 20 meters. - ‧The additive push button can be connected only between the PUSH terminal, as displayed in the diagram, and AC/L (in brown or black); it will lead to short circuit if it is connected to AC/N. ## ※ **DALI interface(primary side; for DA/DA2-Type)** - ‧Apply DALI signal between DA+ and DA- - ‧DALI protocol comprises 16 groups and 64 addresses. - ‧First step is fixed at 6% of output. _File Name:LCM-25DA-SPEC 2020-11-27_ > 25W Multiple-Stage Constant Current Mode LED Driver **LCM - 25DA series** ## **SYNCHRONIZATION OPERATION** **==> picture [484 x 324] intentionally omitted <==** **----- Start of picture text -----**<br> ‧Synchronization up to 10 drivers (1 master + 9 slaves)<br>‧Dimming operating range : 10%~100%<br>‧Sync cable length : < 5m<br>‧Sync cable type : Flat cable<br>‧Sync cable cross section area : 22 – 24 AWG (0.2~0.3mm )2<br>LCM-25DA/DA2 LCM-25DA/DA2 LCM-25DA/DA2 LCM-25DA/DA2 LCM-25DA/DA2<br>(Slave 1) (Master) (Slave 4) (Slave 5) (Slave 9)<br>SYN. ... SYN. SYN. SYN. ..... SYN.<br>CN101<br>CN100<br>.....<br>DALI 5m 5m<br>Controller<br>LCM-25DA/DA2 LCM-25DA/DA2 LCM-25DA/DA2 LCM-25DA/DA2 LCM-25DA/DA2<br>(Slave 1) (Master) (Slave 4) (Slave 5) (Slave 9)<br>SYN. ... SYN. SYN. SYN. ..... SYN.<br>CN101<br>CN100<br>.....<br>5m 5m<br>PUSH dim PUSH dim<br>(Only for DA-Type) (Only for DA2-Type)<br>+ + + + +<br>+ + + + +<br>AC/L AC/N PUSH DA+ DA-<br>+ + + + +<br>+ + + + +<br>AC/L AC/N PUSH DA+ DA-<br>- - - - -<br>- - - - -<br>- - - - -<br>- - - - -<br>**----- End of picture text -----**<br> - ‧CN100, CN101 : used to synchronously control the LCM units in parallel. NOTE: 1. Please make sure all units are set to 100% dimming setting (factory default) before synchronizing. 2. Min. Dimming operating range depends on dimmer setting. _File Name:LCM-25DA-SPEC 2020-11-27_ **LCM - 25DA series** 25W Multiple-Stage Constant Current Mode LED Driver ## **OUTPUT LOAD vs TEMPERATURE** **==> picture [486 x 147] intentionally omitted <==** **----- Start of picture text -----**<br> Others<br>100 100<br>80 80<br>60 1050mA 60<br>40 40<br>900mA<br>20 20<br>-30 -15 0 15 30 40 45 50 55 60 70 (HORIZONTAL) -30 -25 0 20 45 55 65 75 85 (HORIZONTAL)<br>AMBIENT TEMPERATURE,Ta ( ℃ ) Tcase ( ℃ )<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> ## **STATIC CHARACTERISTIC** **==> picture [197 x 159] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>90<br>80<br>70<br>60<br>50<br>40<br>180 190 200 210 220 230 240 250 260 270 277<br>INPUT VOLTAGE (V) 60Hz<br>De-rating is needed under low input voltage.<br>LOAD (%)<br>**----- End of picture text -----**<br> _File Name:LCM-25DA-SPEC 2020-11-27_ **LCM - 25DA series** 25W Multiple-Stage Constant Current Mode LED Driver **==> picture [492 x 646] intentionally omitted <==** **----- Start of picture text -----**<br> 7 TOTAL HARMONIC DISTORTION (THD)<br>※ Tcase at 75℃<br>25 45<br>40<br>20 35<br>: 350mA 30 ~_— 350mA<br>15 : 500mA 25 ad 500mA<br>: 600mA ->_ 600mA<br>20<br>10 : 700mA 700mA<br>. 900mA 15 a 900mA<br>5 : 1050mA 10 oe 1050mA<br>5<br>0 : 0<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>LOAD LOAD<br>(230Vac Input) (277Vac Input)<br>POWER FACTOR (PF) CHARACTERISTIC<br>※ Tcase at 75℃<br>1<br>1<br>0.95 0.95<br>0.9<br>0.9<br>0.85<br>0.85 i 350mA 0.8 —~— 350mA<br>0.8 500mA 0.75 500mA<br>= 600mA 0.7 - 600mA<br>0.75<br>= 700mA 0.65 se 700mA<br>0.7 - 900mA 0.6 a= 900mA<br>0.65 - 1050mA 0.55 — 1050mA<br>0.5<br>0.6 0.45<br>0.4<br>0.55<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>(25W) (25W)<br>LOAD LOAD<br>(230Vac Input) (277Vac Input)<br>= EFFICIENCY vs LOAD<br>LCM-25DA series possess superior working efficiency that up to 86% can be reached in field applications.<br>※ Tcase at 75℃<br>90 90<br>85 85<br>80 80<br>75 e e - 350mA 75 350mA<br>70 500mA 70 500mA<br>600mA 600mA<br>65 BZ = 65<br>700mA 700mA<br>60 900mA 60 900mA<br>J : ~_<br>55 : 1050mA 55 1050mA<br>50 / : 50 :<br>45 45<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>LOAD LOAD<br>(230Vac Input) (277Vac Input)<br>THD THD<br>PF PF<br>EFFICIENCY (%) EFFICIENCY (%)<br>**----- End of picture text -----**<br> _File Name:LCM-25DA-SPEC 2020-11-27_ **LCM - 25DA series** 25W Multiple-Stage Constant Current Mode LED Driver **==> picture [497 x 469] intentionally omitted <==** **----- Start of picture text -----**<br> MECHANICAL SPECIFICATION Case No.LCM-25 Unit:mm<br>105<br>6 93<br>6 1<br>2<br>6 3 TB1<br>4<br>5 LCM-25DA<br>21 TB2<br>1 2 1 2<br>CN100,CN101<br>ON<br>1 2 3 4 5 6<br>40.8 45.5<br>7.8 7.8 21<br>2-ψ4 3<br>TB1<br>4 4<br>LCM-25DA2<br>21 TB2<br>1 2 1 2<br>CN100,CN101<br>※Terminal Pin No. Assignment(TB1)(LCM-25DA) ON1 2 3 4 5 6<br>Pin No. Assignment Pin No. Assignment<br>1 AC/L 4 DA+<br>2 AC/N 5 DA-<br>3 PUSH<br>※Terminal Pin No. Assignment(TB1)(LCM-25DA2) 35<br>Pin No. Assignment Pin No. Assignment tc<br>1 AC/L 4 DA+<br>2 AC/N<br>3 DA-<br>※Terminal Pin No. Assignment(TB2)<br>Pin No. Assignment<br>1 +V<br>2 -V Bottom View<br>※SYN. Connector(CN100/CN101):JST B2B-PH-KL or equivalent ‧tc : Max. Case Temperature<br>Pin No. Assignment Mating Housing Terminal<br>1 - JST PHR-2 JST SPH-002T-P0.5S<br>2 + or equivalent or equivalent<br>Note:Please use wires with a cross section of 0.5~2.5mm2(14~20AWG) for TB1 and wires with a cross section of 0.5~1.5 mm2(16~20AWG) for TB2.<br>Please use wires with a cross section of 0.126~0.205mm2(24~26AWG) for CN100/CN101<br>4.2<br>ψ<br>2-<br>68 62<br>23<br>20<br>**----- End of picture text -----**<br> ## **INSTALLATION MANUAL** Please refer to : http://www.meanwell.com/manual.html _File Name:LCM-25DA-SPEC 2020-11-27_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →