LCE80PS12
AC/DC Open Frame Power Supply (PSU), ITE, 1 Output, 80 W, 85V AC to 305V AC, Fixed
- Manufacturer: XP POWER
- Product type: AC / DC Open Frame Power Supplies
- SVHC: No SVHC (15-Jan-2018)
- Product Range: LCE80 Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 85V AC to 305V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 6.67A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 80W
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 30.06 € |
| Current stock | 10+ |
| Lead time | 30 days |
## LCE80 Series ## 80W **CONVECTION COOLED** ## AC-DC POWER SUPPLIES With an excellent power density, constant voltage and constant current operation, harmonic currents class C for loads of 50W and above, low power source approval, class I & class II operation and a wide input voltage range of 90 to 305VAC, the convection cooled 80W LCE80 4” x 2” open frame power supply meeting the latest environmental legislation provides a solution for wide ranging applications in lighting, display, industrial electronics and ITE applications. ## **Features** - 80W convection cooled ## **Applications** - 4” x 2” footprint - Constant voltage, constant current operation - Suitable for lighting and display applications - ITE & lighting safety approvals - 90 to 305VAC operation - Class I & class II operation - Harmonic currents class C **==> picture [160 x 17] intentionally omitted <==** **----- Start of picture text -----**<br> Displays Industrial Lighting Technology<br>Electronics<br>**----- End of picture text -----**<br> ## **Dimensions** 4.00” x 2.00” x 1.10” (101.6 ~~x 50~~ .8 x 2 ~~7.9 mm~~ ) - LPS approval for 12V and above - Less than 0.5W no load input power - -40˚C to +70˚C operating temperature - 3 year warranty ## **Models & Ratings** |Model Number<br>LCE80PS05|Output Voltage|Output Current<br>12.00A|Ripple & Noise<br>50mV|Efficiency(1)<br>85.5%| |---|---|---|---|---| ||5.0V|||| |LCE80PS12|12.0V|6.67A|120mV|88.8%| |LCE80PS15|15.0V|5.33A|120mV|87.1%| |LCE80PS20|20.0V|4.00A|120mV|88.3%| |LCE80PS24|24.0V|3.33A|120mV|88.1%| |LCE80PS30|30.0V|2.67A|240mV|88.3%| |LCE80PS36|36.0V|2.22A|240mV|88.8%| |LCE80PS42|42.0V|1.90A|240mV|89.4%| |LCE80PS48|48.0V|1.67A|240mV|88.2%| |LCE80PS54|54.0V|1.48A|240mV|89.9%| Notes: 1. Minimum average efficiencies measured at 25%, 50%, 75% & 100% of 80W load and 230VAC input. AC-DC POWER SUPPLIES ## LCE80 Series ## **Input** |Characteristic<br>Input Voltage - Operating|Minimum<br>90|Typical<br>115/230|Maximum<br>305|Units<br>VAC|Notes & Conditions| |---|---|---|---|---|---| |Input Frequency|47|50/60|63|Hz|| |Input Current - Full Load||0.8/0.42||A|115/230VAC| |Inrush Current|||70|A|230VAC cold start, 25°C| |No Load Input Power|||0.5|W|| |Earth Leakage Current||140/280|400|μA|115/230VAC/50Hz (Typ), 264 VAC/60Hz (Max)| |Input Protection|F3.15 A/250 V Internal fuse fitted in line and neutral.||||| ## **Output** |Characteristic<br>Output Voltage - V1|Minimum<br>5|Typical|Maximum<br>54|Units<br>VDC|Notes & Conditions<br>See Models and Ratings table| |---|---|---|---|---|---| |Initial Set Accuracy|||±0.5|%|50% load, 115/230VAC| |Output Voltage Adjustment|±5|±10||%|| |Minimum Load|0|||A|No minimum load required| |Start Up Delay|||2|s|115/230VAC full load.| |Hold Up Time|18|20||ms|Min at full load, 115VAC| |Drift|||±0.02|%|After 20 min warm up| |Line Regulation|||±1|%|90-264VAC| |Load Regulation|||±1|%|0-95% load, 5% in constant current mode| |Transient Response|||4|%|Recovery within 1% in less than 500μs or a 50-75% and 75-50%<br>load step| |Over/Undershoot|||7|%|Full load| |Ripple & Noise|||50/120/200|mV pk-pk|5V/12-24V/30-54V. 20MHz bandwidth and 10μF electrolytic<br>capacitor in parallel with 0.1μF ceramic capacitor.| |Overvoltage Protection|110||140|%|Vnom, auto recovery| |Overload Protection|100||107|% I nom|Constant current down to 50% of nominal voltage. See fig. 1.| |Short Circuit Protection|||||Trip and restart| |Temperature Coefficient|||0.02|%/˚C|| **==> picture [82 x 27] intentionally omitted <==** **----- Start of picture text -----**<br> Output Characteristics<br>Figure 1<br>**----- End of picture text -----**<br> **==> picture [229 x 134] intentionally omitted <==** **----- Start of picture text -----**<br> Constant Voltage<br>100<br>Constant Current<br>50<br>|<br>Hiccup Region |<br>|<br>|<br>0<br>0 95-107%<br>Load<br>Output Voltage (%)<br>**----- End of picture text -----**<br> 2 AC-DC POWER SUPPLIES ## LCE80 Series ## **General** |Characteristic<br>Efficiency|Minimum|Typical<br>88|Maximum|Units<br>%|Notes & Conditions<br>230VAC (see fig. 2 and 3)| |---|---|---|---|---|---| |Isolation: Input to Output<br>Input to Ground<br>Output to Ground|3000|||VAC|| ||1500|||VAC|| ||1500|||VAC|| |Switching Frequency|34||95|kHz|Main converter| ||68||86||PFC| |Power Density|||9|W/in3|| |Mean Time Between Failure||250||khrs|MIL-HDBK-217F, Notice 2 +25°C GB| |Weight||0.32(145)||lb(g)|| ## Efficiency vs Load Figure 2, LCE80PS12 Figure 3, LCE80PS24 **==> picture [378 x 393] intentionally omitted <==** **----- Start of picture text -----**<br> 100%<br>90%<br>80%<br>70%<br>115 VAC<br>230 VAC<br>60%<br>50%<br>10 20 30 40 50 60 70 80 90 100<br>Load<br>100%<br>90%<br>80%<br>70%<br>115 VAC<br>230 VAC<br>60%<br>50%<br>10 20 30 40 50 60 70 80 90 100<br>Load<br>Efficiency<br>**----- End of picture text -----**<br> 3 AC-DC POWER SUPPLIES ## LCE80 Series ## **Environmental** |Characteristic<br>Operating Temperature|Minimum<br>-40|Typical|Maximum<br>+70|Units<br>°C|Notes & Conditions<br>At low line, minimum operating temperature is -30°C,<br>see temperature derating curve| |---|---|---|---|---|---| |Storage Temperature|-40||+85|°C|| |Cooling|Convection cooled||||| |Humidity|5||95|%RH|Non-condensing| |Operating Altitude|||5000|m|| |Shock|±3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms (+/- 0.5msecs), half sine. Conforms to EN60068-2-27||||| |Vibration|Single axis 10-500 Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6||||| Temperature Derating Curve Figure 4 **==> picture [350 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>50<br>0<br>-40 -30 0 +50 +70<br>Ambient Temperature (ºC)<br>High Line Only<br>Output Load (%)<br>**----- End of picture text -----**<br> 4 AC-DC POWER SUPPLIES ## LCE80 Series ## **EMC: Emissions** **==> picture [539 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test Level Criteria Notes & Conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test Level|Criteria|Notes & Conditons| |---|---|---|---|---| |Conducted|EN55032,<br>EN55015|Class B||| |Radiated|EN55032,<br>EN55015|Class B||| |Harmonic Current|EN61000-3-2|Class A, C||Class C for 50W load and above| |Voltage Functions|EN61000-3-3|||| ## **EMC: Immunity** **==> picture [539 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test Level Criteria Notes & Conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test Level|Criteria|Notes & Conditons| |---|---|---|---|---| |Low Voltage PSU EMC|EN55035,<br>EN61547||as below|| |ESD Immunity|EN61000-4-2|3|A|| |Radiated Immunity|EN61000-4-3|3|A|| |EFT|EN61000-4-4|3|A|| |Surge|EN61000-4-5|Installation class 4|A|| |Conducted|EN61000-4-6|3|A|| |Magnetic Fields|EN61000-4-8|3|A|| |Dips and Interruptions|EN61000-4-11<br>(100VAC)|Dip >95% (0VAC),<br>8.3ms|<br>A|| |||Dip 30% (70VAC),<br>416ms|<br>A|| |||Dip >95% (0VAC),<br>4160ms|<br>B|| ||EN61000-4-11<br>(240VAC)|Dip >95% (0VAC),<br>10.0ms|<br>A|| |||Dip 30%<br>(168VAC), 500ms|A|| |||Dip >95% (0VAC),<br>5000ms|<br>B|| ## **Safety Approvals** |Certfcaton|Standard|Notes & Conditons| |---|---|---| |CB Report|IEC60950-1-1, IEC62368-1|Information Technology| |UL|UL62368-1, UL8750|Information Technology & Lighting| |EN|EN62368-1, EN61347-1|Information Technology & Lighting| |CE|Meets all applicable directives|| |UKCA|Meets all applicable legislation|| 5 AC-DC POWER SUPPLIES ## LCE80 Series ## **Mechanical Details** **==> picture [509 x 278] intentionally omitted <==** **----- Start of picture text -----**<br> 4.00 (101.6)<br>0.13 (3.3) 3.75 (95.2)<br>CN1 CN1<br>3 VR Pin Function<br>CN2<br>1 1 AC-L<br>1<br>2 3 AC-N<br>3<br>4<br>5<br>6<br>CN2<br>4-ø 0.126 (3.2) Pin Function<br>1 +Vo<br>2 +Vo<br>3 +Vo<br>4 -Vo<br>5 -Vo<br>6 -Vo<br>1.74 (44.3) 2.00 (50.8)<br>0.13 (3.3)<br>1.00 (25.0)<br>0.12 (3.0) max 1.10 (27.9) max<br>**----- End of picture text -----**<br> Input and output connectors (CN1 & CN2) mate with JST housing VHR series and JST SVH-21/41T-P1.1 series crimp terminal or equivalent. Mounting holes marked with must be connected to safety earth in Class I applications or connected together in Class II application. ## **Notes:** 1. All dimensions are in inches (mm). Tolerance: ±0.02 (0.5) 2. Weight: 0.32lbs (145g) approx. **==> picture [148 x 49] intentionally omitted <==** 6 07 November 2024
Updated at June 8, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →