LCC600-28U-9P
AC/DC Enclosed Power Supply (PSU), Medical, 1 Outputs, 600 W, 28 VDC, 25 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: ARTESYN / ADVANCED ENERGY
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:600W; Output Voltage - Output 1:28V; Output Current - Output 1:25A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Volta
- SVHC: No SVHC (15-Jan-2018)
- Product Range: LCC600 Series
- No. of Outputs: 1Outputs
- Output Power Max: 600W
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable
- Output Current - Output 1: 25A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 28VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: Medical
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 237.79 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **ARTESYN LCC600** 600 Watts Conduction Cooling Advanced Energy's Artesyn LCC600 series of fully enclosed conduction cooled AC-DC power supplies comprises four models, offering main output voltages of 12 V, 28 V, 36 V or 48 V. Each model also provides a 5 Vdc standby output that can supply up to 1.5 amps. Rated at 600 watts, these power supplies incorporate a thermal baseplate and are capable of delivering full output power over a wide operating temperature range of -40 to 85˚C. For maximum applications flexibility, the main output is adjustable. The 48 V model, for example, can be adjusted from 44 to 54 V and has a maximum current rating of 12.5 amps. ## **SPECIAL FEATURES** ## **COMPLIANCE** - EMI Class B - 600 W full power at elevated temperatures - EN61000 Immunity - Wide operating temperature range (-40 °C to 85 °C baseplate) ## **SAFETY** - Adjustable output - UL + CSA: 62368-1 2nd Ed. ANSI ES60601-13 UL 87505 CSA-C22.2 No. 250.135 - TÜV: 62368-1 2nd Ed. 60601-1 3rd Ed.3 EN 61347-1; -2-135 - Remote output On/Off - AC_OK; DC_OK signals - 5 V standby voltage - Active current share - Conduction-cooled/fanless - I2C / PMBus > CB Scheme: IEC 60950-1 IEC 62368-1 IEC 60601-1 IEC 61347-1; -2-135 > China CCC - Medical and ITE Safety3 - Suited for BF-type applications - Active power factor correction - Optional IP65 variant - Optional 277 Vac input variant - CE and UKCA Mark ## **AT A GLANCE** ## **Total Power** ## **600 W** ## **# of Outputs** **Single** ## **Outputs** **12, 28, 36, 48 VDC** - ** LCC600 tested according to the medical standard IEC 60601-1-2 4th Edition. ©2022 Advanced Energy Industries, Inc. **LCC600** ## **ELECTRICAL SPECIFICATIONS** **==> picture [479 x 288] intentionally omitted <==** **----- Start of picture text -----**<br> Input<br>Input ra nge U Suffix: 90 - 264 Vac (Safety rating:100 - 240 Vac)<br>127 - 374 Vdc4<br>H Suffix: 180 - 305 Vac (Safety rating: 200 - 277 Vac)<br>254 - 420 Vdc4<br>Frequency 47 - 63 / 440 Hz (Safety rating: 50/60 Hz)<br>Input fusing Internal fuse on both L and N lines (12.5 A - U suffix; 7 A - H suffix)<br>EMI/RFI FCC Class B, CISPR22/EN55022 Class B<br>MIL-STD-461F EMI1 Compliance to CE101, 102; CS101, 114, 115, 116 (with external filter1)<br>Inrush current ≤ 25 A peak<br>Power factor 0.99 typical<br>Harmonics Meets EN61000-3-2 Class A and Class C2<br>Input current < 10 Arms @ 100 Vac<br>Hold up time 20 ms min for Main Output (230 Vac) @ 100% Load<br>Efficiency 93.3% typical @ 230 Vac; 100% Load; 28 Vdc<br>Leakage current3 U Suffix: 115 µA typical (< 200 µA max per ANSI/ES60601-1 264 Vac<br>split-phase / 60 Hz)<br>387 µA typical (< 500 µA max per IEC60601-1; 264 Vac / 50Hz)<br>H Suffix: 0.2 mA typical (< 3.5 mA max per ITE 62368-1 Standard)<br>Isolation voltage U Suffix H Suffix<br>PRI-SEC: 4,000 Vac (2X MOPP) 3,000 Vac<br>PRI-Chassis: 1,500 Vac (1X MOPP) 2,000 Vac<br>SEC-Chassis: 1,500 Vac (1X MOPP) 1,500 Vac<br>**----- End of picture text -----**<br> - 1 Artesyn Filter PN: 700-014447-0000 (Zhongguang PN: ZGLPG-10-02M). - 2 Meets Class C ≥ 50% load. - 3 U suffix have both ITE and Medical Safeties. H suffix carries ITE approval only. - 4 DC input rating not part of product’s Safety approval. - 5 LED Lighting approvals apply to all 48 V output variants. **2 advancedenergy.com** **LCC600** ## **ELECTRICAL SPECIFICATIONS (CONTINUED)** **==> picture [479 x 343] intentionally omitted <==** **----- Start of picture text -----**<br> Output<br>Output rating See Ordering Information table<br>Standby output 5.0 Vdc @ 1.5 A Max<br>Set point ± 0.5% Factory set point<br>Total regulation Main Output: ± 2.0% Combined Line / Load / Temperature<br>5 Vsb: ± 5%<br>Rated load 600 W maximum 600 W from -40 °C to 85 °C Baseplate Temp. Derate<br>output to 28 W @ 95 °C Baseplate Temp<br>Minimum load 0 A For both Main and 5 Vsb Outputs<br>Output voltage adjust range See Ordering Information table Max power limited to 600 W<br>Output noise Main Output: 1.0% max p-p Measured with 0.1 µF Ceramic and 10 µF Tantalum<br>5 Vsb: 60 mV max p-p Cap, 20 MHz BW<br>Remote sense Compensation up to 500 mV Pin 10: +Vout_RS / Pin4: -Vout_RS<br>Overcurrent protection 105 - 130% of full load current Default is Shutdown mode with Auto-retry every 2~4<br>sec. Output latches after 20 sec of continuous OCP<br>fault presence. Restart after latch possible through<br>AC recycle, Inhibit toggle or through PMBus.<br>Overvoltage protection 125 - 145% Vo, nom Main Output Latching / AC Recyle or Inhibit toggle required for<br>125 - 130% 5 Vsb PSU restart<br>Overtemperature protection > 95 °C Baseplate temperature Output Shutdown / Auto-recovery<br>AC_OK Open Collector; 0.8 Vdc max / 10 mA Active low when AC is present<br>DC_OK Open Collector; 0.8 Vdc max / 10 mA Active low when Main Output is within regulation<br>Remote inhibit Contact Closure Pin 19: Open/Float = ON; Close/Ground = OFF<br># Units in parallel operation Qualified up to 5 units in parallel. Consult Pin 5: IShare pin for main output only.<br>factory if more than 5 are required.<br>Output dimming 0-10 Vdc external voltage; Consult with productsupport.ep@artesyn.com<br>0-100 kOhm external resistance<br>**----- End of picture text -----**<br> ## **ENVIRONMENTAL SPECIFICATIONS** **==> picture [479 x 142] intentionally omitted <==** **----- Start of picture text -----**<br> Operating temperature range -40 °C to +85 °C Baseplate temperature<br>Storage temperature -40 °C to +85 °C<br>Humidity 10% to 95%<br>Altitude 16,402 ft (Operating) / 50,000 ft (Non-Operating)<br>Shock MIL-STD-810F 516.5 Procedure I, VI<br>Vibration MIL-STD-810F 514.5 Cat. 4, 10<br>Ingress protection IP65 (for suffix “-4P”)<br>MTBF (calculated) >2M Hrs, 25 °C per SR-332 Issue 3<br>Electromagnetic immunity Designed to meet EN61000-4-3, -4, -5, -8, -11 (Level 3); EN61000-4-2 (Level 4); EN60601-1-2 and EN55024<br>For H suffix, Level 4 for EN61000-4-5<br>**----- End of picture text -----**<br> **advancedenergy.com 3** **LCC600** ## **ORDERING INFORMATION** **==> picture [479 x 165] intentionally omitted <==** **----- Start of picture text -----**<br> AC Input Output Setpoint Adjustment Output Current [A] Max O/P Typical Standby<br>Model Number*<br>(Vac) Setpoint Tolerance Range Min Max Power [W] Efficiency** Output<br>LCC600-48U-4PD(1) 90 - 264 54 V ±0.5% 44 - 54 V 0 11.1 600 93.0% 5 Vdc @ 1.5 A<br>LCC600-48U-9P 90 - 264<br>48 V ±0.5% 44 - 54 V 0 12.5 600 93.0% 5 Vdc @ 1.5 A<br>LCC600-48H-9P 180 - 305 V<br>LCC600-36U-9P 90 - 264<br>36 V ±0.5% 32 - 38 V 0 16.7 600 92.0% 5 Vdc @ 1.5 A<br>LCC600-36H-9P 180 - 305<br>LCC600-28U-9P24 90 - 264 24 V ±0.5% 24 - 30 V 0 25 600 93.0% 5 Vdc @ 1.5 A<br>LCC600-28U-9P 90 - 264<br>28 V ±0.5% 24 - 30 V 0 25*** 600 93.5% 5 Vdc @ 1.5 A<br>LCC600-28H-9P 180 - 305<br>LCC600-12U-9P 90 - 264<br>12 V ±0.5% 12 - 15V 0 50 600 92.3% 5 Vdc @ 1.5 A<br>LCC600-12H-9P 180 - 305<br>**----- End of picture text -----**<br> *Change suffix “-9P” to “-4P” for IP65 rated enclosure with fly lead wires *Change suffix “-4P” to “-4PR” for IP65 rated enclosure with right angle fly lead wires (applies to 28, 36, 48 Vdc) *Change suffix “-4P” to “-4PV” to omit the control cable (applies to 28, 36, 48 Vdc) *Add suffix “24” after “P” to designate output voltage factory set to 24V (only on 28V models like LCC60028H-4P24CC) *Add suffix “CC” for Constant Current setting (e.g. “-4PCC”; “-9PCC”). **Typical efficiency at high line, factory default voltage and full load ***When Vout is adjusted down to 24 V, the supply can deliver 25 A max (600 W max). At 28 V default output setting, max Iout is 21.43 A (600 W max). (1) “D” suffix for 0-10 Vdc analog external volatge dimming (11.1 A CC limit). Consult Technical Reference Notes for additional details. Warranty: 2 years **4 advancedenergy.com** **LCC600** ## **MECHANICAL DRAWINGS** **==> picture [43 x 14] intentionally omitted <==** **----- Start of picture text -----**<br> -9P Suffix<br>**----- End of picture text -----**<br> **==> picture [409 x 288] intentionally omitted <==** **----- Start of picture text -----**<br> 228 0.50<br>@ e C) ©) C) e) OC)<br>4 -POSITION TERMINAL BLOCK SIGNAL PIN LOCATIONS<br>M4x8 SCREW, 10mm PITCH<br>(TYCO P/N: 1-350943-0 OR EQUIVALENT)3-POSITION LOCKING CONNECTOR + a WITH PLASTIC COVER(SEE NOTE 7) PIN 2 \ / P IN 1<br>MATE WITH TYCO P/N: 350766-1 (HOUSING)<br>& 350536-1 (CONTACT TERMINAL)<br>5 ae | ATESYN =e T RIMPOT WINDOW ==<br>@ @O0 @ 0 @ ) e ca a<br>MODEL LABEL PIN 20 PIN 19<br>HEADER CONNECTOR<br>(J1501)<br>MATE WITH P/N: JST PN PHDR-20VS (HOUSING)<br>& JST PN SPHD-001T-P0.5 (CONTAC PINS)<br>228 0.50 (SEE PIN LOCATION DETAILS) 85.0 0.50<br>(2.2)<br>' a = im<br>(35.50) 0.20 101 0.50<br>73.34 73.34 40.66<br>e e ° T<br>@ Cs)<br>e e o e Y<br>CUSTOMER MOUNTING HOLE<br>FIT WITH M4 SCREW<br>(6 PL)<br>(29.7) +0.739.8 -0.3<br>93.00<br>**----- End of picture text -----**<br> **==> picture [17 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> Notes:<br>**----- End of picture text -----**<br> - 1) Recommended mounting screw is M4 in 6 locations; 8-10 kgf-cm torque. - 2) Baseplate material/finish: 5 mm Aluminum with Black Anodized. - 3) Weight: 9P Suffix: 1.63 kg typical - 4P Suffix: 1.81 kg typical - 4) Thermal hotspot reference is in the middle of the baseplate. **advancedenergy.com 5** **LCC600** ## **MECHANICAL DRAWINGS (CONTINUED)** **==> picture [470 x 538] intentionally omitted <==** **----- Start of picture text -----**<br> -4P Suffix (28, 36, 48 Vdc)<br>> 300 10 228 0.5 300 10<br>SJTW 18AWGX3C U L2517 14AWGX4C (30)<br>(30)<br>U L2517 26AWGX20C+AL<br>290 10<br>MODEL LABEL TRIMPOT LOCATION<br>228 0.5<br>84.41 0.5<br>(50.5) 0.2 85 0.5<br>C USTOMER MOUNTING HOLE 4.6 101 0.5<br>FIT WITH M4 SCREW<br>(6 PL)<br>C UT EXPOSED LEADS OF SIGNAL WIRES<br>(2-73.3)<br>-— (2-146.7) (2-40.7)<br>-4P Suffix (12 Vdc)<br>300 10 228 0.5 3X- 307 10<br>HEIGHT MEASUREMENT 59 0.5 U L2517<br>REFERENCE POINT 26AWGX20C<br>SEE NOTE 9<br>TIN DIP<br>T IN DIP<br>ARTESYN P/N:<br>(INPUT CABLE ASSY)750-006769-000X A 750-007030-00XXRTESYN P/N: T AWG 6 WIREHW OR MTW<br>(OUTPUT CABLE ASSY)<br>RATING AND SAFETY LOGO LABEL TRIMPOT LOCATION<br>85 0.50<br>(50.5) 0.2 101 0.50<br>C USTOMER MOUNTING HOLE 4.6<br>FIT WITH M4 SCREW (SEE NOTE 8)<br>(6 PL)<br>(2X-73.3)<br>(2X-146.7) (2X-40.7)<br> +0.7 -0.3<br>39.8<br>(21.4) 8.5<br>93.0)(3-<br>0.5<br>46 40.50max<br>(22) (24)<br>5)(<br>93)(3X-<br>**----- End of picture text -----**<br> **6 advancedenergy.com** **LCC600** ## **MECHANICAL DRAWINGS (CONTINUED)** ## **-4PR Suffix (28, 36, 48 Vdc)** **==> picture [441 x 433] intentionally omitted <==** **----- Start of picture text -----**<br> 265.0 2.0<br>228 0.5 — 40.5 MAX<br>HEIGHT MEASUREMENT<br>REFERENCE POINT<br>| |<br>TRIMPOT<br>MODEL<br>LOCATION<br>LABEL<br>. 4<br>U L2517 26AWGX20C+AL<br>U L2517 14AWGX4C<br>0.2<br>|<br>T IN DIP WIRES<br>0.2<br>;<br>SJTW 18AWGX3C<br>146.68<br>40.66 73.34 73.34<br>7 ee<br>C USTOMER MOUNTING HOLE 4.6<br>FIT WITH M4 SCREW<br>0.5<br>101<br>45<br>45<br>80.1 10<br>10 300<br>300<br>10<br>30<br>93 (3X)<br>**----- End of picture text -----**<br> **advancedenergy.com 7** **LCC600** ## **PIN ASSIGNMENT (INPUT)** **==> picture [479 x 69] intentionally omitted <==** **----- Start of picture text -----**<br> -9Px Suffix -4Px Suffix<br>DESCRIPTION DESIGNATION NOTES DESIGNATION NOTES<br>Live L1 Brown<br>Mating Connector: SJTW 18AWGX3C;<br>Neutral L2 350766-1 (Housing); Blue PVC jacket;<br>Ground G 350536-1 (Contact Terminals) Y/GR 105 °C / 300 V<br>**----- End of picture text -----**<br> ## **PIN ASSIGNMENT (MAIN OUTPUT)** **==> picture [479 x 92] intentionally omitted <==** **----- Start of picture text -----**<br> -9Px Suffix -4Px Suffix (28, 36, 48 Vdc) -4Px Suffix (12 Vdc)<br>DESCRIPTION DESIGNATION NOTES DESIGNATION NOTES DESIGNATION NOTES<br>4 Position Terminal Block: M4 Red<br>Main Output +Vout Screw/10mm Pitch; 12kgf-cm Red 14AWGX4C; Red 6AWG Multi-Strand;<br>Torque; Accepts 14-16AWG Ring<br>PVC jacket; PVC jacket;<br>Tongue - Spade Terminals MOLEX Black<br>Main Output Return GND -Vout BB-124-08 (19141-0058) or 105 °C / 300 V Black 105 °C / 600 V<br>EQUIVALENT Black<br>**----- End of picture text -----**<br> ## **PIN ASSIGNMENT** **==> picture [479 x 299] intentionally omitted <==** **----- Start of picture text -----**<br> J1501 - Signal & Control -9Px Suffix -4Px Suffix<br>SIGNALS DESCRIPTION PIN # NOTES Wire Color NOTES<br>A2_OUT EEPROM Address 1 BLACK<br>GND Ground 2 BROWN<br>A1_OUT EEPROM Address 3 RED<br>-VOUT_RS Remote Sense Return (Main O/P) 4 ORANGE<br>ISHARE Load Share Voltage 5 YELLOW<br>A0_OUT EEPROM Address 6 GREEN<br>SDA Serial Data Signal (I2C) 7 BLUE<br>SPARE_1 Spare/Unused Pin (Dimming input for “-4PD” suffix) 8 VIOLET<br>J1501 Mating Connector:<br>SCL Serial clock Signal (I2C) 9 GRAY<br>JST PN<br>+VOUT_RS Remote Sense (Main O/P) 10 PHDR-20VS WHITE 26AWGX20C+AL;<br>PVC jacket;<br>5VSB 5V Standby (1.5A Max) 11 PINK 105 °C / 300 V<br>Contact Pins:<br>SGND 5V Standby Return 12 LIGHT BLUE<br>JST PN SPHD-001T-P0.5<br>SPARE_2 Spare/Unused Pin 13 WHITE/VIOLET<br>G_DCOK_C Global DC_OK Collector 14 WHITE/YELLOW<br>WP EEPROM Write Protect 15 WHITE/ORANGE<br>G_DCOK_E Global DC_OK Emitter (GND) 16 WHITE/BLACK<br>GND Return GND for O/P Signal and I2C communication 17 WHITE/RED<br>G_ACOK_C Global AC_OK Collector 18 WHITE/BROWN<br>INH_EN Output Inhibit_Enable Pin (turns output off) 19 WHITE/GREEN<br>G_ACOK_E Global AC_OK Emitter (GND) 20 WHITE/BLUE<br>**----- End of picture text -----**<br> **8 advancedenergy.com** **LCC600** **==> picture [89 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> THERMAL SENSING<br>**----- End of picture text -----**<br> |**Location**|**PMBus ADDR**|**Max Temp**| |---|---|---| |Internal Secondary Output (near base plate)|8Dh|111 °C| |Internal Primary Hotspot (at FET Heatsink)|8Eh|124 °C| |Internal Primary Input Hotspot (near base plate)|8Fh|101 °C| ## **POWER DERATING CURVES** Figure 1. Output Power vs. Baseplate Temperature Figure 2. Output Power vs. Input Voltage ## **EFFICIENCY CURVES** Figure 3. Typical Efficiency for 28 V output Figure 4. Typical Efficiency for 48 V output Figure 5. Typical Efficiency for 36 V output Figure 6. Typical Efficiency for 12 V output **advancedenergy.com 9** **LCC600** **==> picture [478 x 646] intentionally omitted <==** **----- Start of picture text -----**<br> MTBF VS. AMBIENT TEMPERATURE<br>a<br>2,500,000 Ambient Temperature MTBF<br>2,000,000 25 ºC 2,000,000<br>35 ºC 1,000,000<br>1,500,000<br>1,000,000 45 ºC 500,000<br>1,000,000<br>500,000 55 ºC 250,000<br>500,000 250,000 125,000 62,500 31,250 65 ºC 125,000<br>0 25 ºC 35 ºC 45 ºC 55 ºC 65 ºC 75 ºC 85 ºC 75 ºC 62,500<br>Ambient Temperature ºC 85 ºC 31,250<br>— ——<br>MTBF<br>ACCESSORIES<br>eS<br>Orderable Part Number Description Diagram<br>70-841-030 For Suffix "-9P" AC Input Mating Connector Cable Assembly<br>(w/ 0.3 m wire length)<br>73-788-001 J1501 (20 Pin Control Signal) Mating Connector with 0.3 m PIN 20 PIN 19<br>wires attached for "-9P" suffix<br>PIN 3<br>PIN 2 PIN 1<br>300 ± 5 mm<br>OT<br>70-841-031 Pre-Cut thermal insulator (Laird TFLEX HR220FG)<br>700-014447-0000 MIL-STD-461F AC input In-line EMI filter (Zhongguang ZGLPG-<br>Se 10-02M)<br>ae<br>73-769-002 USB to I2C High Speed Adaptor for PMBus Communication<br>NE<br>73-769-007 J1501 (20 Pin) Mating connector with 10 Pin header A 2 15±5 O 500±5 1 50±3<br>termination for use with 73-769-002 C M (17X) 300±3 50.0±3<br>17 F E (15 ) A B<br>3 24<br>97<br>1 15±3<br>D<br>1 5±3<br>ee<br>466-003103-0000 Test Heatsink for unit characterization. Size: 331 x 220 x 69<br>mm; Aluminum with natural finish; Weight = 1.7 kgs<br>Po<br>MTBF (Hrs)<br>**----- End of picture text -----**<br> **10 advancedenergy.com** **==> picture [596 x 270] intentionally omitted <==** ## **ABOUT ADVANCED ENERGY** Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. Our products enable customer innovation in complex applications for a wide range of industries including semiconductor equipment, industrial, manufacturing, telecommunications, data center computing, and medical. With deep applications know-how and responsive service and support across the globe, we build collaborative partnerships to meet rapid technological developments, propel growth for our customers, and innovate the future of power. For international contact information, visit advancedenergy.com. powersales@aei.com (Sales Support) productsupport.ep@aei.com (Technical Support) +1 888 412 7832 Specifications are subject to change without notice. Not responsible for errors or omissions. ©2022 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, AE® and Artesyn™ are U.S. trademarks of Advanced Energy Industries, Inc. ENG-LCC600-235-01 1.19.22
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →