LBA100US24
AC/DC Enclosed Power Supply (PSU), ITE, Industrial, LED Lighting, 1 Outputs, 100 W, 24 V, 4.2 A
- Manufacturer: XP POWER
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (04-Feb-2026)
- Product Range: LBA100 Series
- No. of Outputs: 1Outputs
- Output Power Max: 100W
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 4.2A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 24V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Industrial, LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 12.25 € |
| Current stock | 10+ |
| Lead time | 30 days |
LBA100 series ## 100W **Convection cooled** ## **AC-DC power supplies** The LBA100 series of compact, convection-cooled 100W AC-DC power supplies are designed to deliver quiet, consistent performance across a wide range of industrial technology applications. With a wide input range, regulated single output voltages from 5V to 48VDC and output voltage adjustment, the LBA100 series provides engineers with a versatile and robust power platform suitable for demanding industrial environments. Featuring Class B conducted and radiated emissions, worldwide ITE safety approvals, wide temperature range, compact footprint, a power “ON” LED and an integrated connector cover, the LBA100 is designed for easy integration into applications including auxiliary power units, security and surveillance systems, industrial automation, lighting control, smart home and building control equipment. ## **Features** - f 100W convection cooled - f Universal, single phase input: 90 to 264VAC - f Regulated single outputs from 5V to 48VDC - f ITE safety approvals - f Class B conducted & radiated emissions - f Integrated connector cover - f Output voltage trim - f Efficiency, up to 86% - f Short circuit, overvoltage & overload protection **==> picture [137 x 110] intentionally omitted <==** **----- Start of picture text -----**<br> Applications<br>a ,<br>Smart home Instrumentation Industrial<br>electronics<br>Robotics Technology<br>**----- End of picture text -----**<br> **==> picture [152 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions<br>(<br>**----- End of picture text -----**<br> 129.0 x 97.0 x 30.0 mm (5.08” x 3.82” x 1.18”) **==> picture [74 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Documentation<br>**----- End of picture text -----**<br> **==> picture [136 x 47] intentionally omitted <==** **----- Start of picture text -----**<br> For further information click the link or scan<br>the code<br>5 xppower.com<br>**----- End of picture text -----**<br> - f LED power ON status indicator - f -30°C to +70°C operating temperature f 3 year warranty ## **Models & ratings** ~~Lo~~ |Model number|Output voltage|Output voltage|Output current|Ripple & noise<br>pk to pk(1)|Efficiency(2)|Maximum<br>capacitive load|Power| |---|---|---|---|---|---|---|---| ||Nominal|Adjustment range(3)|||||| |LBA100US05|5.0V|4.5 - 5.5V|16.0A|100mV|83%|6000μF|80W| |LBA100US12|12.0V|10.8 - 13.2V|8.4A|120mV|85%|3600μF|100W| |LBA100US15|15.0V|13.5 - 16.5V|6.7A|120mV|85%|1800μF|100W| |LBA100US24|24.0V|21.6 - 26.4V|4.2A|150mV|85%|900μF|100W| |LBA100US48|48.0V|44.0 - 52.0V|2.2A|200mV|86%|120μF|105W| ## Notes: 1. Ripple & noise measured with 20MHz bandwidth and using 20±2cm twisted pair-wire terminated with 47μF electrolytic capacitor in parallel with 0.1μF ceramic capacitor. 2. Typical efficiencies measured at 230VAC full load. 3. The total output power must not exceed the rated output power. 1 **AC-DC power supplies** ## LBA100 series ## **Input** **==> picture [554 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Input voltage - operating|90|115/230|264|VAC|Derate output power linearly from 100% at 115VAC to 80% at 90VAC.| |Input frequency|47|50/60|63|Hz|| |Input current|||2.0|A|115VAC full load| ||||1.2||230VAC full load| |No load input power|||0.9|W|| |Inrush current|||35|A|115VAC cold start at +25°C ambient| ||||70||230VAC cold start at +25°C ambient| |Earth leakage current|||1.0|mA|240VAC / 50Hz| |Input protection|T3.15A/250VAC Internal fuse ftted in line||||| ## **Output** **==> picture [554 x 17] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons|Notes & conditons| |---|---|---|---|---|---|---| |||||||| |Output voltage|5||48|VDC|See Models & Ratings table|| |Initial set accuracy|||±2|%|Full load|LBA100US05| ||||±1|||All other models| |Voltage adjustment|See Models & Ratings table|||||| |Minimum load|0|||A|No minimum load|required| |Start up time|||2.5|s|115 & 230VAC full|load at +25°C| |Rise time|||50|ms|115 & 230VAC full|load| |Hold up time|10/20|||ms|115 / 230VAC full load|| |Drift|||±0.03|%|After 20 minutes warm up, 230VAC, 0°C to +50°C|| |Line regulation|||±0.5|%|100-264VAC, full load|| |Load regulation|||2|%|From 0-100%<br>load|LBA100US05| ||||1|||All other models| |Transient response|||4|%|Recovery within 1% in less than 0.5ms for a 50-75% and 75-50%<br>load step|| |Ripple & noise|See Models & Ratings table|||||| |Over / Undershoot|||10|%|Full load|| |Overvoltage protection|110||140|%|5V-24V models|| ||||60|V|48V model|| |Overload protection|110||160|%|Nominal output current, auto recovery|| |Temperature coeffcient||±0.03||%/°C|0 to +50°C|| |Short circuit protection|Continuous hiccup with auto recovery|||||| ## Notes: 1. All specifications valid at 230VAC, full load and +25°C , unless otherwise stated Specifications subject to change without notice. 2 **AC-DC power supplies** ## LBA100 series ## **General** **==> picture [554 x 26] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>Efficiency See Models & Ratings table<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| |Effciency|See Models & Ratings table||||| |Isolation: input to output<br>input to ground<br>output to ground|3000|||VAC|Class I construction| ||1800|||VAC|| ||500|||VAC|| |Switching frequency||65||kHz|Full load| |Power density|||0.266 (4.36)|W/cm3(W/in3)|| |Mean time between failure|300|||khrs|MIL-HDBK-217F, Notice 2 +25°C GB.| |Weight||300 (0.661)||g (lb)|| |Case material|Aluminium chassis with vented galvanized steel cover||||| ## **Environmental** **==> picture [554 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Operating temperature|-30||+70|°C|See derating curve| |Storage temperature|-40||+85|°C|| |Cooling|Natural convection||||| |Humidity|20||95|%RH|Non-condensing| |Operating altitude|||2000|m|| |Vibration|Tested according to EN60068-2-27, 10-500Hz, 5g (1H) for each X, Y and Z plane||||| ## **EMC: emissions** **==> picture [554 x 17] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test level Notes & conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test level|Notes & conditons| |---|---|---|---| ||||| |Conducted|EN55032|Class B|| |Radiated|EN55032|Class B|| |Voltage ficker|EN61000-3-3||| ## **EMC: immunity** **==> picture [554 x 17] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test level Criteria Notes & conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test level|Criteria|Notes & conditons| |---|---|---|---|---| |||||| |ESD immunity|EN61000-4-2|2/3|B|Contact ±4kV / Air ±8kV| |Radiated immunity|EN61000-4-3|10V/m|B|| |EFT|EN61000-4-4|±2kV|B|| |Surge|EN61000-4-5|Installation class 3|B|Line to line ±1kV, line to ground ±2kV| |Conducted|EN61000-4-6|10Vrms|A|| |Magnetic feld|EN61000-4-8|30AVm|A|| |Dips|EN61000-4-11<br>(230VAC)|Dip. 100% (0VAC), 10ms|B|| |||Dip. 30% (154VAC), 500ms|B|| |||Dip. 20% (176VAC), 5000ms|B|| |Interruptions|EN61000-4-11|Int. 100% (0VAC), 5000ms|C|| ## Notes: 1. All specifications valid at 230VAC, full load and +25°C , unless otherwise stated 3 **AC-DC power supplies** ## LBA100 series ## **Safety approvals** **==> picture [554 x 17] intentionally omitted <==** **----- Start of picture text -----**<br> Certification Standard Notes & conditions<br>**----- End of picture text -----**<br> |Certfcaton|Standard|Notes & conditons| |---|---|---| |||| |CB|IEC62368-1|Information technology| |UL|UL62368-1|Information technology| |TUV|EN62368-1|Information technology| |CCC|China Compulsory Certifcation, GB4943, GB17625.1,<br>GB4943.1, GB/T9254|Information technology| |CE|Meets all applicable directives|| |UKCA|Meets all applicable legislation|| ## **Application notes** Temperature derating **==> picture [355 x 225] intentionally omitted <==** **----- Start of picture text -----**<br> 100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>0%<br>-30 [-25] -20 -10 0 10 20 30 40 50 60 70<br>Temperature (°C)<br>Output load (%)<br>**----- End of picture text -----**<br> Notes: 1. All specifications valid at 230VAC, full load and +25°C , unless otherwise stated 4 **AC-DC power supplies** ## LBA100 series ## **Mechanical details** **==> picture [469 x 484] intentionally omitted <==** **----- Start of picture text -----**<br> 3 - M3 (side)<br>32 [1.26] 77 [3.031]<br>6.5 [0.256]<br>2.5 [0.098]<br>129 ±1<br>[5.079 ±0.039]<br>122.5 [4.823]<br>4.5 [0.177]<br>L<br>N<br>-V<br>-V<br>+V<br>+V<br>3 - M3<br>(bottom)<br>Status<br>indicator<br>Vout<br>adjustment<br>36 [1.417] 42 [1.654]<br>Ø3.5 [Ø0.138]<br>Ø3.5 [Ø0.138]<br>3.5 [0.138]<br>30 ±1<br>18 [0.709]<br>26 [1.024] [1.181 ±0.039]<br>15 [0.591] 14.5 [0.571]<br>6<br> [0.236]<br>5.5<br> [0.217]<br>30 [1.181]<br>97 ±1 [3.819 ±0.039] 33 [1.299]<br>91.5 [3.602]<br>3.5 [0.138]<br>6.5 [0.256]<br>**----- End of picture text -----**<br> ## Notes: 1. All dimensions are in mm (inches). 2. Terminal screw tightening torque: M4 12N-m (1.2Kgf-cm) 3. Mounting screw tightening torque: M3 0.4N-m (4Kgf-cm) 4. Mounting screw penetration depth: 3mm max 5. Mounting screw length : 5mm 6. Chassis must be connected to protective earth 03 March 2026 5
Updated at June 10, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →