LA 55-P
Current Transducer, LA Series, 50A, -70A to 70A, 0.9 %, Closed Loop Output, 12 Vdc to 15 Vdc
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- Sensor Output:Closed Loop; Supply Voltage DC Min:-15V; Supply Voltage DC Max:15V; Current Measuring Range DC:-70A to 70A; Current Measuring Range AC:-70A to 70A; Response Time:1µs; Accuracy
- SVHC: No SVHC (25-Jun-2025)
- Accuracy: 0.65%
- Accuracy %: 0.9%
- Product Range: LA55 Series
- Response Time: 1µs
- Primary Current: 50A
- Sensor Mounting: Through Hole
- Measured Current: AC / DC / Pulsed
- Sensor Output Type: Closed Loop
- Supply Voltage Range: ± 12V to ± 15V
- Supply Voltage DC Max: 15V
- Supply Voltage DC Min: -15V
- Current Sensor Technology: Open Loop, Hall Effect
- Operating Temperature Max: 85°C
- Operating Temperature Min: -40°C
- Current Measuring Range AC: -70A to 70A
- Current Measuring Range DC: -70A to 70A
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 25.27 € |
| Current stock | 200+ |
| Lead time | 30 days |
## **Current Transducer LA 55-P** ## _I_ **= 50 A** P N For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. ## ~~**Electrical data** Lo~~ |_I_P N|Primary nominal RMS current|Primary nominal RMS current||50||A| |---|---|---|---|---|---|---| |_I_P M|Primary current, measuring range|||0 … ±70||A| |_R_M|Measuring resistance||@_T_A= 70 °C|= 70 °C_T_A= 85 °C||| ||||_R_M min _R_M max_R_M min||_R_M max|| ||with ±12 V|@ ±50 Amax<br>@ ±70 Amax|10<br>10|100<br>60<br>50<br>601)60|95<br>601)|Ω<br>Ω| ||with ±15 V|@ ±50 Amax|50|160<br>135|155|Ω| |||@ ±70 Amax|50|90<br>1352)135|1352)|Ω| |_I_S N<br>_N_P/_N_STurns ratio|Secondary nominal RMS current<br>Turns ratio|||50<br>1 : 1000||mA| |_U_C|Supply voltage (±5 %)|Supply voltage (±5 %)||±12 ... 15||V| |_I_C|Current consumption (±2)|||10(@ ±15 V) +_I_S||mA| ## ~~**Accuracy - Dynamic performance data** PO~~ |_ε_<br>_ε_L<br>_I_O<br>_I_O M|Error @_I_P N,_T_A= 25 °C @ ±15 V (±5 %)<br>@ ±12 … 15 V (±5 %)<br>Linearity error<br>Offset current @_I_P= 0,_T_A= 25 °C<br>Magnetic offset current3)@_I_P= 0 and specified_R_M,|±0.65<br>±0.90<br>< 0.15<br>Typ|±0.65<br>±0.90<br>< 0.15<br>Max<br>±0.2|%<br>%<br>%<br>mA| |---|---|---|---|---| ||after an overload of 3 ×_I_P N||±0.3|mA| |_I_O_T_|Temperature variation of_I_O<br>−25 °C … +85 °C|±0.1|±0.6|mA| ||−40 °C … −25 °C|±0.2|±1.0|mA| |_t_D 10|Delay time @ 10 % of_I_P N|< 500|< 500|ns| |_t_D 10|Delay time to 90 % of_I_P N<br>4)|< 1||µs| |_BW_<br>Frequency bandwidth (−1 dB)<br>DC … 200<br>kHz<br>~~**General data**~~<br>~~PO~~||||| |_T_A<br>_T_S<br>_R_S|Ambient operating temperature<br>Ambient storage temperature<br>Resistance of secondary winding<br>@_T_A= 70 °C<br>@_T_A= 85 °C|−40 … +85<br>−40 … +90<br>80<br>85||°C<br>°C<br>Ω<br>Ω| |_m_|Mass|18||g| ||Standards|EN 50178: 1997||| |||UL 508: 2010||| ## **Features** - ●Closed loop (compensated) current transducer using the Hall effect - ●Insulating plastic case recognized according to UL 94-V0. ## **Advantages** - ●Excellent accuracy - ●Very good linearity - ●Low temperature drift - ●Optimized response time - ●Wide frequency bandwidth - ●No insertion losses - ●High immunity to external interference - ●Current overload capability. ## **Applications** - ●AC variable speed drives and servo motor drives - ●Static converters for DC motor drives - ●Battery supplied applications - ●Uninterruptible Power Supplies (UPS) - ●Switched Mode Power Supplies (SMPS) - ●Power supplies for welding applications. ## **Application domain** - ●Industrial. Notes:[1)] Measuring range limited to ±60 A max 2) Measuring range limited to ±55 A max - 3) Result of the coercive field of the magnetic circuit - 4) For a d _i_ /d _t_ = 200 A/µs. 17September2018/version 17 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com N° 97.13.25.000.0 Page 1/3 ## **Current Transducer LA 55-P** ## ~~**Insulation coordination**~~ |_U_d|RMS voltage for AC insulation test, 50 Hz/1 min|2.5|kV| |---|---|---|---| |_U_Ni|Impulse withstand voltage 1.2/50 µs|5.7|kV| |||Min|| |_d_Cp|Creepage distance|5|mm| |_d_CI|Clearance|5|mm| |_CTI_|Comparative tracking index (group I)|600|| ## **Applications examples** **According to EN 50178 and IEC 61010-1 standards** and following conditions: - ●Over voltage category OV 3 - ●Pollution degree PD2 - ●Non-uniform field ||**EN 50178**|**IEC 61010-1**| |---|---|---| |_d_Cp,_d_CI,_U_Ni|Rated insulation voltage|Nominal voltage| |Basic insulation|300 V|300 V| |Reinforced insulation|150 V|150 V| ## **Safety** This transducer must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 17September2018/version 17 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com **Dimensions LA 55-P** (in mm) **==> picture [511 x 372] intentionally omitted <==** **----- Start of picture text -----**<br> Connection<br>I P<br>I S R M<br>U C<br>U C d Cl d Cp<br>**----- End of picture text -----**<br> ## **Mechanical characteristics** - ●General tolerance - ●Primary through-hole - ●Fastening & connection of secondary - ●Recommended PCB hole ±0.2 mm 12.7 × 7 mm 3 pins 0.6 × 0.7 mm - ⌀ 1.2 mm ## **Remarks** - _I_ S is positive when _I_ P flows in the direction of the arrow. - ●Temperature of the primary conductor should not exceed 90 °C. - ●Installation of the transducer must be done unless otherwise specified on the datasheet, according to LEM Transducer Generic Mounting Rules. Please refer to LEM document N°ANE120504 available on our Web site: **https://www.lem.com/en/file/3137/download/.** - ●Dynamic performances ( d _i_ /d _t_ and delay time) are best with a single bar completely filling the primary hole. - ●In order to achieve the best magnetic coupling, the primary windings have to be wound over the top edge of the device. - ●This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. Page 3/3 17September2018/version 17 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →