Image not available
Illustrative purposes only
LA 125-P
Current Transducer, LA Series, 125A, -200A to 200A, 0.6 %, Closed Loop Output, 12 Vdc to 15 Vdc
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- Sensor Output:Closed Loop; Supply Voltage DC Min:12V; Supply Voltage DC Max:15V; Current Measuring Range DC:-200A to 200A; Current Measuring Range AC:-200A to 200A; Response Time:1µs; Accuracy %
- SVHC: No SVHC (25-Jun-2025)
- Accuracy: 0.8%
- Accuracy %: 0.6%
- Product Range: LA125 Series
- Response Time: 1µs
- Primary Current: 125A
- Sensor Mounting: Through Hole
- Measured Current: AC / DC / Pulsed
- Sensor Output Type: Closed Loop
- Supply Voltage Range: ± 12V to ± 15V
- Supply Voltage DC Max: 15V
- Supply Voltage DC Min: 12V
- Current Sensor Technology: Closed Loop, Hall Effect
- Operating Temperature Max: 85°C
- Operating Temperature Min: -40°C
- Current Measuring Range AC: -200A to 200A
- Current Measuring Range DC: -200A to 200A
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 43.38 € |
| Current stock | 200+ |
| Lead time | 30 days |
## **Current Transducer LA 125-P**
## **I = PN**
## **125 A**
For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
## 2002/95/EC 16030
## **Electrical data**
**I** PN Primary nominal current rms 125 A **I** PM Primary current, measuring range 0 .. ± 200 A **R** M Measuring resistance @ **T** A = 70°C **T** A = 85°C **R R R R** M mini M maxi M mini M maxi with ± 12 V @ ± 125 A maxi 5 52 14 50 Ω @ ± 200 A maxi 5 20 14 18 Ω with ± 15 V @ ± 125 A maxi 25 74 40 72 Ω @ ± 200 A maxi 25 34 40[ 1)] 40[ 1)] Ω **I** SN Secondary nominal current rms 125 mA **K** N Conversion ratio 1 : 1000 **V** C Supply voltage (± 5 %) ± 12 .. 15 V **I** C Current consumption 16 (@ ± 15 V) + **I** S mA
## **Accuracy - Dynamic performance data**
**X** Accuracy @ **I** PN , **T** A = 25°C @ ± 15 V (± 5 %) ± 0.60 % @ ± 12 .. 15 V (± 5 %) ± 0.80 % **ε** L Linearity error < 0.15 % Typ Maxi **I** O Offset current @ **I** P = 0, **T** A = 25°C ± 0.40 mA **I** OM Magnetic offset current[ 2) ] @ **I** P = 0 and specified **R** M, after an overload of 3 x **I** PN ± 0.50 mA **I** OT Temperature variation of **I** O 0°C .. + 70°C ± 0.15 ± 0.50 mA - 40°C .. + 85°C ± 0.30 ± 0.95 mA **t** ra Reaction time @ 10 % of **I** PN < 500 ns **t** r Response time[ 3) 4)] to 90 % of **I** PN step < 1 µs **di/dt** di/dt accurately followed[ 4)] > 200 A/µs **BW** Frequency bandwidth[ 4)] (- 1 dB) DC .. 100 kHz **General data T** A Ambient operating temperature - 40 .. + 85 °C **T** S Ambient storage temperature - 40 .. + 90 °C **R** S Secondary coil resistance @ **T** A = 70°C 32 Ω **T** A = 85°C 33.5 Ω _**m**_ Mass 40 g Standards EN 50178: 1997
## **Features**
- Closed loop (compensated) current transducer using the Hall effect
- Printed circuit board mounting
- Isolated plastic case recognized according to UL 94-V0.
## **Advantages**
- Excellent accuracy
- Very good linearity
- Low temperature drift
- Optimized response time
- Wide frequency bandwidth
- No insertion losses
- High immunity to external interference
- Current overload capability.
## **Applications**
- AC variable speed drives and servo motor drives
- Static converters for DC motor drives
- Battery supplied applications
- Uninterruptible Power Supplies (UPS)
- Switched Mode Power Supplies (SMPS)
- Power supplies for welding applications.
## **Application Domain**
- Industrial.
- Notes: 1) Measuring range limited to ± 180 A maxi
- 2) The result of the coercive field of the magnetic circuit.
- 3) With a di/dt of 100 A/µs
- 4) The primary conductor is best filling the through-hole and/or the return of the primary conductor is above the top of the transducer.
page 1/3
070806/12
www .lem.com
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
## **Current Transducer LA 125-P**
## CT **Isolation characteristics**
|**V**d|Rms voltage for AC isolation test, 50/60 Hz, 1 min|3|kV|
|---|---|---|---|
|**V**w|Impulse withstand voltage 1.2/50 µs|7|kV|
|||Mini||
|**dCp**|Creepage distance|6.7|m m|
|**dCl**|Clearance distance|6.7|m m|
|**CTI**|Comparative Tracking Index (Group IIIa)|175||
## **Application examples**
**According to EN 50178 and IEC 61010-1 standards** and following conditions:
- Over voltage category OV 3
- Pollution degree PD2
• Non-uniform field
|• Over voltage category OV 3<br>• Pollution degree PD2<br>• Non-uniform field|Over voltage category OV 3<br>~~ee~~|~~ee~~|
|---|---|---|
||**EN 50178**<br>~~ee~~<br>~~es~~|**IEC 61010-1**<br>~~ee~~|
|dCp, dCI,<br>**VW**<br>~~ee~~|Rated isolation voltage<br>~~ee~~<br>~~ee~~<br>~~es~~|Nominal voltage<br>~~ee~~<br>~~ee~~|
|Single isolation|600 V<br>~~es~~<br>~~es~~|600 V|
|Reinforced isolation<br>~~ee~~|300 V<br>~~ee~~<br>~~es~~|300 V<br>~~ee~~|
## **Safety**
This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer's operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation.
A protective housing or additional shield could be used. Main supply must be able to be disconnected.
page 2/3
070806/12
www .lem.com
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
**==> picture [136 x 36] intentionally omitted <==**
**==> picture [33 x 33] intentionally omitted <==**
## **Dimensions LA 125-P** (in mm. 1 mm = 0.0394 inch)
**==> picture [511 x 387] intentionally omitted <==**
**----- Start of picture text -----**<br>
Bottom view Left view<br>Connection<br>Front view<br>**----- End of picture text -----**<br>
## **Mechanical characteristics**
## **Remarks**
- General tolerance
- ± 0.2 mm 17 x 11 mm
- Primary through-hole
- Fastening & connection of secondary 4 pins 0.63 x 0.56 mm Recommended PCB hole 0.9 mm
- Supplementary fastening 2 holes ∅ 1.75 mm Recommended PCB hole 2.4 mm Recommended screws PT KA 22 x 6 Recommended fastening torque 0.5 Nm or .37 Lb. - Ft.
- **I** S is positive when **I** P flows in the direction of the arrow.
- Temperature of the primary conductor should not exceed 90°C.
- Dynamic performances (di/dt and response time) are best with a primary bar in low position in the through-hole.
- In order to achieve the best magnetic coupling, the primary windings have to be wound over the top edge of the device.
- This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us.
page 3/3
070806/12
www .lem.com
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →