LA 100-TP
Current Transducer, Closed Loop Hall Effect, AC/DC/Pulsed, 100A, Analogue-50mA, ± 12V to 15V Supply
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- SVHC: No SVHC (25-Jun-2025)
- Accuracy: ± 0.45%
- Product Range: LA100P Series
- Primary Current: 100A
- Sensor Mounting: Through Hole
- Measured Current: AC / DC / Pulsed
- Sensor Output Type: Analogue
- Supply Voltage Range: ± 12V to 15V
- Secondary Signal Type: 50mA
- Current Sensor Technology: Closed Loop Hall Effect
- Operating Temperature Max: 85°C
- Operating Temperature Min: -40°C
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 19.31 € |
| Current stock | 100+ |
| Lead time | 30 days |
## **Current Transducer LA 100-TP** ## _I_ **= 100 A** P N For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. |~~**Electrical data**~~<br>~~a~~|~~**Electrical data**~~<br>~~a~~|~~**Electrical data**~~<br>~~a~~|~~**Electrical data**~~<br>~~a~~|~~**Electrical data**~~<br>~~a~~|~~**Electrical data**~~<br>~~a~~|~~**Electrical data**~~<br>~~a~~| |---|---|---|---|---|---|---| |_I_P N<br>_I_P M|Primary nominal RMS current<br>Primary current, measuring range|||100<br>0 ... ±150|0 ... ±150|A<br>A| |_R_M|Measuring resistance @|Measuring resistance @|_T_A= 70 °C<br>_T_A= 85 °C|||| ||||_R_M min _R_M max<br>_R_M min||_R_M max|| ||with ±12 V|@ ±100 Amax|0|0<br>50<br>0|42|Ω| |||@ ±120 Amax|0|0<br>22<br>0|14|Ω| ||with ±15 V|@ ±100 Amax|0|0<br>110<br>20|102|Ω| |_I_S N|@ ±150 Amax<br>Secondary nominal RMS current||0|0<br>33<br>20<br>50|25|Ω<br>mA| |_N_P/_N_STurns ratio<br>_U_C<br>Supply voltage (±5 %)||Supply voltage (±5 %)||1 : 2000<br>±12 ... 15<br>Min<br>Typ|±12 ... 15<br>Max|V| |_I_C|Current consumption|Current consumption<br>@ ±15 V||8+_I_S10+_I_S|12+_I_S|mA| ## ~~**Accuracy - Dynamic performance data** Lo~~ _ε_ Error @ _I_ P N, _T_ A = 25 °C @ ±15 V (±5 %) ±0.45 % @ ±12 ... 15 V (±5 %) ±0.70 % _ε_ L Linearity error < 0.15 % Typ Max _I_ O E Electrical offset current @ _I_ P = 0, _T_ A = 25 °C ±0.10 mA _I_ O M Magnetic offset current[1)] @ _I_ P = 0 and specified _R_ M, after an overload of 3 × _I_ P N ±0.15 mA _I_ O _T_ Temperature variation of _I_ O −25 °C ... +85 °C ±0.05 ±0.30 mA −40 °C ... −25 °C ±0.10 ±0.50 mA _t_ D 10 Delay time to 10 % of the final output value for _I_ P N step < 500 ns _t_ D 90 Delay time to 90 % of the final output value for _I_ P N step 2) < 1 µs _BW_ Frequency bandwidth (−1 dB) DC ... 200 kHz |~~**General data**~~<br>~~Lo~~|~~**General data**~~<br>~~Lo~~|~~**General data**~~<br>~~Lo~~|~~**General data**~~<br>~~Lo~~|~~**General data**~~<br>~~Lo~~| |---|---|---|---|---| |_T_A|Ambient operating temperature||−40 ... +85|°C| |_T_A st<br>_R_S|Ambient storage temperature<br>Resistance of secondary winding|@_T_A= 70 °C|−40 ... +90<br>120|°C<br>Ω| |_m_|Mass|@_T_A= 85 °C|128<br>24|Ω<br>g| ||Standards||EN 50178: 1997|| ||||UL 508: 2010|| ## **Features** - ●Closed loop (compensated) current transducer using the Hall effect - ●Insulating plastic case recognized according to UL 94-V0. ## **Advantages** - ●Excellent accuracy - ●Very good linearity - ●Low temperature drift - ●Optimized response time - ●Wide frequency bandwidth - ●No insertion losses - ●High immunity to external interference - ●Current overload capability. ## **Applications** - ●AC variable speed drives and servo motor drives - ●Static converters for DC motor drives - ●Battery supplied applications - ●Uninterruptible Power Supplies (UPS) - ●Switched Mode Power Supplies (SMPS) - ●Power supplies for welding applications. ## **Application domain** - ●Industrial. Notes:[1)] Result of the coercive field of the magnetic circuit > 2) For a d _i_ /d _t_ = 100 A/µs. N° 97.10.34.000.0 Page 1/3 LEM International SA Route du Nant-d’Avril, 152 1217 Meyrin www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them. 6July2023/Version 13 ## **Current Transducer LA 100-TP** ## ~~**Insulation coordination**~~ |_U_d|RMS voltage for AC insulation test, 50 Hz/1 min|2.5|kV| |---|---|---|---| |_U_Ni|Impulse withstand voltage 1.2/50 µs|7.5|kV| |||Min|| |_d_Cp|Creepage distance|8.3|mm| |_d_CI|Clearance|8.3|mm| |_CTI_|Comparative tracking index (group I)|600|| ## **Applications examples** According to **EN 50178 and IEC 61010-1 standards** and following conditions: - ●Over voltage category OV 3 - ●Pollution degree PD2 - ●Non-uniform field ||**EN 50178**|**IEC 61010-1**| |---|---|---| |_d_Cp,_d_CI,_U_Ni|Rated insulation voltage|Nominal voltage| |Basic insulation|1000 V|1000 V| |Reinforced insulation|600 V|300 V| ## **Safety** This transducer must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. ## Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 LEM International SA Route du Nant-d’Avril, 152 1217 Meyrin www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them. 6July2023/Version 13 ## **Dimensions LA 100-TP** (in mm) **==> picture [512 x 323] intentionally omitted <==** **----- Start of picture text -----**<br> d Cl d Cp<br>Connection<br>I P<br>I S R M<br>U C<br>U C<br>**----- End of picture text -----**<br> ## **Mechanical characteristics** - ●General tolerance ±0.2 mm busbar ●Fastening & connection of primary busbar 6.4 × 1.6 mm Recommended PCB hole 3.8 mm ●Fastening & connection of secondary 3 pins 0.6 × 0.7 mm Recommended PCB hole ⌀ 1.2 mm Recommended PCB hole ## **Remarks** - _I_ S is positive when _I_ P flows in the direction of the arrow. - ●Temperature of the primary conductor should not exceed 100 °C. - ●Installation of the transducer must be done unless otherwise specified on the datasheet, according to LEM Transducer Generic Mounting Rules. Please refer to LEM document N°ANE120504 available on our Web site: **https://www.lem.com/en/file/3137/download.** - ●This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. Page 3/3 LEM International SA Route du Nant-d’Avril, 152 1217 Meyrin www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them. 6July2023/Version 13
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →