Image not available
Illustrative purposes only
LA 100-P
Current Transducer, LA Series, 10A, -150A to 150A, 0.7 %, Closed Loop Output, 12 Vdc to 15 Vdc
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- Sensor Output:Closed Loop; Supply Voltage DC Min:12V; Supply Voltage DC Max:15V; Current Measuring Range DC:-150A to 150A; Current Measuring Range AC:-150A to 150A; Response Time:-; Accurac
- SVHC: No SVHC (25-Jun-2025)
- Accuracy: 0.45%
- Accuracy %: 0.7%
- Product Range: LA100P Series
- Primary Current: 100A
- Sensor Mounting: Through Hole
- Measured Current: AC / DC / Pulsed
- Sensor Output Type: Closed Loop
- Supply Voltage Range: ± 12V to ± 15V
- Secondary Signal Type: 50V
- Supply Voltage DC Max: 15V
- Supply Voltage DC Min: 12V
- Current Sensor Technology: Closed Loop, Hall Effect
- Operating Temperature Max: 85°C
- Operating Temperature Min: -40°C
- Current Measuring Range AC: -150A to 150A
- Current Measuring Range DC: -150A to 150A
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 28.75 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Current Transducer LA 100-P** For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. ## . C€ fs dus RZHS ## ~~**Electrical data** PO~~ |_I_P N<br>_I_P M|Primary nominal RMS current<br>Primary current, measuring range||100<br>0 ... ±150|100<br>0 ... ±150|100<br>0 ... ±150|A<br>A| |---|---|---|---|---|---|---| |_R_M|Measuring resistance @|_T_A= 70 °C|||_T_A= 85 °C|| |||_R_M min _R_M max|||_R_M min _R_M max|| ||with ±12 V<br>@ ±100 Amax|0|50||0<br>42|Ω| ||@ ±120 Amax|0|22||0<br>14|Ω| ||with ±15 V<br>@ ±100 Amax|0|110||20<br>102|Ω| |_I_S N|@ ±150 Amax<br>Secondary nominal RMS current|0|33<br>50|50|20<br>25|Ω<br>mA| |_N_P/_N_STurns ratio<br>_U_C<br>_I_C|Turns ratio<br>Supply voltage (±5 %)<br>Current consumption (±2)||1 : 2000<br>±12 … 15<br>10(@ ±15 V) +_I_SmA|||V<br>mA| ## ~~**Accuracy - Dynamic performance data** Po~~ _ε_ Error @ _I_ P N, _T_ A = 25 °C @ ±15 V (±5 %) ±0.45 % @ ±12 … 15 V (±5 %) ±0.70 % _ε_ L Linearity error < 0.15 % Typ Max _I_ O Offset current @ _I_ P = 0, _T_ A = 25 °C ±0.10 mA _I_ O M Magnetic offset current[1)] @ _I_ P = 0 and specified _R_ M, after an overload of 3 × _I_ P N ±0.15 mA _I_ O _T_ Temperature variation of _I_ O −25 °C … +85 °C ±0.05 ±0.30 mA −40 °C … −25 °C ±0.10 ±0.50 mA _t_ D 10 Delay time @ 10 % of _I_ P N < 500 ns _t_ D 90 Delay time to 90 % of _I_ P N 2) < 1 µs _BW_ Frequency bandwidth (−1 dB) DC … 200 kHz ~~**General data** Po~~ |_T_A<br>_T_S<br>_R_S|Ambient operating temperature<br>Ambient storage temperature<br>Resistance of secondary winding|@_T_A= 70 °C|−40 … +85<br>−40 … +90<br>120|°C<br>°C<br>Ω| |---|---|---|---|---| |_m_|Mass|@_T_A= 85 °C|128<br>18|Ω<br>g| ||Standards||EN 50178: 1997|| ||||UL 508: 2010|| ## _I_ **= 100 A** P N ## **Features** - ●Closed loop (compensated) current transducer using the Hall effect - ●Insulated plastic case recognized according to UL 94-V0. ## **Advantages** - ●Excellent accuracy - ●Very good linearity - ●Low temperature drift - ●Optimized response time - ●Wide frequency bandwidth - ●No insertion losses - ●High immunity to external interference - ●Current overload capability. ## **Applications** - ●AC variable speed drives and servo motor drives - ●Static converters for DC motor drives - ●Battery supplied applications - ●Uninterruptible Power Supplies (UPS) - ●Switched Mode Power Supplies (SMPS) - ●Power supplies for welding applications. ## **Application domain** - ●Industrial. Notes:[1)] Result of the coercive field of the magnetic circuit > 2) For a d _i_ /d _t_ = 100 A/µs. N° 97.09.34.000.0 Page 1/3 LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 15November2018/version 13 ## **Current Transducer LA 100-P** ## ~~**Insulation coordination**~~ |_U_d|RMS voltage for AC insulation test, 50 Hz/1 min|2.5|kV| |---|---|---|---| |_U_Ni|Impulse withstand voltage 1.2/50 µs|4.5|kV| |||Min|| |_d_Cp|Creepage distance|3.8|mm| |_d_CI|Clearance|3.8|mm| |_CTI_|Comparative tracking index (group I)|600|| ## **Applications examples** **According to EN 50178 and IEC 61010-1 standards** and following conditions: - ●Over voltage category OV 3 - ●Pollution degree PD2 - ●Non-uniform field ||**EN 50178**|**IEC 61010-1**| |---|---|---| |_d_Cp,_d_CI,_U_Ni|Rated insulation voltage|Nominal voltage| |Basic insulation|300 V|300 V| |Reinforced insulation|150 V|150 V| ## **Safety** This transducer must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. ## Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 15November2018/version 13 ## **Dimensions LA 100-P** (in mm) **==> picture [511 x 372] intentionally omitted <==** **----- Start of picture text -----**<br> Connection<br>I P<br>I S R M<br>U C<br>U C<br>d Cl d Cp<br>**----- End of picture text -----**<br> ## **Mechan** ~~**ic**~~ **al characteristic** ~~**s**~~ - ●General tolerance - ±0.2 mm ~~12.7 × 7 mm~~ - ●Primary through-hole - ●Fastening & Connection of secondary 3 pins 0.6 × 0.7 mm - ●Recommended PCB hole ⌀ 1.2 mm ## **Remarks** - _I_ S is positive when _I_ P flows in the direction of the arrow. - ●Temperature of the primary c ~~o~~ nduc ~~tor should not ex~~ ceed 100 °C. - ●Dynamic performances ( d _i_ /d _t_ a ~~n~~ d response time) are best with a single bar completely filling t ~~h~~ e primary hole. - Installation of the transducer must be done unless ~~o~~ th ~~e~~ rw ~~ise~~ sp ~~ec~~ i ~~fe~~ d on t ~~h~~ e d ~~a~~ tas ~~heet, accord~~ i ~~ng t~~ o LE ~~M~~ Transducer Generic Mounting R ~~u~~ l ~~e~~ s. Please refer to LEM doc ~~um~~ ent N°ANE ~~1~~ 20504 ~~available on our Web site:~~ **https://www.lem.com/en/file/3137/** ~~**d**~~ **o** ~~**w**~~ **n** ~~**lo**~~ **a** ~~**d/**~~ **.** - ●In order to achieve t ~~h~~ e best magnetic coupl ~~i~~ ng, the primary windings have to be wound over the top edge of the device. - ●This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. Page 3/3 LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 15November2018/version 13
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →