L000306-01
RF Antenna, 4.2 to 6GHz, Cellular / 5G / 4G / LTE / MIMO / IoT, 6.5dBi, Linear, Wall / SMA Connector
- Manufacturer: TE CONNECTIVITY
- Product type:
- Gain: 6.5dBi
- SVHC: Lead (04-Feb-2026)
- VSWR: 2.2
- Input Power: 10W
- Antenna Type: Cellular / 5G / 4G / LTE / MIMO / IoT
- Frequency Max: 6GHz
- Frequency Min: 4.2GHz
- Product Range: RP40 Lite Series
- Input Impedance: 50ohm
- Antenna Mounting: Wall / SMA Connector
- Antenna Polarisation: Linear
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 202.14 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **RP40 lite** ## **5G, 4G/LTE 4x4 MIMO Fixed Wireless Access Omnidirectional Antenna** The RP40 lite (L000306-XX) antenna family from TE Connectivity (TE) provides high-performance connectivity for current and emerging 4G and 5G frequencies in a flexible and modular package. The incorporated 4x4 MIMO technology and consistent radiation patterns means that the RP40 lite can provide enhanced data rates and bandwidth with extremely consistent performance. RP40 lite is suitable for use globally on cellular networks and with any network operator. It fits most common industrial routers/gateways currently on the market. There are 4 or 5-port variants available with the optional fifth port for GNSS coverage. Each model covers 617 - 6000 MHz and supports all major global 5G and 4G/LTE bands. Designed with a stylish housing and includes all the necessary mounting hardware for desk, wall, offset wall and pole mounting options. ## FEATURES AND BENEFITS ## APPLICATIONS - Global LTE and 5G coverage (617-6000MHz) - Consistent omnidirectional patterns across all bands, providing stable reception - Extensive mechanical and environmental testing including UV, flammability, humidity, impact, vibration, shock (see page 3 for full details) - Primary connectivity - Fixed Wireless Access (FWA) - Failover support - IoT device connections - Private networks - Integrated 5m (16ft) cables for easier installation - Supplied with all brackets and mounting hardware ## **APPLICATIONS** ## **Remote Offices** ## **Hotel Rooms** ## **Construction Sites** ## **Remote Schools** **Rural Communities** **Temporary Usage** DATA AND DEVICES / RP40 LITE - L000306-XX ## SPECIFICATIONS |ELECTRICAL SPECIFICATION|ELECTRICAL SPECIFICATION|ELECTRICAL SPECIFICATION|ELECTRICAL SPECIFICATION|ELECTRICAL SPECIFICATION|ELECTRICAL SPECIFICATION|ELECTRICAL SPECIFICATION| |---|---|---|---|---|---|---| |Operating Frequency (MHz)|617-698|698-960|1427-1496|1559-1606|1690-4200|4200-6000| |VSWR - Max|<2.20||<2.20|||| |Isolation - Min (dB)*|10|||||| |Peak Gain - Max (dBi)*|5.2||6.5|||| |Total Effciency Average (%)|77|||||| |Nominal Impedance (Ohms)|50|||||| |Max Power - Ambient 25°C (W)|10|||||| |Polarization|Linear Dual Polarized (2V x 2H)|||||| |Azimuth Beamwidth|360°, Omnidirectional|||||| *Measured with 1.5ft LMR195 equivalent coaxial cable ## ELECTRICAL SPECIFICATION - GNSS |ELECTRICAL SPECIFICATION - GNSS|ELECTRICAL SPECIFICATION - GNSS|ELECTRICAL SPECIFICATION - GNSS|ELECTRICAL SPECIFICATION - GNSS| |---|---|---|---| |Operating Frequency (MHz)|1561.098±2.046|1575.42±1.023|1602±5| |VSWR - Max|<2.0||| |LNA Gain, dB|28±3||| |LNA Noise Figure, dB|3.17|2.87|3.06| |LNA Input Max. Power, dBm|-10||| |Out of band Rejection (dBc)|698-960MHz|>80|| ||1428-1511MHz|>80|| ||1710-2700MHz|>80|| ||4900-5800MHz|>70|| |DC Voltage, V|2.5-7.0||| |Current, mA|8.5±3 (at 3.0V)||| |Nominal Impedance|50||| |Polarization|RHCP||| ## MECHANICAL SPECIFICATION |MECHANICAL SPECIFICATION|MECHANICAL SPECIFICATION| |---|---| |Dimensions – Length x Width x Height – mm (in.)|380 x 230 x 30 mm (14.96 x 9.05 x 1.18)| |Weight kg (lbs.)|L000306-01 - 1.3 (2.87)<br>L000306-02 - 1.5 (3.31)| |Cable|Cellular: LMR 195-equivalant<br>GNSS: RG174| |Radome Color / Material|White FRPC2100 UV| |Base Material|PC-ABS FR-V0, UV| |Mounting|Multiple Options Supplied| DATA AND DEVICES / RP40 LITE - L000306-XX 2 |ENVIRONMENTAL SPECIFICATION|ENVIRONMENTAL SPECIFICATION| |---|---| |Operating Temp. (°C)|-40 to +85| |Storage Temperature (°C)|-40 to +85| |Temperature Cycling|IEC 68-2-14| |Ingress Protection (IP Rating)|IP66| |Humidity|MIL-STD-810G, 507.5, Procedure II, Aggravated Humidity| |Thermal Shock|IEC 68-2-14: -25°C to +70°C| |Corrosive Atmosphere (Salt Fog/Mist)|MIL-STD-810G, Method 509.5| |Vibration|IEC 60068-2-64| |Mechanical Shock|IEC 60068-2-27| |Wind Operational|Simulated 100MPH| |Wind Survival|Simulated 136MPH| |Pull Test|20lb Pull on Connector/Cables: Duration of 30 Seconds| |UV Resistance|ASTM-G-155| |Flammability Rating|UL94-V0| |Material Substance Compliance|RoHS Compliant, CE & UKCA Compliant<br>California Prop 65 Compliant, European RED Compliant| ## PART NUMBER CONFIGURATIONS |PART NUMBER|PIGTAIL/CABLE|CONNECTOR|NUMBER<br>PORTS|FREQUENCY| |---|---|---|---|---| |L000306-01|Integrated Cable - 5m (16ft.)|4 x SMA Male|4|Cellular: 617-6000 MHz| |L000306-02|Integrated Cable - 5m (16ft.)|5 x SMA Male|5|Cellular: 617-6000 MHz<br>GNSS: 1561 - 1602 MHz| ## MOUNTING OPTIONS (MOUNTING KITS INCLUDED) ## **Desk Mount** ## **Direct Wall Mount** ## **Pole Mount** ## **Offset Wall Mount** DATA AND DEVICES / RP40 LITE - L000306-XX 3 ## MECHANICAL DRAWINGS ## MOUNTING OPTION DRAWINGS **==> picture [218 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> Desk Mount Direct Wall Mount<br>**----- End of picture text -----**<br> ## **Offset Wall Mount** ## **Pole Mount** DATA AND DEVICES / RP40 LITE - L000306-XX 4 ## GLOBAL 4G/5G CELLULAR COVERAGE The RP40 lite antenna provides global sub-6 GHz cellular coverage. The table below shows the frequencies and bands covered and the corresponding performance across those bands is shown in the charts below. |FREQUENCY|RF BANDS COVERED| |---|---| |617-960 MHz|5, 6, 8, 12, 13, 14, 17, 18, 19, 20, 26, 27, 28, 29, 44, 67, 68, 71, 85<br>N5, N8, N12, N14, N18, N20, N28, N29, N71, N81, N82, N83, N89, N91, N92, N93,<br>N94, N100| |1427-1690 MHz|11, 21, 24, 32, 45, 74, 75, 76<br>N50, N51, N74, N75, N76| |1690-2700 MHz|1, 2, 3, 4, 7, 9, 10, 15, 16, 23, 25, 30, 33, 34, 35, 36, 37, 38, 39, 40, 41, 65, 66, 69, 70<br>N30, N34, N38, N39, N40, N41, N65, N66, N70, N80, N84, N86, N90, N95, N101| |3300-6000 MHz|22, 42, 43, 46, 47, 48<br>N48, N77, N78, N79| ## LTE - VSWR **==> picture [506 x 251] intentionally omitted <==** **----- Start of picture text -----**<br> L000306-01 Without GNSS<br>4.00<br>3.50<br>3.00<br>2.50<br>2.00<br>1.50<br>1.00<br>500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500<br>Port_1 Port_2 Port_3 Port_4<br>**----- End of picture text -----**<br> DATA AND DEVICES / RP40 LITE - L000306-XX 5 ## LTE - ISOLATION **==> picture [506 x 259] intentionally omitted <==** **----- Start of picture text -----**<br> Isolation (dB)<br>0.00<br>-10.00<br>-20.00<br>-30.00<br>-40.00<br>-50.00<br>-60.00<br>-70.00<br>500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500<br>Port 2 - Port 1 Port 3 - Port 1 Port 4 - Port 1<br>Port 3 - Port 2 Port 4 - Port 2 Port 4 - Port 3<br>**----- End of picture text -----**<br> ## LTE - EFFICIENCY ## **Efficiency (%)** **==> picture [508 x 249] intentionally omitted <==** **----- Start of picture text -----**<br> 100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000<br> Port 1 Eff Port 2 Eff Port 3 Eff Port 4 Eff<br>**----- End of picture text -----**<br> DATA AND DEVICES / RP40 LITE - L000306-XX 6 ## LTE - PEAK GAIN ## **Peak Gain (dBi)** **==> picture [505 x 249] intentionally omitted <==** **----- Start of picture text -----**<br> 7.00<br>6.00<br>5.00<br>4.00<br>3.00<br>2.00<br>1.00<br>0.00<br>500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000<br> Port 1 Gain Port 2 Gain Port 3 Gain Port 4 Gain<br>**----- End of picture text -----**<br> ## RADIATION PATTERNS ## **633 MHz** **==> picture [563 x 223] intentionally omitted <==** **----- Start of picture text -----**<br> Azimuth Plane Phi 0° Plane Phi 90° Plane<br>90 0 0<br>5 5 5<br>120 0 60 330 0 30 330 0 30<br>-5 -5 -5<br>-10 -10 -10<br>150 -15 30 300 -15 60 300 -15 60<br>-20 -20 -20<br>-25 -25 -25<br>-30 -30 -30<br>180 -35 0 270 -35 90 270 -35 90<br>210 330 240 120 240 120<br>240 300 210 150 210 150<br>270 180 180<br>Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4<br>**----- End of picture text -----**<br> DATA AND DEVICES / RP40 LITE - L000306-XX 7 **==> picture [561 x 221] intentionally omitted <==** **----- Start of picture text -----**<br> 725 MHz<br>Azimuth Plane Phi 0° Plane Phi 90° Plane<br>90 0 0<br>5 5 5<br>120 0 60 330 0 30 330 0 30<br>-5 -5 -5<br>-10 -10 -10<br>150 -15 30 300 -15 60 300 -15 60<br>-20 -20 -20<br>-25 -25 -25<br>-30 -30 -30<br>180 -35 0 270 -35 90 270 -35 90<br>210 330 240 120 240 120<br>240 300 210 150 210 150<br>270 180 180<br>Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4<br>**----- End of picture text -----**<br> **==> picture [563 x 223] intentionally omitted <==** **----- Start of picture text -----**<br> 850 MHz<br>Azimuth Plane Phi 0° Plane Phi 90° Plane<br>90 0 0<br>5 5 5<br>120 0 60 330 0 30 330 0 30<br>-5 -5 -5<br>-10 -10 -10<br>150 -15 30 300 -15 60 300 -15 60<br>-20 -20 -20<br>-25 -25 -25<br>-30 -30 -30<br>180 -35 0 270 -35 90 270 -35 90<br>210 330 240 120 240 120<br>240 300 210 150 210 150<br>270 180 180<br>Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4<br>**----- End of picture text -----**<br> **==> picture [561 x 221] intentionally omitted <==** **----- Start of picture text -----**<br> 925 MHz<br>Azimuth Plane Phi 0° Plane Phi 90° Plane<br>90 0 0<br>5 5 5<br>120 0 60 330 0 30 330 0 30<br>-5 -5 -5<br>-10 -10 -10<br>150 -15 30 300 -15 60 300 -15 60<br>-20 -20 -20<br>-25 -25 -25<br>-30 -30 -30<br>180 -35 0 270 -35 90 270 -35 90<br>210 330 240 120 240 120<br>240 300 210 150 210 150<br>270 180 180<br>Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4<br>**----- End of picture text -----**<br> DATA AND DEVICES / RP40 LITE - L000306-XX 8 ## **1448 MHz** **==> picture [561 x 221] intentionally omitted <==** **----- Start of picture text -----**<br> 1448 MHz<br>Azimuth Plane Phi 0° Plane Phi 90° Plane<br>90 0 0<br>5<br>120 0 60 330 5 30 330 5 30<br>-5<br>-10 -5 -5<br>150 -15 30 300 60 300 60<br>-15 -15<br>-20<br>-25 -25 -25<br>-30<br>180 -35 0 270 -35 90 270 -35 90<br>210 330 240 120 240 120<br>240 300 210 150 210 150<br>270 180 180<br>Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4<br>**----- End of picture text -----**<br> **==> picture [563 x 223] intentionally omitted <==** **----- Start of picture text -----**<br> 1730 MHz<br>Azimuth Plane Phi 0° Plane Phi 90° Plane<br>90 0 0<br>5 5 5<br>120 0 60 330 0 30 330 0 30<br>-5 -5 -5<br>-10 -10 -10<br>150 -15 30 300 -15 60 300 -15 60<br>-20 -20 -20<br>-25 -25 -25<br>-30 -30 -30<br>180 -35 0 270 -35 90 270 -35 90<br>210 330 240 120 240 120<br>240 300 210 150 210 150<br>270 180 180<br>Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4<br>**----- End of picture text -----**<br> **==> picture [561 x 221] intentionally omitted <==** **----- Start of picture text -----**<br> 1930 MHz<br>Azimuth Plane Phi 0° Plane Phi 90° Plane<br>90 0 0<br>5<br>120 0 60 330 5 30 330 5 30<br>-5<br>-10 -5 -5<br>150 -15 30 300 60 300 60<br>-15 -15<br>-20<br>-25 -25 -25<br>-30<br>180 -35 0 270 -35 90 270 -35 90<br>210 330 240 120 240 120<br>240 300 210 150 210 150<br>270 180 180<br>Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4<br>**----- End of picture text -----**<br> DATA AND DEVICES / RP40 LITE - L000306-XX 9 **==> picture [562 x 223] intentionally omitted <==** **----- Start of picture text -----**<br> 2130 MHz<br>Azimuth Plane Phi 0° Plane Phi 90° Plane<br>90 0 0<br>5 5 5<br>120 0 60 330 0 30 330 0 30<br>-5 -5 -5<br>-10 -10 -10<br>150 -15 30 300 -15 60 300 -15 60<br>-20 -20 -20<br>-25 -25 -25<br>-30 -30 -30<br>180 -35 0 270 -35 90 270 -35 90<br>210 330 240 120 240 120<br>240 300 210 150 210 150<br>270 180 180<br>Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4<br>**----- End of picture text -----**<br> **==> picture [560 x 220] intentionally omitted <==** **----- Start of picture text -----**<br> 2310 MHz<br>Azimuth Plane Phi 0° Plane Phi 90° Plane<br>90 0 0<br>5<br>120 0 60 330 5 30 330 5 30<br>-5<br>-10 -5 -5<br>150 -15 30 300 60 300 60<br>-15 -15<br>-20<br>-25 -25 -25<br>-30<br>180 -35 0 270 -35 90 270 -35 90<br>210 330 240 120 240 120<br>240 300 210 150 210 150<br>270 180 180<br>Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4<br>**----- End of picture text -----**<br> **==> picture [563 x 222] intentionally omitted <==** **----- Start of picture text -----**<br> 2600 MHz<br>Azimuth Plane Phi 0° Plane Phi 90° Plane<br>90 0 0<br>5 5 5<br>120 0 60 330 0 30 330 0 30<br>-5 -5 -5<br>-10 -10 -10<br>150 -15 30 300 -15 60 300 -15 60<br>-20 -20 -20<br>-25 -25 -25<br>-30 -30 -30<br>180 -35 0 270 -35 90 270 -35 90<br>210 330 240 120 240 120<br>240 300 210 150 210 150<br>270 180 180<br>Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4<br>**----- End of picture text -----**<br> DATA AND DEVICES / RP40 LITE - L000306-XX 10 ## **2700 MHz** **==> picture [562 x 222] intentionally omitted <==** **----- Start of picture text -----**<br> 2700 MHz<br>Azimuth Plane Phi 0° Plane Phi 90° Plane<br>90 0 0<br>5 5 5<br>120 0 60 330 0 30 330 0 30<br>-5 -5 -5<br>-10 -10 -10<br>150 -15 30 300 -15 60 300 -15 60<br>-20 -20 -20<br>-25 -25 -25<br>-30 -30 -30<br>180 -35 0 270 -35 90 270 -35 90<br>210 330 240 120 240 120<br>240 300 210 150 210 150<br>270 180 180<br>Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4<br>**----- End of picture text -----**<br> ## **3300 MHz** **==> picture [561 x 221] intentionally omitted <==** **----- Start of picture text -----**<br> 3300 MHz<br>Azimuth Plane Phi 0° Plane Phi 90° Plane<br>90 0 0<br>5<br>120 0 60 330 5 30 330 5 30<br>-5<br>-10 -5 -5<br>150 -15 30 300 60 300 60<br>-15 -15<br>-20<br>-25 -25 -25<br>-30<br>180 -35 0 270 -35 90 270 -35 90<br>210 330 240 120 240 120<br>240 300 210 150 210 150<br>270 180 180<br>Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4<br>**----- End of picture text -----**<br> **==> picture [563 x 223] intentionally omitted <==** **----- Start of picture text -----**<br> 3500 MHz<br>Azimuth Plane Phi 0° Plane Phi 90° Plane<br>90 0 0<br>5 5 5<br>120 0 60 330 0 30 330 0 30<br>-5 -5 -5<br>-10 -10 -10<br>150 -15 30 300 -15 60 300 -15 60<br>-20 -20 -20<br>-25 -25 -25<br>-30 -30 -30<br>180 -35 0 270 -35 90 270 -35 90<br>210 330 240 120 240 120<br>240 300 210 150 210 150<br>270 180 180<br>Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4<br>**----- End of picture text -----**<br> DATA AND DEVICES / RP40 LITE - L000306-XX 11 ## **3700 MHz** **==> picture [562 x 222] intentionally omitted <==** **----- Start of picture text -----**<br> 3700 MHz<br>Azimuth Plane Phi 0° Plane Phi 90° Plane<br>90 0 0<br>5 5 5<br>120 0 60 330 0 30 330 0 30<br>-5 -5 -5<br>-10 -10 -10<br>150 -15 30 300 -15 60 300 -15 60<br>-20 -20 -20<br>-25 -25 -25<br>-30 -30 -30<br>180 -35 0 270 -35 90 270 -35 90<br>210 330 240 120 240 120<br>240 300 210 150 210 150<br>270 180 180<br>Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4<br>4200 MHz<br>**----- End of picture text -----**<br> **==> picture [562 x 223] intentionally omitted <==** **----- Start of picture text -----**<br> 4200 MHz<br>Azimuth Plane Phi 0° Plane Phi 90° Plane<br>90 0 0<br>5 5 5<br>120 0 60 330 0 30 330 0 30<br>-5 -5 -5<br>-10 -10 -10<br>150 -15 30 300 -15 60 300 -15 60<br>-20 -20 -20<br>-25 -25 -25<br>-30 -30 -30<br>180 -35 0 270 -35 90 270 -35 90<br>210 330 240 120 240 120<br>240 300 210 150 210 150<br>270 180 180<br>Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4<br>5150 MHz<br>**----- End of picture text -----**<br> **==> picture [563 x 223] intentionally omitted <==** **----- Start of picture text -----**<br> 5150 MHz<br>Azimuth Plane Phi 0° Plane Phi 90° Plane<br>90 0 0<br>5 5 5<br>120 0 60 330 0 30 330 0 30<br>-5 -5 -5<br>-10 -10 -10<br>150 -15 30 300 -15 60 300 -15 60<br>-20 -20 -20<br>-25 -25 -25<br>-30 -30 -30<br>180 -35 0 270 -35 90 270 -35 90<br>210 330 240 120 240 120<br>240 300 210 150 210 150<br>270 180 180<br>Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4<br>**----- End of picture text -----**<br> DATA AND DEVICES / RP40 LITE - L000306-XX 12 ## **5500 MHz** **==> picture [562 x 222] intentionally omitted <==** **----- Start of picture text -----**<br> 5500 MHz<br>Azimuth Plane Phi 0° Plane Phi 90° Plane<br>90 0 0<br>5 5 5<br>120 0 60 330 0 30 330 0 30<br>-5 -5 -5<br>-10 -10 -10<br>150 -15 30 300 -15 60 300 -15 60<br>-20 -20 -20<br>-25 -25 -25<br>-30 -30 -30<br>180 -35 0 270 -35 90 270 -35 90<br>210 330 240 120 240 120<br>240 300 210 150 210 150<br>270 180 180<br>Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4<br>**----- End of picture text -----**<br> **==> picture [563 x 223] intentionally omitted <==** **----- Start of picture text -----**<br> 5800 MHz<br>Azimuth Plane Phi 0° Plane Phi 90° Plane<br>90 0 0<br>5 5 5<br>120 0 60 330 0 30 330 0 30<br>-5 -5 -5<br>-10 -10 -10<br>150 -15 30 300 -15 60 300 -15 60<br>-20 -20 -20<br>-25 -25 -25<br>-30 -30 -30<br>180 -35 0 270 -35 90 270 -35 90<br>210 330 240 120 240 120<br>240 300 210 150 210 150<br>270 180 180<br>Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4<br>6000 MHz<br>**----- End of picture text -----**<br> **==> picture [563 x 223] intentionally omitted <==** **----- Start of picture text -----**<br> 6000 MHz<br>Azimuth Plane Phi 0° Plane Phi 90° Plane<br>90 0 0<br>5 5 5<br>120 0 60 330 0 30 330 0 30<br>-5 -5 -5<br>-10 -10 -10<br>150 -15 30 300 -15 60 300 -15 60<br>-20 -20 -20<br>-25 -25 -25<br>-30 -30 -30<br>180 -35 0 270 -35 90 270 -35 90<br>210 330 240 120 240 120<br>240 300 210 150 210 150<br>270 180 180<br>Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4<br>**----- End of picture text -----**<br> DATA AND DEVICES / RP40 LITE - L000306-XX 13 ## PACKAGING ## Ocean Shipping Standard Configuration Information - Pallet 120cm x 80cm x 14cm, Weight 12 kg - Single unit carton: Weight 2.6 kg - Master carton @ 12 unit: Weight 33.0 kg - Pallet @ 8 master cartons per pallet: Weight 276 kg (120 x 80 x 174cm) 96 total units per pallet ## Air Shipping Standard Configuration Information - Pallet 120cm x 80cm x 14cm, Weight 12kg - Single unit carton: Weight 2.6 kg - Master carton @ 12 unit: Weight 33.0 kg - Pallet @ 6 master cartons per pallet: Weight 163.2kg (120 x 80 x 130.5cm) 72 total units per pallet |PACKAGED DIMENSIONS|UNIT CARTON|MASTER CARTON|AIR PALLET|OCEAN PALLET| |---|---|---|---|---| |Number of Antennas|1|12|72|96| |Height cm (in)|9.0 (3.54)|43.5 (17.13)|144.5 (56.89)|188.4 (74.17)| |Length cm (in)|38.3 (15.08)|60.0 (23.6)|120 (47.24)|120 (47.24)| |Width cm (in)|31.5 (12.4)|66.5 (26.18)|80.0 (31.5)|80 (31.5)| |Est. Shipping Weight* kg (lbs.)<br>*Including Mounting Kits|2.6 (5.8)|33.0 (72.7)|210 (463.0)|276 (608.5)| ## **te.com** ## **TE TECHNICAL SUPPORT CENTER** TE, and TE connectivity (logo) are trademarks owned or licensed by the TE Connectivity Ltd. family of companies. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. USA: +1 (800) 522-6752 and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to Canada: +1 (905) 475-6222 be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard Terms and Conditions of Sale for this product and in Mexico: +52 (0) 55-1106-0800 no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific Latin/S. America: +54 (0) 11-4733-2200 application. Germany: +49 (0) 6251-133-1999 TE Connectivity warrants to the original end user customer of its products that its products are free from defects in material and workmanship. Subject to conditions and limitations TE Connectivity will, at its option, either repair or replace any part of its products that UK: +44 (0) 800-267666 prove defective because of improper workmanship or materials. This limited warranty is in force for the useful lifetime of the original end product into which the TE Connectivity product is installed. Useful lifetime of the original end product may vary but is not warrantied to France: +33 (0) 1-3420-8686 exceed one (1) year from the original date of the end product purchase. Netherlands: +31 (0) 73-6246-999 ©2023 TE Connectivity. All Rights Reserved. **08/23 Original** China: +86 (0) 400-820-6015 DATA AND DEVICES / RP40 LITE - L000306-XX
Updated at June 9, 2026
TE Connectivity is a globally recognized engineering and manufacturing leader, specializing in highly reliable connectivity and sensing solutions. Renowned for innovation and durability, their components are engineered to perform in the most demanding environments, supporting critical advancements in industrial equipment, data communications, and automotive systems. Our extensive selection of TE Connectivity products is anchored by their industry-leading connector portfolio. We carry a comprehensive array of terminal blocks and accessories, including wire-to-board, pluggable, standard, and barrier configurations, alongside robust backplane connectors designed to ensure secure and efficient power and data transmission in complex circuit designs. Beyond physical connections, TE Connectivity is a premier manufacturer of precision sensors, antennas, and electromechanical switching components. Our inventory features a wide variety of RF antennas and highly accurate pressure, temperature, and force transducers. Additionally, we provide an expansive range of TE's dependable relays, encompassing automotive, power, and signal variants, alongside essential passive components like shielding gaskets and RF inductors to fully support your engineering requirements.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →