KT3225-3
CABLE TERMINAL, T3 CIRCUIT BREAKER
- Manufacturer: ABB
- Product type: Circuit Breaker Accessories
- For Use With: Molded Case Circuit Breaker (MCCB)
- Product Range: Tmax KT3 Series
- Accessory Type: Cable Terminal
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 9.44 € |
| Current stock | 10+ |
| Lead time | 30 days |
Tmax Molded Case Circuit Breakers ## **Molded Case Circuit Breakers** Index ## **Tmax Molded Case Circuit Breakers** T1…T8 General information ............................................................................................1 T1…T8 Selection information ..........................................................................................2 T1…T8 Catalogue number explanation ...........................................................................4 T1 100A .........................................................................................................................5 T2 100A .........................................................................................................................7 T3 225A .......................................................................................................................10 Ts3 225A ......................................................................................................................13 T4 250A .......................................................................................................................17 T5 400A / 600A ............................................................................................................23 T6 600A / 800A ............................................................................................................28 T7-T7M 1000A /1200A ................................................................................................31 T8V 1600A / 2000A / 2500A / 3000A ...........................................................................41 T1…T6 Accessories .....................................................................................................47 T1…T2 Dimensions ......................................................................................................61 T3 Dimensions ..............................................................................................................62 Ts3 Dimensions ............................................................................................................63 T4 Dimensions ..............................................................................................................64 T5 Dimensions ..............................................................................................................65 T6 Dimensions ..............................................................................................................66 T7 Dimensions ..............................................................................................................67 T8 Dimensions ..............................................................................................................68 T1...T7 Variable depth handle dimensions................................... ..................................71 ## **Molded Case Circuit Breakers** Index ## **Tmax Molded Case Circuit Breakers** T1…T8 General information ............................................................................................1 T1…T8 Selection information ..........................................................................................2 T1…T8 Catalogue number explanation ...........................................................................4 T1 100A .........................................................................................................................5 T2 100A .........................................................................................................................7 T3 225A .......................................................................................................................10 Ts3 225A ......................................................................................................................13 T4 250A .......................................................................................................................17 T5 400A / 600A ............................................................................................................23 T6 600A / 800A ............................................................................................................28 T7-T7M 1000A /1200A ................................................................................................31 T8V 1600A / 2000A / 2500A / 3000A ...........................................................................41 T1…T6 Accessories .....................................................................................................47 T1…T2 Dimensions ......................................................................................................61 T3 Dimensions ..............................................................................................................62 Ts3 Dimensions ............................................................................................................63 T4 Dimensions ..............................................................................................................64 T5 Dimensions ..............................................................................................................65 T6 Dimensions ..............................................................................................................66 T7 Dimensions ..............................................................................................................67 T8 Dimensions ..............................................................................................................68 T1...T7 Variable depth handle dimensions................................... ..................................71 ## **Tmax** Molded Case Circuit Breakers ## **Introduction** ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high performance, versatility and standardization in a range of molded case circuit breakers. The ABB Tmax line of circuit breakers, with a range up to 3000A, has several key features that go along with its very small size: - Double insulation – this construction characteristic allows for the CSA/ UL listed fi eld installation of internal accessories without exposure to energized parts - Complete range of electrical and mechanical accessories - Positive operation – breakers from ABB ensure that the toggle indicates the precise position of the moving contacts. This guarantees safe and reliable signaling by the device - Installation – Tmax molded case circuit breakers can be installed in panels and switchboards in either the horizontal or vertical planes while being fed from either end without any derating of their performance characteristics - Interrupting ratings at 600VAC up to 100kAIC - All versions of the Tmax family are suitable for reverse feed applications The ABB Tmax series includes eight basic frame sizes as well as the T1 single pole with the range rated from 15A to 3000A at 600VAC. ## **Frame Sizes** — Eight Basic Sizes The ABB Tmax series includes eight basic frame sizes as well as the T1 single pole with the range rated from 15A to 3000A at 600VAC. The various versions carry the following interrupting capacities: - **B** Basic breaking capacity - **N** Normal breaking capacity - **S** Standard breaking capacity - **H** High breaking capacity - **L** Extra high breaking capacity - **V** Very high breaking capacity ## **Derived Versions** - Thermal magnetic - Electronic - Molded case switches - Motor circuit protectors (MCPs) - Direct current (DC) rated ## **ABB Tmax Versions** - Fixed: all models - Drawout or plug-in: T2, T3, Ts3, T4, T5, T6 and T7 - UL File #E93565 (breakers and MCPs) #E116596 (Accessories) #E116595 (Molded case switches) - Compact size - All Tmax molded case circuit breakers are CSA-UL listed and IEC rated for global application and acceptance ABB 1 AC1615S - 03/10 ## **Tmax** ## **Selection Guide** Circuit Breakers for Power Distribution T1 – Ts3 |**Type**|**Tmax T1 1p**|**Tmax T1**|**Tmax T2**|**Tmax T3**|**Tmax Ts3**|**Tmax Ts3**| |---|---|---|---|---|---|---| |Frame size<br>[A]<br>Number of poles<br>[Nr]<br>Rated voltage AC (50-60Hz)<br>[V]<br>DC<br>[V]<br>Interrupting<br>ratings<br>240V AC<br>[kA rms]<br>277V AC<br>[kA rms]<br>347V AC<br>[kA rms]<br>480V AC<br>[kA rms]<br>600Y/347V AC<br>[kA rms]<br>600V AC<br>[kA rms]<br>250V DC (2 poles in series)<br>[kA rms]<br>500V DC (3 poles in series)<br>[kA rms]<br>500V DC (2 poles in series)<br>[kA rms]<br>600V DC (3 poles in series)<br>[kA rms]<br>Trip units<br>TMF<br>TMD/TMA<br>MA<br>Electronic<br>Dimensions<br>H<br>[in/mm]<br>W 3p<br>[in/mm]<br>D<br>[in/mm]<br>Mechanical life<br>[No. operations]|100<br>1<br>347<br>B<br>18(1)<br>14(1)<br>**•**<br>5.12/130<br>1/25.4<br>2.76/70<br>25000|100<br>3-4<br>600Y/347<br>500<br>N<br>50(2)<br>22(2)<br>10<br>25<br>25<br>**•**<br>5.12/130<br>3/76<br>2.76/70<br>25000|100<br>3-4<br>480<br>S<br>H<br>65<br>100<br>35<br>65<br>**•**<br>**•**<br>**•**<br>5.12/130<br>3.54/90<br>2.76/70<br>25000|225<br>3-4<br>600Y/347<br>500<br>N<br>S<br>50<br>65<br>25<br>35<br>10<br>10<br>25<br>35<br>25<br>35<br>**•**<br>**•**<br>5.9/150<br>4.13/105<br>2.76/70<br>25000|150<br>2-3-4<br>600<br>600<br>N<br>H<br>L<br>65<br>100<br>150<br>25<br>50<br>85(3)<br>14<br>14<br>25<br>35<br>50<br>65<br>20<br>35<br>50<br>**•**<br>**•**<br>6.7/170<br>4.13/105<br>4.07/103.5<br>25000|225<br>2-3-4<br>480<br>500<br>N<br>H<br>L<br>65<br>100<br>150<br>25<br>50<br>65<br>20<br>35<br>50<br>**•**<br>**•**<br>6.7/170<br>4.13/105<br>4.07/103.5<br>25000| > (1) In15A = 10kA@277VAC 10kA@347VAC > (2) In15A = 35kA@240VAC 14kA@480Y/277 VAC > (3) In from 15A up to 30A=65kA@480V AC 2 ABB AC1615S - 03/10 **Tmax** ## **Selection Guide** Circuit Breakers for Power Distribution T4 – T8 |**Type**|**Tmax T4**|**Tmax T5**|**Tmax T6**|**Tmax T7**|**Insulated Case**<br>**T8**| |---|---|---|---|---|---| |Frame size<br>[A]<br>Number of poles<br>[Nr]<br>Rated voltage AC (50-60Hz)<br>[V]<br>DC<br>[V]<br>Interrupting<br>ratings<br>240V AC<br>[kA rms]<br>277V AC<br>[kA rms]<br>347V AC<br>[kA rms]<br>480V AC<br>[kA rms]<br>600Y/347V AC<br>[kA rms]<br>600V AC<br>[kA rms]<br>250V DC (2 poles in series)<br>[kA rms]<br>500V DC (3 poles in series)<br>[kA rms]<br>500V DC (2 poles in series)<br>[kA rms]<br>600V DC (3 poles in series)<br>[kA rms]<br>Trip units<br>TMF<br>TMD/TMA<br>MA<br>Electronic<br>Dimensions<br>H<br>[in/mm]<br>W 3p<br>[in/mm]<br>D<br>[in/mm]<br>Mechanical life<br>[No. operations]|250<br>2-3-4(4)<br>600<br>600<br>N<br>S<br>H<br>L<br>V<br>65<br>100 150 200 200<br>25<br>35<br>65<br>100 150<br>18<br>25<br>35<br>65<br>100<br>25<br>35<br>50<br>65<br>100<br>16<br>25<br>35<br>50<br>65<br>**•**<br>**•**<br>**•**<br>8.07/205<br>4.13/105<br>4.07/103.5<br>20,000|400-600(3)<br>2-3-4(4)<br>600<br>600<br>N<br>S<br>H<br>L<br>V<br>65<br>100 150 200 200<br>25<br>35<br>65<br>100 150<br>18<br>25<br>35<br>65<br>100<br>25<br>35<br>50<br>65<br>100<br>16<br>25<br>35<br>50<br>65<br>**•**<br>**•**<br>8.07/205<br>5.51/140<br>4.07/103.5<br>20,000|800<br>3-4<br>600<br>600<br>N<br>S<br>H<br>L<br>65<br>100 200 200<br>35<br>50<br>65<br>100<br>20<br>25<br>35<br>42<br>35<br>35<br>50<br>65<br>20<br>20<br>35<br>50<br>**•**<br>**•**<br>10.55/268<br>8.26/210<br>4.07/103.5<br>20,000|1000-1200<br>3-4<br>600<br>S<br>H<br>L<br>65<br>100<br>150<br>50<br>65<br>100<br>25<br>50<br>65<br>**•**<br>10.55/268<br>8.26/210<br>6.06/154 (toggle)<br>7/178 (motor)<br>10,000|1600, 2000,<br>2500 & 3000<br>3<br>600<br>**T8**<br>T8V<br>125<br>125<br>100<br>**•**<br>15 / 382<br>16.8 / 427<br>11.2 / 282<br>15,000| > (3) T5 600 with electronic trip units only and in three pole version- > (4) 2 pole T4N250 and T5N400 available only in N interrupting capacity. ABB 3 AC1615S - 03/10 **General Information** Catalog Number Explanation **Tmax** ## **- T3 S 080 T W 4 xxx** **==> picture [372 x 511] intentionally omitted <==** **----- Start of picture text -----**<br> Accessories (Added In Alpha-Numeric Order) [(1)]<br>A = Auxiliary Switch<br>S_ = Shunt trip with voltage code<br>U_ = Undervoltage release with voltage code<br>Number Of Poles<br>-1 = 1 pole (T1 only)<br>-2 = 2 pole<br>-4 = 4 pole<br>None = 3 pole<br>Type Connectors<br>W = None<br>L = Lugs on top/bottom termi-<br>nals<br>T = Lugs on top terminal<br>B = Lugs on bottom terminal<br>Trip Unit Function<br>B = LS/I (AC only)<br>D = Molded Case Switch (MCS)<br>T = Thermal-magnetic<br>M = Magnetic only (MCP)<br>E5 = Electronic MCP (AC only)<br>C = LSI (AC only)<br>E = LSIG (AC only)<br>P = PR332/P LI<br>R = PR332/P LSI<br>S = PR332/P LSIG<br>Hy Tmax<br>Current Rating On os<br> 015 = 15A 16 = 1600A<br> 080 = 80A 20 = 2000A<br> 100 = 100A 25 = 2500A<br> 225 250 = 250A= 225A 30 = 3000A =:<br> 400 = 400A : off<br> 600 = 600A<br> 800 = 800A<br>1000 = 1000A :.<br>1200 = 1200A<br>Interrupting Rating Class<br>B = Basic<br>N = Normal<br>S = Standard<br>H = High<br>L = Extra High<br>V = Very high<br>Frame Size<br>T1 = 100A T8 (3) = 1600A<br>T2 = 100A = 2000A<br>T3 = 225A = 2500A<br>Ts3 = 225A = 3000A<br>T4 = 250A<br>T5 = 400A, 600A<br>T6 = 600A, 800A<br>(2)<br>T7 = 1000A, 1200A<br>**----- End of picture text -----**<br> (1) Consult ABB for factory installed accessories. > (2) For T7, refer to page 40 (3) For T8, refer to page 46 ABB 4 AC1615S - 03/10 **T1** ## **T1** 100A, 600Y/347VAC, 480VAC ∆ Thermal-Magnetic **Dimensions** 3P Fixed Version 5.12H x 3.00W x 2.76D **Weight** 2.34 (Ibs) T1 ## **General** The T1 breaker family ranges from 15 through 100 amperes. The T1 trip units are non-interchangeable and use the very latest technology in electromagnetic relays for overcurrent trip protection. Thermal overload protection is provided by heat sensitive bimetals. Short-circuit protection for the breaker is accomplished using a precise magnetic coil. State of the art construction in contacts and arcing chambers aid in limiting damaging fault currents through the protected circuits. ## **Standards** The UL489/CSA C22.2 No. 5 version of T1 also carries an IEC-60947-2 rating. ## **Versions** The T1 frame is available in two versions: T = Thermal-magnetic, fi xed D = Molded case switch ## **Performance Levels** The T1 breaker has two performance levels available: B = Basic (Single Pole) ## **UL489 / CSA C22.2 Interrupting Capacity (kA RMS)** |Voltage|Continuous Rating|B (1-Pole)|N| |---|---|---|---| |240VAC|15<br>20 – 100|—<br>—|35<br>50| |277VAC|15<br>20 – 100|10<br>18|—<br>—| |347VAC|15<br>20 – 100|10<br>14|—<br>—| |480Y/277VAC|15|—|14| |480VAC|20 – 100|—|22| |600Y/347VAC|15 – 100|—|10| |250VDC 2 pole series|15 – 100A|—|25| |500VDC 3 pole series|15 – 100A|—|25| N = Normal (3 or 4 pole) ## **Number of Poles** The UL/CSA version of the T1 is available in single, three and four pole versions. IEC versions of the T1 are also available with the same dimensions up to 160 amperes. Please contact ABB for details. ## **Reverse Feeding** All versions of the T1 family are suitable for reverse feed applications. ## **Molded Case Switches** UL/CSA switches include no overcurrent protection except for a high instantaneous trip mechanism for self protection. ## **IEC 60947-2 Interrupting Capacity (kA RMS)** |Voltage|Continuous Rating|B (1-Pole)|N| |---|---|---|---| |230VAC|16 – 160A|25|50| |415VAC|16 – 160A|—|36| |440VAC|16 - 160A|—|22| |500VAC|16 - 160A|—|15| |690VAC|16 – 160A|—|6| |250VDC 2 pole series|16 - 160A|—|36| |500VDC 2 pole series|16 – 160A|—|36| ABB 5 AC1615S - 03/10 **T1** **T1** ## 600Y/347VAC, 480VAC ∆ Thermal-Magnetic/Molded Case Switch ## **T1-100A Frame** , Thermal-Magnetic Trip Unit Fixed, 1 pole |Breaker|IC at<br>347VAC|Rating|Magnetic<br>Trip|1-Pole, 347VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T1B|10kA|15A|1000A|T1B015TL-1|| ||14kA|20A<br>25A<br>30A<br>40A<br>50A<br>60A|1000A<br>1000A<br>1000A<br>1000A<br>1500A<br>1500A|T1B020TL-1<br>T1B025TL-1<br>T1B030TL-1<br>T1B040TL-1<br>T1B050TL-1<br>T1B060TL-1|| |||70A<br>80A<br>90A<br>100A|1500A<br>1500A<br>1500A<br>1500A|T1B070TL-1<br>T1B080TL-1<br>T1B090TL-1<br>T1B100TL-1|| ## **T1-100A Frame** , Thermal-Magnetic Trip Unit Fixed |Breaker|<br>IC at<br>480VAC|<br>Rating|<br>Magnetic<br>Trip|3-Pole, 600Y/347VAC/500VDC<br>Part Number|List<br>Price|4-Pole, 600Y/347VAC/500VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T1N|14kA|15A|1000A|T1N015TL||T1N015TL-4|| ||22kA|20A<br>25A<br>30A<br>40A<br>50A<br>60A|1000A<br>1000A<br>1000A<br>1000A<br>1500A<br>1500A|T1N020TL<br>T1N025TL<br>T1N030TL<br>T1N040TL<br>T1N050TL<br>T1N060TL||T1N020TL-4<br>T1N025TL-4<br>T1N030TL-4<br>T1N040TL-4<br>T1N050TL-4<br>T1N060TL-4|| |||70A<br>80A<br>90A<br>100A|1500A<br>1500A<br>1500A<br>1500A|T1N070TL<br>T1N080TL<br>T1N090TL<br>T1N100TL||T1N070TL-4<br>T1N080TL-4<br>T1N090TL-4<br>T1N100TL-4|| ## **T-100A Frame** ,100% Rated Thermal-Magnetic Trip Unit Fixed |Breaker|IC at <br>480VAC|Rating|Magnetic<br>Trip|3-Pole, 600Y/347VAC/500VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T1NQ|14kA|15(1)|1000A|T1NQ015TL|| ||22kA|20<br>25<br>30<br>40<br>50<br>60|1000A<br>1000A<br>1000A<br>1000A<br>1500A<br>1500A|T1NQ020TL<br>T1NQ025TL<br>T1NQ030TL<br>T1NQ040TL<br>T1NQ050TL<br>T1NQ060TL|| |||70<br>80<br>90<br>100|1500A<br>1500A<br>1500A<br>1500A|T1NQ070TL<br>T1NQ080TL<br>T1NQ090TL<br>T1NQ100TL|| ## **T1-100A Frame,** Molded Case Switch |Breaker|Interrupting<br>Capacity(2)|Rating|Magnetic<br>Trip|3-Pole, 600Y/347V/500VDC<br>Part Number|List<br>Price|4-Pole, 600Y/347V/500VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T1-D|240V, 50kA|100A|1000A|T1N100DL||TIN100DL-4|| > 2 When protected by a OCPD with appropriate ratings. 1 Rated 480Y/277VAC for 15A. 6 ABB **Discount Schedule DS-ST** AC1615S - 03/10 **T2** ## **T2** 100A, 480VAC ∆ Thermal-Magnetic/Electronic/Current Limiting **Dimensions** 3P Fixed Version 5.12H x 3.54W x 2.76D **Weight** 2.84 (Ibs) **==> picture [8 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> T2<br>**----- End of picture text -----**<br> ## **General** The T2 breaker family ranges from 10 through 100 amperes. The T2 trip units are non-interchangeable and use the very latest technology in electromagnetic relays for overcurrent trip protection as well as a version with microprocessorbased electronic trip unit. Thermal overload protection is provided by heat sensitive bimetals. State of the art construction in contacts and arcing chambers aid in limiting damaging fault currents through the protected circuits. ## **Standards** The UL489/CSA C22.2 No. 5 version of T2 also carries an IEC-60947-2 rating. ## **Versions** The T2 frame is available in four versions: - T = Thermal-magnetic, fi xed - B = Adjustable LS/I electronic - M = Magnetic only (MCP) - E5 = Electronic instantaneous only (MCP) ## **Trip Functions** These tripping functions are available: ## **UL489 / CSA C22.2 Interrupting Capacity (kA RMS)** |Voltage<br>240VAC|Continuous Rating<br>10 – 100A|S<br>65|H<br>150| |---|---|---|---| |480VAC ∆|10 – 100A|35|65| ## **IEC 60947-2 Interrupting Capacity (kA RMS)** |Voltage|Continuous Rating|S|H| |---|---|---|---| |230VAC|1.6 – 160A|85|100| |415VAC|1.6 – 160A|50|70| |440V|1.6 – 160A|45|55| |500V|1.6 – 160A|30|36| |690VAC|1.6 – 160A|7|8| |250VDC 2 pole series|1.6 – 160A|50|70| |500VDC 3 pole series|1.6 – 160A|50|70| - L = Long time - S = Short time - I = Instantaneous ## **Perfomance Levels** The T2 breaker has two performance levels available: - S = Standard - H = High - UL Current Limiting ## **Number of Poles** The UL/CSA version of the T2 is available in three and four pole versions. IEC versions of the T2 are also available with the same dimensions up to 160 amperes. Please contact ABB for details. ## **Reverse Feeding** All versions of the T2 family are suitable for reverse feed applications. ABB 7 AC1615S - 03/10 **T2** ## **T2** 100A, 480VAC ∆ Thermal-Magnetic/Current Limiting ## **T2-100A Frame** , Thermal-Magnetic Trip Unit Fixed |Breaker<br>|IC at<br>480VAC<br>|Rating<br>|Magnetic<br>Trip<br>|3-Pole, 480VAC<br>Part Number|List<br>Price|4-Pole, 480VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T2S|35kA|15A<br>20A<br>25A<br>30A<br>40A<br>50A<br>60A|500A<br>500A<br>500A<br>500A<br>500A<br>500A<br>600A|T2S015TW<br>T2S020TW<br>T2S025TW<br>T2S030TW<br>T2S040TW<br>T2S050TW<br>T2S060TW||T2S015TW-4<br>T2S020TW-4<br>T2S025TW-4<br>T2S030TW-4<br>T2S040TW-4<br>T2S050TW-4<br>T2S060TW-4|| |||70A<br>80A<br>90A<br>100A|700A<br>800A<br>900A<br>1000A|T2S070TW<br>T2S080TW<br>T2S090TW<br>T2S100TW||T2S070TW-4<br>T2S080TW-4<br>T2S090TW-4<br>T2S100TW-4|| |Breaker<br>IC at<br>480VAC|Breaker<br>IC at<br>480VAC|Rating|Magnetic<br>Trip|3-Pole, 480VAC<br>Part Number|List<br>Price|4-Pole, 480VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T2H<br>UL Current Limiting|65kA<br>|15A<br>20A<br>25A<br>30A<br>40A<br>50A<br>60A|500A<br>500A<br>500A<br>500A<br>500A<br>500A<br>600A|T2H015TW<br>T2H020TW<br>T2H025TW<br>T2H030TW<br>T2H040TW<br>T2H050TW<br>T2H060TW||T2H015TW-4<br>T2H020TW-4<br>T2H025TW-4<br>T2H030TW-4<br>T2H040TW-4<br>T2H050TW-4<br>T2H060TW-4|| |||70A<br>80A<br>90A<br>100A|700A<br>800A<br>900A<br>1000A|T2H070TW<br>T2H080TW<br>T2H090TW<br>T2H100TW||T2H070TW-4<br>T2H080TW-4<br>T2H090TW-4<br>T2H100TW-4|| ## **T2-100A Frame** , 100% Rated Thermal-Magnetic Trip Unit Fixed |Breaker<br>|IC at<br>480VAC<br>|Rating<br>|Magnetic<br>Trip<br>|3-Pole, 480VAC<br>Part Number<br>|List<br>Price| |---|---|---|---|---|---| |T2SQ|35kA|15A<br>20A<br>25A<br>30A<br>40A<br>50A<br>60A|500A<br>500A<br>500A<br>500A<br>500A<br>500A<br>600A|T2SQ015TW<br>T2SQ020TW<br>T2SQ025TW<br>T2SQ030TW<br>T2SQ040TW<br>T2SQ050TW<br>T2SQ060TW|| |||70A<br>80A<br>90 A<br>100A|700A<br>800A<br>900A<br>1000A|T2SQ070TW<br>T2SQ080TW<br>T2SQ090TW<br>T2SQ100TW|| |Breaker|IC at<br>480VAC|Rating|Magnetic<br>Trip|3-Pole, 480VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T2HQ<br>UL Current Limiting|<br>65kA|15A<br>20A<br>25A<br>30A<br>40A<br>50A<br>60A|500A<br>500A<br>500A<br>500A<br>500A<br>500A<br>600A|T2HQ015TW<br>T2HQ020TW<br>T2HQ025TW<br>T2HQ030TW<br>T2HQ040TW<br>T2HQ050TW<br>T2HQ060TW|| |||70A<br>80A<br>90A<br>100A|700A<br>800A<br>900A<br>1000A|T2HQ070TW<br>T2HQ080TW<br>T2HQ090TW<br>T2HQ100TW|| 8 ABB **Discount Schedule DS-ST** AC1615S - 03/10 **T2** ## **T2** 100A, 480VAC ∆ Electronic/Current Limiting, 100% Rated, MCP ## **T2-100A Frame,** Electronic Trip Unit (AC Only) |Breaker|IC at<br>480VAC|Trip Unit<br>Type|CT<br>Rating|3-Pole, 480VAC<br>Part Number|List<br>Price|4-Pole, 480VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T2S|35kA|PR221DS-LS/I|25A<br>60A<br>100A|T2S025BW<br>T2S060BW<br>T2S100BW||T2S025BW-4<br>T2S060BW-4<br>T2S100BW-4|| |T2H<br>UL Current Limiting|65kA|PR221DS-LS/I|25A<br>60A<br>100A|T2H025BW<br>T2H060BW<br>T2H100BW||T2H025BW-4<br>T2H060BW-4<br>T2H100BW-4|| ## **T2-100A Frame,** 100% Rated Electronic Trip Unit (AC Only) |Breaker|IC at<br>480VAC|Trip Unit<br>Type|CT<br>Rating|3-Pole, 480VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T2SQ|35kA|PR221DS-LS/I|25A<br>60A|T2SQ025BW<br>T2SQ060BW|| ||||100A|T2SQ100BW|| |T2HQ<br>UL Current Limiting|65kA|PR221DS-LS/I|25A<br>60A|T2HQ025BW<br>T2HQ060BW|| ||||100A|T2HQ100BW|| ## **T2 -100A Frame,** Motor Control Protection (MCP) Magnetic Only Trip Unit |Breaker|IC at<br>480VAC|Trip Unit<br>Type|Rating|Adjustment<br>Range|3-Pole, 480VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---| |T2S|35kA|Mag only|20A<br>50A<br>100A|120 - 240<br>300 - 600<br>600 – 1200|T2S020MW<br>T2S050MW<br>T2S100MW|| |T2H|65kA|Mag only|20A<br>50A<br>100A|120 - 240<br>300 - 600<br>600 – 1200|T2H020MW<br>T2H050MW<br>T2H100MW|| ## **T2 -100A Frame,** Motor Control Protection (MCP) Magnetic Only Electronic Trip Unit (AC Only) |Breaker|IC at<br>480VAC|Trip Unit<br>Type|Rating|Adjustment<br>Range|3-Pole, 480VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---| |T2S|35kA|Instantaneous<br>only|25A<br>60A<br>100A|25 - 250<br>60 - 600<br>100 - 1000|T2S025E5W<br>T2S060E5W<br>T2S100E5W|| |T2H|65kA|Instantaneous<br>only|25A<br>60A<br>100A|25 - 250<br>60 - 600<br>100 - 1000|T2H025E5W<br>T2H060E5W<br>T2H100E5W|| ABB 9 **Discount Schedule DS-ST** AC1615S - 03/10 **T3** **T3** ## 225A, 600Y/347VAC, 480VAC ∆ Thermal-Magnetic **Dimensions** 3P Fixed Version 5.9H x 4.13W x 2.76D **Weight** 5.45 (Ibs) **==> picture [8 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> T3<br>**----- End of picture text -----**<br> ## **General** The T3 breaker family ranges from 60 through 225 amperes. The T3 trip units are non-interchangeable and use the very latest technology in electromagnetic relays for overcurrent trip protection. Thermal overload protection is provided by heat sensitive bimetals. Short-circuit protection begins at 10 times the thermal rating of the breaker using a precise magnetic coil. State of the art construction in contacts and arcing chambers aid in limiting damaging fault currents through the protected circuits. ## **Standards** ## **UL489 / CSA C22.2 Interrupting Capacity (kA RMS)** |Voltage|Continuous Rating|N|S| |---|---|---|---| |Voltage|Continuous Rating|N|S| |240VAC|60 – 225A|50|65| |480VAC ∆|60 – 225A|25|35| |600Y/347VAC|60 – 225A|10|10| |250VDC(1)|60 – 225A|25|35| |500VDC(2)|60 – 225A|25|35| The UL489/CSA C22.2 No. 5 version of T3 also carries an IEC-60947-2 rating. ## **Versions** The T3 frame is available in three versions: - T = Thermal-magnetic, fi xed - M = Magnetic only (MCP) - D = Molded case switch ## **Performance Levels** The T3 breaker has two performance levels available: - N = Normal - S = Standard ## **Number of Poles** ## **IEC 60947-2 Interrupting Capacity (kA RMS)** |Voltage|Continuous Rating|B (1-Pole)|N| |---|---|---|---| |230VAC|63 – 250A|50|85| |415VAC|63 – 250A|36|50| |440V|63 – 250A|25|40| |500V|63 – 250A|20|30| |690VAC|63 – 250A|5|8| |250VDC(1)|63 – 250A|36|50| |500VDC(2)|63 – 250A|36|50| The UL/CSA version of the T3 is available in three and four pole versions. IEC versions of the T3 are also available with the same dimensions up to 250 amperes. Please contact ABB for details. ## **Molded Case Switches** UL/CSA switches include no overcurrent protection except for a high instantaneous trip mechanism for self protection. ## **Reverse Feeding** All versions of the T3 family are suitable for reverse feed application. > (1) 2 poles in series. > (2) 3 poles in series. 10 ABB AC1615S - 03/10 **T3** ## **T3** 225A, 600Y/347VAC, 480VAC ∆ Thermal-Magnetic ## **T3-225A Frame,** Thermal-Magnetic Trip Unit Fixed |Breaker|IC at<br>480VAC|Rating|Magnetic<br>Trip|3-Pole, 600Y/347VAC-500DC<br>Part Number|List<br>Price|4-Pole, 600Y/347VAC-500DC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T3N|25kA|60A|600A|T3N060TW||T3N060TW-4|| |||70A<br>80A<br>90A<br>100A|700A<br>800A<br>900A<br>1000A|T3N070TW<br>T3N080TW<br>T3N090TW<br>T3N100TW||T3N070TW-4<br>T3N080TW-4<br>T3N090TW-4<br>T3N100TW-4|| |||125A<br>150A<br>175A<br>200A<br>225A|1250A<br>1500A<br>1750A<br>2000A<br>2250A|T3N125TW<br>T3N150TW<br>T3N175TW<br>T3N200TW<br>T3N225TW||T3N125TW-4<br>T3N150TW-4<br>T3N175TW-4<br>T3N200TW-4<br>T3N225TW-4|| |Breaker|IC at<br>480VAC|Rating|Magnetic<br>Trip|3-Pole, 600Y/347VAC-500DC<br>Part Number|List<br>Price|4-Pole, 600Y/347VAC-500DC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T3S|35kA|60A|600A|T3S060TW||T3S060TW-4|| |||70A<br>80A<br>90A<br>100A|700A<br>800A<br>900A<br>1000A|T3S070TW<br>T3S080TW<br>T3S090TW<br>T3S100TW||T3S070TW-4<br>T3S080TW-4<br>T3S090TW-4<br>T3S100TW-4|| |||125A<br>150A<br>175A<br>200A<br>225A|1250A<br>1500A<br>1750A<br>2000A<br>2250A|T3S125TW<br>T3S150TW<br>T3S175TW<br>T3S200TW<br>T3S225TW||T3S125TW-4<br>T3S200TW-4<br>T3S175TW-4<br>T3S200TW-4<br>T3S225TW-4|| ## **T3-225A Frame,** 100% Rated Thermal-Magnetic Trip Unit Fixed |Breaker|IC at<br>480VAC|Rating|Magnetic<br>Trip|3-Pole, 600Y/347VAC-500VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T3NQ|25kA|60A|600A|T3NQ060TW|| |||70A<br>80A<br>90A<br>100A|700A<br>800A<br>900A<br>1000A|T3NQ070TW<br>T3NQ080TW<br>T3NQ090TW<br>T3NQ100TW|| |||125A<br>150A<br>175A<br>200A<br>225A|1250A<br>1500A<br>1750A<br>2000A<br>2250A|T3NQ125TW<br>T3NQ150TW<br>T3NQ175TW<br>T3NQ200TW<br>T3NQ225TW|| |Breaker|IC at<br>480VAC|Rating|Magnetic<br>Trip|3-Pole, 600Y/347VAC-500VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T3SQ|35kA|60A|600A|T3SQ060TW|| |||70A<br>80A<br>90A<br>100A|700A<br>800A<br>900A<br>1000A|T3SQ070TW<br>T3SQ080TW<br>T3SQ090TW<br>T3SQ100TW|| |||125A<br>150A<br>175A<br>200A<br>225A|1250A<br>1500A<br>1750A<br>2000A<br>2250A|T3SQ125TW<br>T3SQ150TW<br>T3SQ175TW<br>T3SQ200TW<br>T3SQ225TW|| ABB 11 **Discount Schedule DS-ST** AC1615S - 03/10 ## **T3** ## **T3** 225A, 600Y/347VAC, 480VAC ∆ MCP/Molded Case Switch ## **T3-225A Frame,** Motor Control Protection (MCP) Magnetic Only Trip Unit |Breaker<br>|IC at<br>480VAC<br>|IC at<br>600Y/347VAC<br>|IC at<br>500VDC<br>|Trip Unit<br>Type<br>|Rating<br>|Adjustment<br>Range<br>|3-Pole, 600Y/347VAC-500VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---|---| |T3S|35kA|10kA|35kA|Mag only|100A<br>125A<br>150A<br>200A|600 – 1200<br>750 - 1500<br>900 - 1800<br>1200 - 2400|T3S100MW<br>T3S125MW<br>T3S150MW<br>T3S200MW|| ## **T3S-225A Frame,** Molded Case Switch |Breaker<br>|Rating<br>|Magnetic<br>Trip|3-Pole, 600Y/347VAC-500VDC<br>Part Number|List<br>Price|4-Pole, 600Y/3 500VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---| |T3S-D|150A<br>225A|1500A<br>2250A|T3S150DW<br>T3S225DW||T3S150DW-4<br>T3S225DW-4|| 12 ABB **Discount Schedule DS-ST** AC1615S - 03/10 **Ts3** 150A 600VAC ∆ / 225A, 480VAC Thermal-Magnetic **Ts3** **Dimensions** 3P Fixed Version 6.7H x 4.13W x 4.07D **Weight** 6.75 (Ibs) **==> picture [11 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> Ts3<br>**----- End of picture text -----**<br> ## **General** The Ts3 breaker family ranges from 15 through 225 amperes. The Ts3 trip mech a nisms are non-interchangeable and use sen si tive elec tro mag net ic relays for overcurrent trip pro tec tion. Heat sensitive bimetals are used for ther mal over cur rent protection. Short-circuit cur rent protection begins at 10 times the ther mal rating of the breaker and uses a magnetic coil principle. ## **Standards** The UL489/CSA C22.2 No. 5 version of Ts3 also carries an IEC-60947-2 rating. ## **Versions** ## **UL/CSA Interrupting Capacity** (kA RMS) **UL489 / CSA C22.2** |Voltage|N|H|L| |---|---|---|---| |240 VAC<br>480 VAC<br>600 VAC(2)<br>500 VDC(4)<br>600 VDC(5)<br>Ts3/225A 500VDC(3)|65<br>25<br>14<br>35<br>20<br>20|100<br>50<br>14<br>50<br>35<br>35|150<br>85(1)<br>25<br>65<br>50<br>50| To meet all application needs, the Ts3 is available in various versions: - T = Thermal-magnetic - D = Molded case switch - M = Magnetic only (MCP) ## **Performance Level** Each version is also available in different maximum fault in ter rupt ing levels - N = Normal - H = High - L = Extra high ## **Number of Poles** ## **IEC-60947-2 Interrupting Capacity (kA RMS)** |Voltage|N|H|L| |---|---|---|---| |230 VAC<br>380/400/415VAC<br>440 VAC<br>500 VAC<br>690 VAC<br>500 VDC<br>750 VDC|65<br>35<br>30<br>25<br>14<br>35<br>20|100<br>65<br>50<br>40<br>18<br>50<br>35|170<br>85<br>65<br>50<br>20<br>65<br>50| In UL/CSA form, the Ts3 is available in two pole or three pole versions, both with the same dimensions. A four-pole version is also available in the N version. For price estimation, add 35% to list price of selected version three pole breaker, contact ABB for details. ## **Molded Case Switches** UL/CSA switches include no overcurrent protection except for a high instantaneous trip mechanism for self protection. IEC type molded case switches with no trip protection are also available. ## **Reverse Feeding** All versions of the Ts3 family are suitable for reverse feed application. > (1) 15-30A and 175-200-225A are 65kA at 480VAC > (2) Ts3 175A, 200A, 225A are rated 480VAC / 500DVC maximum > (3) Ts3 175A, 200A, 225A > (4) 2 poles in series > (5) 3 poles in series ABB 13 AC1615S - 03/10 **Ts3** ## **Ts3** ## 150A, 600VAC ∆ / 225A, 480VAC ∆ Thermal-Magnetic ## **Ts3-150A Frame,** Thermal-Magnetic Trip Unit Fixed |Breaker|IC at<br>600VAC|Rating|Magnetic<br>Trip|2-Pole, 480VAC/500VDC<br>Part Number|List<br>Price|3-Pole, 600VAC/600VDC<br>Part Number|List<br>Price|4-Pole, 600VAC/600VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---|---|---| |Ts3N||15A|500A|Ts3N015TW-2||Ts3N015TW||Ts3N015TW-4|| |||20A|500A|Ts3N020TW-2||Ts3N020TW||Ts3N020TW-4|| |||25A|500A|Ts3N025TW-2||Ts3N025TW||Ts3N025TW-4|| |||30A|500A|Ts3N030TW-2||Ts3N030TW||Ts3N030TW-4|| |||35A|500A|Ts3N035TW-2||Ts3N035TW||Ts3N035TW-4|| |||40A|500A|Ts3N040TW-2||Ts3N040TW||Ts3N040TW-4|| ||14kA|50A|500A|Ts3N050TW-2||Ts3N050TW||Ts3N050TW-4|| |||60A|600A|Ts3N060TW-2||Ts3N060TW||Ts3N060TW-4|| |||70A|700A|Ts3N070TW-2||Ts3N070TW||Ts3N070TW-4|| |||80A|800A|Ts3N080TW-2||Ts3N080TW||Ts3N080TW-4|| |||90A|900A|Ts3N090TW-2||Ts3N090TW||Ts3N090TW-4|| |||100A|1000A|Ts3N100TW-2||Ts3N100TW||Ts3N100TW-4|| |||125A|1250A|Ts3N125TW-2||Ts3N125TW||Ts3N125TW-4|| |||150A|1500A|Ts3N150TW-2||Ts3N150TW||Ts3N150TW-4|| ||IC at|175A(1)|1750A|Ts3N175TW-2||Ts3N175TW||Ts3N175TW-4|| ||480VAC|200A(1)|2000A|Ts3N200TW-2||Ts3N200TW||Ts3N200TW-4|| ||25kA|225A(1)|2250A|Ts3N225TW-2||Ts3N225TW||Ts3N225TW-4|| ||||||List<br>Price<br>3-Pole, 600VAC/600VDC<br>Part Number<br>List<br>Price<br>Ts3H015TW<br>Ts3H020TW<br>Ts3H025TW<br>Ts3H030TW<br>Ts3H035TW<br>Ts3H040TW<br>Ts3H050TW<br>Ts3H060TW<br>Ts3H070TW<br>Ts3H080TW<br>Ts3H090TW<br>Ts3H100TW<br>Ts3H125TW<br>Ts3H150TW<br>Ts3H175TW<br>Ts3H200TW<br>Ts3H225TW<br>List<br>Price<br>3-Pole, 600VAC/600VDC<br>Part Number<br>List<br>Price<br>Ts3L015TW<br>Ts3L020TW<br>Ts3L025TW<br>Ts3L030TW<br>Ts3L035TW<br>Ts3L040TW<br>Ts3L050TW<br>Ts3L060TW<br>Ts3L070TW<br>Ts3L080TW<br>Ts3L090TW<br>Ts3L100TW<br>Ts3L125TW<br>Ts3L150TW<br>Ts3L175TW<br>Ts3L200TW<br>Ts3L225TW||||| |Breaker|IC at<br>600VAC|Rating|Magnetic<br>Trip|2-Pole, 480VAC/500VDC<br>Part Number|List<br>Price|3-Pole, 600VAC/600VDC<br>Part Number|List<br>Price||| |Ts3H||15A|500A|Ts3H015TW-2||Ts3H015TW|||| |||20A|500A|Ts3H020TW-2||Ts3H020TW|||| |||25A|500A|Ts3H025TW-2||Ts3H025TW|||| |||30A|500A|Ts3H030TW-2||Ts3H030TW|||| |||35A|500A|Ts3H035TW-2||Ts3H035TW|||| |||40A|500A|Ts3H040TW-2||Ts3H040TW|||| ||14kA|50A|500A|Ts3H050TW-2||Ts3H050TW|||| |||60A|600A|Ts3H060TW-2||Ts3H060TW|||| |||70A|700A|Ts3H070TW-2||Ts3H070TW|||| |||80A|800A|Ts3H080TW-2||Ts3H080TW|||| |||90A|900A|Ts3H090TW-2||Ts3H090TW|||| |||100A|1000A|Ts3H100TW-2||Ts3H100TW|||| |||125A|1250A|Ts3H125TW-2||Ts3H125TW|||| |||150A|1500A|Ts3H150TW-2||Ts3H150TW|||| ||IC at|175A(1)|1750A|Ts3H175TW-2||Ts3H175TW|||| ||480VAC|200A(1)|2000A|Ts3H200TW-2||Ts3H200TW|||| ||50kA|225A(1)|2250A|Ts3H225TW-2||Ts3H225TW|||| ||||||||||| |Breaker|IC at<br>600VAC|Rating|Magnetic<br>Trip|2-Pole, 480VAC/500VDC<br>Part Number|List<br>Price|3-Pole, 600VAC/600VDC<br>Part Number|List<br>Price||| |Ts3L||15A|500A|Ts3L015TW-2||Ts3L015TW|||| |||20A|500A|Ts3L020TW-2||Ts3L020TW|||| |||25A|500A|Ts3L025TW-2||Ts3L025TW|||| |||30A|500A|Ts3L030TW-2||Ts3L030TW|||| |||35A|500A|Ts3L035TW-2||Ts3L035TW|||| |||40A|500A|Ts3L040TW-2||Ts3L040TW|||| ||25kA|50A|500A|Ts3L050TW-2||Ts3L050TW|||| |||60A|600A|Ts3L060TW-2||Ts3L060TW|||| |||70A|700A|Ts3L070TW-2||Ts3L070TW|||| |||80A|800A|Ts3L080TW-2||Ts3L080TW|||| |||90A|900A|Ts3L090TW-2||Ts3L090TW|||| |||100A|1000A|Ts3L100TW-2||Ts3L100TW|||| |||125A|1250A|Ts3L125TW-2||Ts3L125TW|||| |||150A|1500A|Ts3L150TW-2||Ts3L150TW|||| ||IC at|175A(1)|1750A|Ts3L175TW-2||Ts3L175TW|||| ||480VAC|200A(1)|2000A|Ts3L200TW-2||Ts3L200TW|||| ||65kA|225A(1)|2250A|Ts3L225TW-2||Ts3L225TW|||| (1) 480VAC/500VDC maximum ABB 14 **Discount Schedule DS-ST** AC1615S - 03/10 **Ts3** **Ts3** ## 150A, 600VAC ∆ / 225A, 480VAC ∆, 100% Rated Thermal-Magnetic ## **Ts3-225A Frame,** 100% Rated Thermal-Magnetic Trip Units |Breaker|IC at<br>600VAC|Rating|Magnetic<br>Trip|3-Pole, 600VAC/600VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |Ts3NQ||15A|500A|Ts3NQ015TW|| |||20A|500A|Ts3NQ020TW|| |||25A|500A|Ts3NQ025TW|| |||30A|500A|Ts3NQ030TW|| |||35A|500A|Ts3NQ035TW|| |||40A|500A|Ts3NQ040TW|| ||14kA|50A|500A|Ts3NQ050TW|| |||60A|600A|Ts3NQ060TW|| |||70A|700A|Ts3NQ070TW|| |||80A|800A|Ts3NQ080TW|| |||90A|900A|Ts3NQ090TW|| |||100A|1000A|Ts3NQ100TW|| |||125A|1250A|Ts3NQ125TW|| |||150A|1500A|Ts3NQ150TW|| ||IC at|175A(1)|1750A|Ts3NQ175TW|| ||480VAC|200A(1)|2000A|Ts3NQ200TW|| ||25kA|225A(1)|2250A|Ts3NQ225TW|| ||||||| |Breaker|IC at<br>600VAC|Rating|Magnetic<br>Trip|3-Pole, 600VAC/600VDC<br>Part Number|List<br>Price| |Ts3HQ||15A|500A|Ts3HQ015TW|| |||20A|500A|Ts3HQ020TW|| |||25A|500A|Ts3HQ025TW|| |||30A|500A|Ts3HQ030TW|| |||35A|500A|Ts3HQ035TW|| |||40A|500A|Ts3HQ040TW|| |||50A|500A|Ts3HQ050TW|| ||14kA|60A|600A|Ts3HQ060TW|| |||70A|700A|Ts3HQ070TW|| |||80A|800A|Ts3HQ080TW|| |||90A|900A|Ts3HQ090TW|| |||100A|1000A|Ts3HQ100TW|| |||125A|1250A|Ts3HQ125TW|| |||150A|1500A|Ts3HQ150TW|| ||IC at|175A(1)|1750A|Ts3HQ175TW|| ||480VAC|200A(1)|2000A|Ts3HQ200TW|| ||50kA|225A(1)|2250A|Ts3HQ225TW|| ||||||| |Breaker|IC at<br>600VAC|Rating|Magnetic<br>Trip|3-Pole, 600VAC/600VDC<br>Part Number|List<br>Price| |Ts3LQ||15A|500A|Ts3LQ015TW|| |||20A|500A|Ts3LQ020TW|| |||25A|500A|Ts3LQ025TW|| |||30A|500A|Ts3LQ030TW|| |||35A|500A|Ts3LQ035TW|| |||40A|500A|Ts3LQ040TW|| |||50A|500A|Ts3LQ050TW|| ||25kA|60A|600A|Ts3LQ060TW|| |||70A|700A|Ts3LQ070TW|| |||80A|800A|Ts3LQ080TW|| |||90A|900A|Ts3LQ090TW|| |||100A|1000A|Ts3LQ100TW|| |||125A|1250A|Ts3LQ125TW|| |||150A|1500A|Ts3LQ150TW|| ||IC at|175A(1)|1750A|Ts3LQ175TW|| ||480VAC|200A(1)|2000A|Ts3LQ200TW|| ||65kA|225A(1)|2250A|Ts3LQ225TW|| (1) 480VAC/500VDC maximum ABB 15 **Discount Schedule DS-ST** AC1615S - 03/10 **Ts3** **Ts3** ## 150A, 600VAC ∆ / 225A, 450VAC, 480VAC MCP/Molded Case Switch ## **Ts3-225A Frame,** Motor Control Protection (MCP) Magnetic Only Trip Unit |Breaker|IC at<br>480VAC|ICat<br>600VAC|ICat<br>500VDC|ICat<br>600VDC|Trip Unit Type|Rating|Adjustment<br>Range|3-Pole, 600VAC/600VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---|---|---| |Ts3L|25kA|10kA|-|50kA|Mag only|3|12-36|Ts3L003MW|| ||25kA|10kA|-|50kA|Mag only|5|20-60|Ts3L005MW|| ||25kA|10kA|-|50kA|Mag only|10|40-120|Ts3L010MW|| ||25kA|10kA|65kA|50kA|Mag only|25|100-300|Ts3L025MW|| ||85kA|25kA|65kA|50kA|Mag only|50|200-600|Ts3L050MW|| ||85kA|25kA|65kA|50kA|Mag only|100|400-1200|Ts3L100MW|| ||85kA|25kA|65kA|50kA|Mag only|125|500-1500|Ts3L125MW|| ||85kA|25kA|50kA|50kA|Mag only|150|600-1500|Ts3L150MW|| ||65kA|-|50kA|-|Mag only|175(1)|700-2100|Ts3L175MW|| ||65kA|-|50kA|-|Mag only|200(1)|800-2400|Ts3L200MW|| ## **Ts3-225A Frame,** Molded Case Switch |Type|Voltage (max.)|Magnetic Trip|Amps|3-Pole 600VAC/600VDC<br>Part Number|List<br>Price|4-Pole, 600VAC/600VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |Ts3H|600VAC/600VDC|1500|150|Ts3H150DW||Ts3H150DW-4|| ||480VAC/500VDC|2250|225(1)|Ts3H225DW||Ts3H225DW-4|| (1) 480VAC/500VDC Maximum 16 ABB **Discount Schedule DS-ST** AC1615S - 03/10 **T4** ## **T4** 250A, 600VAC ∆ Electronic and Thermal-Magnetic **Dimensions** 3P Fixed Version 8.07H x 4.13W x 4.07D **Weight** 6.18 (Ibs) **==> picture [8 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> T4<br>**----- End of picture text -----**<br> ## **General** The T4 breaker is a 250 amp frame with either a microprocessor based over current protective trip system or a thermal magnetic trip unit. ## **Standards** The UL489/CSA C22.2 No. 5 version of T4 also carries an IEC-60947-2 rating. ## **Versions** To meet all application requirements, the T4 is available in the following versions: ## **UL489 / CSA C22.2 Interrupting Capacity (kA RMS)** |Voltage|Continuous Rating|N|S|H|L|V| |---|---|---|---|---|---|---| |240VAC|20 - 250A|65|100|150|200|200| |480VAC|20 - 250A|25|35|65|100|150| |600VAC|20 - 250A|18|25|35|65|100| |500VDC<br> (1)|20 - 250A|25|35|50|65|100| |600VDC (2)|20 - 250A|16|25|35|50|65| - T = Thermal-magnetic - B = Selectable & adjustable LI or LS - C = Adjustable LSI - E = Adjustable LSIG - D = Molded Case Switch - E5 = Electronic instantaneous only (MCP) ## **Trip Functions** These trip functions are available: - L = Long time - S = Short time - I = Instantaneous - G = Ground fault ## **IEC 60947-2 Interrupting Capacity (kA RMS)** |Voltage|Continuous Rating|N|S|H|L|V| |---|---|---|---|---|---|---| |230VAC|20 - 320A|70|85|100|200|200| |415VAC|20 - 320A|36|50|70|120|200| |440VAC|20 - 320A|30|40|65|100|180| |500VAC|20 - 320A|25|30|50|85|150| |690VAC|20 - 320A|20|25|40|70|80| |750VDC|20 - 320A|18|25|36|50|70| ## **Performance Levels** Each version is also available in different maximum fault interrupting levels: - N = Normal - S = Standard - H = High - UL Current Limiting - L = Extra high - V = Very high - UL Current Limiting ## **Number of Poles[(3)]** The T4 is available as a 2, 3 and 4 pole breaker. The 2 and 3 pole versions have the same dimensions. ## **Reverse Feeding** All versions of the T4 family are suitable for reverse feed application. > (1) 2 poles in series. > (2) 3 poles in series. > (3) 2 pole breakers available in N version only. 4 pole breakers available in N and H version only. ABB 17 AC1615S - 03/10 **T4** ## **T4** 250A, 600VAC ∆ Electronic (AC Only) ## **T4-100A Frame,** Electronic Trip Unit (AC Only) 40-100A Adjustable Range |Breaker|IC at<br>600VAC|Trip<br>Unit|2-Pole, 600VAC<br>Part Number|List<br>Price|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---|---| |T4N||PR221 LS/I|T4N100BW-2||T4N100BW||T4N100BW-4|| ||18kA|PR222 LSI|T4N100CW-2||T4N100CW||T4N100CW-4|| |||PR222 LSIG|T4N100EW-2||T4N100EW||T4N100EW-4|| |T4S||PR221 LS/I|||T4S100BW|||| ||25kA|PR222 LSI|||T4S100CW|||| |||PR222 LSIG|||T4S100EW|||| |T4H<br>UL Current Limiting||PR221 LS/I|||T4H100BW||T4H100BW-4|| ||35kA|PR222 LSI|||T4H100CW||T4H100CW-4|| |||PR222 LSIG|||T4H100EW||T4H100EW-4|| |T4L||PR221 LS/I|||T4L100BW|||| ||65kA|PR222 LSI|||T4L100CW|||| |||PR222 LSIG|||T4L100EW|||| |T4V<br>UL Current Limiting||PR221 LS/I|||T4V100BW|||| ||100kA|PR222 LSI|||T4V100CW|||| |||PR222 LSIG|||T4V100EW|||| ## **T4-150A Frame,** Electronic Trip Unit (AC Only) 60-150A Adjustable Range |Breaker|IC at<br>600VAC|Trip<br>Unit|2-Pole, 600VAC<br>Part Number|List<br>Price|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---|---| |T4N||PR221 LS/I|T4N150BW-2||T4N150BW||T4N150BW-4|| ||18kA|PR222 LSI|T4N150CW-2||T4N150CW||T4N150CW-4|| |||PR222 LSIG|T4N150EW-2||T4N150EW||T4N150EW-4|| |T4S||PR221 LS/I|||T4S150BW|||| ||25kA|PR222 LSI|||T4S150CW|||| |||PR222 LSIG|||T4S150EW|||| |T4H<br>UL Current Limiting||PR221 LS/I|||T4H150BW||T4H150BW-4|| ||35kA|PR222 LSI|||T4H150CW||T4H150CW-4|| |||PR222 LSIG|||T4H150EW||T4H150EW-4|| |T4L||PR221 LS/I|||T4L150BW|||| ||65kA|PR222 LSI|||T4L150CW|||| |||PR222 LSIG|||T4L150EW|||| |T4V<br>UL Current Limiting|100kA|PR221 LS/I<br>PR222 LSI<br>PR222 LSIG|||T4V150BW<br>T4V150CW<br>T4V150EW|||| |T4V<br>UL current limiting||PR221 LS/I|||T4V150BW|||| ||100|PR222 LSI|||T4V150CW|||| |||PR222 LSIG|||T4V150EW|||| ## **T4-250A Frame,** Electronic Trip Unit (AC Only) 100-250A Adjustable Range |Breaker|IC at<br>600VAC|Trip<br>Unit|2-Pole, 600VAC<br>Part Number|List<br>Price|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---|---| |T4N||PR221 LS/I|T4N250BW-2||T4N250BW||T4N250BW-4|| ||18kA|PR222 LSI|T4N250CW-2||T4N250CW||T4N250CW-4|| |||PR222 LSIG|T4N250EW-2||T4N250EW||T4N250EW-4|| |T4S||PR221 LS/I|||T4S250BW|||| ||25kA|PR222 LSI|||T4S250CW|||| |||PR222 LSIG|||T4S250EW|||| |T4H<br>UL Current Limiting||PR221 LS/I|||T4H250BW||T4H250BW-4|| ||35kA|PR222 LSI|||T4H250CW||T4H250CW-4|| |||PR222 LSIG|||T4H250EW||T4H250EW-4|| |T4L||PR221 LS/I|||T4L250BW|||| ||65kA|PR222 LSI|||T4L250CW|||| |||PR222 LSIG|||T4L250EW|||| |T4V<br>UL Current Limiting||PR221 LS/I|||T4V250BW|||| ||100kA|PR222 LSI|||T4V250CW|||| |||PR222 LSIG|||T4V250EW|||| 18 ABB **Discount Schedule DS-ST** AC1615S - 03/10 **T4** 250A, 600VAC ∆ Electronic 100% Rated (AC Only) **T4** |Breaker|IC at<br>600VAC|Trip<br>Unit|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---| |T4NQ||PR221 LS/I|T4NQ100BW|| ||18kA|PR222 LSI|T4NQ100CW|| |||PR222 LSIG|T4NQ100EW|| |T4SQ||PR221 LS/I|T4SQ100BW|| ||25kA|PR222 LSI|T4SQ100CW|| |||PR222 LSIG|T4SQ100EW|| |T4HQ<br>UL Current Limiting||PR221 LS/I|T4HQ100BW|| ||35kA|PR222 LSI|T4HQ100CW|| |||PR222 LSIG|T4HQ100EW|| |T4LQ||PR221 LS/I|T4LQ100BW|| ||65kA|PR222 LSI|T4LQ100CW|| |||PR222 LSIG|T4LQ100EW|| |T4VQ<br>UL Current Limiting||PR221 LS/I|T4VQ100BW|| ||100kA|PR222 LSI|T4VQ100CW|| |||PR222 LSIG|T4VQ100EW|| ## **T4-150A Frame,** 100% Rated Electronic Trip Unit (AC Only) 60-150A Adjustable Range |Breaker|IC at<br>600VAC|Trip<br>Unit|3-Pole, 600V<br>Part Number|List<br>Price| |---|---|---|---|---| |T4NQ||PR221 LS/I|T4NQ150BW|| ||18kA|PR222 LSI|T4NQ150CW|| |||PR222 LSIG|T4NQ150EW|| |T4SQ||PR221 LS/I|T4SQ150BW|| ||25kA|PR222 LSI|T4SQ150CW|| |||PR222 LSIG|T4SQ150EW|| |T4HQ<br>UL Current Limiting||PR221 LS/I|T4HQ150BW|| ||35kA|PR222 LSI|T4HQ150CW|| |||PR222 LSIG|T4HQ150EW|| |T4LQ||PR221 LS/I|T4LQ150BW|| ||65kA|PR222 LSI|T4LQ150CW|| |||PR222 LSIG|T4LQ150EW|| |T4VQ<br>UL Current Limiting||PR221 LS/I|T4VQ150BW|| ||100kA|PR222 LSI|T4VQ150CW|| |||PR222 LSIG|T4VQ150EW|| **T4-250A Frame,** 100% Rated Electronic Trip Unit (AC Only) 100-250A Adjustable Range |Breaker|IC at<br>600VAC|Trip<br>Unit|3-Pole, 600V<br>Part Number|List<br>Price| |---|---|---|---|---| |T4NQ||PR221 LS/I|T4NQ250BW|| ||18kA|PR222 LSI|T4NQ250CW|| |||PR222 LSIG|T4NQ250EW|| |T4SQ||PR221 LS/I|T4SQ250BW|| ||25kA|PR222 LSI|T4SQ250CW|| |||PR222 LSIG|T4SQ250EW|| |T4HQ<br>UL Current Limiting||PR221 LS/I|T4HQ250BW|| ||35kA|PR222 LSI|T4HQ250CW|| |||PR222 LSIG|T4HQ250EW|| |T4LQ||PR221 LS/I|T4LQ250BW|| ||65kA|PR222 LSI|T4LQ250CW|| |||PR222 LSIG|T4LQ250EW|| |T4VQ<br>UL Current Limiting||PR221 LS/I|T4VQ250BW|| ||100kA|PR222 LSI|T4VQ250CW|| |||PR222 LSIG|T4VQ250EW|| ABB 19 **Discount Schedule DS-ST** AC1615S - 03/10 **T4** ## **T4** 250A, 600VAC ∆ Thermal-Magnetic Trip Units ## **T4-250A Frame,** Thermal-Magnetic Trip Unit |Breaker|IC at<br>600VAC|Rating|Magnetic<br>Trip|3-Pole, 600VAC/600VDC<br>Part Number|List<br>Price|4-Pole, 600VAC/600VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T4N||20A|500|T4N020TW||T4N020TW-4|| |||30A (21-30A)|500|T4N030TW||T4N030TW-4|| |||40A (28-40A)|500|T4N040TW||T4N040TW-4|| |||50A (35-50A)|500|T4N050TW||T4N050TW-4|| ||kA|80A (56-80A)|400-800|T4N080TW||T4N080TW-4|| ||18|100A (70-100A)|500-1000|T4N100TW||T4N100TW-4|| |||125A (88-125A)|625-1250|T4N125TW||T4N125TW-4|| |||150A (105-150A)|750-1500|T4N150TW||T4N150TW-4|| |||200A (140-200A)|1000-2000|T4N200TW||T4N200TW-4|| |||250A(175-250A)|1250-2500|T4N250TW||T4N250TW-4|| |T4S||20A|500|T4S020TW|||| |||30A (21-30A)|500|T4S030TW|||| |||40A (28-40A)|500|T4S040TW|||| |||50A (35-50A)|500|T4S050TW|||| ||2kA|80A (56-80A)|400-800|T4S080TW|||| ||5|100A (70-100A)|500-1000|T4S100TW|||| |||125A (88-125A)|625-1250|T4S125TW|||| |||150A (105-150A)|750-1500|T4S150TW|||| |||200A (140-200A)|1000-2000|T4S200TW|||| |||250A(175-250A)|1250-2500|T4S250TW|||| |T4H<br>UL Current Limiting||20A|500|T4H020TW||T4H020TW-4|| |||30A (21-30A)|500|T4H030TW||T4H030TW-4|| |||40A (28-40A)|500|T4H040TW||T4H040TW-4|| |||50A (35-50A)|500|T4H050TW||T4H050TW-4|| ||kA|80A (56-80A)|400-800|T4H080TW||T4H080TW-4|| ||35|100A (70-100A)|500-1000|T4H100TW||T4H100TW-4|| |||125A (88-125A)|625-1250|T4H125TW||T4H125TW-4|| |||150A (105-150A)|750-1500|T4H150TW||T4H150TW-4|| |||200A (140-200A)|1000-2000|T4H200TW||T4H200TW-4|| |||250A(175-250A)|1250-2500|T4H250TW||T4H250TW-4|| |T4L||20A|500|T4L020TW|||| |||30A (21-30A)|500|T4L030TW|||| |||40A (28-40A)|500|T4L040TW|||| |||50A (35-50A)|500|T4L050TW|||| ||kA|80A (56-80A)|400-800|T4L080TW|||| ||65|100A (70-100A)|500-1000|T4L100TW|||| |||125A (88-125A)|625-1250|T4L125TW|||| |||150A (105-150A)|750-1500|T4L150TW|||| |||200A (140-200A)|1000-2000|T4L200TW|||| |||250A(175-250A)|1250-2500|T4L250TW|||| |T4V<br>UL Current Limiting||20A|500|T4V020TW|||| |||30A (21-30A)|500|T4V030TW|||| |||40A (28-40A)|500|T4V040TW|||| |||50A (35-50A)|500|T4V050TW|||| ||kA|80A (56-80A)|400-800|T4V080TW|||| ||100|100A (70-100A)|500-1000|T4V100TW|||| |||125A (88-125A)|625-1250|T4V125TW|||| |||150A (105-150A)|750-1500|T4V150TW|||| |||200A (140-200A)|1000-2000|T4V200TW|||| |||250A(175-250A)|1250-2500|T4V250TW|||| |||Rating<br>Magnetic<br>Trip<br>2-Pole, 600VAC/500VDC<br>Part Number<br>List<br>Price<br>30A (21-30A)<br>500<br>T4N030TW-2<br>40A (28-40A)<br>500<br>T4N040TW-2<br>50A (35-50A)<br>500<br>T4N050TW-2<br>80A (56-80A)<br>400-800<br>T4N080TW-2<br>100A (70-100A)<br>500-1000<br>T4N100TW-2<br>125A (88-125A)<br>625-1250<br>T4N125TW-2<br>150A (100-150A)<br>750-1500<br>T4N150TW-2<br>200A (140-200A)<br>1000-2000<br>T4N200TW-2<br>250A(175-250A)<br>1250-2500<br>T4N250TW-2|||||| |Breaker|IC at<br>600VAC|Rating|Magnetic<br>Trip|2-Pole, 600VAC/500VDC<br>Part Number|List<br>Price||| |T4N||30A (21-30A)|500|T4N030TW-2|||| |||40A (28-40A)|500|T4N040TW-2|||| |||50A (35-50A)|500|T4N050TW-2|||| |||80A (56-80A)|400-800|T4N080TW-2|||| ||18kA|100A (70-100A)|500-1000|T4N100TW-2|||| |||125A (88-125A)|625-1250|T4N125TW-2|||| |||150A (100-150A)|750-1500|T4N150TW-2|||| |||200A (140-200A)|1000-2000|T4N200TW-2|||| |||250A(175-250A)|1250-2500|T4N250TW-2|||| 20 ABB **Discount Schedule DS-ST** AC1615S - 03/10 **T4** 250A, 600VAC 100% Rated Thermal-Magnetic Trip Units **T4** ## **T4-250A Frame,** 100% Rated Thermal-Magnetic Trip Unit |Breaker|IC at<br>600VAC|Rating|Magnetic<br>Trip|3-Pole, 600VAC/600VDC<br>Part Number|List<br>Price|| |---|---|---|---|---|---|---| |T4NQ||20A|500|T4NQ020TW||| |||30A (21-30A)|500|T4NQ030TW||| |||40A (28-40A)|500|T4NQ040TW||| |||50A (35-50A)|500|T4NQ050TW||| ||kA|80A (56-80A)|400-800|T4NQ080TW||| ||18|100A (70-100A)|500-1000|T4NQ100TW||| |||125A (88-125A)|625-1250|T4NQ125TW||| |||150A (105-150A)|750-1500|T4NQ150TW||| |||200A (140-200A)|1000-2000|T4NQ200TW||| |||250A(175-250A)|1250-2500|T4NQ250TW||| |T4SQ||20A|500|T4SQ020TW||| |||30A (21-30A)|500|T4SQ030TW||| |||40A (28-40A)|500|T4SQ040TW||| |||50A (35-50A)|500|T4SQ050TW||| ||2kA|80A (56-80A)|400-800|T4SQ080TW||| ||5|100A (70-100A)|500-1000|T4SQ100TW||| |||125A (88-125A)|625-1250|T4SQ125TW||| |||150A (105-150A)|750-1500|T4SQ150TW||| |||200A (140-200A)|1000-2000|T4SQ200TW||| |||250A(175-250A)|1250-2500|T4SQ250TW||| |T4HQ||20A|500|T4HQ020TW||| |||30A (21-30A)|500|T4HQ030TW||| |||40A (28-40A)|500|T4HQ040TW||| |||50A (35-50A)|500|T4HQ050TW||| ||kA|80A (56-80A)|400-800|T4HQ080TW||| ||35|100A (70-100A)|500-1000|T4HQ100TW||| |||125A (88-125A)|625-1250|T4HQ125TW||| |||150A (105-150A)|750-1500|T4HQ150TW||| |||200A (140-200A)|1000-2000|T4HQ200TW||| |||250A(175-250A)|1250-2500|T4HQ250TW||| |T4LQ||20A|500|T4LQ020TW||| |||30A (21-30A)|500|T4LQ030TW||| |||40A (28-40A)|500|T4LQ040TW||| |||50A (35-50A)|500|T4LQ050TW||| ||kA|80A (56-80A)|400-800|T4LQ080TW||| ||65|100A (70-100A)|500-1000|T4LQ100TW||| |||125A (88-125A)|625-1250|T4LQ125TW||| |||150A (105-150A)|750-1500|T4LQ150TW||| |||200A (140-200A)|1000-2000|T4LQ200TW||| |||250A(175-250A)|1250-2500|T4LQ250TW||| |T4VQ||20A|500|T4VQ020TW||| |||30A (21-30A)|500|T4VQ030TW||| |||40A (28-40A)|500|T4VQ040TW||| |||50A (35-50A)|500|T4VQ050TW||| ||kA|80A (56-80A)|400-800|T4VQ080TW||| ||100|100A (70-100A)|500-1000|T4VQ100TW||| |||125A (88-125A)|625-1250|T4VQ125TW||| |||150A (105-150A)|750-1500|T4VQ150TW||| |||200A (140-200A)|1000-2000|T4VQ200TW||| |||250A(175-250A)|1250-2500|T4VQ250TW||| ABB 21 **Discount Schedule DS-ST** AC1615S - 03/10 **T4** ## **T4** 250A, 600VAC ∆ MCP (Instantaneous Only), Molded Case Switch ## **T4-250A Frame,** Motor Control Protection (MCP) Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip Unit Type|Rating|Adjustment<br>Range|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---| |T4N|||100A|100-1000|T4N100E5W|| ||18kA|PR221 DS-I|150A|150-1500|T4N150E5W|| ||||250A|250-2500|T4N250E5W|| |T4S|||100A|100-1000|T4S100E5W|| ||25kA|PR221 DS-I|150A|150-1500|T4S150E5W|| ||||250A|250-2500|T4S250E5W|| |T4H|||100A|100-1000|T4H100E5W|| ||35kA|PR221 DS-I|150A|150-1500|T4H150E5W|| ||||250A|250-2500|T4H250E5W|| |T4L|||100A|100-1000|T4L100E5W|| ||65kA|PR221 DS-I|150A|150-1500|T4L150E5W|| ||||250A|250-2500|T4L250E5W|| ## **T4-250A Frame,** Molded Case Switch |Type|Amps|Magnetic<br>Trip|3-Pole, 600VAC/600VDC<br>Part Number|List<br>Price|4-Pole, 600VAC/600VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---| |T4N-D<br>T4S-D<br>T4H-D<br>T4L-D<br>T4V-D|250|3000|T4N250DW|||| ||250|3000|T4S250DW|||| ||250|3000|T4H250DW||T4H250DW-4|| ||250|3000|T4L250DW|||| ||250|3000|T4V250DW|||| 22 ABB **Discount Schedule DS-ST** AC1615S - 03/10 **T5** 400A / 600A, 600VAC ∆ Electronic and Thermal-Magnetic **T5** **Dimensions** 3P Fixed Version 8.07H x 5.51W x 4.07D **Weight** 8.55 (Ibs) **==> picture [8 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> T5<br>**----- End of picture text -----**<br> ## **General** The T5 breaker is a 400/600 amp frame with either a microprocessor based over current protective trip system or a thermal magnetic trip unit.[(3)] ## **Standards** The UL489/CSA C22.2 No. 5 version of T5 also carries an IEC-60947-2 rating. ## **Versions** To meet all application requirements, the T5 is available in the following versions: ## **UL489 / CSA C22.2 Interrupting Capacity (kA RMS)** |Voltage|N|S|H|L|V| |---|---|---|---|---|---| |Voltage|N|S|H|L|V| |240VAC|65|100|150|200|200| |480VAC|25|35|65|100|150| |600VAC|18|25|35|65|100| |500VDC(1)|25|35|50|65|100| |600VDC(2)|16|25|35|50|65| - T = Thermal-magnetic - B = Selectable & adjustable LI or LS - C = Adjustable LSI ## **IEC 60947-2 Interrupting Capacity (kA RMS)** - E = Adjustable LSIG - D = Molded Case Switch - E5 = Electronic instantaneous only (MCP) ## **Trip Functions** These trip functions are available: - L = Long time - S = Short time - I = Instantaneous - G = Ground fault ## **Performance Levels** |Voltage|N|S|H|L|V| |---|---|---|---|---|---| |230VAC|70|85|100|200|200| |415VAC|36|50|70|120|200| |440VAC|30|40|65|100|180| |500VAC|25|30|50|85|150| |690VAC|20|25|40|70|80| |750VDC(2)|16|25|36|50|70| Each version is also available in different maximum fault interrupting levels: - N = Normal - S = Standard - H = High - L = Extra high - V = Very high ## **Number of Poles[(4)]** The T5 is available as a 2, 3 and 4 pole breaker. The 2 and 3 pole versions have the same dimensions. ## **Reverse Feeding** All versions of the T5 family are suitable for reverse feed application. > (1) 2 poles in series. > (2) 3 poles in series. > (3) T5 600A not available with thermal magnetic trip unit. > (4) 2 pole available in N version only. 4 pole available in N and H version only. ABB 23 AC1615S - 03/10 **T5** ## **T5** 400A / 600A Electronic (AC Only) ## **T5-300A Frame,** Electronic Trip Unit (AC Only) 120-300A Adjustable Range |Breaker|IC at<br>600VAC|Trip<br>Unit|2-Pole, 600VAC<br>Part Number|List<br>Price|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---|---| |T5N||PR221 LS/I|T5N300BW-2||T5N300BW||T5N300BW-4|| ||18kA|PR222 LSI|T5N300CW-2||T5N300CW||T5N300CW-4|| |||PR222 LSIG|T5N300EW-2||T5N300EW||T5N300EW-4|| |T5S||PR221 LS/I|||T5S300BW|||| ||25kA|PR222 LSI|||T5S300CW|||| |||PR222 LSIG|||T5S300EW|||| |T5H||PR221 LS/I|||T5H300BW||T5H300BW-4|| ||35kA|PR222 LSI|||T5H300CW||T5H300CW-4|| |||PR222 LSIG|||T5H300EW||T5H300EW-4|| |T5L||PR221 LS/I|||T5L300BW|||| ||65kA|PR222 LSI|||T5L300CW|||| |||PR222 LSIG|||T5L300EW|||| |T5V||PR221 LS/I|||T5V300BW|||| ||100kA|PR222 LSI|||T5V300CW|||| |||PR222 LSIG|||T5V300EW|||| ## **T5-400A Frame,** Electronic Trip Unit (AC Only) 160-400A Adjustable Range |Breaker|IC at<br>600VAC|Trip<br>Unit|2-Pole, 600VAC<br>Part Number|List<br>Price|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---|---| |T5N||PR221 LS/I|T5N400BW-2||T5N400BW||T5N400BW-4|| ||18kA|PR222 LSI|T5N400CW-2||T5N400CW||T5N400CW-4|| |||PR222 LSIG|T5N400EW-2||T5N400EW||T5N400EW-4|| |T5S||PR221 LS/I|||T5S400BW|||| ||25kA|PR222 LSI|||T5S400CW|||| |||PR222 LSIG|||T5S400EW|||| |T5H||PR221 LS/I|||T5H400BW||T5H400BW-4|| ||35kA|PR222 LSI|||T5H400CW||T5H400CW-4|| |||PR222 LSIG|||T5H400EW||T5H400EW-4|| |T5L||PR221 LS/I|||T5L400BW|||| ||65kA|PR222 LSI|||T5L400CW|||| |||PR222 LSIG|||T5L400EW|||| |T5V||PR221 LS/I|||T5V400BW|||| ||100kA|PR222 LSI|||T5V400CW|||| |||PR222 LSIG|||T5V400EW|||| ## **T5-600A Frame,** Electronic Trip Unit (AC Only) 240-600A Adjustable Range |Breaker|IC at<br>600VAC|Trip<br>Unit|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---| |T5N||PR221 LS/I|T5N600BW|| ||18kA|PR222 LSI|T5N600CW|| |||PR222 LSIG|T5N600EW|| |T5S||PR221 LS/I|T5S600BW|| ||25kA|PR222 LSI|T5S600CW|| |||PR222 LSIG|T5S600EW|| |T5H||PR221 LS/I|T5H600BW|| ||35kA|PR222 LSI|T5H600CW|| |||PR222 LSIG|T5H600EW|| |T5L||PR221 LS/I|T5L600BW|| ||65kA|PR222 LSI|T5L600CW|| |||PR222 LSIG|T5L600EW|| |T5V||PR221 LS/I|T5V600BW|| ||100kA|PR222 LSI|T5V600CW|| |||PR222 LSIG|T5V600EW|| 24 ABB **Discount Schedule DS-ST** AC1615S - 03/10 **T5** 400A 100% Rated Electronic (AC only)[(1)] **T5** ## **T5-300A Frame,** 100% Rated Electronic Trip Units (AC Only) 120-300A Adjustable Range |Breaker|IC at<br>600VAC|Trip<br>Unit|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---| |T5N||PR221 LS/I|T5NQ300BW|| ||18kA|PR222 LSI|T5NQ300CW|| |||PR222 LSIG|T5NQ300EW|| |T5S||PR221 LS/I|T5SQ300BW|| ||25kA|PR222 LSI|T5SQ300CW|| |||PR222 LSIG|T5SQ300EW|| |T5H||PR221 LS/I|T5HQ300BW|| ||35kA|PR222 LSI|T5HQ300CW|| |||PR222 LSIG|T5HQ300EW|| |T5L||PR221 LS/I|T5LQ300BW|| ||65kA|PR222 LSI|T5LQ300CW|| |||PR222 LSIG|T5LQ300EW|| |T5V||PR221 LS/I|T5VQ300BW|| ||100kA|PR222 LSI|T5VQ300CW|| |||PR222 LSIG|T5VQ300EW|| ## **T5-400A Frame,** 100% Rated Electronic Trip Units (AC Only) 160-400A Adjustable Range |Breaker|IC at<br>600VAC|Trip<br>Unit|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---| |T5N||PR221 LS/I|T5NQ400BW|| ||18kA|PR222 LSI|T5NQ400CW|| |||PR222 LSIG|T5NQ400EW|| |T5S||PR221 LS/I|T5SQ400BW|| ||25kA|PR222 LSI|T5SQ400CW|| |||PR222 LSIG|T5SQ400EW|| |T5H||PR221 LS/I|T5HQ400BW|| ||35kA|PR222 LSI|T5HQ400CW|| |||PR222 LSIG|T5HQ400EW|| |T5L||PR221 LS/I|T5LQ400BW|| ||65kA|PR222 LSI|T5LQ400CW|| |||PR222 LSIG|T5LQ400EW|| |T5V||PR221 LS/I|T5VQ400BW|| ||100kA|PR222 LSI|T5VQ400CW|| |||PR222 LSIG|T5VQ400EW|| (1) T5 600A not available as 100% rated ABB 25 **Discount Schedule DS-ST** AC1615S - 03/10 **T5** ## **T5** 400A, 600VAC ∆ Thermal-Magnetic[(1)] ## **T5-300/400A Frame,** Thermal-Magnetic Trip Unit |Breaker|IC at<br>600VAC|Rating|Magnetic<br>Trip|2-Pole, 600VAC/500VDC<br>Part Number|List<br>Price|3-Pole, 600VAC/600VDC<br>Part Number|List<br>Price|4-Pole, 600VAC/600VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---|---|---| |T5N|18kA|300A|1500-3000|T5N300TW-2||T5N300TW||T5N300TW-4|| |||400A|2000-4000|T5N400TW-2||T5N400TW||T5N400TW-4|| |T5S|25kA|300A|1500-3000|||T5S300TW||T5S300TW-4|| |||400A|2000-4000|||T5S400TW||T5S400TW-4|| |T5H|35kA|300A|1500-3000|||T5H300TW||T5H300TW-4|| |||400A|2000-4000|||T5H400TW||T5H400TW-4|| |T5L|65kA|300A|1500-3000|||T5L300TW||T5L300TW-4|| |||400A|2000-4000|||T5L400TW||T5L400TW-4|| |T5V|100kA|300A|1500-3000|||T5V300TW||T5V300TW-4|| |||400A|2000-4000|||T5V400TW||T5V400TW-4|| ## **T5-300/400A Frames,** 100% Rated, Thermal-Magnetic Trip Unit |Breaker|IC at<br>600VAC|Rating|Magnetic<br>Trip|3-Pole, 600VAC/500VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T5N|18kA|300A|1500-3000|T5NQ300TW|| |||400A|2000-4000|T5NQ400TW|| |T5S|25kA|300A|1500-3000|T5SQ300TW|| |||400A|2000-4000|T5SQ400TW|| |T5H|35kA|300A|1500-3000|T5HQ300TW|| |||400A|2000-4000|T5HQ400TW|| |T5L|65kA|300A|1500-3000|T5LQ300TW|| |||400A|2000-4000|T5LQ400TW|| |T5V|100kA|300A|1500-3000|T5VQ300TW|| |||400A|2000-4000|T5VQ400TW|| (1) T5 600A not available with thermal-magnetic trip unit. 26 ABB **Discount Schedule DS-ST** AC1615S - 03/10 **T5** ## **T5** 400A / 600A MCP (Instantaneous Only), Molded Case Switch ## **T5-300/400A Frame,** Motor Control Protection (MCP) Electronic Trip Unit (Ac Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Rating|Adjustment<br>Range|3-Pole, 600VAC/600VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---| |T5N|||300A|300-3000|T5N300E5W|| ||18kA|PR221DS-I|400A|400-4000|T5N400E5W|| |T5S|2kA|PR22DSI|300A|300-3000|T5S300E5W|| ||5|1-|400A|400-4000|T5S400E5W|| |T5H|||300A|300-3000|T5H300E5W|| ||55kA|PR221DS-I|400A|400-4000|T5H400E5W|| |T5L|||300A|300-3000|T5L300E5W|| ||65kA|PR221DS-I|400A|400-4000|T5L400E5W|| ## **T5-600A Frame,** Motor Control Protection (MCP) Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Rating|Adjustment<br>Range|3-Pole, 600VAC/600VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---| |T5N|18kA|PR221DS-I|600A|600-6000|T5N600E5W|| |T5S|25kA|PR221DS-I|600A|600-6000|T5S600E5W|| |T5H|55kA|PR221DS-I|600A|600-6000|T5H600E5W|| |T5L|65kA|PR221DS-I|600A|600-6000|T5L600E5W|| ## **T5-400/600A Frame,** Molded Case Switch ||Type|IC at<br>600VAC|Amps|Magnetic<br>Trip|3-Pole, 600VAC/600VDC<br>Part Number|List<br>Price|4-Pole, 600VAC/600VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---|---| ||T5N-D<br>T5S-D<br>T5H-D<br>T5L-D<br>T5V-D|18kA|400|5000|T5N400DW|||| |||25kA|400|5000|T5S400DW|||| |||35kA|400|5000|T5H400DW||T5H400DW-4|| |||65kA|400|5000|T5L400DW|||| |||100kA|400|5000|T5V400DW|||| ||T5N-D<br>T5S-D<br>T5H-D<br>T5L-D<br>T5V-D|18kA|600|6000|T5N600DW|||| |||25kA|600|6000|T5S600DW|||| |||35kA|600|6000|T5H600DW|||| |||65kA|600|6000|T5L600DW|||| |||100kA|600|6000|T5V600DW|||| ABB 27 **Discount Schedule DS-ST** AC1615S - 03/10 **T6 T6** 600A / 800A, 600VAC ∆ Electronic & Thermal-Magnetic **Dimensions** 3P Fixed Version 10.55H x 8.26W x 4.07D **Weight** 20.9 (Ibs) T6 ~~ee~~ **General UL489 / CSA C22.2 Interrupting Capacity (kA RMS)** The T6 breaker is an 800 amp frame with either a microprocessor based over current protective trip system or a thermal magnetic trip unit. The T6 is Voltage N S H L available as a 600 or 800A frame. 240VAC 65 100 200 200 **Standards** 480VAC 35 50 65 100 The UL489/CSA C22.2 No. 5 version of T6 also carries an IEC-60947-2 rating. 600VAC 20 25 35 42 **Versions** 500VDC[(1)] 35 35 50 65 To meet all application requirements, the T6 is available in the following 600VDC[(2)] 20 20 35 50 === ~~==5~~ versions: T = Thermal-magnetic, fi xed B = Selectable & adjustable LI or LS C = Adjustable LSI **IEC 60947-2 Interrupting Capacity (kA RMS)** E = Adjustable LSIG D = Molded Case Switch Voltage N S H L E5 = Electronic instantaneous only (MCP) 230VAC 70 85 100 200 **Trip Functions** 415VAC 36 50 70 100 These trip functions are available: 600VAC 20 22 25 30 L = Long time S = Short time 750VDC[(2)] 16 20 36 50 = ~~=~~ - I = Instantaneous - G = Ground fault ## **Performance Levels** Each version is also available in different maximum fault interrupting levels: - N = Normal - S = Standard - H = High - L = Extra high ## **Number of Poles[(3)]** The T6 is available as a 3 and 4 pole breaker. - 4 poles only available in N or H version. ## **Reverse Feeding** All versions of the T6 family are suitable for reverse feed application. - (1) 2 poles in series. > (2) 3 poles in series. (3) 4 pole available N and H version only. 28 ABB AC1615S - 03/10 **T6** ## **T6** 600A / 800A, 600VAC ∆ Electronic (AC Only) ## **T6-600A Frame,** Electronic Trip Unit (AC Only) 240-600A Adjustable Range |Breaker|IC at<br>600VAC|Trip<br>Unit|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---| |T6N||PR221 LS/I|T6N600BW||T6N600BW-4|| ||20kA|PR222 LSI|T6N600CW||T6N600CW-4|| |||PR222 LSIG|T6N600EW||T6N600EW-4|| |T6S||PR221 LS/I|T6S600BW|||| ||25kA|PR222 LSI|T6S600CW|||| |||PR222 LSIG|T6S600EW|||| |T6H||PR221 LS/I|T6H600BW||T6H600BW-4|| ||35kA|PR222 LSI|T6H600CW||T6H600CW-4|| |||PR222 LSIG|T6H600EW||T6H600EW-4|| |T6L||PR221 LS/I|T6L600BW|||| ||42kA|PR222 LSI|T6L600CW|||| |||PR222 LSIG|T6L600EW|||| ## **T6-800A Frame,** Electronic Trip Unit (AC Only) 320-800A Adjustable Range |Breaker|IC at<br>600VAC|Trip<br>Unit|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---| |T6N||PR221 LS/I|T6N800BW||T6N800BW-4|| ||20kA|PR222 LSI|T6N800CW||T6N800CW-4|| |||PR222 LSIG|T6N800EW||T6N800EW-4|| |T6S||PR221 LS/I|T6S800BW|||| ||25kA|PR222 LSI|T6S800CW|||| |||PR222 LSIG|T6S800EW|||| |T6H||PR221 LS/I|T6H800BW||T6H800BW-4|| ||35kA|PR222 LSI|T6H800CW||T6H800CW-4|| |||PR222 LSIG|T6H800EW||T6H800EW-4|| |T6L||PR221 LS/I|T6L800BW|||| ||42kA|PR222 LSI|T6L800CW|||| |||PR222 LSIG|T6L800EW|||| ## **T6-600A Frame,** 100% Rated Electronic Trip Unit (AC Only) 240-600A Adjustable Range |Breaker|IC at<br>600VAC|Trip<br>Unit|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---| |T6N||PR221 LS/I|T6NQ600BW|| ||20kA|PR222 LSI|T6NQ600CW|| |||PR222 LSIG|T6NQ600EW|| |T6S||PR221 LS/I|T6SQ600BW|| ||25kA|PR222 LSI|T6SQ600CW|| |||PR222 LSIG|T6SQ600EW|| |T6H||PR221 LS/I|T6HQ600BW|| ||35kA|PR222 LSI|T6HQ600CW|| |||PR222 LSIG|T6HQ600EW|| |T6L||PR221 LS/I|T6LQ600BW|| ||42kA|PR222 LSI|T6LQ600CW|| |||PR222 LSIG|T6LQ600EW|| ## **T6-800A Frame,** 100% Rated Electronic Trip Unit (AC Only) 320-800A Adjustable Range |Breaker|IC at<br>600VAC|Trip<br>Unit|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---| |T6N||PR221 LS/I|T6NQ800BW|| ||20kA|PR222 LSI|T6NQ800CW|| |||PR222 LSIG|T6NQ800EW|| |T6S||PR221 LS/I|T6SQ800BW|| ||25kA|PR222 LS/I|T6SQ800CW|| |||PR222 LSIG|T6SQ800EW|| |T6H||PR221 LS/I|T6HQ800BW|| ||35kA|PR222 LSI|T6HQ800CW|| |||PR222 LSIG|T6HQ800EW|| |T6L||PR221 LS/I|T6LQ800BW|| ||42kA|PR222 LSI|T6LQ800CW|| |||PR222 LSIG|T6LQ800EW|| ABB 29 **Discount Schedule DS-ST** AC1615S - 03/10 **T6** ## **T6** 600A / 800A, 600VAC ∆ Electronic & Thermal-Magnetic ## **T6-600/800A Frame,** Thermal-Magnetic Trip Unit |Breaker|IC at<br>600VAC|Rating|Magnetic Trip|3-Pole, 600VAC/600VDC<br>Part Number|List<br>Price|4-Pole, 600VAC/600VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T6N|20kA|600A|3000 - 6000A|T6N600TW||T6N600TW-4|| |||800A|4000 - 8000A|T6N800TW||T6N800TW-4|| |T6S|25kA|600A|3000 - 6000A|T6S600TW|||| |||800A|4000 - 8000A|T6S800TW|||| |T6H|35kA|600A|3000 - 6000A|T6H600TW||T6H600TW-4|| |||800A|4000 - 8000A|T6H800TW||T6H800TW-4|| |T6L|42kA|600A|3000 - 6000A|T6L600TW|||| |||800A|4000 - 8000A|T6L800TW|||| ## **T6-600/800A Frame,** 100% Rated Thermal-Magnetic Trip Unit |Breaker|IC at<br>600VAC|Rating|Magnetic Trip|3-Pole, 600VAC/600VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T6N|2kA|600A|3000 - 6000A|T6NQ600TW|| ||0|800A|4000-8000A|T6NQ800TW|| |T6S|2kA|600A|3000 - 6000A|T6SQ600TW|| ||5|800A|4000-8000A|T6SQ800TW|| |T6H|kA|600A|3000 - 6000A|T6HQ600TW|| ||35|800A|4000-8000A|T6HQ800TW|| |T6L|2kA|600A|3000 - 6000A|T6LQ600TW|| ||4|800A|4000 - 8000A|T6LQ800TW|| **T6-600A Frame,** Motor Control Protection (MCP) Electronic Trip Unit (AC Only) |Only)|||||| |---|---|---|---|---|---| ||||||| |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment Range|3-Pole, 600VAC<br>Part Number|List<br>Price| |T6N<br>T6S<br>T6H<br>T6L|20kA|PR221 DS-I|600-6000|T6N600E5W|| ||25kA|PR221 DS-I|600-6000|T6S600E5W|| ||35kA|PR221 DS-I|600-6000|T6H600E5W|| ||42kA|PR221 DS-I|600-6000|T6L600E5W|| **T6-800A Frame,** Motor Control Protection (MCP) Electronic Trip Unit (AC Only) |Only)|||||| |---|---|---|---|---|---| |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment Range|3-Pole, 600VAC<br>Part Number|List<br>Price| |T6N<br>T6S<br>T6H<br>T6L|20kA|PR221 DS-I|800-8000|T6N800E5W|| ||25kA|PR221 DS-I|800-8000|T6S800E5W|| ||35kA|PR221 DS-I|800-8000|T6H800E5W|| ||42kA|PR221 DS-I|800-8000|T6L800E5W|| ## **T6-800A Frame,** Molded Case Switch |Breaker|IC at<br>600VAC|Amp|Magnetic Trip|3-Pole, 600VAC/600VDC<br>Part Number|List<br>Price|4-Pole, 600VAC/600VDC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T6H|35kA|800|10,000|T6H800DW||T6H800DW-4|| 30 ABB **Discount Schedule DS-ST** AC1615S - 03/10 **T7** ## **T7-T7M** 1000A / 1200A, 600VAC ∆ Electronic (AC Only) **Dimensions** 3P Fixed Version 10.55H x 8.26W x 6.07D[(1)] **Weight** 21.4 (Ibs) **==> picture [8 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> T7<br>**----- End of picture text -----**<br> ## **General** The T7 breaker is a 1200 amp frame with a microprocessor based over current protective trip system. Available in 2 versions: T7 for toggle operated, T7M for motor operated ## **Standards** The UL489/CSA C22.2 No. 5 version of T7 also carries an IEC-60947-2 rating. ## **Versions** To meet all application requirements, the T7 is available in the following versions: - B = PR231-LS/I adjustable (dip switch) - C = PR232-LSI adjustable (dip switch) - E = PR331-LSIG adjustable (dip switch) - D = Moulded Case Switch - P = PR332-LI adjustable (keypad + LCD display) - R = PR332-LSI adjustable (keypad + LCD display) - S = PR332-LSIG adjustable (keypad + LCD display) **UL489 / CSA C22.2 Interrupting Capacity (kA RMS)** > Voltage S H L 240VAC 65 100 150 480VAC 50 65 100 600VAC 25 50 65 —— ~~——~~ **IEC 60947-2 Interrupting Capacity (kA RMS)** > Voltage S H L 230VAC 85 100 200 415VAC 50 70 120 690VAC 30 42 50 —— ~~——~~ ## **Trip Functions** These trip functions are available: L = Long time - S = Short time - I = Instantaneous - G = Ground fault ## **Performance Levels** Each version is also available in different maximum fault interrupting levels: - S = Standard - H = High - L = Extra high ## **Number of Poles** The T7 is available as a 3 and 4 pole breaker. (1) Toggle type (dimensions of toggle not included) ABB 31 AC1615S - 03/10 **T7** ## **T7** 1000A / 1200A, 600VAC ∆ Electronic (AC Only) ## **T7S-1000A Frame,** Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T7S||PR231/P|LS/I|T7S1000BW||T7S1000BW-4|| |||PR232/P|LSI|T7S1000CW||T7S1000CW-4|| ||25kA|PR331/P|LSIG|T7S1000EW||T7S1000EW-4|| |||PR332/P|LI|T7S1000PW||T7S1000PW-4|| |||PR332/P|LSI|T7S1000RW||T7S1000RW-4|| |||PR332/P|LSIG|T7S1000SW||T7S1000SW-4|| |**T7S-1200A Frame,**Electronic Trip Unit (AC Only)|||||||| |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |T7S||PR231/P|LS/I|T7S1200BW||T7S1200BW-4|| |||PR232/P|LSI|T7S1200CW||T7S1200CW-4|| |||PR331/P|LSIG|T7S1200EW||T7S1200EW-4|| ||25kA|PR332/P|LI|T7S1200PW||T7S1200PW-4|| |||PR332/P|LSI|T7S1200RW||T7S1200RW-4|| |||PR332/P|LSIG|T7S1200SW||T7S1200SW-4|| |**T7H-1000A Frame,**Electronic Trip Unit (AC Only)|||||||| |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |T7H||PR231/P|LS/I|T7H1000BW||T7H1000BW-4|| |||PR232/P|LSI|T7H1000CW||T7H1000CW-4|| |||PR331/P|LSIG|T7H1000EW||T7H1000EW-4|| ||50kA|PR332/P|LI|T7H1000PW||T7H1000PW-4|| |||PR332/P|LSI|T7H1000RW||T7H1000RW-4|| |||PR332/P|LSIG|T7H1000SW||T7H1000SW-4|| |**T7H-1200A Frame,**Electronic Trip Unit (AC Only)|||||||| |<br>Breaker|<br>IC at<br>600VAC|<br>Trip<br>Unit|<br>Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |T7H||PR231/P|LS/I|T7H1200BW||T7H1200BW-4|| |||PR232/P|LSI|T7H1200CW||T7H1200CW-4|| |||PR331/P|LSIG|T7H1200EW||T7H1200EW-4|| ||50kA|PR332/P|LI|T7H1200PW||T7H1200PW-4|| |||PR332/P|LSI|T7H1200RW||T7H1200RW-4|| |||PR332/P|LSIG|T7H1200SW||T7H1200SW-4|| |**T7L-1000A Frame,**Electronic Trip Unit (AC Only)|||||||| |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |T7L||PR231/P|LS/I|T7L1000BW||T7L1000BW-4|| |||PR232/P|LSI|T7L1000CW||T7L1000CW-4|| |||PR331/P|LSIG|T7L1000EW||T7L1000EW-4|| ||65kA|PR332/P|LI|T7L1000PW||T7L1000PW-4|| |||PR332/P|LSI|T7L1000RW||T7L1000RW-4|| |||PR332/P|LSIG|T7L1000SW||T7L1000SW-4|| ## **T7L-1200A Frame,** Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T7L||PR231/P|LS/I|T7L1200BW||T7L1200BW-4|| |||PR232/P|LSI|T7L1200CW||T7L1200CW-4|| |||PR331/P|LSIG|T7L1200EW||T7L1200EW-4|| ||65kA|PR332/P|LI|T7L1200PW||T7L1200PW-4|| |||PR332/P|LSI|T7L1200RW||T7L1200RW-4|| |||PR332/P|LSIG|T7L1200SW||T7L1200SW-4|| 32 ABB **Discount Schedule DS-ST** AC1615S - 03/10 **T7** ## **T7M** 1000A / 1200A, 600VAC ∆ Electronic (AC Only) ## **T7MS-1000A Frame,** Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T7MS||PR231/P|LS/I|T7MS1000BW||T7MS1000BW-4|| |||PR232/P|LSI|T7MS1000CW||T7MS1000CW-4|| |||PR331/P|LSIG|T7MS1000EW||T7MS1000EW-4|| ||25kA|PR332/P|LI|T7MS1000PW||T7MS1000PW-4|| |||PR332/P|LSI|T7MS1000RW||T7MS1000RW-4|| |||PR332/P|LSIG|T7MS1000SW||T7MS1000SW-4|| ## **T7MS-1200A Frame,** Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T7MS||PR231/P|LS/I|T7MS1200BW||T7MS1200BW-4|| |||PR232/P|LSI|T7MS1200CW||T7MS1200CW-4|| |||PR331/P|LSIG|T7MS1200EW||T7MS1200EW-4|| ||25kA|PR332/P|LI|T7MS1200PW||T7MS1200PW-4|| |||PR332/P|LSI|T7MS1200RW||T7MS1200RW-4|| |||PR332/P|LSIG|T7MS1200SW||T7MS1200SW-4|| ## **T7MH, 1000A Frame,** Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T7MH||PR231/P|LS/I|T7MH1000BW||T7MH1000BW-4|| |||PR232/P|LSI|T7MH1000CW||T7MH1000CW-4|| |||PR331/P|LSIG|T7MH1000EW||T7MH1000EW-4|| ||50kA|PR332/P|LI|T7MH1000PW||T7MH1000PW-4|| |||PR232/P|LSI|T7MH1000RW||T7MH1000RW-4|| |||PR332/P|LSIG|T7MH1000SW||T7MH1000SW-4|| ## **T7MH-1200A Frame,** Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T7MH||PR231/P|LS/I|T7MH1200BW||T7MH1200BW-4|| |||PR232/P|LSI|T7MH1200CW||T7MH1200CW-4|| |||PR331/P|LSIG|T7MH1200EW||T7MH1200EW-4|| ||50kA|PR332/P|LI|T7MH1200PW||T7MH1200PW-4|| |||PR332/P|LSI|T7MH1200RW||T7MH1200RW-4|| |||PR332/P|LSIG|T7MH1200SW||T7MH1200SW-4|| ## **T7ML-1000A Frame,** Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T7ML||PR231/P|LS/I|T7ML1000BW||T7ML1000BW-4|| |||PR232/P|LSI|T7ML1000CW||T7ML1000CW-4|| |||PR331/P|LSIG|T7ML1000EW||T7ML1000EW-4|| ||65kA|PR332/P|LI|T7ML1000PW||T7ML1000PW-4|| |||PR332/P|LSI|T7ML1000RW||T7ML1000RW-4|| |||PR332/P|LSIG|T7ML1000SW||T7ML1000SW-4|| ## **T7ML-1200A Frame,** Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T7ML||PR231/P|LS/I|T7ML1200BW||T7ML1200BW-4|| |||PR232/P|LSI|T7ML1200CW||T7ML1200CW-4|| |||PR331/P|LSIG|T7ML1200EW||T7ML1200EW-4|| ||65kA|PR332/P|LI|T7ML1200PW||T7ML1200PW-4|| |||PR332/P|LSI|T7ML1200RW||T7ML1200RW-4|| |||PR332/P|LSIG|T7ML1200SW||T7ML1200SW-4|| ABB 33 **Discount Schedule DS-ST** AC1615S - 03/10 **T7** ## **T7** 1000A / 1200A, 600VAC ∆ 100% Rated Electronic (AC Only) ## **T7S-1000A Frame,** 100% Rated Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T7SQ||PR231/P|LS/I|T7SQ1000BW|| |||PR232/P|LSI|T7SQ1000CW|| |||PR331/P|LSIG|T7SQ1000EW|| ||25kA|PR332/P|LI|T7SQ1000PW|| |||PR332/P|LSI|T7SQ1000RW|| |||PR332/P|LSIG|T7SQ1000SW|| ## **T7S-1200A Frame,** 100% Rated Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T7SQ||PR231/P|LS/I|T7SQ1200BW|| |||PR232/P|LSI|T7SQ1200CW|| |||PR331/P|LSIG|T7SQ1200EW|| ||25kA|PR332/P|LI|T7SQ1200PW|| |||PR332/P|LSI|T7SQ1200RW|| |||PR332/P|LSIG|T7SQ1200SW|| ## **T7H-1000A Frame,** 100% Rated Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T7HQ||PR231/P|LS/I|T7HQ1000BW|| |||PR232/P|LSI|T7HQ1000CW|| |||PR331/P|LSIG|T7HQ1000EW|| ||50kA|PR332/P|LI|T7HQ1000PW|| |||PR332/P|LSI|T7HQ1000RW|| |||PR332/P|LSIG|T7HQ1000SW|| ## **T7H-1200A Frame,** 100% Rated Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T7HQ||PR231/P|LS/I|T7HQ1200BW|| |||PR232/P|LSI|T7HQ1200CW|| |||PR331/P|LSIG|T7HQ1200EW|| ||50kA|PR332/P|LI|T7HQ1200PW|| |||PR332/P|LSI|T7HQ1200RW|| |||PR332/P|LSIG|T7HQ1200SW|| ## **T7L-1000A Frame,** 100% Rated Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T7LQ||PR231/P|LS/I|T7LQ1000BW|| |||PR232/P|LSI|T7LQ1000CW|| |||PR331/P|LSIG|T7LQ1000EW|| ||65kA|PR332/P|LI|T7LQ1000PW|| |||PR332/P|LSI|T7LQ1000RW|| |||PR332/P|LSIG|T7LQ1000SW|| ## **T7L-1200A Frame,** 100% Rated Electronic Trip Unit (AC Only) ||Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---| ||T7LQ||PR231/P|LS/I|T7LQ1200BW|| ||||PR232/P|LSI|T7LQ1200CW|| ||||PR331/P|LSIG|T7LQ1200EW|| |||65kA|PR332/P|LI|T7LQ1200PW|| ||||PR332/P|LSI|T7LQ1200RW|| ||||PR332/P|LSIG|T7LQ1200SW|| 34 ABB **Discount Schedule DS-ST** AC1615S - 03/10 **T7** ## **T7M** 1000A / 1200A, 600VAC ∆ 100% Rated Electronic (AC Only) ## **T7MS-1000A Frame,** 100% Rated Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T7MSQ||PR231/P|LS/I|T7MSQ1000BW|| |||PR232/P|LSI|T7MSQ1000CW|| |||PR331/P|LSIG|T7MSQ1000EW|| ||25kA|PR332/P|LI|T7MSQ1000PW|| |||PR332/P|LSI|T7MSQ1000RW|| |||PR332/P|LSIG|T7MSQ1000SW|| ## **T7MS-1200A Frame,** 100% Rated Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T7MSQ||PR231/P|LS/I|T7MSQ1200BW|| |||PR232/P|LSI|T7MSQ1200CW|| |||PR331/P|LSIG|T7MSQ1200EW|| ||25kA|PR332/P|LI|T7MSQ1200PW|| |||PR332/P|LSI|T7MSQ1200RW|| |||PR332/P|LSIG|T7MSQ1200SW|| ## **T7MH-1000A Frame,** 100% Rated Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T7MHQ||PR231/P|LS/I|T7MHQ1000BW|| |||PR232/P|LSI|T7MHQ1000CW|| |||PR331/P|LSIG|T7MHQ1000EW|| ||50kA|PR332/P|LI|T7MHQ1000PW|| |||PR332/P|LSI|T7MHQ1000RW|| |||PR332/P|LSIG|T7MHQ1000SW|| ## **T7MH-1200A Frame,** 100% Rated Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T7MHQ||PR231/P|LS/I|T7MHQ1200BW|| |||PR232/P|LSI|T7MHQ1200CW|| |||PR331/P|LSIG|T7MHQ1200EW|| ||50kA|PR332/P|LI|T7MHQ1200PW|| |||PR332/P|LSI|T7MHQ1200RW|| |||PR332/P|LSIG|T7MHQ1200SW|| ## **T7ML-1000A Frame,** 100% Rated Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T7MLQ||PR231/P|LS/I|T7MLQ1000BW|| |||PR232/P|LSI|T7MLQ1000CW|| |||PR331/P|LSIG|T7MLQ1000EW|| ||65kA|PR332/P|LI|T7MLQ1000PW|| |||PR332/P|LSI|T7MLQ1000RW|| |||PR332/P|LSIG|T7MLQ1000SW|| ## **T7ML-1200A Frame,** 100% Rated Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T7MLQ||PR231/P|LS/I|T7MLQ1200BW|| |||PR232/P|LSI|T7MLQ1200CW|| |||PR331/P|LSIG|T7MLQ1200EW|| ||65kA|PR332/P|LI|T7MLQ1200PW|| |||PR332/P|LSI|T7MLQ1200RW|| |||PR332/P|LSIG|T7MLQ1200SW|| ABB 35 **Discount Schedule DS-ST** AC1615S - 03/10 **T7** ## **T7-T7M** 1000A / 1200A, 600VAC ∆ MCP (Instantaneous Only), Molded Case Switch ## **T7-1000/1200A Frame,** Motor Control Protection (MCP) Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Amps|Trip<br>Unit|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T7|25kA|1000|PR231/P-I|T7S1000MW|| ||50kA|1000|PR231/P-I|T7H1000MW|| ||65kA|1000|PR231/P-I|T7L1000MW|| ||25kA|1200|PR231/P-I|T7S1200MW|| ||50kA|1200|PR231/P-I|T7H1200MW|| ||65kA|1200|PR231/P-I|T7L1200MW|| ## **T7M-1000/1200A Frame,** Motor Control Protection (MCP) Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Amps|Trip<br>Unit|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T7M|25kA|1000|PR231/P-I|T7MS1000MW|| ||50kA|1000|PR231/P-I|T7MH1000MW|| ||65kA|1000|PR231/P-I|T7ML1000MW|| ||25kA|1200|PR231/P-I|T7MS1200MW|| ||50kA|1200|PR231/P-I|T7MH1200MW|| ||65kA|1200|PR231/P-I|T7ML1200MW|| ## **T7/T7M-1200A Frame,** Molded Case Switch (AC Only) |Breaker|IC at<br>600VAC|Amps|Magnetic<br>Trip|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T7<br>T7M|50kA|1200|12000|T7H1200DW||T7H1200DW-4|| ||50kA|1200|12000|T7MH1200DW||T7MH1200DW-4|| ABB 36 **Discount Schedule DS-ST** AC1615S - 03/10 **T7** ## **T7-T7M** 1000A / 1200A, 600VAC ∆ Accessories ## **Shunt Trips (YO)** T7 X1 Shunt trip - UVR |Frame Size|Voltage|Part<br>Number|List<br>Price| |---|---|---|---| |T7 - T7M|415-440VAC<br>380-400VAC<br>240-250VAC/DC<br>220-240VAC/DC<br>120-127VAC/DC<br>110-120VAC/DC<br>60VAC/DC<br>48VAC/DC<br>30VAC/DC<br>24VAC/DC|KT7XS1<br>KT7XS2<br>KT7XS3<br>KT7XS4<br>KT7XS5<br>KT7XS6<br>KT7XS7<br>KT7XS8<br>KT7XS9<br>KT7XS0|| **Undervoltage Release - (UVR)** Part List Frame Size Voltage Number Price 415-440VAC KT7XU1 380-400VAC KT7XU2 240-250VAC/DC KT7XU3 220-240VAC/DC KT7XU4 120-127VAC/DC KT7XU5 T7 - T7M 110-120VAC/DC KT7XU6 60VAC/DC KT7XU7 48VAC/DC KT7XU8 30VAC/DC KT7XU9 ~~cm~~ 24VAC/DC KT7XU0 **Shunt Closing Release (YC)** Part List Frame Size Voltage Number Price 415-440VAC KT7MXC1 380-400VAC KT7MXC2 240-250VAC/DC KT7MXC3 220-240VAC/DC KT7MXC4 120-127VAC/DC KT7MXC5 T7M 110-120VAC/DC KT7MXC6 60VAC/DC KT7MXC7 48VAC/DC KT7MXC8 30VAC/DC KT7MXC9 ~~|~~ 24VAC/DC KT7MXC0 **Auxiliary Contacts - (AUX)** Part List Frame Size Type / Voltage Number Price Possible combinations are: 1 AUX "C" + 1 BA "C" 400VAC KT7AS[(1)] 2 AUX "C" 400VAC KT7XAS2 T7: a) 1 Aux + 1BA b) 2 Aux, 1 AUX "C" + 1 BA "C" 24VDC KT7ASL[(1)] c) 3 Aux + 1BA T7-T7M 2 AUX "C" 24VDC KT7XAS2L T7M: a) 2 Aux , b) 4 Aux 1 S51"C" 250VAC KT7XS51[(2)] 1 S51"C" 250VAC KT7S51[(1)] ~~a=~~ **Spring Charging Motor (M)** Part List Frame Size Type / Voltage Number Price 380...415VAC KT7MXM2 220...250VAC/DC KT7MXM3 T7M 100/130VAC/DC KT7MXM5 48...60VAC/DC KT7MXM7 ~~oe~~ 24...30VAC/DC KT7MXM9 (1) For installation on T7 only (2) For installation on T7M only ABB 37 **Discount Schedule DS-STA** AC1615S - 03/10 **T7-T7M** 1000A / 1200A, 600VAC ∆ Accessories **T7** **==> picture [126 x 647] intentionally omitted <==** ## **Standard Cable Terminal[(1)]** **==> picture [408 x 512] intentionally omitted <==** **----- Start of picture text -----**<br> Part Number List Part Number List<br>Frame Wire Size<br> (set of 3) Price (set of 4) Price<br>T7-T7M 1 (4) 4/0-500 kcmil KT7X1200-3 KT7X1200-4<br>(1) Comes standard with high profi le terminal covers.<br>Terminal Covers for Fixed Breakers - Low Profi le-Kit Includes Two Pieces<br>Part Number List Part Number List<br>Frame<br>(3-Pole) Price (4-Pole) Price<br>T7-T7M KT7XLTC-3 KT7XLTC-4<br>Terminal Covers for Fixed Breakers - High Profi le-Kit Includes Two Pieces<br>Part Number List Part Number List<br>Frame<br>(3-Pole) Price (4-Pole) Price<br>T7-T7M KT7XHTC-3 KT7XHTC-4<br>Phase Barriers - Low Profi le - 100mm - 3.93 in<br>Part Number List Part Number List<br>Frame<br>(3-Pole) Price (4-Pole) Price<br>T7-T7M KT7PBL-3 KT7PBL-4<br>Phase Barriers - High Profi le - 200mm - 7.87 in<br>Part Number List Part Number List<br>Frame<br>(3-Pole) Price (4-Pole) Price<br>T7-T7M KT7PBH-3 KT7PBH-4<br>Extended Front Terminals - IEC<br>Part Number List Part Number List<br>Frame<br>(3-Pole) Price (4-Pole) Price<br>T7-T7M KT7EF-3 KT7EF-4<br>Rear Terminals - IEC<br>Part Number List Part Number List<br>Frame<br>(set of 3) Price (set of 4) Price<br>T7-T7M KT7XR-3 KT7XR-4<br>Variable Depth Handle Operators<br>Mechanism List List Handle List<br>Frame Shaft Part Number<br>Part Number Price Price Part Number Price<br>OHB175J10X<br>OXP10X500 (19.7”) OHY175J10<br>T7 KT7VD-M<br>OHB175L10<br>KT7VD-S (19.7”) KT7VD-H<br>Direct Mount Rotary Operator Handle Early Make Contact<br>Frame Breaker Mounting Part Number List Price Frame Part Number List Price<br>T7 Fixed, Plug-In KT7RH T7 KT7EM<br>Padlock Locking Device<br>List<br>Frame Style Locking Position Breaker Mounting Part Number Price<br>T7 PLL OPEN Fixed, Drawout KT7LDO<br>T7M PLL OPEN Fixed, Draw-out KT7MLDO<br>Keylocks for the Rotary Handle Mechanism<br>List<br>Frame Style Locking Position Keys Part Number Price<br>KLF-D OPEN Different KT7KLFD<br>KLF-S OPEN Same key # 20005 KT7KLFS-20005<br>T7 KLF-S OPEN Same key # 20006 KT7KLFS-20006<br>KLF-S OPEN Same key # 20007 KT7KLFS-20007<br>KLF-S OPEN Same key # 20008 KT7KLFS-20008<br>**----- End of picture text -----**<br> ## **Keylocks on the Circuit-Breaker** |Frame|Style|Locking Position|Keys|Part Number|List<br>Price| |---|---|---|---|---|---| |T7|KLF-D|OPEN|Different|KT7KLCD|| ||KLF-S|OPEN|Same key # 20005|KT7KLCS-20005|| ||KLF-S|OPEN|Same key # 20006|KT7KLCS-20006|| ||KLF-S|OPEN|Same key # 20007|KT7KLCS-20007|| ||KLF-S|OPEN|Same key # 20008|KT7KLCS-20008|| |T7M|KLF-D|OPEN|Different|KT7MKLCD|| ||KLF-S|OPEN|Same key # 20005|KT7MKLCS-20005|| ||KLF-S|OPEN|Same key # 20006|KT7MKLCS-20006|| ||KLF-S|OPEN|Same key # 20007|KT7MKLCS-20007|| ||KLF-S|OPEN|Same key # 20008|KT7MKLCS-20008|| ABB 38 **Discount Schedule DS-STA** AC1615S - 03/10 **T7-T7M** 1000A / 1200A, 600VAC ∆ Accessories **T7** **==> picture [126 x 647] intentionally omitted <==** **==> picture [356 x 618] intentionally omitted <==** **----- Start of picture text -----**<br> Draw-Out Kits<br>Part Number List Part Number List<br>Item<br>Adaptor Moving Part Price Fixed Part Price<br>T7 - 3 pole with RC-RC KT7WMK KT7WFRC<br>T7 - 4 pole with RC-RC KT7WMK-4 KT7WFRC-4<br>Sliding Contact Blocks — T7-Draw-Out [(1)]<br>Item Moving Part List Fixed Part List<br>Breaker Price Cradle Price<br>Left Block<br>Spring charging motor<br>KT7SCFP-L (T7)<br>Spring charged contact KT7MXSCFP-L<br>Ready to close contact KT7XSCMP-L<br>(T7M)<br>Early auxiliary contact<br>Contact for trip coil release trip<br>Trip rest<br>Center Block<br>PR331 KT7XSCMP-C KT7XSCFP-C<br>PR332<br>Right Block<br>Auxiliary contacts<br>Shunt trip KT7XSCMP-R KT7XSCFP-R<br>Closing Coil<br>Undervoltage release<br>Position Key Lock (Fixed Part) — T7 - T7M<br>Part List<br>Item<br>Number Price<br>Different key KT7XPL-D<br>Same key #20005 KT7XPL-20005<br>Same key #20006 KT7XPL-20006<br>Same key #20007 KT7XPL-20007<br>Same key #20008 KT7XPL-20008<br>Locks drawout breaker in racked-in / test isolation / racked-out position.<br>Position Key Lock Accessory (Fixed Part) — T7 - T7M<br>Part List<br>Item<br>Number Price<br>Key lock accessory KT7XPLA<br>Accessory added to position key lock allows breaker to be locked in racked-out position only.<br>Mechanical Interlocks<br>Part List<br>Item<br>Number Price<br>T7 [(2)]<br>Cable T7 KT7XMLC<br>Mech. interlock plate-fi xed KT7XMLPW<br>Mech. interlock plate-draw-out KT7XMLPF<br>Neutral Current Transformers (Required for 4-Wire Ground Fault System)<br>Part List<br>Frame<br>Number Price<br>T7 400...1200A KT7XNCT1200<br>Rating Plugs<br>Part List<br>Frame Rating Plug Number Price<br>400A KT70400RP<br>600A KT70600RP<br>T7 800A KT70800RP<br>1000A KT71000RP<br>1200A KT71200RP<br>Mechanical Accessories<br>Part List<br>Item<br>Number Price<br>Flange T7 KT7XFCD<br>Mech. operation KT7XEMC<br>counter<br>IP54 door cover KT7XDC<br>**----- End of picture text -----**<br> - (1) If at least one of the accessories in table is installed on the breaker - respective pair of contact blocks must be installed on the fi xed part (cradle) and the moving part. (breaker) - (2) To interlock two circuit breakers, you have to order a cable kit and two plates. ABB 39 **Discount Schedule DS-STA** AC1615S - 03/10 **T7** ## **T7 / T7M** 1000A / 1200A, 600VAC ∆ Part-Numbering System ## **T7** **==> picture [348 x 443] intentionally omitted <==** **----- Start of picture text -----**<br> Locking Provisions:<br>X = None, A = Keylock,<br>B = Button guard,<br>C = Padlock Provision (open),<br>D = Withdrawable Position<br>Lock (Connected, test and<br>disconnected positions),<br>E = Withdrawable Position<br>Lock (Test and<br>disconnected positions)<br>Accessories<br>X = None,<br>A = Mechanical counter<br>Undervoltage:<br>0 = None, A = 24VAC/DC, B = 30VAC/DC,<br>C = 48VAC/DC, D = 60VAC/DC,<br>E = 110..120VAC/DC , F = 120..127VAC/DC,<br>G = 220..240VAC/DC, H = 240..250VAC/DC,<br>J = 380..400VAC, K = 415..440VAC<br>Shunt Trip:<br>0 = None, A = 24VAC/DC, B = 30VAC/DC, C = 48VAC/DC,<br>D = 60VAC/DC, E = 110..120VAC/DC , F = 120..127VAC/DC,<br>G = 220..240VAC/DC, H = 240..250VAC/DC,<br>J = 380..400VAC, K = 415..440VAC<br>Spring Charging Motor:<br>0 = None, A = 24..30VAC/DC, B = 48..60VAC/DC,<br>C = 100..130VAC/DC, D = 220..250VAC/DC,<br>E = 380..415VAC/DC<br>Aux Contacts:<br>0 = None, A = 1 Form C + 1BA 400VAC (T7), B = 1 Form C + 1BA 24VDC (T7),<br>C = 2 Form C 400VAC (T7-T7M), D = 2 Form C 24VDC (T7-T7M), E = S51 250VAC (T7),<br>F = S51 250VAC (T7M), G = A+C (T7), H = B+D (T7), I = C+E (T7), J = C+F (T7M),<br>K = D+E (T7), L = D+F (T7M), M = C+C (T7M), N = D+D (T7M)<br>Closing Coil:<br>0 = None, A = 24VAC/DC, B = 30VAC/DC, C = 48VAC/DC,<br>D = 60VAC/DC, E = 110..120VAC/DC , F = 120..127VAC/DC,<br>G = 220..240VAC/DC, H = 240..250VAC/DC,<br>J = 380..400VAC, K = 415..440VAC<br>Trip Unit Accessories:<br>0 = None, A = PR330V, B = PR330/D-M, C = A + B<br>**----- End of picture text -----**<br> - **Trip Unit: X** = Non-Automatic (MCS), **B** = PR231/P-LS/I, **C** = PR232/P-LSI, **E** = PR331/P-LSIG, **P** = PR332/P-LI, **R** = PR332/P-LSI, **S** = PR332/P-LSIG - **Rating Plug: 0** = None Non-Automatic (MCS), **A** = 400, **B** = 600, **C** = 800, **D** = 1000A, **E** = 1200 ## **Frame Amp Rating:** - **1** = 1000A (toggle) **2** = 1200A (toggle) **P** =1000A (motorized) **B** =1200A (motorized) ## **Version:** **B** = UL Fixed, **Q** = UL Fixed 100% Rated, **0** = Fixed Non-Automatic (MCS) - **W** = UL Draw-out1, **X** = UL Draw-out 100%1, **Y** = Draw-out non-automatic[(1)] **Breaking Capacity S, H, L** - (1) Fixed part and accessories to be ordered separately ABB 40 AC1615S - 03/10 **T8V** 1600A / 2000A / 2500A / 3000A Insulated Case Circuit Breaker **T8** **Dimensions** 3P Version: 15.00" H x 16.8" W x 11.2"D **Weight** 161 (lbs) 1600A/2000A/2500A 236 (lbs) 3000A **==> picture [14 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> T8V<br>**----- End of picture text -----**<br> The Tmax family, conforming to the UL489 and CSA C22.2 No. 5.0 Standards, is enriched with the TmaxT8 size, which allows 3000 A to be reached. Also avai- lable in the 1600A, 2000A and 2500A frames, Tmax T8 is equipped with the same electronic trip units as Tmax T7 thereby guaranteeing extremely high performances able to satisfy all installation requirements. Tmax T8 is able to interrupt the following short-circuit currents: 125kA@480VAC and 100kA@600 VAC. - Available in 3 and 4 pole versions - Four different frame ratings, 1600, 2000, 2500 & 3000 Amps - Available 100% rated version up to 3000A - Installation in vertical position only - Wide range of CSA/UL fi eld-installable accessories - Solid state trip unit available in three different versions: - PR331/P-LSI - PR331/P-LSIG - PR332/P-LI (LCD display) **UL489 / CSA C22.2 Interrupting Capacity (kA RMS)** Voltage V 240VAC 125 480VAC 125 600VAC 100 ——— **IEC 60947-2 Interrupting Capacity (kA RMS)** Voltage V 230VAC 130 415VAC 130 440VAC 130 500VAC 100 600VAC 80 === - PR332/P-LSI (LCD display) - PR332/P-LSIG (LCD display) - The ability to add internal modules for fl exible and precise confi guration: Optional modules includes: - Voltage module - Signaling module - Communications module ABB 41 AC1615S - 03/10 **T8** ## **T8V** 1600A / 2000A / 2500A / 3000A, 600VAC ∆ Electronic (AC Only) ## **T8-1600A Frame,** Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T8V||PR331/P|LSI|T8V16CW||T8V16CW-4|| |||PR331/P|LSIG|T8V16EW||T8V16EW-4|| ||100kA|PR332/P|LI|T8V16PW||T8V16PW-4|| |||PR332/P|LSI|T8V16RW||T8V16RW-4|| |||PR332/P|LSIG|T8V16SW||T8V16SW-4|| ## **T8-2000A Frame,** Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T8V||PR331/P|LSI|T8V20CW||T8V20CW-4|| |||PR331/P|LSIG|T8V20EW||T8V20EW-4|| ||100kA|PR332/P|LI|T8V20PW||T8V20PW-4|| |||PR332/P|LSI|T8V20RW||T8V20RW-4|| |||PR332/P|LSIG|T8V20SW||T8V20SW-4|| |**T8-2500A Frame,**Electronic Trip Unit (AC Only)|||||||| |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |T8V||PR331/P|LSI|T8V25CW||T8V25CW-4|| |||PR331/P|LSIG|T8V25EW||T8V25EW-4|| ||100kA|PR332/P|LI|T8V25PW||T8V25PW-4|| |||PR332/P|LSI|T8V25RW||T8V25RW-4|| |||PR332/P|LSIG|T8V25SW||T8V25SW-4|| ## **T8-3000A Frame,** Electronic Trip Unit (AC Only)[1] |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---|---| |T8V||PR331/P|LSI|T8V30CW||T8V30CW-4|| |||PR331/P|LSIG|T8V30EW||T8V30EW-4|| ||100kA|PR332/P|LI|T8V30PW||T8V30PW-4|| |||PR332/P|LSI|T8V30RW||T8V30RW-4|| |||PR332/P|LSIG|T8V30SW||T8V30SW-4|| ## **T8-3000A Frame,** Molded Case Switch (AC Only)[1] |Breaker|Rating|Magnetic Override|3-Pole, 600VAC<br>Part Number|List<br>Price|4-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---|---| |T8V-D|2000A||T8V20DW||T8V20DW-4|| ||2500A|40000A|T8V25DW||T8V25DW-4|| ||13000A (1)||T8V30DW||T8V30DW-4|| (1) Vertical terminals only ABB 42 **Discount Schedule DS-ST8** AC1615S - 03/10 **T8V** 1600A / 2000A / 2500A / 3000A, 600VAC ∆ 100% Rated Electronic (AC Only) **T8** ## **T8-1600A Frame,** 100% Rated Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T8VQ||PR331/P|LSI|T8VQ16CW|| |||PR331/P|LSIG|T8VQ16EW|| ||100kA|PR332/P|LI|T8VQ16PW|| |||PR332/P|LSI|T8VQ16RW|| |||PR332/P|LSIG|T8VQ16SW|| ## **T8-2000A Frame,** 100% Rated Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T8VQ||PR331/P|LSI|T8VQ20CW|| |||PR331/P|LSIG|T8VQ20EW|| ||100kA|PR332/P|LI|T8VQ20PW|| |||PR332/P|LSI|T8VQ20RW|| |||PR332/P|LSIG|T8VQ20SW|| ## **T8-2500A Frame,** 100% Rated Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T8VQ||PR331/P|LSI|T8VQ25CW|| |||PR331/P|LSIG|T8VQ25EW|| ||100kA|PR332/P|LI|T8VQ25PW|| |||PR332/P|LSI|T8VQ25RW|| |||PR332/P|LSIG|T8VQ25SW|| Note: vertical terminals only ## **T8-3000A Frame,** 100% Rated Electronic Trip Unit (AC Only) |Breaker|IC at<br>600VAC|Trip<br>Unit|Adjustment|3-Pole, 600VAC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T8VQ||PR331/P|LSI|T8VQ30CW|| |||PR331/P|LSIG|T8VQ30EW|| ||100kA|PR332/P|LI|T8VQ30PW|| |||PR332/P|LSI|T8VQ30RW|| |||PR332/P|LSIG|T8VQ30SW|| Note: vertical terminals only ABB 43 **Discount Schedule DS-ST8** AC1615S - 03/10 **T8** ## **T8V** 1600A / 2000A / 2500A / 3000A, 600VAC ∆ Accessories ## **Shunt Trips (YO) and Closing Coils (YC)** =}= Bs |Frame Size|Voltage|YO<br>Part Number|List<br>Price|YC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T8|24VDC<br>30VAC/DC<br>48VAC/DC<br>60VAC/DC<br>110/120VAC/DC<br>120/127VAC/DC<br>220/240VAC/DC<br>250VAC/DC<br>380/400VAC<br>440/480VAC|KT8ES0<br>KT8ES9<br>KT8ES8<br>KT8ES7<br>KT8ES6<br>KT8ES5<br>KT8ES4<br>KT8ES3<br>KT8ES2<br>KT8ES1||KT8EC0<br>KT8EC9<br>KT8EC8<br>KT8EC7<br>KT8EC6<br>KT8EC5<br>KT8EC4<br>KT8EC3<br>KT8EC2<br>KT8EC1|| ## **Undervoltage Release (UVR) or Additional Shunt Trip (YO2)** |Frame Size|Voltage|YO<br>Part Number|List<br>Price|YC<br>Part Number|List<br>Price| |---|---|---|---|---|---| |T8|24VDC<br>30VAC/DC<br>48VAC/DC<br>60VAC/DC<br>110/120VAC/DC<br>120/127VAC/DC<br>220/240VAC/DC<br>250VAC/DC<br>380/400VAC<br>440/480VAC|KT8EU0<br>KT8EU9<br>KT8EU8<br>KT8EU7<br>KT8EU6<br>KT8EU5<br>KT8EU4<br>KT8EU3<br>KT8EU2<br>KT8EU1||KT8ES0-2<br>KT8ES9-2<br>KT8ES8-2<br>KT8ES7-2<br>KT8ES6-2<br>KT8ES5-2<br>KT8ES4-2<br>KT8ES3-2<br>KT8ES2-2<br>KT8ES1-2|| **Note** : UVR and YO2 are mutually exclusive (only one device can be installed) ## **Stored Energy Motor (M)** |Frame Size|Voltage|Part<br>Number|List<br>Price| |---|---|---|---| |T8|24/30VAC/DC<br>48/60VAC/DC<br>100/130VAC/DC<br>220/250VAC/DC|KT8EM9<br>KT8EM7<br>KT8EM5<br>KT8EM3|| ## **Signaling Contacts** |Frame Size|Voltage|Part<br>Number|List<br>Price| |---|---|---|---| |T8|4 aux. cont. open/close PR331<br>4 aux. cont. open/close PR332<br>4 aux. cont. open/close for PR232-331(low power <24V)<br>4 aux. cont. open/close for PR332(lowpower <24V)|KT8AS4<br>KT8AS4-332<br>KT8AS4L<br>KT8AS4L-332|| ||BA - bell alarm contact ( 1 form "c")<br>BA + remote reset 24…30VAC/DC<br>BA + remote reset 110…130VAC/DC<br>BA + remote reset 220…240VAC/DC|KT8ETBA<br>KT8ETBAR9<br>KT8ETBAR5<br>KT8ETBAR4|| ||UVR de-energized contact - NC<br>UVR de-energized contact - NO|KT8EUE10<br>KT8EUE01|| Note: 4 aux. cont. open/close supplied as standard with PR332 trip unit ABB 44 **Discount Schedule DS-ST8** AC1615S - 03/10 **T8** ## **T8V** 1600A / 2000A / 2500A / 3000A, 600VAC ∆ Accessories **Locking Devices** Part List Frame Size Description Number Price Key lock open position - different keys KT8KL-D Key lock open position - same key no. 20005 KT8KL-20005 Key lock open position - same key no. 20006 KT8KL-20006 Key lock open position - same key no. 20007 KT8KL-20007 T8 Key lock open position - same key no. 20008 KT8KL-20008 Padlock device in open position KT8EPD1 Padlock device in open position (HD) KT8EPDHD1 r Pushbuttons protection ~~e~~ KT8EPG **Note** : KT8EPD1/KT8EPDHD1 are mutually exclusive with KT8EPG **Connection Accessories** Part List Frame Size Description Number Price Cable terminals 1600A (1/0 - 750MCM - kit of 3 K8TL Cable terminals 2500A (1/0 - 750MCM) - kit of 3 K8TM T8 Rear T terminal (2500A max.) - kit of 6 KT8VR2500 Rear T terminal (2500A max.) - kit of 8 KT8VR2500-4 **Note** : K8TL/K8TM requires the installation of KT8PBH-3 **Mechanical Accessories** aay Part List |Frame Size|Description|Part<br>Number|List<br>Price| |---|---|---|---| |T8|Door fl ange<br>IP54 protection cover (NEMA 3S/13)|KT8FCD<br>KT8EDC|| ||Separating partition low PB100 3 pole - 2pcs<br>Separating partition low PB100 4 pole - 3pcs<br>Separating partition high PB200 3 pole - 2pcs<br>Separating partition high PB200 4 pole - 2pcs|KT8PBL-3<br>KT8PBL-4<br>KT8PBH-3<br>KT8PBH-4|| ||Mechanical operation counter|KT8EMC|| ## **Accessories for Trip Units** |Frame Size|Description|Part<br>Number|List<br>Price| |---|---|---|---| |T8|Rating plug In=1000A<br>Rating plug In=1200A<br>RatIng plug In=1600A<br>RatIng plug In=2000A<br>RatIng plug In=2500A<br>RatIng plug In=3000A|KT81000RP<br>KT81200RP<br>KT81600RP<br>KT82000RP<br>KT82500RP<br>KT83000RP|| ||PR330/V for PR332/P 3 pole (voltage measurement)<br>PR330/V for PR332/P 4 pole (voltage measurement)<br>PR330/D-M for PR332/P (MODBUS RTU communication)|KT8PR330V-3<br>KT8PR330V-4<br>KT8330DMOD|| ||PR030B - Battery power supply unit|KT8EPR030B|| ABB 45 **Discount Schedule DS-ST8** AC1615S - 03/10 **T8V** 1600A / 2000A / 2500A / 3000A, 600VAC ∆ Part-Numbering System **T8** ## **T8V** **==> picture [506 x 589] intentionally omitted <==** **----- Start of picture text -----**<br> Locking Provisions:<br>A = Keylock D = A+B<br>B = Button guard E = A+C<br>C = Padlock Provision X = None<br>Accessories<br>X = None G = A+C<br>A = Mechanical counter H = A+D<br>B = Bell Alarm J = A+E<br>C = Bell Alarm w/remote reset 24..30VAC/DC<br>D = Bell Alarm w/remote reset 110..130VAC/DC<br>E = Bell Alarm w/remote reset 220..240VAC/DC<br>F = A+B<br>Undervoltage: Second shunt trip:<br>0 = None F = 120..127VAC/DC L = 24VDC<br>A = 24VDC G = 220..240VAC/DC M = 30VAC/DC<br>B = 30VAC/DC H = 240..250VAC/DC N = 48VAC/DC<br>C = 48VAC/DC J = 380..400VAC P = 60VAC/DC<br>Q = 110..120VAC/DC<br>D = 60VAC/DC J = 440 VAC<br>R = 120..127VAC/DC<br>E = 110..120VAC/DC S = 220..240VAC/DC<br>T = 240..250VAC/DC<br>Shunt Trip: UV = 440..480 VAC = 380..400VAC<br>0 = none<br>A = 24VDC F = 120..127VAC/DC<br>B = 30VAC/DC G = 220..240VAC/DC<br>C = 48VAC/DC H = 240..250VAC/DC<br>D = 60VAC/DC J = 380400VAC<br>E = 110..120VAC/DC K = 440VAC<br>Contacts [1] :<br>0 = None<br>A = 4 aux contacts D = UVR De-Energized NC G = B + E<br>B = 4 aux. contacts digital (24V) E = A + D<br>C = UVR De-Energized NO F = A + E<br>1 4 Aux. contacts supplied as standard with PR332.<br>Spring Charging Motor:<br>0 = None C = 100..130VAC/DC<br>A = 24..30VAC/DC D = 220..250VAC/DC<br>B = 48..60VAC/DC<br>Closing Coil:<br>0 = None C = 48VAC/DC F = 120..127VAC/DC J = 380..400VAC<br>A = 24VDC D = 60VAC/DC G = 220..240VAC/DC K = 440VAC<br>B = 30VAC/DC E = 110..120VAC/DC H = 240..250VAC/DC<br>Trip Unit Accessories PR332/P only:<br>0 = None<br>B = Voltage measuring module<br>C = Modbus module<br>Trip Unit:<br>C = PR331/P-LSI E = PR331/P-LSIG R = PR332/P-LSI<br>D = Non-Automatic (MCS) P = PR332/P-LI S = PR332/P-LSIG<br>Rating Plug:<br>D = 1000 F = 1600 H = 2500 0 = Non-Automatic (MCS)<br>E = 1200 G = 2000 J = 3000<br>Frame Amp Rating:<br>C = 1600 (3P) E = 2500 (3P) G = 1600 (4P) J = 2500 (4P)<br>D = 2000 (3P) F = 3000 (3P) H = 2000(4P) K = 3000 (4P)<br>Version:<br>B = UL Fixed 80% rated Q = UL Fixed 100% Rated 0 = Fixed Non-Automatic (MCS)<br>**----- End of picture text -----**<br> **Breaking Capacity V** (T8 UL) ABB 46 AC1615S - 03/10 **Acc.** ## **Accessories** Electrical T1-T6 ## **Shunt Trips** (Standard)[(1)] For remote opening of circuit breaker. Guaranteed operation for a voltage of between 75-110% of the rated power supply voltage. T1-T6 mounts in the left hand cavity cannot be used with UVR on 2-3P breakers **==> picture [19 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> KT3S4<br>**----- End of picture text -----**<br> |Frame Size|Voltage|Factory Installation(1)|Factory Installation(1)|Field Installation|Field Installation| |---|---|---|---|---|---| |||Part Number<br>Suffi x|List Price<br>Adder|Part<br>Number|List<br>Price| |T1-T2-T3|480 - 500VAC<br>220-250VAC/DC<br>380 - 440VAC<br>110 - 125VAC/DC<br>48 - 60VAC/DC<br>24 - 30VAC/DC<br>12VDC|S1<br>S2<br>S3<br>S4<br>S7<br>S8<br>S9||KT3S1<br>KT3S2<br>KT3S3<br>KT3S4<br>KT3S7<br>KT3S8<br>KT3S9|| |Ts3|480VAC/250VDC<br>240 VAC<br>120VAC/125VDC<br>48VDC<br>24VAC/VDC<br>12VDC|S1<br>S2<br>S4<br>S7<br>S8<br>S9||KTs3S1<br>KTs3S2<br>KTs3S4<br>KTs3S7<br>KTs3S8<br>KTs3S9|| |T4-T5-T6|480-500VAC<br>220/250VAC/DC<br>380-440VAC<br>110-125VAC/DC<br>48-60VAC/DC<br>24VAC/DC<br>12VDC|S1<br>S2<br>S3<br>S4<br>S7<br>S8<br>S9||KT6S1<br>KT6S2<br>KT6S3<br>KT6S4<br>KT6S7<br>KT6S8<br>KT6S9|| ## **Shunt Trips** (Permanent Supply)[(1)] **==> picture [40 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> T1 with KT3S4<br>**----- End of picture text -----**<br> For remote opening of circuit breaker. Guaranteed operation for a voltage of between 75-110% of the rated power supply voltage. These shunt trips have much lower power consumption. |||Factory Installation(1)|Field Installation|Field Installation| |---|---|---|---|---| |Frame Size|Voltage|Part Number<br>Suffi x<br>List Price<br>Adder|Part<br>Number|List<br>Price| |Ts3|24VDC<br>120VAC|SA<br>SB|KTs3SP4<br>KTs3SP8|| |T4-T5-T6<br>24-30VDC<br>SP4<br>110/120/VAC<br>SP8<br>**Shunt Trip Connector**(Required for Ts3)(2)<br>Ts3<br>Fixed Mount<br>Not required for factory installed<br>Draw-out<br>Not required for factory installed<br>ee|||KT6SP4<br>KT6SP8<br>KTs3C-SU<br>KTs3C-SUP<br>DD|| > (1) Add suffi x to circuit breaker part number. See p.4 for more details. (2) Must be ordered separately for fi eld installation. ABB 47 **Discount Schedule DS-STA** AC1615S - 03/10 ## **Accessories Acc.** Electrical T1-T6 ## **Undervoltage Release -** UVR Will trip circuit breaker when connected voltage drops to 35-70% of the undervoltage release voltage rating. Will allow circuit breaker to close when voltage is approximately 85% of the rated voltage. T1-T6 mounts in the left hand cavity cannot be used with shunt trip on 2-3P breakers Factory Installation[(1)] Field Installation Part Number List Price Part List Frame Size Voltage Suffi x Adder Number Price 480 - 500VAC U1 KT3U1 220-250VAC/DC U2 KT3U2 380 - 440VAC U3 KT3U3 T1-T2-T3 110 - 125VAC/DC U4 KT3U4 60VAC/DC U5 KT3U5 48VAC/DC U7 KT3U7 24 - 30VAC/DC U8 KT3U8 480VAC U1 KTs3U1 240VAC U2 KTs3U2 24VAC U3 KTs3U3 120VAC U4 KTs3U4 KT3U2 Ts3 250VDC U5 KTs3U5 125VDC U6 KTs3U6 48VDC U7 KTs3U7 24VDC U8 KTs3U8 480-500VAC U1 KT6U1 220/250VAC/DC U2 KT6U2 380-440VAC U3 KT6U3 T4-T5-T6 110-125VAC/DC U4 KT6U4 60VAC/DC U5 KT6U5 48VAC/DC U7 KT6U7 24VAC/DC U8 KT6U8 ~~ie~~ **Undervoltage Trip Connector** (Required for Ts3)[(2)] Ts3 Plug-In/Draw-outFixed Mount Not required for factory installedNot required for factory installed KTs3CKTs3C-SU-SUP a > (1) Add suffi x to circuit breaker part number. See p.4 for more details. > (2) Must be ordered separately for fi eld installation. ABB 48 **Discount Schedule DS-STA** AC1615S - 03/10 **Accessories** Electrical T1-T6 **Acc.** ## **Auxiliary Contacts - AUX[(1)]** Auxiliary contacts are for indication of the circuit breaker open-closed. Bell alarm contacts (BA) can be used to indicate circuit breaker tripped. **==> picture [40 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> T1 with K3TAS<br>**----- End of picture text -----**<br> |||Factory Installation|Factory Installation||Field Installation|Field Installation| |---|---|---|---|---|---|---| ||Frame Size|Part Number<br>Suffi x|List Price<br>Adder||Part<br>Number|List<br>Price| |T1-T2-T3(2)|1 AUX "C" + 1 BA "C" 250VAC/DC<br>3 AUX "C" + 1 BA "C" 250VAC/DC|A<br>A3|||KT3AS<br>KT3AS3|| |T2(3)|2 AUX "C" + 1 BA "C" PR221DS<br>1 AUX "C" + 1 BA "C" + 1S51 "C" PR221DS|AE<br>AE2|||KT2AS-E<br>KT2AS-E2|| |Ts3|2 AUX "C" 250VAC/DC<br>1 AUX "C" + 1 BA "C" 250VAC/DC|A<br>BA|||KTs3AS<br>KTs3BA|| ||1 AUX "C" + 1 BA "C" 250VAC/DC|A|||KT6AS|| ||2 AUX "C" 400VAC|A2|||KT6AS2|| |T4-T5-T6|3 AUX "C" + 1 BA "C" 250VAC/DC|A3|||KT6AS3|| ||3 AUX "C" + 1 BA "C" 24VDC|A3L|||KT6AS3L|| |||||||| |**Auxiliary Contact Connector**(Required for Ts3)(4)||||||| |Ts3<br>Fixed<br>Not required for factory installed<br>Not required for factory installed<br>KTs3C-AB<br>Plug-In /Drawout<br>KTs3C-ABP<br>ee||||||| KTs3AS > (1) Add suffi x to circuit breaker part number. See p.4 for more details. > (2) Not compatible for T2 with PR221DS trip unit. (3) For installation on T2 with PR221DS electronic trip unit - (4) Must be ordered separately for fi eld installation. ABB 49 **Discount Schedule DS-STA** AC1615S - 03/10 **Accessories** Motor Operators T1-T6 **Acc.** ## **Electrical Operators** Allows remote opening and closing of circuit breaker Part List Frame Size Voltage Number Price **Solenoid Operator** 48 - 60VDC KT3M1 T1-T2-T3 ~~a~~ 110 - 250VAC/DC KT3M2 **Direct Action Motor Operator** 240VAC/250VDC KTs3M2 120VAC/125VDC KTs3M4 Ts3 48VDC KTs3M7 24VDC KTs3M8 **Motor Operator Connector** (Required for Ts3)[(1)] KT3M1 Fixed Mount KTS3C-M Ts3 ~~a~~ Plug-In / Draw-out KTS3C-MP **Stored Energy Motor Operator** 220-250VAC/DC KT5M2 110--125-VAC/DC KT5M4 T4-T5 48-60VDC KT5M7 24VDC KT5M8 380VAC KT5M3 **Stored Energy Motor Operator** 220-250VAC/DC KT6M2 110--125-VAC/DC KT6M4 T6 48-60VDC KT6M7 24VDC KT6M8 380VAC KT6M3 **Stored Energy Motor With Communication** (IEC) 220-250VAC/DC KT5M2-E 380VAC KT5M3-E T4-T5 110-125VAC/DC KT5M4-E 48-60VDC KT5M7-E po 24VDC KT5M8-E 220-250VAC/DC KT6M2-E 380VAC KT6M3-E T6 110-125VAC/DC KT6M4-E 48-60VDC KT6M7-E 24VDC KT6M8-E KT5M2 **Dry Contact for Remote/Manual Operation** ~~—~~ T4-T5-T6 — - ~~EE~~ KT6MA KTS3M2 (1) Must be ordered separately for fi eld installation ABB 50 **Discount Schedule DS-STA** AC1615S - 03/10 **Accessories** Trip Units **Acc.** **Neutral Current Transformers** (Required for 4-Wire Ground Fault Systems) Part List Frame Size Number Price 100A KT4NCT-100 T4 150A KT4NCT-150 250A KT4NCT-250 300A KT5NCT-300 T5 400A KT5NCT-400 600A KT5NCT-600 600A KT6NCT-600 T6 ~~———~~ 800A KT6NCT-800 **Note** : X4 connector required for T4 - T5 - T6 **Connector for PR222DS** Fixed Circuit-Breaker Plug-in or Draw-Out Circuit-Breaker KT5FDU T4-T5-T6 Part List Part List Number Price Number Price X3 Connector KT6CX3 KT6CX3-P X4 Connector KT6CX4 KT6CX4-P ~~a~~ **Front Display Unit** Used with List High Profi le Cover Price T4-T5 with PR222DS/P or PR2222DS/PD KT5FDU T6 ~~———~~ with PR222DS/P or PR222DS/PD KT6FDU — ABB 51 **Discount Schedule DS-STA** AC1615S - 03/10 **Acc.** ## **Technical Data** Shunt Trips/Undervoltages **==> picture [125 x 650] intentionally omitted <==** ## **Standard Shunt Trip** |**Standard Shunt Trip**||||||||| |---|---|---|---|---|---|---|---|---| |Voltage||||Inrush Power Consumption||||| ||T1,T2,T3||Ts|3|T4,T5,T6||T|7| ||AC (VA)|DC(W)|AC(VA)|DC(W)|AC(VA)|DC(W)|AC(VA)|DC(W)| |12 VDC<br>24 VAC/DC<br>24…30 VAC/DC<br>30 VAC/DC<br>48 VAC/DC<br>48…60 VAC/DC<br>60 VAC/DC<br>100…120 VAC/DC<br>120…127 VAC/DC<br>110…127 VAC 110…125 VDC<br>220…240 VAC/DC<br>220…240 VAC 220…250 VDC<br>240…250 VAC/DC<br>380…400 VAC<br>380…440 VAC<br>415…440 VAC<br>480 VAC<br>480…525 VAC<br>Opening Time (ms)|-|50|-|120|-|150|-|-| ||-|-|100|100 or 4(1)|-|-|300|300| ||50|50|-|-|150|150|-|-| ||-|-|-|-|-|-|300|300| ||-|-|-|120|-|-|300|300| ||60|60|-|-|150|150|-|-| ||-|-|-|-|-|-|300|300| ||-|-|100 or 4(1)|-|-|-|300|300| ||-|-|-|-|-|-|300|300| ||50|50|-|120|150|150|-|-| ||-|-|-|-|-|-|300|300| ||50|50|100|120|150|150|-|-| ||-|-|-|-|-|-|300|300| ||-|-|-|-|-|-|300|-| ||55|-|-|-|150|-|-|-| ||-|-|-|-|-|-|300|-| ||-|-|100|-|-|-|-|-| ||55|-|-|-|150|-|-|-| ||15|15|≤15|≤15|15|15|20|20| ## **Permanent Supply Shunt Trip** |Voltage|T4,T5,T6<br>AC (VA)<br>DC (W)|T4,T5,T6<br>AC (VA)<br>DC (W)| |---|---|---| |24 VAC/DC<br>100…120 VAC|4<br>4|4<br>-| ## **Undervoltage** |**Undervoltage**||||||||| |---|---|---|---|---|---|---|---|---| |Voltage|Power Consumption During Permanent Operation|||||||| ||T1,T2,T3||Ts3||T4, T5, T6||T7|| ||AC (VA)|DC(W)|AC(VA)|DC(W)|AC(VA)|DC(W)|AC(VA)|DC(W)| |24 VAC/DC<br>24…30 VAC/DC<br>30 VAC/DC<br>48 VAC/DC<br>60 VAV/DC<br>110…120 VAC/DC<br>120…127 VAC/DC<br>110…127 VAC 110…125 VDC<br>220…240 VAC/DC<br>220…240 VAC 220…250 VDC<br>220…250 VAC<br>240…250 VAC/DC<br>380…400 VAC<br>380…440 VAC<br>415 - 440 VAC<br>480…525 VAC<br>480 VAC<br>Opening Time (ms)|-|-|6|3|-|-|3.5|3.5| ||1.5|1.5|-|-|6|3|-|-| ||-|-|-|-|-|-|3.5|3.5| ||1|1|6|3|6|3|-|-| ||1|1|-|-|6|3|-|-| ||-|-|6|-|-|-|3.5|3.5| ||-|-|-|-|-|-|3.5|3.5| ||2|2|-|-|6|3|-|-| ||-|-|-|-|-|-|3.5|3.5| ||2.5|2.5|-|3|6|3|-|-| ||-|-|6|-|-|-|-|-| ||-|-|-|-|-|-|3.5|3.5| ||-|-|-|-|-|-|3.5|-| ||3|-|-|-|6|-|-|-| ||-|-|-|-|-|-|3.5|-| ||4|-|-|-|6|-|-|-| ||-|-|6|-|-|-|-|-| ||15|15|≤18|≤18|≤25|≤25|≤25|≤25| (1) Shunt trip permanent supply ABB 52 AC1615S - 03/10 **Technical Data** Electrical Operators **Acc.** **==> picture [127 x 647] intentionally omitted <==** ## **Electrical Operator,** T1-T3 |**Electrical Operator,**T1-T3|**Electrical Operator,**T1-T3||| |---|---|---|---| |Rated Voltage||AC|DC| |||-|48…60| |||110...250|110...250| |Operating Voltage||85…110% Un|| |<br>Inrush power absorption during operation||1800 (VA)|1000 (W)| |Power on stand by||< 100 (mW)|| |Time|opening (s)<br>closing (s)|<<br><|0.1<br>0.1| |Minimum control impulse time on<br>opening and closing (ms)||>100|| This unit is permanently supplied on stand by, a control is applied by means of external contact in a low power circuit. Contact characteristics: Voltage AC/DC=24V Current 50 mA ## **Electrical Operator,** Ts3 |**Electrical Operator,**Ts3|**Electrical Operator,**Ts3||| |---|---|---|---| |Rated Voltage||AC|DC| |||-|24| |||-|48…60| |||120|125| |||240|250| |||440|-| |Operating Voltage||85…110 % Un|| |<br>Inrush power absorption||500 (VA)|500 (W)| |Service power absorption||350 (VA)|350 (W)| |Time constant (ms)||18|| |Duration|opening (s)<br>closing (s)|0.1<br>0.1|| |Minimum duration of the opening and closing<br>command impulse (ms)||≥150|| |**Electrical Operator,**T4-T5|||| |Voltage||AC|DC| |||-|24| |||-|48…60| |||110…125|110…125| |||220-250|220-250| |||380|-| |Operating Voltage||85…110%|| |<br>Inrush power consumption||≤ 300VA|≤ 300W| |In service power consumption||≤150VA|≤150W| |Duration|opening (s)<br>closing (s)<br>resetting (s)|1.5<br>< 0.1<br>3|| |Minimum duration of the opening and closing<br>command impulse (ms)||≥100|| |**Electrical Operator,**T6|||| |Voltage||AC|DC| |||-|24| |||-|48…60| |||110-125|110-125| |||220-250|220-250| |||380|-| |Operating Voltage||85…110%|| |<br>Inrush power consumption||≤ 400VA|≤ 400W| |In service power consumption||≤150VA|≤150W| |Duration|opening (s)<br>closing (s)<br>resetting (s)|<<br>|3<br>0.1<br>5| |Minimum duration of the opening and closing<br>command impulse (ms)||≥100|| ABB 53 AC1615S - 03/10 **Accessories** Mechanical T1-T6 **Acc.** ## **Standard Cable Terminal** **==> picture [28 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> KT3100-3<br>**----- End of picture text -----**<br> **==> picture [293 x 140] intentionally omitted <==** **----- Start of picture text -----**<br> |||||| |---|---|---|---|---| |Part Number|List|Part Number|List| |Frame|Wire Size| |(set of 3)|Price|(set of 4)|Price| |T1|100A (14 AWG-1/0)|Integral|Integral| |T2|100A (14 AWG-1/0)|KT2100-3|KT2100-4| |100A (14 AWG - 1/0 kcmil)|KT3100-3|KT3100-4| |T3|225A (4 AWG - 350 kcmil)|KT3225-3|KT3225-4| |Ts3|100A (14 AWG - 1/0 kcmil)|KTs3100-3|—| |150A (2 AWG - 4/0 kcmil)|KTs3150-3|—| |225A (4 AWG - 300 kcmil)|KTs3225-3|—| |100A (14 AWG - 1/0 kcmil)|KT4100-3|KT4100-4| |T4| |250A (6 AWG - 350 kcmil)|KT4250-3|KT4250-4| |T5|300A (250 kcmil - 500 kcmil)|KT5300-3|KT5300-4| |T5|[(1)]|400A (2x 3/0 - 2x 250 kcmil)|KT5400-3|KT5400-4| |T5|600A (2x 3/0 - 2x 500 kcmil)|KT5600-3|—| |T6|600A (2x 250 - 2x 500 kcmil)|KT6600-3|—| |T6|[(1)]|800A (3x 2/0 - 3x 400 kcmil)|KT6800-3|—| **----- End of picture text -----**<br> **Note** : for power control tap lugs, please consult your local ABB offi ce **==> picture [30 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> KT1HTC-3<br>**----- End of picture text -----**<br> **==> picture [403 x 150] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |Terminal Cover Seals| |Part Number|List| |Frame| |(3-Pole)|Price| |T1 - T2 - T3 - T4 - T5|KT5LC-S| |ff| |Terminal Covers for Fixed Breakers|- Low Profi le-Kit (kit of 2)| |Part Number|List|Part Number|List| |Frame| |(3-Pole)|Price|(4-Pole)|Price| |T1|KT1LTC-3|KT1LTC-4| |T2|KT2LTC-3|KT2LTC-4| |T3|KT3LTC-3|KT3LTC-4| |Ts3|KTs3LTC-3|KTs3LTC-4| |T4|KT4LTC-3|KT4LTC-4| |T5|KT5LTC-3|KT5LTC-4| |T6|KT6LTC-3|KT6LTC-4| **----- End of picture text -----**<br> ## **Terminal Covers for Fixed Breakers** - High Profi le-Kit (kit of 2) **==> picture [393 x 69] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |Part Number|List|Part Number|List| |Frame| |(3-Pole )|Price|(4-Pole)|Price| |T1|KT1HTC-3|KT1HTC-4| |T2|KT2HTC-3|KT2HTC-4| |T3|KT3HTC-3|KT3HTC-4| |Ts3|KTs3HTC-3|KTs3HTC-4| |T4|KT4HTC-3|KT4HTC-4| |T5|KT5HTC-3|KT5HTC-4| |T6|KT6HTC-3|KT6HTC-4| **----- End of picture text -----**<br> ## **Terminal Cover Fixed Part of CB** (Kit of 2) **==> picture [393 x 39] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |Part Number|List|Part Number|List| |Frame| |(3-Pole )|Price|(4-Pole)|Price| |Ts3|KTs3TCFP-3|KTs3TCFP-4| |T4|KT4TCFP-3|KT4TCFP-4| |T5|KT5TCFP-3|KT5TCFP-4| **----- End of picture text -----**<br> **==> picture [28 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> KT4LTC-3<br>**----- End of picture text -----**<br> (1) Comes standard with high profi le terminal covers. ABB 54 **Discount Schedule DS-STA** AC1615S - 03/10 **Accessories** Mechanical T1-T6 **Acc.** |||||||||||||**Phase Barriers**- Low Prof le 100mm - 3.93 in|**Phase Barriers**- Low Prof le 100mm - 3.93 in|**Phase Barriers**- Low Prof le 100mm - 3.93 in|||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| ||||||||||||||Frame|Part Number<br>(set of 4)|List<br>Price|Part Number<br>(set of 6)|List<br>Price| |||||||||||||T1-T3||KT3PBL-3||KT3PBL-4|| |||||||||||||T4-T5||KT5PBL-3||KT5PBL-4|| |||||||||||||T6||KT6PBL-3||KT6PBL-4|| |||||||||||||**Phase barriers**- High Prof le 200mm - 7.87 in|||||| ||||||||||||||Frame|Part Number<br>(set of 4)|List<br>Price|Part Number<br>(set of 6)|List<br>Price| |||||||||||||T1-T3||KT3PBH-3||KT3PBH-4|| |||||||||||||T4-T5||KT5PBH-3||KT5PBH-4|| |KT2EF-3||||||||||||**Saddle Terminals for Copper Cables**- IEC|||||| ||||||||||||||Frame|Part Number<br>( set of 3 )|List<br>Price|Part Number<br>(set of 4)|List<br>Price| |||||||||||||T2||KT2100S-3||KT2100S-4|| |||||||||||||T3||KT3225S-3||KT3225S-4|| |||||||||||||Ts3||K4TES||K4TES-4|| |||||||||||||T4||KT4250S-3||KT4250S-4|| |||||||||||||T5||KT5300S-3||KT5300S-4|| |||||||||||||**Extended**|**Front Terminals**- IEC||||| ||||||||||||||Frame|Part Number<br>(set of 3)|List<br>Price|Part Number<br>(set of 4)|List<br>Price| |||||||||||||T2||KT2EF-3||KT2EF-4|| |||||||||||||T3||KT3EF-3||KT3EF-4|| |||||||||||||Ts3||KTs3EF-3||KTs3EF-4|| |||||||||||||T4||KT4EF||KT4EF-4|| |||||||||||||T5||KT5EF||KT5EF-4|| |||||||||||||T6||KT6EF-3||KT6EF-4|| ||KT4EF|||||||||||**Rear Terminals**- IEC|||||| ||||||||||||||Frame|Part Number<br>(set of 3)|List<br>Price|Part Number<br>(set of 4)|List<br>Price| |||||||||||||T2||KT2R-3||KT2R-4|| |||||||||||||T3||KT3R-3||KT3R-4|| |||||||||||||T4||KT4R-3||KT4R-4|| |||||||||||||T5||KT5R-3||KT5R-4|| |||||||||||||T6||KT6R-3||KT6R-4|| **==> picture [21 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> KT2R-3<br>**----- End of picture text -----**<br> (1) Includes high profi le terminal cover. ABB 55 AC1615S - 03/10 **Discount Schedule DS-STA** ## **Acc.** ## **Accessories** Mechanical T1-T6 Locking Devices and Handle Operators **Variable Depth Handle Operators** Mechanism List List Handle List Frame NEMA Rating Part Number Price Shaft Part Number Price Part Number Price OHB65J6 1, 3R, 12 OHY65J6 OXP6X430 (16.9”) T1-T2-T3 KT3VD-M OHB80L6 4, 4X OHY80L6 1 KT3VD-S (11.8”) KT3VD-H 1, 3R, 12 OHB125J10X OXP10X500 (19.7") Ts3 4, 4X KTs3VD-M OHB125L10 OHB65J6 1 KTs3VD-S (20") KTs3VD-H 1, 3R, 12 OHB125J10X OXP10X500 (19.7") T4-T5 4, 4X KT5VD-M OHB125L10 1 KT5VD-S (19.7") KT5VD-H 1, 3R, 12 OHB125J10X OXP10X500 (19.7") T6 4, 4X KT6VD-M OHB125L10 ~~oe~~ 1 KT5VD-S (19.7") KT6VD-H **Note** : Discount schedule DS-H applies for part-numbers starting with OH and OX KT5VD-M, KT5VD-S, KT5VD-H **Direct Mount Rotary** Breaker Part List Frame Mounting Number Price T1-T2-T3 Fixed, Plug-In KT3RH Ts3 Fixed, Plug-In KTs3RH Ts3 Draw-Out KTs3RHW T4-T5 Fixed, Plug-In KT5RH T4-T5 Draw-Out KT5RHW T6 Fixed, Plug-In KT6RH s T6 Draw-Out ~~s~~ KT6RHW KT5RH **Early Make Contact** |Breaker<br>Mounting<br>Fixed, Plug-In<br>Fixed, Plug-In<br>Draw-Out<br>Fixed, Plug-In<br>Draw-Out<br>Fixed, Plug-In<br>Draw-Out<br>s~~s~~|Part<br>Number<br>KT3RH<br>KTs3RH<br>KTs3RHW<br>KT5RH<br>KT5RHW<br>KT6RH<br>KT6RHW<br>~~s~~|List<br>Price<br>~~s~~| |---|---|---| |Frame|Part<br>Number|List<br>Price| |T2-T3|KT3EM|| |T4-T5|KT5EM|| |T6|KT6EM|| ABB 56 **Discount Schedule DS-STA** AC1615S - 03/10 **Acc.** ## **Accessories** Mechanical T1-T6 Locking Devices and Handle Operators ## **Padlock Locking Device** ||||||||||||Frame|Style<br>Locking Position|Breaker<br>Mounting|Part<br>Number|List<br>Price| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| ||||||||||||T1-T2-T3|PLL<br>OPEN/CLOSED<br>OPEN|Fixed|KT3LD<br>KT3LDO|| ||||||||||||Ts3|FLD<br>OPEN|Fixed, Plug-In<br>Draw-0ut|KTs3FLD<br>KTs3LDW|| ||||||||||||T4-T5|FLD<br>OPEN|Fixed, Plug-In<br>Draw-out|KT5FLD<br>KT5FLDW|| |KT3LD<br>KT5KL-D<br>~|||||||||||T6<br>FLD<br>OPEN<br>Fixed, Plug-In<br>KT6FLD<br>Draw-out<br>KT6FLDW<br>**Keylocks for the Rotary Handle Mechanism**<br>Frame<br>Style<br>Locking Position<br>Keys<br>Part<br>Number<br>List<br>Price<br>T1-T2-T3<br>RHL<br>OPEN/CLOSED<br>Different<br>KT3RHL3<br>Ts3<br>-<br>OPEN<br>Different<br>KTs3KLFD<br>Same<br>KTs3KLFD-2<br>T4-T5<br>KLF-D<br>OPEN<br>Different<br>KT5KL-D<br>KLF-S<br>OPEN<br>Same key # 20005<br>KT5KL-20005<br>KLF-S<br>OPEN<br>Same key # 20006<br>KT5KL-20006<br>KLF-S<br>OPEN<br>Same key # 20007<br>KT5KL-20007<br>KLF-S<br>OPEN<br>Same key # 20008<br>KT5KL-20008<br>T6<br>KLF-D<br>OPEN<br>Different<br>KT6KLFD<br>KLF-S<br>OPEN<br>Same key # 20005<br>KT6KLFS-20005<br>KLF-S<br>OPEN<br>Same key # 20006<br>KT6KLFS-20006<br>KLF-S<br>OPEN<br>Same key # 20007<br>KT6KLFS-20007<br>KLF-S<br>OPEN<br>Same key # 20008<br>KT6KLFS-20008<br> ~~EE~~||||| ||||||||||||**Keylocks for the Motor Operator**|**Keylocks for the Motor Operator**|||| ||||||||||||Frame|Style<br>Locking Position|Keys|Part<br>Number|List<br>Price| |||||||||||||MOL-D<br>OPEN|Different|KT5KL-MO-D|| |||||||||||||MOL-S<br>OPEN|Same key # 20005|KT5KL-MO-20005|| ||||||||||||T4-T5|MOL-S<br>OPEN|Same key # 20006|KT5KL-MO-20006|| |||||||||||||MOL-S<br>OPEN|Same key # 20007|KT5KL-MO-20007|| |||||||||||||MOL-S<br>OPEN|Same key # 20008|KT5KL-MO-20008|| |||||||||||||MOL-D<br>OPEN|Different|KT6KL-MO-D|| |||||||||||||MOL-S<br>OPEN|Same key # 20005|KT6KL-MO-20005|| ||||||||||||T6|MOL-S<br>OPEN|Same key # 20006|KT6KL-MO-20006|| |||||||||||||MOL-S<br>OPEN|Same key # 20007|KT6KL-MO-20007|| |||||||||||||MOL-S<br>OPEN|Same key # 20008|KT6KL-MO-20008|| ABB 57 **Discount Schedule DS-STA** AC1615S - 03/10 **Acc.** ## **Accessories** ## Mechanical T1-T6 ## **Plug-In Kits[(1)]** **==> picture [113 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> KT2PFF + KT2PMK (on back of breaker) +<br>breaker<br>**----- End of picture text -----**<br> |**Plug-In Kits[(1)]**||||| |---|---|---|---|---| |**Plug-In Kits[(1)]**<br>Frame|Part Number<br>Adapter Moving Part|List<br>Price|Part Number<br>Fixed Part|List<br>Price| |T2 - 3 pole with front terminals|KT2PMK<br>oo|oo|KT2PFF<br>oo|| |T2 - 4 pole with front terminals|KT2PMK-4<br>ee|ee|KT2PFF-4<br>ee|| |T3 - 3 pole with front terminals|KT3PMK<br>ee<br>————|ee<br>————|KT3PFF<br>ee<br>————|| |T3 - 4 pole with front terminals|KT3PMK-4<br>————<br>oo|————<br>oo<br>a|KT3PFF-4<br>————<br>oo<br>ee|ee| |Ts3 - 3 pole with extended front terminals<br>Ts3 - 3 pole with rear terminals|KTs3PMK<br>————<br>rr|————<br>rr<br>a|KTs3PFF<br>KTs3PFR<br>————<br>rr<br>ee|ee| |Ts3 - 4 pole with extended front terminals<br>Ts3-4 pole with rear terminals|KTs3PMK-4<br>rr|rr<br>a|KTs3PFF-4<br>KTs3PFR-4<br>rr<br>ee|ee| |T4 - 3 pole with extended front terminals<br>T4 - 3 pole with rear horizontal terminals<br>T4 - 3 pole with rear vertical terminals|KT4PMK||KT4PFEF<br>KT4PFHR<br>KT4PFVR|| |T4 - 3 pole with extended front terminals<br>T4 - 3 pole with rear horizontal terminals<br>T4 - 3 pole with rear vertical terminals|KT4PMK-4||KT4PFEF-4<br>KT4PFHR-4<br>KT4PFVR-4|| |T5 400A - 3 pole with extended front terminals<br>T5 400A - 3 pole with rear horizontal terminals<br>T5 400A - 3 pole with rear vertical terminals|KT5PMK||KT5PFEF<br>KT5PFHR<br>KT5PFVR|| |T5 400A - 4 pole with extended front terminals<br>T5 400A - 4 pole with rear horizontal terminals<br>T5 400A - 4 pole with rear vertical terminals|KT5PMK-4||KT5PFEF-4<br>KT5PFHR-4<br>KT5PFVR-4|| |T5 600A - 3 pole with extended front terminals<br>T5 600A - 3 pole with rear horizontal terminals<br>T5 600A - 3 pole with rear vertical terminals|KT5PMK6||KT5PFEF6<br>KT5PFHR6<br>KT5PFVR6|| |T5 600A - 4 pole with extended front terminals<br>T5 600A - 4 pole with rear horizontal terminals<br>T5 600A - 4 pole with rear vertical terminals|KT5PMK6-4||KT5PFEF6-4<br>KT56PFHR6-4<br>KT5PFVR6-4|| ## **Plug Connectors, T2-T3[(1)]** Required when adding accessories to plug-in breakers **==> picture [99 x 49] intentionally omitted <==** **----- Start of picture text -----**<br> KT4PFVR<br>KT4PMK (on back of<br>breaker)<br>**----- End of picture text -----**<br> |**Plug Connectors, T2-T3[(1)]**<br>Required when adding accessories to plug-in breakers||| |---|---|---| |Required when adding accessories to plug-in breakers<br>Plug Connector|Part<br>Number|List<br>Price| |Shunt trip or UVR<br>1 form C plus 1 BA<br>3 form C plus 1 BA|KT3PC-3<br>KT3PC-6<br>KT3PC-12|| ## **Adaptors, T4-T5-T6[(1)]** Required when adding accessories to plug-in or drawout breakers |**Adaptors, T4-T5-T6[(1)]**<br>Required when adding accessories to plug-in or drawout breakers||| |---|---|---| |Required when adding accessories to plug-in or drawout breakers<br>Adaptors|Part<br>Number|List<br>Price| |1 form C plus 1 BA<br>Shunt trip/UVR<br>Stored energy operator<br>Stored energy operator plus shunt trip/UVR<br>3 form C plus 1BA|KT6ADP-6<br>KT6ADP-5<br>KT6ADP-10<br>KT6ADP-10<br>KT6ADP-12|| (1) Plug connectors (T2-T3), adaptors (T4-T5-T6), required when adding accessories to plug-in breakers. ABB 58 **Discount Schedule DS-STA** AC1615S - 03/10 **Accessories** Mechanical T1-T6 **Acc.** ## **Draw-Out Kits** **==> picture [103 x 54] intentionally omitted <==** **----- Start of picture text -----**<br> KT5WFVR<br>KT4WMK (on back of<br>breaker)<br>**----- End of picture text -----**<br> |**Draw-Out Kits**||||| |---|---|---|---|---| |Item|Part Number<br>Adaptor Moving Part|List<br>Price|Part Number<br>Fixed Part|List<br>Price| |TS3 - 3 pole with front terminals<br>TS3 - 3 pole with front cable terminals<br>TS3 - 3 pole with rear terminals|KTs3WMK||KTs3WFF<br>KTs3WFC<br>KTs3WFR|| |TS3 - 4 pole with front terminals<br>TS3 - 4 pole with front cable terminals<br>TS3 - 4 pole with rear terminals|KTs3WMK-4||KTs3WFF-4<br>KTs3WFC-4<br>KTs3WFR-4|| |T4 - 3 pole with extended front terminals<br>T4 - 3 pole with rear horizontal terminals<br>T4 - 3 pole with rear vertical terminals|KT4WMK||KT4WFEF<br>KT4WFHR<br>KT4WFVR|| |T4 - 4 pole with extended front terminals<br>T4 - 4 pole with rear horizontal terminals<br>T4 - 4 pole with rear vertical terminals|KT4WMK-4|Pf|KT4WFEF-4<br>KT4WFHR-4<br>KT4WFVR-4<br>Pf|| |T5 - 400A 3 pole with extended front terminals<br>T5 - 400A 3 pole with rear horizontal terminals<br>T5 - 400A 3 pole with rear vertical terminals|KT5WMK||KT5WFEF<br>KT5WFHR<br>KT5WFVR|| |T5 - 400A 4 pole with front extended terminals<br>T5 - 400A 4 pole with rear horizontal terminals<br>T5 - 400A 4 pole with rear vertical terminals|KT5WMK-4||KT5WFEF-4<br>KT5WFHR-4<br>KT5WFVR-4|| |T5 - 600A 3 pole with extended front terminals<br>T5 - 600A 3 pole with rear horizontal terminals<br>T5 - 600A 3 pole with rear vertical terminals|KT5WMK6||KT5WFEF6<br>KT5WFHR6<br>KT5WFVR6|| |T5 - 600A 4 pole with extended front terminals<br>T5 - 600A 4 pole with rear horizontal terminals<br>T5 - 600A 4 pole with rear vertical terminals|KT5WMK6-4||KT5WFEF6-4<br>KT5WFHR6-4<br>KT5WFVR6-4|| |T6 - 800A 3 pole with extended front terminals<br>T6 - 800A 3 pole with rear horizontal terminals<br>T6 - 800A 3 pole with rear vertical terminals|KT6WMK||KT6WFEF<br>KT6WFHR<br>KT6WFVR|| |T6 - 800A 4 pole with extended front terminals<br>T6 - 800A 4 pole with rear horizontal terminals<br>T6 - 800A 4 pole with rear vertical terminals|KT6WMK-4||KT6WFEF-4<br>KT6WFHR-4<br>KT6WFVR-4|| ## **Adaptors** — T4-T5-T6 **[(1)]** Required when adding accessories to plug-in or drawout breakers |Required when adding accessories to plug-in or drawout breakers||| |---|---|---| |Adaptors|Part<br>Number|List<br>Price| |1 form C plus 1 BA<br>Shunt trip/UVR<br>Stored energy operator<br>Stored energy operator plus shunt trip/UVR<br>3 form C plus 1BA|KT6ADP-6<br>KT6ADP-5<br>KT6ADP-10<br>KT6ADP-10<br>KT6ADP-12|| (1) Adaptors (T4-T5-T6), required when adding accessories to draw-out breakers. ABB 59 **Discount Schedule DS-STA** AC1615S - 03/10 **Accessories** Mechanical T1-T6 ## **Acc.** ## **DIN Rail Adapters** **==> picture [24 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> KT3MIF2<br>**----- End of picture text -----**<br> KT5FCD Part List Item Number Price T1/T2 (mounts on 35 mm DIN rail 15mm high) KT2DIN T3 (mounts on 35mm DIN rail 15mm high) KT3DIN Ts3 (mounts on 75 mm DIN rail) KTs3DMB **Mechanical Interlocks** Part List **T1-T2-T3** Number Price Sliding bar interlock-front mounted (2 Breakers) KT3MIF2 Sliding bar interlock-front mounted (3 Breakers) KT3MIF3 **T3** ~~—~~ Rear Interlock-horizontal KT3MI-H Rear Interlock-vertical KT3MI-V **Ts3** Horizontal KTs3MI-H Vertical — KTs3MI-V **T4-T5[(1)]** Interlock frame Mechanical Interlock frame-horizontal KT5MI-H Mechanical Interlock frame-vertical i KT5MI-V **Plate type** A T4 (F-P-W) T4 (F-P-W) KT5MIP-A B T4 (F-P-W) T5 400 (F-P-W) OR T5 600 (F) KT5MIP-B C T4 (F-P-W) T5 600 (P-W) KT5MIP-C D T5 (F-P-W) T5 400 (F-P-W) OR 630 (F) KT5MIP-D E T5 (F-P-W) T5 600 (P-W) KT5MIP-E F T5v (F-P-W) T5 600 (P-W) KT5MIP-F **T6** Horizontal KT6MI-H Vertical KT6MI-V — **Flange** T1-T2-T3 KT3FCD T4-T5 KT5FCD ee T6 KT6FCD ee (1) T4-T5 Complete assembly consists of one interlock frame and one plate. ABB 60 **Discount Schedule DS-STA** AC1615S - 03/10 **Dim.** ## **Approximate Dimensions** T1 & T2 **==> picture [52 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> T1 — 3-Pole<br>**----- End of picture text -----**<br> **T1** — Single Pole **==> picture [371 x 231] intentionally omitted <==** **----- Start of picture text -----**<br> T2 — 3 Pole<br>83<br>78<br>90<br>30 30 70<br>¯ 9.38<br>Y<br>76.2<br>X X<br>Y<br>>3 < 2<br>103<br>65 53.25<br>17<br>181 130<br>45 106.5<br>**----- End of picture text -----**<br> ABB 61 AC1615S - 03/10 **Approximate Dimensions** T3 **Dim.** ## **T3** — 3 & 4 Pole ABB 62 AC1615S - 03/10 **Dim.** ## **Approximate Dimensions** Ts3 **==> picture [70 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Ts3 — 3 & 4 Pole<br>**----- End of picture text -----**<br> **==> picture [87 x 99] intentionally omitted <==** **==> picture [66 x 99] intentionally omitted <==** **==> picture [86 x 99] intentionally omitted <==** ABB 63 AC1615S - 01/10 **Approximate Dimensions** T4 ## **Dim.** ## **T4** — 3 & 4 Pole ## **Caption** - 1 Overall dimensions with cabled accessories mounted (SOR-C, UVR-C, RC221-222) - 2 Overall dimensions with cabled auxiliary contacts mounted (only 3Q 1SY) **Flange for Drilling Templates of the Compartment Door Compartment Door** **==> picture [43 x 43] intentionally omitted <==** 3-4 POLES 3-4 POLES With flange Without flange **Drilling Templates for Support Sheet** For front terminals For rear terminals **==> picture [33 x 77] intentionally omitted <==** 3 POLES 4 POLES ABB 64 AC1615S - 03/10 **Approximate Dimensions** T5 **Dim.** ## **T5** — 3 & 4 Pole Fixing on sheet Caption - 1 Overall dimensions with cabled accessories mounted (SOR-C, UVR-C, RC221-222) - 2 Overall dimensions with cabled auxiliary contacts mounted (only 3Q 1SY) Flange for Drilling templates of the compartment door compartment door **==> picture [46 x 46] intentionally omitted <==** With flange (3-4 POLES) Without flange (3-4 POLES) Drilling templates for support sheet For front terminals For rear terminals **==> picture [42 x 39] intentionally omitted <==** 3 POLES 4 POLES 3 POLES 4 POLES ABB 65 AC1615S - 03/10 **Approximate Dimensions** T6 **Dim.** ## **T6** — 3 & 4 Pole ABB 66 AC1615S - 03/10 **Approximate Dimensions** T7 **Dim.** **T7** — 3 & 4 Pole **==> picture [47 x 47] intentionally omitted <==** **==> picture [69 x 47] intentionally omitted <==** ABB 67 AC1615S - 03/10 ## **Approximate Dimensions Dim.** T8 ABB 68 AC1615S - 03/10 **Approximate Dimensions** T8 **Dim.** ABB 69 AC1615S - 03/10 **Dim.** ## **Approximate Dimensions** T8 ABB 70 AC1615S - 03/10 **Dim.** ## **Approximate Dimensions** Variable Depth Mechanism with OHB Handle T1 - T3 **==> picture [39 x 70] intentionally omitted <==** **==> picture [33 x 32] intentionally omitted <==** ABB 71 AC1615S - 03/10 **Approximate Dimensions** Variable Depth Mechanism with OHB Handle T4 - T5 **Dim.** **==> picture [38 x 34] intentionally omitted <==** **==> picture [91 x 126] intentionally omitted <==** **==> picture [69 x 95] intentionally omitted <==** ABB 72 AC1615S - 03/10 **Approximate Dimensions** Variable Depth Mechanism T6 **Dim.** ABB 73 AC1615S - 03/10 **Dim.** ## **Approximate Dimensions** Variable Depth Mechanism T7 ABB 74 AC1615S - 03/10 ## **Notes** ABB 75 AC1615S - 03/10 ## **Notes** ABB 76 AC1615S - 03/10 ## Contact us ## **New revision** Canada ABB Inc. 2117, 32e Avenue Lachine, QC H8T 3J1 Tel: 514-420-3100 Toll free: 1-800-567-0283 Fax: 514-420-3137 While all care has been taken to ensure that the information contained in this publication is correct, no responsibility can be accepted for any inaccuracy. The Company reserves the right to alter or modify the information contained herein at any time in the light of technical or other developments. Technical specifi cations are valid under normal operating conditions only. The Company does not accept any responsibility for any misuse of the product and cannot be held liable for indirect or consequential damages. ©Copyright 2012 ABB Inc. All rights reserved. Website: www.abb.ca ## Contact us ## **ABB** 2117, 32e Avenue Lachine, QC H8T 3J1 Tel: 514-420-3100 Toll free: 1-800-567-0283 Fax: 514-420-3137 ## **New revision** (September 2011) Subject to modification. Website: www.abb.ca
Updated at February 9, 2023
ABB is a global leader in power and automation technologies, recognized for delivering innovative solutions that improve performance while minimizing environmental impact. Serving a diverse range of sectors including industrial processing, OEM, and building services, ABB provides highly reliable components designed to meet the rigorous demands of modern electrical systems. The company is particularly renowned for its advanced circuit protection solutions. This includes a comprehensive selection of thermal magnetic circuit breakers, alongside specialized RCBO, RCD, GFCI, and AFDD circuit breakers. These foundational safety components are supported by a wide array of high-quality fuse holders and circuit breaker accessories, ensuring complete protection for complex industrial and commercial installations. Beyond circuit protection, ABB excels in automation and process control. Their offering features sophisticated visual signal indicator units, industrial switch accessories, and panel instrumentation designed for intuitive system monitoring. Additionally, ABB manufactures a robust range of power relays, safety relays, and AC/DC converters, providing engineers with the critical building blocks needed for efficient, secure, and reliable control panels.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →