Image not available
Illustrative purposes only
KLEA240F-48
AC/DC DIN Rail Power Supply (PSU), ITE, 1 Output, 240 W, 48 V, 5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: COSEL
- Product type:
- SVHC: Lead (04-Feb-2026)
- Product Range: KL Series
- No. of Outputs: 1 Output
- Output Power Max: 240W
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 48V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 91.02 € |
| Current stock | 10+ |
| Lead time | 30 days |
**AC-DC Power Supplies DIN Rail Type** ~~|~~ Power ~~Ny~~ World wide Safety EMI Inrush ina] OCP OVP Factor Approvals current Correction limiting ## **KL-series** ## ~~|a~~ **Feature EMI** Complies with FCC-B, CISPR22-B, EN55011-B, EN55022-B, VCCI-B For DIN (35mm) rail products Wide operating ambient temperature range I/O terminal has 2 types, Euro Style and Barrier Blocks Style Built in overcurrent protection, overvoltage protection circuits Complies with SEMI F-47 (refer to Instruction Manual 1.1) ## a **EMS Compliance** : EN61204-3, EN61000-6-2 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11 ## ~~|~~ **Safety agency approvals** UL60950-1, UL508, C-UL (CSA60950-1), EN62368-1 Complies with DEN-AN a **5-year warranty** (refer to Instruction Manual) ## | **CE marking** Low Voltage Directive RoHS Directive ## | **UKCA marking** Electrical Equipment Safety Regulations RoHS Regulations **KL-1** www.cosel.co.jp/en/ December 27, 2022 **AC-DC Power Supplies DIN Rail Type KLEA/KLNA120F** ~~YS~~ **Ordering information - KL** O **A 120 F** OO **-** O 1 2 3 4 5 6 R UL508 usTED 1Series name **Example recommended EMI/EMC filter NAC-04-472-D** KLE : Euro Style I/O Terminals KLN : Barrier Blocks Style I/O Terminals 2Single output 3Output wattage 4Universal input 5Output voltage ay , 6Option High voltage pulse noise type : NAP series C : with Coating Low leakage current type : NAM series N2 : Screw mounting *A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. ||**MODEL**<br>~~a~~|**MODEL**<br>~~a~~|**KLEA/KLNA120F-24**|**KLEA/KLNA120F-48**| |---|---|---|---|---| |**INPUT**|**VOLTAGE[V]**<br>~~Po~~||AC85 - 264 1f (Refer to“Derating”) *9|| ||**CURRENT[A]**|**ACIN 115V**|1.2typ|| |||**ACIN 230V**|0.6typ|| ||**FREQUENCY[Hz]**<br>~~Po~~||50 / 60(45 - 66)|| ||**EFFICIENCY[%]**<br>~~oo~~|**ACIN 115V**<br>~~oo~~|86.5typ|| |||**ACIN 230V**<br>~~oo~~|88.0typ|| ||**POWER FACTOR**<br>~~—~~|**ACIN 115V**<br>~~—~~|0.98typ|| |||**ACIN 230V**<br>~~—~~|0.90typ|| ||**INRUSH CURRENT[A]**<br>*1|**ACIN 115V**|20typ (Io=100%)(at cold start Ta=25C)|| |||**ACIN 230V**|40typ (Io=100%)(at cold start Ta=25C)|| ||**LEAKAGE CURRENT[mA]**<br>~~Po~~||0.45 / 0.75max(ACIN 100V / 240V 60Hz,Io=100%,Accordingto IEC62368-1 and DEN-AN)|| |**OUTPUT**<br>~~a~~|**VOLTAGE[V]**<br>~~a~~||24|48| ||**CURRENT[A]**<br>~~a~~||5|2.5| ||**LINE REGULATION[mV]**<br>*2 <br>~~a~~||96max(Io=30-100%) *8|192max(Io=30-100%) *8| ||**LOAD REGULATION[mV]**<br>*2 <br>~~a~~||150max(Io=30-100%) *8|300max(Io=30-100%) *8| ||**RIPPLE[mVp-p]**<br>*3<br>~~a~~|**0 to +70**C <br>~~a~~|150max<br>|150max| |||**-20 - 0**C<br>~~aa~~|240max<br>~~a~~|240max| |||**Io=0 - 30%** <br>~~a~~<br>~~a~~|500max<br><br>~~a~~|650max| ||**RIPPLE NOISE[mVp-p]** *3<br>~~a~~<br>~~ee~~|**0 to +70**C <br>~~a~~|180max|180max| |||**-20 - 0**C<br>~~a~~<br>~~a~~|300max|300max| |||**Io=0 - 30%** <br>~~a~~<br>~~ee~~|500max<br>~~ee~~|650max<br>~~ee~~| ||**TEMPERATURE REGULATION[mV]**<br>~~ee~~<br>~~OO~~|**0 to +70**C <br>~~ee~~<br>~~OO~~|240max<br>~~ee~~|480max<br>~~ee~~| |||**-20 to +70**C <br>~~ee~~<br>~~OO~~|290max<br>~~ee~~|600max<br>~~ee~~| ||**DRIFT[mV]**<br>*4 <br>~~ee~~<br>~~OO~~||96max<br>~~ee~~|192max<br>~~ee~~| ||**START-UP TIME[ms]**<br>~~OO~~<br>~~Po~~||500typ (ACIN 115V,Io=100%)|| ||**HOLD-UP TIME[ms]**<br>~~Po~~||20typ (ACIN 115V,Io=100%)|| ||**OUTPUT VOLTAGE ADJUSTMENT RANGE[V]**<br>~~a~~<br>~~a~~||21.60 to 26.40|43.20 to 52.80| ||**OUTPUT VOLTAGE SETTING[V]**<br>~~a~~||24.00 to 24.96|48.00 to 49.92| |**PROTECTION**<br>**CIRCUIT AND**<br>**OTHERS**<br>~~a~~|**OVERCURRENT PROTECTION**<br>~~a~~<br>~~Po~~||Works over 105% of ratingand recovers automatically|| ||**OVERVOLTAGE PROTECTION[V]**<br>~~a~~||27.60 to 33.60|54.00 to 67.20| ||**DC_OK LAMP**<br>~~Po~~||LED(Green)|| |**ISOLATION**|**INPUT-OUTPUT**<br>~~ee~~||AC3,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin(At Room Temperature)|| ||**INPUT-PE**<br>~~Po~~||AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin(At Room Temperature)|| ||**OUTPUT-PE**<br>~~Po~~||AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin(At Room Temperature)|| |**ENVIRONMENT**<br>~~|~~|**OPERATING TEMP.,HUMID.AND ALTITUDE**<br>~~Po~~||-20 to +70C,20 - 90%RH(Non condensing),Type tested for -40Cstart-up (Refer to“Derating”)|| ||**STORAGE TEMP.,HUMID.AND ALTITUDE**<br>~~Po~~||-30 to +85C,20 - 90%RH(Non condensing)|| ||**VIBRATION**<br>*7 <br>~~Po~~||10 - 55Hz,19.6m/s2 (2G),3minutesperiod,60 minutes alongZ axis(Non operating,mounted on DIN Rail)|| ||**IMPACT**<br>~~Po~~<br>~~|~~||196.1m/s2 (20G),11ms,once each X,Y and Z axis(Packingstate)|| |**SAFETY AND**<br>**NOISE**<br>**REGULATIONS**<br>~~|~~|**AGENCY APPROVALS**<br>~~|~~||UL60950-1,C-UL(CSA60950-1),EN62368-1,UL508,Complies with DEN-AN|| ||**CONDUCTED NOISE**<br>~~|Po~~||Complies with FCC-B,VCCI-B,CISPR22-B,EN55011-B,EN55022-B|| ||**HARMONIC ATTENUATOR**<br>~~Po~~||Complies with IEC61000-3-2(Class A) *5|| |**OTHERS**|**CASE SIZE**<br>*6 <br>~~Jo~~||38X124X117mm(WXHXD) [1.5X4.88X4.61 inches]|| ||**WEIGHT**<br>~~Po~~||580gmax|| ||**COOLING METHOD**<br>~~Po~~||Convection|| **KL-2** www.cosel.co.jp/en/ December 27, 2022 ## **KL series** ## **Block diagram** **==> picture [449 x 231] intentionally omitted <==** **----- Start of picture text -----**<br> FUSE<br>250V 4A INRUSH<br>NOISE<br>AC IN 85 264V RECTIFIER CURRENT<br>FILTER<br>LIMIT<br>PE<br>BOOSTER CURRENT<br>INDUCTOR SENSING TRANSFORMER<br>RECTIFIER RECTIFIER<br>AND INVERTER AND DC OUT<br>FILTER FILTER<br>INVERTER<br>CURRENT<br>SENSING Photocoupler<br>CONTROL<br>Photocoupler<br>CONTROL OVER VOLTAGE<br>PROTECTION<br>**----- End of picture text -----**<br> ## **External view** <KLEA120F(Euro Style I/O Terminals)> <KLNA120F(Barrier Blocks Style I/O Terminals)> **==> picture [502 x 186] intentionally omitted <==** **----- Start of picture text -----**<br> 9.5 6.4 111.2 9 10 6-M4 2 111.2<br>[0.37] [0.25] [4.38] [0.35] [0.39] [0.08] [4.38]<br>TB2 TB2<br>+VOUT +VOUT<br>-VOUT -VOUT<br>LED (DC_OK) LED(DC_OK)<br>Output voltage Name plate Output voltage Name plate<br>adjustable potentiometer adjustable potentiometer<br>AC(L)<br>AC(L)<br>AC(N)<br>PE AC(N)<br>PE<br>TB1 TB1<br>11.2 117 11.2 117<br>[0.44]9.5 9.5 [4.61]121.2 [0.44]9 10 [4.61]121.2<br>[0.37] 38[0.37] [4.77] [0.35] 38[0.39] [4.77]<br>[1.5] [1.5]<br>8.6 [0.34]<br>6.6 [0.26]<br>14.6 [0.57]<br>109 [4.29] 124 [4.88] 113.2 [4.46] 133.5 [5.26] 105.4 [4.15] 124 [4.88]108.9 [4.29] 133.5 [5.26]<br>69 [2.72] ] (65.7) [2.59] 69 [2.72] (65.7) [2.59]<br>6.6 [0.26 14.6 [0.57]<br>7.5 [0.3] 4.2 ][0.17 9.3 [0.37] 0.5 [0.02]<br>**----- End of picture text -----**<br> Tolerance : ±1.5 [±0.06] Weight : 580g max PCB Material/thickness : FR-4 / 1.6mm [0.06] Chassis material : Aluminum Case material : Stainless steel Din rail attachment material : Aluminum, Stainless steel, Nylon Dimensions in mm, [ ] = inches Screw tightening torque : 1N m max Tolerance : ±1.5 [±0.06] Weight : 580g max PCB Material/thickness : FR-4 / 1.6mm [0.06] Chassis material : Aluminum Case material : Stainless steel Din rail attachment material : Aluminum, Stainless steel, Nylon Dimensions in mm, [ ] = inches Screw tightening torque : 1.6N m max **KL-3** www.cosel.co.jp/en/ December 27, 2022 **AC-DC Power Supplies DIN Rail Type Ordering information - KL** O **A 240 F** OO **-** O **KLEA/KLNA240F** 1 2 3 4 5 6 ~~Ye —~~ 1Series name R **Example recommended EMI/EMC filterNAC-06-472-D** KLE : Euro Style I/O Terminals KLN : Barrier Blocks Style I/O Terminals 2Single output 3Output wattage UL508 45Universal inputOutput voltage 6Option iF j High voltage pulse noise type : NAP series C : with Coating Low leakage current type : NAM series N2 : Screw mounting *A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. ||**MODEL**<br>~~a~~|**MODEL**<br>~~a~~|**KLEA/KLNA240F-24**|**KLEA/KLNA240F-48**| |---|---|---|---|---| |**INPUT**|**VOLTAGE[V]**<br>~~Po~~||AC85 - 264 1f (Refer to“Derating”) *8|| ||**CURRENT[A]**<br>~~oe~~|**ACIN 115V**<br>~~oe~~|2.4typ|| |||**ACIN 230V**<br>~~oe~~|1.3typ|| ||**FREQUENCY[Hz]**||50 / 60(45 - 66)|| ||**EFFICIENCY[%]**<br>~~re~~|**ACIN 115V**<br>~~re~~|88typ|| |||**ACIN 230V**<br>~~re~~|90typ|| ||**POWER FACTOR**<br>~~PE~~|**ACIN 115V**<br>~~PE~~|0.98typ|| |||**ACIN 230V**<br>~~PE~~|0.90typ|| ||**INRUSH CURRENT[A]**<br>*1<br>~~oe~~|**ACIN 115V**<br>~~oe~~|20typ (Io=100%)(at cold start Ta=25C)|| |||**ACIN 230V**<br>~~oe~~|40typ (Io=100%)(at cold start Ta=25C)|| ||**LEAKAGE CURRENT[mA]**||0.45 / 0.75max(ACIN 100V / 240V 60Hz,Io=100%,Accordingto IEC62368-1 and DEN-AN)|| |**OUTPUT**<br>~~Po~~<br>~~_~~<br>~~po~~<br>~~a~~|**VOLTAGE[V]**<br>~~PO~~||24<br>~~PO~~|48| ||**CURRENT[A]**<br>~~a~~||10|5| ||**LINE REGULATION[mV]**<br>*2 <br>~~es~~||96max<br>~~es~~|192max| ||**LOAD REGULATION[mV]**<br>*2 <br>~~Ge~~<br>~~Po~~||150max<br>~~Ge~~|300max| ||**RIPPLE[mVp-p]**<br>*3 <br>~~Po~~<br>~~————————~~|**0 to +70**C <br>~~——————~~|150max<br>~~——————~~|150max| |||<br>**-20 - 0**C<br>~~——————~~|240max<br>~~——————~~|240max| ||**RIPPLE NOISE[mVp-p]** *3 <br>~~Po~~<br>~~————————~~<br>~~ee~~|**0 to +70**C <br>~~——————~~|180max<br>~~——————~~|180max| |||<br>**-20 - 0**C<br>~~——————~~<br>~~ee~~|300max<br>~~——————~~<br>~~ee~~|300max<br>~~ee~~| ||**TEMPERATURE REGULATION[mV]**<br>~~————————~~<br>~~ee~~<br>~~_~~<br>~~tt~~<br>~~po~~|**0 to +70**C <br>~~——————~~<br>~~ee~~<br>~~tt~~|240max<br>~~——————~~<br>~~ee~~<br>~~tt~~|480max<br>~~ee~~| |||**-20 to +70**C <br>~~ee~~<br>~~tt~~<br>~~po~~|290max<br>~~ee~~<br>~~tt~~<br>~~ed~~|600max<br>~~ee~~| ||**DRIFT[mV]**<br>*4 <br>~~ee~~<br>~~_~~<br>~~tt~~<br>~~po~~||96max<br>~~ee~~<br>~~tt~~<br>~~ed~~|192max<br>~~ee~~| ||**START-UP TIME[ms]**<br>~~_~~<br>~~tt~~<br>~~po~~||500typ (ACIN 115V,Io=100%)<br>~~tt~~<br>~~ed~~|| ||**HOLD-UP TIME[ms]**<br>~~po ~~<br>~~po~~<br>~~a~~||20typ (ACIN 115V,Io=100%)<br> ~~ed~~|| ||**OUTPUT VOLTAGE ADJUSTMENT RANGE[V]**<br>~~a~~||21.60 to 26.40|43.20 to 52.80| ||**OUTPUT VOLTAGE SETTING[V]**<br>~~a~~<br>~~RG~~||24.00 to 24.96<br>~~RG~~|48.00 to 49.92| |**PROTECTION**<br>**CIRCUIT AND**<br>**OTHERS**|**OVERCURRENT PROTECTION**<br>~~Po~~||Works over 105% of ratingand recovers automatically|| ||**OVERVOLTAGE PROTECTION[V]**<br>~~es~~||27.60 to 33.60<br>~~es~~|54.00 to 67.20| ||**DC_OK LAMP**<br>~~Po~~||LED(Green)|| |**ISOLATION**|**INPUT-OUTPUT**<br>~~Po~~||AC3,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin(At Room Temperature)|| ||**INPUT-PE**<br>~~po~~||AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin(At Room Temperature)|| ||**OUTPUT-PE**<br>~~Po~~||AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin(At Room Temperature)|| |**ENVIRONMENT**|**OPERATING TEMP.,HUMID.AND ALTITUDE**<br>~~Po~~||-20 to +70C,20 - 90%RH(Non condensing),Type tested for -40Cstart-up (Refer to“Derating”)|| ||**STORAGE TEMP.,HUMID.AND ALTITUDE**<br>~~Po~~||-30 to +85C,20 - 90%RH(Non condensing)|| ||**VIBRATION**<br>*7 <br>~~Po~~||10 - 55Hz,19.6m/s2 (2G),3minutesperiod,60 minutes alongZ axis(Non operating,mounted on DIN Rail)|| ||**IMPACT**<br>~~Po~~||196.1m/s2 (20G),11ms,once each X,Y and Z axis(Packingstate)|| |**SAFETY AND**<br>**NOISE**<br>**REGULATIONS**|**AGENCY APPROVALS**<br>~~Po~~||UL60950-1,C-UL(CSA60950-1),EN62368-1,UL508,Complies with DEN-AN|| ||**CONDUCTED NOISE**<br>~~po~~||Complies with FCC-B,VCCI-B,CISPR22-B,EN55011-B,EN55022-B|| ||**HARMONIC ATTENUATOR**<br>~~Po~~||Complies with IEC61000-3-2(Class A) *5|| |**OTHERS**|**CASE SIZE**<br>*6 <br>~~Po~~||50X124X117mm(WXHXD) [1.97X4.88X4.61 inches]|| ||**WEIGHT**<br>~~Po~~||750gmax|| ||**COOLING METHOD**<br>~~Po~~||Convection|| **KL-4** www.cosel.co.jp/en/ December 27, 2022 ## **KL series** ## **Block diagram** **==> picture [449 x 231] intentionally omitted <==** **----- Start of picture text -----**<br> FUSE<br>250V 8A INRUSH<br>NOISE<br>AC IN 85 264V RECTIFIER CURRENT<br>FILTER<br>LIMIT<br>PE<br>BOOSTER CURRENT<br>INDUCTOR SENSING TRANSFORMER<br>RECTIFIER RECTIFIER<br>AND INVERTER AND DC OUT<br>FILTER FILTER<br>INVERTER<br>CURRENT<br>SENSING Photocoupler<br>CONTROL<br>Photocoupler<br>CONTROL CONTROL OVER VOLTAGE<br>PROTECTION<br>**----- End of picture text -----**<br> ## **External view** <KLEA240F(Euro Style I/O Terminals)> <KLNA240F(Barrier Blocks Style I/O Terminals)> **==> picture [498 x 196] intentionally omitted <==** **----- Start of picture text -----**<br> 15.5[0.61] [0.25]6.4 111.2[4.38] [0.39]10 [0.39]10 7-M4 [0.08]2 111.2[4.38]<br>TB2 TB2<br>+VOUT<br>+VOUT<br>-VOUT<br>-VOUT<br>LED(DC_OK) LED(DC_OK)<br>Output voltage Name plate Output voltage Name plate<br>adjustable potentiometer adjustable potentiometer<br>AC(L) AC(L)<br>AC(N) AC(N)<br>PE PE<br>TB1 TB1<br>11.6 117 11.6 117<br>[0.46] 15.5[0.61] [0.37]9.5 [4.61]121.2[4.77] [0.46] [0.59]15 50[0.39]10 [4.61]121.2[4.77]<br>[1.97]50 [1.97]<br>8.6 [0.34]<br>6.6 [0.26]<br>4.61 [0.57]<br>109 [4.29] 124 [4.88] 113.2 [4.46] 133.5 [5.26] 105.4 [4.15] 124 [4.88]108.9 [4.29] 133.5 [5.26]<br>69 [2.72] (65.7) [2.59] 69 [2.72] (65.7) [2.59]<br>6.6 [0.26]<br>14.6 [0.57]<br>7.5 [0.3] 4.2 [0.17] 9.3 [0.37] 0.5 [0.02]<br>**----- End of picture text -----**<br> Tolerance : ±1.5 [±0.06] Weight : 750g max PCB Material/thickness : FR-4 / 1.6mm [0.06] Chassis material : Aluminum Case material : Stainless steel Din rail attachment material : Aluminum, Stainless steel, Nylon Dimensions in mm, [ ] = inches Screw tightening torque : 1N m max Tolerance : ±1.5 [±0.06] Weight : 750g max PCB Material/thickness : FR-4 / 1.6mm [0.06] Chassis material : Aluminum Case material : Stainless steel Din rail attachment material : Aluminum, Stainless steel, Nylon Dimensions in mm, [ ] = inches Screw tightening torque : 1.6N m max **KL-5** www.cosel.co.jp/en/ December 27, 2022 ## **KL-series** ## **Terminal Blocks** **==> picture [398 x 374] intentionally omitted <==** **----- Start of picture text -----**<br> ¿ KLEA120F ¿ KLNA120F<br>4 4<br>5 5<br>6 6<br>7 7<br>3 3<br>2 2<br>1 1<br>¿ KLEA240F ¿ KLNA240F<br>4 4<br>5 5<br>6 6<br>7 7<br>3 3<br>2 2<br>1 1<br>Terminal Terminal<br>Function<br>Number Name<br>1 PE Protective earth Terminal<br>2 AC (N)<br>Input Terminals<br>3 AC (L)<br>4 +VOUT +Output Terminals<br>5 -VOUT -Output Terminals<br>6 DC_OK LED for output voltage confirmation<br>7 TRM Adjustment of output voltage<br>**----- End of picture text -----**<br> ## **Assembling and Installation Method** ## Installation method - ¡ About DIN-Rail Attachment available with DIN EN60715 TH 35 (35×7.5mm or 35×15mm) (Top hat shaped DIN rail) - ¡ Below shows mounting orientation. If install other then standard mounting orientation (A), please fix the power supply for withstand the impact and vibration. - ¡ When you mount a power supply on a DIN rail, have the area marked A catch one side of the rail and push the unit to the direction of B. To remove the power supply from the rail, either push down the area marked C or insert a tool such as driver to the area marked D and pull the unit apart from the rail. - When you couldn’t remove the unit easily, push down the area marked C while lightly pushing the unit to the direction of E. **==> picture [214 x 276] intentionally omitted <==** **----- Start of picture text -----**<br> INPUT OUTPUT<br>OUTPUT<br>INPUT<br>DIN rail<br>INPUT OUTPUT<br>(A) Standard (B) (C)<br>INPUT OUTPUT OUTPUT INPUT<br>(D) (E)<br>C<br>E<br>A<br>B<br>D<br>**----- End of picture text -----**<br> **KL-6** www.cosel.co.jp/en/ December 27, 2022 ## **KL-series** ## **Assembling and Installation Method** - ¡ Shown below the notes about installation clearance of a unit. - 1 Installation clearance at above and below the unit. - Please have clearance of at least 25mm above and below the unit to avoid heat accumulation. - 2 Installation clearance at the side of the unit. - Please have clearance of at least 5mm side the unit to insulating the internal components. However, refer to right figure, if adjacent device of the unit (including power supply) is a heat source. **==> picture [239 x 201] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>Convection 2 25mm<br>or more<br>¡<br>1<br>Convection 25mm<br>or more<br>Adjacent device of the unit<br>No. Model<br>Non-heat source He at source( * )<br>1 KLEA120F, KLNA120F 15mm or more 25mm or more<br>2 KLEA240F, KLNA240F 15mm or more 25mm or more<br>* Reference value when same power units are adjacent.<br>**----- End of picture text -----**<br> ## **Derating** ## Derating curve for input voltage **==> picture [118 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> [%]<br>100<br>80<br>85 100 [AC V]<br>Load Factor<br>**----- End of picture text -----**<br> ## Ambient temperature derating ¡ The operative ambient temperature as different by input voltage. Derating curve is shown below. ¡ In the hatched area,the specification of Ripple,Ripple Noise is different from other area. - ¡ Derating Curve (Convection) - ¡ Refer to instruction manual 3 for Ambient temperature measurement point. ## ¿ KLEA120F, KLNA120F **==> picture [198 x 242] intentionally omitted <==** **----- Start of picture text -----**<br> (D), (E) (C) (B) (A)<br>100<br>80<br>60<br>Vin=AC85V - 170V *<br>40<br>30<br>20<br>0<br>-30 -20 -10 0 10 20 25 30 40 45 50 60 65 70 80<br>Ambient Temperature [ C ]<br>* Derating curve depend on input voltage is required.<br>KLEA240F, KLNA240F<br>(D), (E) (C) (B) (A)<br>100<br>80<br>60<br>40<br>20<br>Vin=AC85V - 170V *<br>0<br>-30 -20 -10 0 10 15 20 30 40 45 50 60 65 70 80<br>Ambient Temperature [ C ]<br>Load factor [%]<br>Load factor [%]<br>**----- End of picture text -----**<br> - Derating curve depend on input voltage is required. ## ¿ KLEA240F, KLNA240F **==> picture [196 x 240] intentionally omitted <==** **----- Start of picture text -----**<br> (D), (E) (C) (B) (A)<br>100<br>80<br>70<br>60<br>Vin=AC170V - 264V<br>40<br>30<br>20<br>0<br>-30 -20 -10 0 10 20 30 40 45 50 55 60 65 70 80<br>Ambient Temperature [ C ]<br>(D), (E) (C) (B) (A)<br>100<br>80<br>60<br>40<br>Vin=AC170V - 264V<br>20<br>0<br>-30 -20 -10 0 10 20 25 30 35 40 50 55 60 65 70 80<br>Ambient Temperature [ C ]<br>Load factor [%]<br>Load factor [%]<br>**----- End of picture text -----**<br> - Derating curve depend on input voltage is required. **KL-7** www.cosel.co.jp/en/ December 27, 2022 **KL-series** ## ~~ee~~ **Derating** ¡ Derating Curve (Forced air) ¡ Use the temperature measurement point as shown in instruction manual 3. Please use at the temperature dose not exceed the values in instruction manual 3. ## ¿ KLEA120F, KLNA120F ## ¿ KLEA240F, KLNA240F **==> picture [454 x 109] intentionally omitted <==** **----- Start of picture text -----**<br> (A) - (E) (A) - (E)<br>100 100<br>80 80<br>WATT VAT<br>60 60<br>WZ Wy<br>Vin=AC85V - 264V V Vin=AC85V - 264V<br>40 Forced air 40 Forced air<br>30<br>20 Wo e e t 20 a<br>E EE Wy +44<br>0 0<br>-30 =777/777/7/4 -20 -10 0 10 20 30 40 50 60 70 80 -30 V -20 -10 0 A 10 20 30 40 T 50 60 70 80<br>Ambient Temperature [ C ] Ambient Temperature [ C ]<br>Load factor [%] Load factor [%]<br>**----- End of picture text -----**<br> ## **Instruction Manual** —— ~~EEE~~ ◆ It is neccessary to read the “Instruction Manual” and “Before using our product” before you use our product. Instruction Manual https://www.cosel.co.jp/redirect/catalog/en/KL/ Before using our product https://en.cosel.co.jp/technical/caution/index.html **KL** **NOTICE** ## **Basic Characteristics Data** ~~EEE~~ |Model|Circuit method|Switching<br>frequency<br>[KLz]|Input<br>current<br> [A]*1|Rated<br>input fuse|Inrush<br>current<br>protection<br>circuit|PCB/Pattern|PCB/Pattern|PCB/Pattern|Series/Parallel<br>operation availability|Series/Parallel<br>operation availability| |---|---|---|---|---|---|---|---|---|---|---| |||||||Material|Single<br>sided|Double<br>sided|Series<br>operation|Parallel<br>operation| |KLEA120F<br>KLNA120F|Active filter|40 - 160|1.2|250V 4A|Thermistor|FR-4||Yes|Yes|No| ||Flyback converter|20 - 150*2||||||||| |KLEA240F<br>KLNA240F|Active filter|50 - 70|2.4|250V 8A|Thermistor|FR-4||Yes|Yes|No| ||Forward converter|130||||||||| - *1 The value of input current is at ACIN 115V and 100%. - *2 Burst operation at light loading, frequency is change by use condition. Please contact us about detail. **KL-8** www.cosel.co.jp/en/ December 27, 2022
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →