KAX-50
Fuse, Industrial / Power, 50 A, 660 V, 660 V, 21mm x 81mm, 0.8" x 3.2"
- Manufacturer: OMEGA
- Product type: Industrial & Electrical Power Fuses
- SVHC: Boric acid (14-Jun-2023)
- Fuse Current: 50A
- Product Range: -
- Fuse Size Metric: 21mm x 81mm
- Fuse Size Imperial: 0.8" x 3.2"
- Voltage Rating VAC: 660V
- Voltage Rating VDC: 660V
- Blow Characteristic: Fast Acting
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 222.02 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Solid State Relays High Reliability, Vdc Input/ Vac Output, Vac Input/Vac Output** ## **SSRL Series** **SSRL240AC10 shown actual size.** - U **Current Ratings to 100 A** - U **Multi-Million Cycle Life** - U **Compatible with Temperature Controllers** - U **Solid-State, SCR Design** U **Zero Voltage Switching** - U **Control AC Lines to 660 Vac** - U **AC and DC Control Signal Models** - U **LED Input Status Indicator** The SSRL Series solid state relays are used to control large resistance heaters in conjunction with temperature controllers. Solid state relays are SPST, normally open switching devices with no moving parts, capable of millions of cycles of operation. By applying a control signal, an SSR switches “on” the AC load current, just as the moving contacts do on a mechanical contactor. Three-phase loads can be controlled using 2 or 3 SSR’s. Use 3 SSR’s for “Y” or “star” 3-phase loads using a neutral line. Two SSR’s will control “delta” loads with no neutral line. Three solid state relays are also used when there is no neutral load to provide redundancy and extra assurance of control. “Switching” takes place at the 0 voltage crossover point of the alternating current cycle. Because of this, no appreciable electrical noise is generated, making SSR’s ideal for environments where there are apparatuses susceptible to RFI. **==> picture [323 x 263] intentionally omitted <==** **----- Start of picture text -----**<br> AC output SSR used with temperature controller with DC voltage SSR driver output<br>Temperature Control Load<br>Controller Side DC Input Side Heater<br>4 SSR 1<br>Vac Vac<br>3 2<br>0 or 5 Vdc,<br>Fast Blow<br> Typically Fuse<br>AC output SSR used with temperature controller with mechanical relay output<br>Temperature Control Load<br>Controller Side AC Input Side Heater<br>4 SSR 1<br>Vac Vac<br>3 2<br>Fast Blow<br>Vac Fuse<br>Driving<br>SSR<br>AC output SSR used with temperature controller with triac output<br>Control Side<br>Temperature Load Load<br>Controller AC Input Side Heater<br> Resistor 4 SSR 1<br>Vac Vac<br>3 2<br>Fast Blow<br>Vac Fuse<br>Driving<br>SSR<br>Typical Applications<br>**----- End of picture text -----**<br> **Capacitance:** 8 pF, input to output (max) **Line Frequency Range:** 47 to 63 Hz **Turn-On Time:** 20 ms, AC; 05 cycle, DC **Turn-Off Time:** 30 ms, AC; 05 cycle, DC ## **Common Specifications** **Operating Temperature:** -20 to 80°C (-5 to 175°F) **Storage Temperature:** -40 to 80°C (-40 to 175°F) **Isolation:** 4000 Vrms, input to output; 2500 Vrms input/output to ground ## **Output Specifications for Vac and Vdc Input Models** |**Specifications**|**10 Amp 25 Am**|**25 Amp**|**50 Amp**|**75 Amp 100 Am**|**100 Amp**| |---|---|---|---|---|---| |**Max On-State Current**|10 A|25 A|50 A|75 A|100 A| |**Min On-State Current**|100 mA||||| |**Max 1-Cycle Surge **|150 A|300 A|750 A|1000 A|1200 A| |**Max 1 sec Surge **|30 A|75 A|150 A|225 A|300 A| |**12T (60 Hz), A2sec**|416|937|2458|5000|6000| **P-111** **P** These SSR’s are of the twin SCR type, inherently more reliable and capable of higher overloads before failure than triacs. Heat is developed in a solid state relay due to the nominal voltage drop across the switching device. To dissipate the heat, an SSR must be mounted on a finned heat sink or aluminum plate. An SSR should be located where the ambient temperature is relatively low, since the current switching rating is lowered as the temperature increases. Another SSR characteristic is a small leakage current across the output when the relay is open. Because of this, a voltage will always exist on the load side of the device In comparing SSR’s with mechanical contactors, the SSR has a cycle life many times that of a comparably priced contactor. However, SSR’s are more prone to failure due to overload and improper initial wiring. Solid state relays can fail, contact closed, on overload circuits. It is essential that a properly rated, fast blowing I[2] T fuse be installed to protect the load circuit **SSRL240DC50 solid state relay shown smaller than actual size with FHS-2 heat sink. See P-114 for more information.** Finned heat sinks are anodized fabrications that come complete with tapped mounting holes and screws. See thermal rating curves and ordering instructions for proper selection. ## **FHS Heat Sink Dimensions and Specifications** **==> picture [498 x 195] intentionally omitted <==** **----- Start of picture text -----**<br> FHS-6 Heat Sink Dimensions: mm (in)<br>139.7<br>SSR MOUNTING HOLES (2) 8-32 THDS. (5.50)<br>FHS-1 and FHS-2 Heat Sink Dimensions: mm (inch) (2.62)66.5 114.3 (4.50) 12.7(0.50)<br>50.8 (2.000) (0.167)4.241 ——— AB po 115.8<br>(4.56)<br>S S = CENTERS<br>CL (4.75)120.7 CL (SCREWS)#6<br>50.8 8-32 TH'D 120.65<br>(0.200)5.08 (2.000) _ (4.416)112.17 1] 2 Places (4.750) | 34<br>| ————|<br>=L (0.062)1.5748 (0.250)6.35 SSS<i C (1.875)47.625 = (0.125)3.175 R LL END VIEW(1.44)36.6 | (TYP.)5.6(0.22) a (TYP.)(0.20)5.1 47.5(1.87)TOP VIEW (1.81)46.0 —|<br> Model No. A B C Thermal Rating<br> FHS-1 3.00" 2.50" 0.56" 2°C/W<br> FHS-2 5.50" 5.00" 1.81" 1.2°C/W<br>**----- End of picture text -----**<br> ## **SSR240 Series Electrical Specifications** |**Model No.**|**Type **||**Input-Control Signal**|**Input-Control Signal**|**Input-Control Signal**|**Output**| |---|---|---|---|---|---|---| |||**Control**<br>**Signal**<br>**Voltage **|**Control**<br>**Signal**<br>**Turn-On**|**Control**<br>**Signal**<br>**Turn-Off**|**Max**<br>**Input**<br>**Current**|**Peak**<br>**Voltage***<br>**(60 s Max)**| |**SSRL240AC10**<br>**SSRL240AC25**<br> **SSRL240AC50**<br> **SSRL240AC75**<br> **SSRL240AC100**|AC<br>control<br>signal|90 to 280 Vac|90 Vac|10 Vac|10 mA|800V| |**SSRL240DC10**<br>**SSRL240DC25**<br> **SSRL240DC50**<br> **SSRL240DC75**<br> **SSRL240DC100**|DC<br>control<br>signal|3 to 32 Vdc|3 Vdc|1 Vdc|14 mA|800V| |**SSRL660AC50**<br> **SSRL660AC75**<br> **SSRL660AC100**|AC<br>control<br>signal|90 to 280 Vac|90 Vac|10 Vac|10 mA|1200V| |**SSRL660DC50**<br> **SSRL660DC75**<br> **SSRL660DC100**|DC<br>control<br>signal|4 to 32 Vdc|4 Vdc|1 Vdc|14 mA|1200V| _*****[ Transients above table value should be suppressed.]_ **P-112** **==> picture [509 x 450] intentionally omitted <==** **----- Start of picture text -----**<br> SSR-10 AMP SSR-25 AMP SSR-50 AMP<br>10.0 25.0 50.0<br>3.0°C/W<br>8.0 20.0 40.0<br>6.0 15.0 30.0<br>4.0 10.0 20.0<br>2.0 5.0 10.0<br>0.0 0.0 0.0<br>20 30 40 50 60 70 80 20 30 40 50 60 70 80 20 30 40 50 60 70 80<br>AMBIENT TEMPERATURE (°C) AMBIENT TEMPERATURE (°C) AMBIENT TEMPERATURE (°C)<br>SSR-75 AMP SSR-100 AMP<br>75.0 100.0<br>90.0<br>60.0 80.0<br>70.0<br>45.0 60.0<br>50.0<br>30.0 40.0<br>30.0<br>15.0 20.0<br>10.0<br>0.0 0.0<br>20 25 30 35 40 45 50 55 60 65 70 75 80 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80<br>AMBIENT TEMPERATURE (°C) AMBIENT TEMPERATURE (°C)<br>57 SSR-125 AMP<br>(0.275)7 (2.250) Dimensions: 125.0<br>43<br>(1.700) mm (inch) 112.5<br>100.0<br>87.5<br>45<br>(1.750) 75.0<br>INPUT 28 OUTPUT<br>(1.100) 62.5<br>50.0<br>37.5<br>25.0<br>12.5<br>0.0<br>0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80<br>AMBIENT TEMPERATURE (°C)<br> 11 11<br>(0.450) SQ. (0.480) SQ.<br>47<br>(1.850)<br>1.5°C/W<br>1.0°C/W<br>1.0ºC/W 1.0°<br>C/W<br>0.7°<br>C/W<br>0.7°<br>0.7° C/W<br>C/W<br>2.0°C/W<br>0.5°<br>C/W<br>3.0°C/W<br>0.5°<br>C/W<br>0.4°<br>C/W<br>1.5°C/W<br>0.5°<br>C/W0.4°<br>C/W<br>2.0°C/W 1.0°C/W<br>LOAD CURENT (AMPERES) LOAD CURENT (AMPERES) 1.5°C/W1.0°C/W LOAD CURENT (AMPERES) 0.7°C/W°C/W0.5<br>LOAD CURENT (AMPERES) LOAD CURENT (AMPERES)<br>21<br>(0.470)<br>22<br>(0.870) 20<br>(0.785)<br>LOAD CURENT (AMPERES)<br>6<br>(0.250)<br>**----- End of picture text -----**<br> **SSR240 Series Output-Vac Load Specifications** |**SSR240 Series Output-V**|**SSR240 Series Output-V**|**ac Load Specifications**|**ac Load Specifications**|**ac Load Specifications**|**ac Load Specifications**|**ac Load Specifications**|**ac Load Specifications**| |---|---|---|---|---|---|---|---| ||**eries Output-V**||||||| |<br>**N**<br>**A**<br>**Model Number**<br>**V**||**ominal**<br>**C Line**<br>**oltage **|**Nominal**<br>**Load**<br>**Current**|**Maximum**<br>**Contact**<br>**Voltage Drop**|**Maximum Off-State Leakage**<br> **(25°C Maximum Ambient)**||| ||**N**<br>||||||| ||||||**120 Vac**|**240 Vac**|**440 Vac**| |**SSRL240AC10**<br> **SSRL240AC25**<br> **SSRL240AC50**<br>24 t<br> **SSRL240AC75**<br> **SSRL240AC100**||o 280 Vac|10 A<br>25 A<br>50 A<br>75 A<br>100 A|1.6V|0.1 mA|0.1 mA|N/A| |**SSRL240DC10**<br> **SSRL240DC25**<br> **SSRL240DC50**<br>24 t<br> **SSRL240DC75**<br> **SSRL240DC100**||o 280 Vac|10 A<br>25 A<br>50 A<br>75 A<br>100 A|1.6V|0.1 mA|0.1 mA|N/A| |**SSRL660AC50**<br> **SSRL660AC75**<br>48 t<br> **SSRL660AC100**||o 660 Vac|50 A<br>75 A<br>100A|1.6V|0.25 mA|0.25 mA|0.25 mA| |**SSRL660DC50**<br> **SSRL660DC75**<br>48 t<br> **SSRL660DC100**||o 660 Vac|50 A<br>75 A<br>100 A|1.6V|0.25 mA|0.25 mA|0.25 mA| **P-113** **P** **All models shown smaller than actual size.** **BS-101 fuse blockshown with KAX-50 fuse.** **==> picture [101 x 23] intentionally omitted <==** **----- Start of picture text -----**<br> FB-1, FB-2,<br>and FB-3 fuse blocks<br>shown with KAX-25 fuses.<br>**----- End of picture text -----**<br> ## **How to Order:** ## **Fuses** |**To Order**|**To Order**|**To Order**| |---|---|---| |**Model No. Capacity**|**Model No. Capacity**|**Dimensions (Dia. x L)**| |**KAX-10**|10 A|14 x 51 mm(0.6 x 2")| |**KAX-25**|25 A|14 x 51 mm(0.6 x 2")| |**KAX-30**|30 A|14 x 51 mm(0.6 x 2")| |**KAX-50**|50 A|21 x 81 mm(0.8 x 3.2")| |**KAX-70**|70 A|31 x 92 mm(1.2 x 3.6")| |**KBH-50**|50 A|18 x 81 mm(0.7 x 3.2")| |**KBH-70**|70 A|19 x 92 mm (0.7 x 3.6")| ## **Fuse Blocks** ## **To Order** |**To Order**|**To Order**|**To Order**| |---|---|---| |**Model**<br>**No.**|**No. of**<br>**Fuses**|**Compatible Fuses**| |**FB-1**|1|KAX-10, KAX-25, KAX-30| |**FB-2**|2|KAX-10, KAX-25, KAX-30| |**FB-3**|3|KAX-10, KAX-25, KAX-30| |**BS-101**|1|KAX-50, KAX-70, KAX-100,<br>KBH (all models)| - 1) Select solid state relay based on type of control signal (AC or DC) and current switching requirements for resistive load. - 2) Select fast blow (I[2] T) fuse and fuse block. It is essential that a fuse be installed to protect the load circuit. - 3) Select required finned heat sink based on max ambient temperature and thermal rating curve on previous page. |**To Order**|**To Order**|**To Order**| |---|---|---| |**To Order**<br>**Model No.**|**Description **|**Nominal**<br>**Rating**| |**SSRL240AC10**<br>**SSRL240AC25**<br>**SSRL240AC50**<br>**SSRL240AC75**<br> **SSRL240AC100**|AC control<br>signal<br>(280 Vac line)|10 A<br>25 A<br>50 A<br>75 A<br>100A| |**SSRL240DC10**<br>**SSRL240DC25**<br>**SSRL240DC50**<br>**SSRL240DC75**<br> **SSRL240DC100**|DC control<br>signal<br>(280 Vac line)|10 A<br>25 A<br>50 A<br>75 A<br>100A| |**SSRL660AC50**<br>**SSRL660AC75**<br> **SSRL660AC100**|AC control<br>signal <br>(660 Vac line)|50 A<br>75 A<br>100A| |**SSRL660DC50**<br>**SSRL660DC75**<br> **SSRL660DC100**|()<br>DC control<br>signal <br>(660 Vac line)|50 A<br>75 A<br>100A| |**FHS-1**<br>**FHS-2**<br>**FHS-6**|Finned heat sink|2°C/W<br>1.2°C/W<br>0.7°C/W| ## **Shunt Resistors for Controllers with AC SSR (Triac) Output** ## **To Order** |**To Order**||| |---|---|---| |**Model No.***|**Value**|| |**SSRR20-12**<br>**SSRR20-50**|2000Ω, 12 watts<br>2000Ω, 50 watts|, 12 watts<br>, 50 watts| |**SSRR15-12**<br>**SSRR15-50**|1500Ω, 12 watts<br>1500Ω, 50 watts|, 12 watts<br>, 50 watts| ***** _[12 W versions for 120 V circuits; 50 W for 240 V.]_ ## **Accessory** **Model No. Description SSRL-DINRAIL-ADAPT** DIN rail adaptor for 10 A models only _Comes complete with operator’s manual._ _**Note:** Reference SSR330 Series for additional heat sinks._ _**Ordering Examples: SSRL240DC25** , solid state relay,_ _**FHS-2,** finned heat sink,_ _**KAX-25,** fuse, and_ _**FB-1,** fuse block._ _**SSRL240AC10,** solid state relay,_ _**FHS-1,** finned heat sink,_ _**KAX-10,** fuse, and_ _**FB-1,** fuse block._ **P-114**
Updated at April 17, 2026
Omega is a globally recognized leader in the design and manufacture of state-of-the-art products for process measurement and control. Renowned for its engineering expertise, the company provides highly reliable solutions for monitoring critical parameters such as temperature, humidity, pressure, strain, and flow across diverse industrial applications. Our extensive selection of Omega products is focused on the brand's core strengths in sensing and automation technologies. The range features a vast array of high-precision temperature sensors, including industry-standard thermocouples and RTDs, supported by a comprehensive selection of essential sensor accessories. To complement these measurement devices, we offer a substantial lineup of robust temperature controllers and advanced pressure transducers engineered to maintain precise conditions in demanding environments. Beyond primary sensing and control, the Omega portfolio encompasses sophisticated panel instrumentation for clear process visualization, alongside highly accurate force sensors and load cells. The offering is completed by reliable signal converters, data acquisition tools such as dataloggers, and fundamental connectivity components, providing professionals with the specialized equipment necessary to build complete, end-to-end industrial control systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 420,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →