K90PLKQP
VISUAL SIGNAL INDICATOR UNITS
- Manufacturer: BANNER ENGINEERING
- Product type: Visual Signal Indicator Units
- SVHC: No SVHC (15-Jan-2018)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 215.31 € |
| Current stock | 10+ |
| Lead time | 30 days |
K90 Pro Indicator with IO-Link ## Features 90 mm IO-Link Controlled Multicolor RGB Indicator - Bright, uniform indicator light - • IO-Link control allows access to full color, flashing and dimming controls as well as advanced animations - Millions of color possibilities - • 30 mm threaded polycarbonate base • Translucent polycarbonate dome • Rugged IP67 and UL Type 4X and UL Type 13 design • Variety of connector options ## Models **==> picture [482 x 56] intentionally omitted <==** **----- Start of picture text -----**<br> Family Style Housing Control Connector<br>K90 P L K Q<br>Q = Integral 4-pin M12 male quick-disconnect connector<br>P = Pro L = Dome K = IO-Link<br>QP = 150 mm (6 in) PVC-jacketed cable with a 4-pin M12<br>male quick-disconnect connector<br>**----- End of picture text -----**<br> ## Washdown Silicone Cover WC-K90 **==> picture [387 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> Washdown Cover Model Description<br>WC-K90 FDA-grade silicone cover<br>**----- End of picture text -----**<br> ## Installing the Silicone Cover To properly install the FDA-grade silicone cover and achieve an IP69 rating, follow these instructions. 1. Turn the cover inside out. 2. Place the cover on top of the indicator. 3. Roll the cover onto the indicator. 4. Continue rolling the cover down, around the base of the indicator, until the entire light is covered. 5. Mount the indicator and cover assembly to a bracket wide enough to cover the base of the assembly. The cover should be clamped firmly between the indicator and the bracket. NOTE: The FDA-grade silicone cover withstands high pressure, high-temperature washdown, and increases the product rating to IEC IP69. The cover is ECOLAB® certified to withstand aggressive cleaning procedures with chemicals used in the food processing industry. Original Instructions 26-Feb-26 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com p/n: 220947 Rev. C K90 Pro Indicator with IO-Link ## Wiring **==> picture [133 x 74] intentionally omitted <==** **----- Start of picture text -----**<br> bu<br>24 V DC<br>bn<br>bk IO-Link<br>Communication<br>wh<br>Not used<br>**----- End of picture text -----**<br> ## IO-Link® Process Out Data IO-Link is a point-to-point communication link between a master device and a sensor and/or light. It can be used to automatically parameterize sensors or lights and to transmit and/or receive process data. For the latest IO-Link protocol and specifications, please visit www.io-link.com. For the latest IODD files, please refer to the Banner Engineering Corp website at: www.bannerengineering.com. Process Data is transmitted cyclically to the IO-Link device from the IO-Link master. These parameters are written to the K90 acyclically and are used to perform the following functions: NOTE: Additional color shades can be made by adjusting intensity **==> picture [500 x 305] intentionally omitted <==** **----- Start of picture text -----**<br> IO-Link Process Data Out for the K90<br>Name Values<br>Color 1<br>Green, Red, Orange, Yellow, Lime Green, Spring Green, Cyan, Sky Blue, Blue, Violet, Magenta, Rose, White,<br>5 Custom Colors to define<br>Color 2<br>Color Flash Rate (Hz) 0.5, 1.5, 3, 6, 9, 12, Custom Rate to define<br>Color 1 Intensity<br>High, Medium, Low, Custom Intensity to define<br>Color 2 Intensity<br>Animation Mode Steady, Flash, Two-Color Flash, Strobe, Half/Half, Half/Half Rotate, Chase, Demo Mode<br>Rotation Direction Counter Clockwise, Clockwise<br>Animation Control<br>Name Description<br>Flashing Flashes the light at the defined flash rate (50/50 duty cycle)<br>Two-Color Flashing Flashes two colors at the defined flash rate, alternating (50/50 duty cycle)<br>Strobe Strobes the light at the defined flash rate (80/20 duty cycle)<br>Half/Half Show half one color and half another color<br>Half/Half Rotate Animation that shows half one color and half another color while rotating clockwise or counter-clockwise<br>Animation that shows a single spot in one color against a background of another color while rotating clockwise<br>Chase<br>or counter-clockwise<br>Demo Mode Cycles through the defined colors and then through the color spectrum<br>**----- End of picture text -----**<br> For more information see IO-Link Data Reference Guide (p/n 200721). ## Specifications Supply Voltage and Current Connections 18 V DC to 30 V DC Integral 4-pin M12 male quick-disconnect connector, or 150 300 mA maximum at 18 V DC mm (6 in) PVC-jacketed cable with an M12 quick disconnect, depending on model Supply Protection Circuitry Models with a quick disconnect require a mating cordset Protected against reverse polarity and transient voltages Construction Input Response Time Base, Dome, and Nut: Polycarbonate 30 milliseconds maximum while active page 2 of 8 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 26-Feb-26 K90 Pro Indicator with IO-Link ## Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 1.0 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068-2-27 requirements (Shock: 30G 11 ms duration, half sine wave) ## Operating Conditions –40 °C to +50 °C (–40 °F to +122 °F) ## Mounting M30 by 1.5 threaded base, maximum torque 4.5 N·m (40 inch·lbf) Mounting nut included Environmental Rating IP67 Enclosure: UL Type 4X, UL Type 13 90% at +50 °C maximum relative humidity (non-condensing) Storage Temperature: –40 °C to +70 °C (–40 °F to +158 °F) ## Indicator Characteristics ## Required Overcurrent Protection |Color<br>Dominant<br>Wavelength<br>(nm) or<br>Color<br>Temperature<br>(CCT)<br>Color Coordinates(1)<br>Lumen<br>Output<br>(Typical at<br>25 °C)<br>x<br>y|WARNING:Electrical connections must<br>be made by qualified personnel in<br>accordance with local and national<br>electrical codes and regulations.<br>AN| |---|---| |Green<br>530 nm<br>0.161<br>0.705<br>81.2|Overcurrent protection is required to be provided by end| ||product application per the supplied table.| |Red<br>625 nm<br>0.686<br>0.312<br>39.2|Overcurrent protection may be provided with external fusing| |Yellow<br>–<br>0.477<br>0.466<br>98.7|or via Current Limiting, Class 2 Power Supply.<br>Supply wiring leads < 24 AWG shall not be spliced.| |Blue<br>470 nm<br>0.137<br>0.057<br>14.0|For additional product support, go to| |White<br>5950 K<br>0.342<br>0.339<br>107.9<br>Cyan<br>–<br>0.164<br>0.343<br>93.0<br>Magenta<br>–<br>0.404<br>0.186<br>49.9<br>Orange<br>–<br>0.599<br>0.377<br>56.5<br>Lime Green<br>–<br>0.359<br>0.557<br>104.5<br>Spring<br>Green<br>–<br>0.156<br>0.527<br>85.4|www.bannerengineering.com.<br>Supply<br>Wiring<br>(AWG)<br>Required Overcurrent<br>Protection (A)<br>Supply<br>Wiring<br>(AWG)<br>Required Overcurrent<br>Protection (A)<br>20<br>5.0<br>26<br>1.0<br>22<br>3.0<br>28<br>0.8<br>24<br>2.0<br>30<br>0.5| |Sky Blue<br>–<br>0.145<br>0.248<br>85.4<br>Violet<br>–<br>0.216<br>0.095<br>27.7<br>Rose<br>–<br>0.512<br>0.234<br>44.8|Certifications<br>Banner Engineering BV<br>Park Lane, Culliganlaan 2F bus 3<br>1831 Diegem, BELGIUM<br>CE| Turck Banner LTD Blenheim House Blenheim Court Wickford, Essex SS11 8YT GREAT BRITAIN (1) Refer to CIE 1931 chromaticity diagram or color chart, to show equivalent color with indicated color coordinates. ## FCC Part 15 Class B for Unintentional Radiators (Part 15.105(b)) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. (Part 15.21) Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. ## Industry Canada ICES-003(B) This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la norme NMB-3(B). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas occasionner d'interférences, et (2) il doit tolérer toute interférence, y compris celles susceptibles de provoquer un fonctionnement non souhaité du dispositif. © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 3 of 8 26-Feb-26 K90 Pro Indicator with IO-Link ## Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. The measurements provided are subject to change. **==> picture [500 x 267] intentionally omitted <==** **----- Start of picture text -----**<br> Standard Model Model with Washdown Cover<br>87 mm 72.5 mm<br>[3.43”] [2.85”]<br>M30 X 1.5<br>M12 X 1 CL 20 mm<br>[0.79”] (K90 shown in gray)<br>Ø 96.5 mm<br>90 mm [3.80”]<br>1/2-14 NPT<br>[3.54”]<br>Ø 62.0 mm<br>[2.44”]<br>CL<br>CL<br>**----- End of picture text -----**<br> ## Accessories ## Cordsets **==> picture [500 x 199] intentionally omitted <==** **----- Start of picture text -----**<br> 4-Pin Double-Ended M12 Female to M12 Male Cordsets<br>Model Length Style Dimensions Pinout<br>MQDEC-401SS 0.31 m (1 ft) Female<br>MQDEC-403SS 0.91 m (2.99 ft) 1 2<br>40 Typ.<br>MQDEC-406SS 1.83 m (6 ft) [1.58"]<br>MQDEC-412SS 3.66 m (12 ft) 4 3<br>MQDEC-415SS 4.58 m (15 ft) M12 x 1 Male<br>MQDEC-420SS 6.10 m (20 ft) ø 14.5 [0.57"] 2 1<br>Male Straight/Female<br>MQDEC-430SS 9.14 m (30.2 ft) Straight 44 Typ.<br>[1.73"]<br>3 4<br>1 = Brown<br>M12 x 1 2 = White<br>MQDEC-450SS 15.2 m (49.9 ft) ø 14.5 [0.57"] 3 = Blue4 = Black<br>**----- End of picture text -----**<br> page 4 of 8 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 26-Feb-26 K90 Pro Indicator with IO-Link ## Brackets ## SMB30A - Right-angle bracket with curved slot for versatile orientation - • Clearance for M6 (¼ in) hardware - Mounting hole for 30 mm sensor - • 12-gauge stainless steel • CAD Files: DXF, PDF, IGS, STP Hole center spacing: A to B=40 Hole size: A=ø 6.3, B= 27.1 × 6.3, C=ø 30.5 **==> picture [67 x 66] intentionally omitted <==** **----- Start of picture text -----**<br> 45<br>C<br>61<br>B<br>A<br>69<br>**----- End of picture text -----**<br> ## SMB30FVK - V-clamp, flat bracket and fasteners for mounting to pipe or extensions - • Clamp accommodates 28 mm dia. tubing or 1 in. square extrusions • 30 mm hole for mounting sensors • CAD Files: DXF, PDF, IGS, STP **==> picture [61 x 23] intentionally omitted <==** **----- Start of picture text -----**<br> 46<br>118<br>A<br>**----- End of picture text -----**<br> Hole size: A=ø 31 - A - • V-clamp, right-angle bracket and fasteners for mounting sensors to pipe or extrusion • Clamp accommodates 28 mm dia. tubing or 1 in. square extrusions 46 • 30 mm hole for mounting sensors • CAD Files: DXF, PDF, IGS, STP 57 90 ## SMB30RAVK Hole size: A=ø 30.5 ## SMBAMS30P - 45 - • Flat SMBAMS series bracket • 30 mm hole for mounting sensors C • Articulation slots for 90°+ rotation • 12-gauge 300 series stainless steel 93 A • CAD Files: DXF, PDF, IGS, STP B - Hole center spacing: A=26.0, A to B=13.0 Hole size: A=26.8 × 7.0, B=ø 6.5, C=ø 31.0 • Right-angle SMBAMS series bracket 45 • 30 mm hole for mounting sensors C •• Articulation slots for 90°+ rotation12-gauge (2.6 mm) cold-rolled steel 53 A • CAD Files: DXF, PDF, IGS, STP B - Hole center spacing: A=26.0, A to B=13.0 48 Hole size: A=26.8 × 7.0, B=ø 6.5, C=ø 31.0 70 57 - • 12-gauge stainless steel bracket with curved mounting slots for versatile orientation • Clearance for M6 (¼ in) hardware •• Mounting hole for 30 mm sensorCAD Files: DXF, PDF, IGS, STP 57 B C - Hole center spacing: A=51, A to B=25.4 Hole size: A=42.6 × 7, B=ø 6.4, C=ø 30.1 A 67 - • Swivel bracket with 30 mm mounting hole for sensor B • Black reinforced thermoplastic polyester • Stainless steel mounting and swivel locking hardware included 58 • CAD Files: DXF, PDF, IGS, STP - Hole center spacing: A=ø 50.8 Hole size: A=ø 7.0, B=ø 30.0 29 A ## SMBAMS30RA ## SMB30MM ## SMB30SC © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 5 of 8 26-Feb-26 K90 Pro Indicator with IO-Link **==> picture [500 x 294] intentionally omitted <==** **----- Start of picture text -----**<br> SMB30FA<br>83.2<br>• Swivel bracket with tilt and pan movement for precise adjustment<br>• Mounting hole for 30 mm sensor<br>• 12-gauge 304 stainless steel<br>• Easy sensor mounting to extrude rail T-slot<br>• Metric- and inch-size bolt available 36.3 B 68.9<br>• CAD Files: DXF, PDF, IGS, STP A<br>Bolt thread: SMB30FA, A=3/8 - 16 × 2 in; SMB30FAM10, A=M10 - 1.5 × 50<br>Hole size: B=ø 30.1<br>55<br>LMBE12RA35 35<br>• Direct mounting of stand-off pipe, with common bracket type 38.25<br>• Zinc-plated steel<br>• 1/2-14 NPSM nut<br>• Mounting distance from the wall to the center of the 1/2-14 NPSM nut is 35 mm<br>• CAD Files: DXF, PDF, IGS, STP 57<br>Hole center spacing: 20.0<br>2X Ø9<br>65<br>LMBE12RA45 45<br>38.25<br>• Direct mounting of stand-off pipe, with common bracket type<br>• Zinc-plated steel<br>• 1/2-14 NPSM nut<br>• Mounting distance from the wall to the center of the 1/2-14 NPSM nut is 45 mm<br>• CAD Files: DXF, PDF, IGS, STP 81<br>Hole center spacing: 35.0<br>2X Ø11<br>**----- End of picture text -----**<br> All measurements are listed in millimeters [inches], unless noted otherwise. The measurements provided are subject to change. ## Elevated Mount System **==> picture [500 x 316] intentionally omitted <==** **----- Start of picture text -----**<br> Adapter/Cover Model Description<br>SA-M30 polycarbonate - Black •• Streamlined black PC or Gray PC thread coverCovers the outer M30 threads on the light's<br>base<br>• Typically used for the TL70 Tower Light and K90<br>SA-M30C polycarbonate - Gray •• seriesMounting hardware includedCAD files: DXF, PDF, IGS, STP<br>Black Anodized Aluminum, ½ in. Clear Anodized Aluminum, ½ in.<br>Description<br>NPT Pipe Models NPT Pipe Models<br>Adapter/Cover SOP-E12-150A , 150 mm (6 in) long SOP-E12-150AC long , 150 mm (6 in) • Elevated-use stand-off pipe<br>• Threaded at both ends<br>SOP-E12-300A , 300 mm (12 in) SOP-E12-300AC , 300 mm (12 in) • Compatible with most industrial environments<br>long long • CAD Files:<br>Pipe ◦ SOP-E12-150A : DXF, PDF, IGS, STP<br>SOP-E12-600A , 600 mm (24 in) - ◦ SOP-E12-300A : DXF, PDF, IGS, STP<br>long ◦ SOP-E12-600A : DXF, PDF, IGS, STP<br>SOP-E12-900A , 900 mm (36 in) SOP-E12-900AC , 900 mm (36 in) ◦ SOP-E12-900A : DXF, PDF, IGS, STP<br>long long<br>Mounting Mounting Base Model Description<br>Base<br>SA-FFB12 - Black<br>polycarbonate<br>• For use with ½ in. stand-off pipes<br>• 110° rotation<br>• Stainless steel hardware<br>SA-FFB12C polycarbonate - Gray • CAD files: DXF, PDF, IGS, STP<br>**----- End of picture text -----**<br> ## Other Pipes page 6 of 8 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 26-Feb-26 K90 Pro Indicator with IO-Link - 304 Stainless Steel, ½ in. NPT Pipe Models Description SOP-E12-150SS , 150 mm (6 in) long • Elevated-use stand-off pipe • Threaded at both ends - SOP-E12-300SS , 300 mm (12 in) long • Compatible with most industrial environments • CAD Files: - SOP-E12-600SS , 600 mm (24 in) long ◦ SOP-E12-150x : DXF, PDF, IGS, STP ◦ SOP-E12-300x : DXF, PDF, IGS, STP ◦ SOP-E12-600x : DXF, PDF, IGS, STP - SOP-E12-900SS , 900 mm (36 in) long ◦ SOP-E12-900x : DXF, PDF, IGS, STP ## Other Mounting Bases Mounting Base Model Description SA-E12M30 - Black acetal • Streamlined black acetal or white UHMW mounting base adapter/ cover • Adapter from ½ in. NPSM/DN15 pipe to 30 mm (1-3/16 in) drilled hole SA-E12M30C - White UHMW • Mounting hardware included • CAD files: DXF, PDF, IGS, STP Mounting Base Model Description • Die-cast zinc base with black paint • Elevated-use stand-off pipes (½ in, NPSM/DN15) SA-F12 • M5 mounting hardware and nitrile gasket included • CAD files: DXF, PDF, IGS, STP **==> picture [200 x 116] intentionally omitted <==** ## LMB Sealed Right-Angle Bracket Model Description LMB30RA - Black polycarbonate • Direct-Mount Models CAD Files: DXF, PDF, IGS, STP • Bracket kit with base, 30 mm adapter, set screw, LMB30RAC - Gray polycarbonate fasteners, O-rings, and gaskets. CAD Files: DXF, PDF, IGS, STP LMBE12RA - Black polycarbonate • Pipe-Mount Models CAD Files: DXF, PDF, IGS, STP • Bracket kit with base, ½-14 pipe adapter, set screw, fasteners, O-rings, and gaskets LMBE12RAC - Gray polycarbonate • For use with stand-off pipe (listed and sold separately) CAD Files: DXF, PDF, IGS, STP **==> picture [149 x 62] intentionally omitted <==** ## Sun Shield ## K90DS - Use for enhanced visibility in direct sunlight conditions - • Polycarbonate ## Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 7 of 8 26-Feb-26 K90 Pro Indicator with IO-Link the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. page 8 of 8 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 26-Feb-26
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →