K8AKTH11SAC100240
Temperature Monitoring Relay, K8AK Series, Thermocouple, RTD, 100 to 240 Vac, SPDT Relay Output
- Manufacturer: OMRON INDUSTRIAL AUTOMATION
- Product type: Temperature Controllers
- Thermocouple Type:E, J, K, T, Pt100, Pt1000; Operating Temperature Max:55°C; Operating Temperature Min:-20°C; Temperature Accuracy ±:1%; Output Voltage Max:250VAC; Output Voltage Min:-
- Product Range: -
- Thermocouple Type: E, J, K, T, Pt100, Pt1000
- Output Voltage Max: 250VAC
- Output Voltage Min: -
- Temperature Accuracy ±: 1%
- Operating Temperature Max: 55°C
- Operating Temperature Min: -20°C
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 112.21 € |
| Current stock | 10+ |
| Lead time | 30 days |
**NEW Product** ## **Temperature Monitoring Relay K8AK-TH** ## **Compact and Slim Relay Ideal for Temperature Alarms and Monitoring** - Excessive temperature increases can be prevented and abnormal temperatures can be monitored. - Temperature monitoring in slim design with a width of just 22.5 mm. - Rotary switches simplifies temperature settings. - Universal-input support for thermocouple or platinum resistance thermometer sensor input. - Change the output relay between normally open and normally closed operation. - Alarm status identification with LED indicator. - Self-holding output. - Alarm output status can be retained even if the power supply is turned OFF. Refer to _Safety Precautions_ on page 8. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. ## **Ordering Information** ## **K8AK-TH (Temperature Input Models)** |**Power supply**<br>**voltage**|**Type**|**Output relays**|**Input types**|**Setting units (setting range)**|**Model**| |---|---|---|---|---|---| |100 to 240 VAC|Temperature<br>input|1 relay|Thermocouple or platinum<br>resistance thermometer|Setting unit: 1°C or 1°F (0 to 999°C/°F)|K8AK-TH11S 100-240VAC| ||||Thermocouple|Settingunit: 10°C/°F*|K8AK-TH12S 100-240VAC| |24 VAC/DC|||Thermocouple or platinum<br>resistance thermometer|Setting unit: 1°C or 1°F (0 to 999°C/°F)|K8AK-TH11S 24VAC/DC| ||||Thermocouple|Settingunit: 10°C/°F*|K8AK-TH12S 24VAC/DC| * Refer to _Setting Ranges_ on page 3 for the setting ranges. **Note:** When ordering, designate the power supply specification. Different Relay models are used for 100 to 240 VAC and 24 VAC/VDC. **1** **K8AK-TH** ## **Specifications** ## **Ratings** |**Item**<br>**Power supply voltage**|**Item**<br>**Power supply voltage**|**100 to 240 VAC 50/60 Hz**|**24 VAC 50/60 Hz or 24 VDC**| |---|---|---|---| |**Allowable voltage range**||85% to 110% of power supply voltage|| |**Power consumption**||5 VA max.|2 W max. (24 VDC), 4 VA max. (24 VAC)| |**Sensor inputs**|**K8AK-TH11S**|Thermocouple: K, J, T, E; Platinum-resistance thermometer: Pt100, Pt1000|| ||**K8AK-TH12S**|Thermocouple: K, J, T, E, B, R, S, PLII|| |**Output relay**||One SPDT relay (5 A at 250 VAC, resistive load)|| |**External inputs**<br>**(for latch setting)**|**Contact input**|ON: 1 kΩmax., OFF: 100 kΩmin.|| ||**Non-contact input**|ON residual voltage: 1.5 V max., OFF leakage current: 0.1 mA max.|| |||Leakage current: Approx. 10 mA|| |**Setting method**||Rotary switch setting (set of three switches)|| |**Indicators**||Power (PWR): Green LED, Relay output (ALM): Red LED|| |**Other functions**||Alarm Mode (upper limit/lower limit), non-fail safe/fail safe selection, output latch, setting protection, temperature<br>unit°C/°F|| |**Ambient operating temperature**||−20 to 55°C (with no condensation or icing)|| |**Ambient operating humidity**||Relative humidity: 25% to 85%|| |**Storage temperature**||−25 to 65°C (with no condensation or icing)|| ## **Characteristics** |**Characteristics**|**Characteristics**|| |---|---|---| |**Measurement accuracy**||K8AK-TH11S:±1% of the setting range or±4°C, whichever is larger<br>K8AK-TH12S:±1% of the setting range (±1% FS)| |**hysteresis width**||2°C| |**Output relay**||Rated load<br>Resistive load<br>5 A at 250 VAC<br>5 A at 30 VDC<br>Maximum switching capacity: 1,250 VA, 150 W<br>Minimum load: 5 VDC, 10 mA (reference values)<br>Mechanical life: 10 million operations min.<br>Electrical life:<br>5 A at 250 VAC or 30 VDC: 50,000 operations<br>3 A at 250 VAC/30 VDC: 100,000 operations| |**Sampling cycle**||100 ms| |**Insulation resistance**||20 MΩ(at 500 V) between charged terminals and exposed uncharged parts<br>20 MΩ(at 500 V) between any charged terminals (i.e., between input, output, and power supply terminals)<br>20 MΩ(at 500 V) between contacts (open)| |**Dielectric strength**||2,300 VAC, 50/60 Hz for 1 min between terminals of different charge| |**Vibration resistance**||Frequency: 10 to 55 Hz, 0.35-mm single amplitude<br>10 sweeps of 5 min each in X,Y, and Z directions| |**Shock resistance**||100 m/s2, 3 times each in 6 directions along 3 axes| |**Weight**||Approx. 160 g| |**Degree of protection**||IP20| |**Memory protection**||Non-volatile memory (number of writes: 1 million)| |**Safety**<br>**Standards**|**Approved standards**|UL 61010-1<br>Installation environment (pollution level 2, installation category II)| ||**EMC**|EN 61326-1 Industrial electromagnetic environment| ||**Application standards**|UL 61010-1 (Recognition), Korean Radio Waves Act (Act 10564), CSA: C22.2 No.14, CCC: GB14048.5| |**Terminal screw**|**tightening torque**|0.49 to 0.59 N·m| |**Crimp terminals**||Two solid wires of 2.5 mm2or two ferrules of 1.5 mm2with insulation sleeves can be tightened together.| |**Case color**||N1.5| |**Case material**||PC and ABS, UL 94 V-0| |**Mounting**||Mounts to DIN Track.| |**Dimensions**||22.5×100×90 mm (W×D×H)| **2** **K8AK-TH** ## **Setting Ranges** ## ● **K8AK-TH11S** ## **Centigrade** |●**K8AK-TH11S**<br>**Centigrade**||||||| |---|---|---|---|---|---|---| |**Input**|K|J|T|E|Pt100|Pt1000| |**Setting tempera-**<br>**ture range**<br>**1,000**<br>**800**<br>**600**<br>**400**<br>**200**<br>**0**|999|850|400|600|850|850| |||||||| |||||||| |||||||| |||||||| |||||||| ||0|0|0|0|0|0| |**Minimum setting increment**|1°C|||||| |**Fahrenheit**||||||| |**Input**|K|J|T|E|Pt100|Pt1000| |**Setting temperature**<br>**range**<br>**1,000**<br>**800**<br>**600**<br>**400**<br>**200**<br>**0**|999<br>|999<br>|700|999<br>|999<br>|999<br>| ||Å@|Å@||Å@|Å@|Å@| |||||||| |||||||| |||||||| |||||||| ||0|0|0|0|0|0| |**Minimum setting increment**|1°F|||||| ## ● **K8AK-TH12S** ## **Centigrade** |●**K8AK-TH12S**<br>**Centigrade**||||||||| |---|---|---|---|---|---|---|---|---| |**Input**|K|J|T|E|B|R|S|PLII| |**Setting temperature**<br>**range**<br>**1,800**<br>**1,700**<br>**1,600**<br>**1,500**<br>**1,400**<br>**1,300**<br>**1,200**<br>**1,100**<br>**1,000**<br>**900**<br>**800**<br>**700**<br>**600**<br>**500**<br>**400**<br>**300**<br>**200**<br>**100**<br>**0**|||||1,800|||| |||||||1,700|1,700|| |||||||||| |||||||||| |||||||||| ||1,300|||||||1,300| |||||||||| |||||||||| |||||||||| |||850||||||| |||||||||| |||||||||| |||||600||||| |||||||||| ||||400|||||| |||||||||| |||||||||| |||||||||| ||||||100|||| ||0|0|0|0||0|0|0| |**Minimum setting increment**|10°C|||||||| ## **Fahrenheit** |**Fahrenheit**||||||||| |---|---|---|---|---|---|---|---|---| |**Input**|K|J|T|E|B|R|S|PLII| |**Setting temperature**<br>**range**<br>**3,200**<br>**3,100**<br>**3,000**<br>**2,900**<br>**2,800**<br>**2,700**<br>**2,600**<br>**2,500**<br>**2,400**<br>**2,300**<br>**2,200**<br>**2,100**<br>**2,000**<br>**1,900**<br>**1,800**<br>**1,700**<br>**1,600**<br>**1,500**<br>**1,400**<br>**1,300**<br>**1,200**<br>**1,100**<br>**1,000**<br>**900**<br>**800**<br>**700**<br>**600**<br>**500**<br>**400**<br>**300**<br>**200**<br>**100**<br>**0**|||||3,200|||| |||||||||| |||||||3,000|3,000|| |||||||||| |||||||||| |||||||||| |||||||||| |||||||||| |||||||||| ||2,300|||||||2,300| |||||||||| |||||||||| |||||||||| |||||||||| |||||||||| |||||||||| |||||||||| |||1,500||||||| |||||||||| |||||||||| |||||||||| |||||1,100||||| |||||||||| |||||||||| ||||700|||||| |||||||||| |||||||||| |||||||||| |||||||||| |||||||||| ||||||300|||| |||||||||| |||||||||| ||0|0|0|0||0|0|0| |**Minimum setting increment**|10°F|||||||| ## ● **Temperature Input Range** |**TH11S**|°**C**|°**C**|°**F**|°**F**||**TH12S**|°**C**|°**C**|°**F**|°**F**| |---|---|---|---|---|---|---|---|---|---|---| |**Input**<br>**type**|Lower<br>limit|Upper<br>limit|Lower<br>limit|Upper<br>limit||**Input**<br>**type**|Lower<br>limit|Upper<br>limit|Lower<br>limit|Upper<br>limit| |**K**|−20|1019|−40|1039||**K**|−20|1320|−40|2340| |**J**|−20|870|−40|1039||**J**|−20|870|−40|1540| |**T**|−20|420|−40|740||**T**|−20|420|−40|740| |**E**|−20|620|−40|1039||**E**|−20|620|−40|1140| |**Pt100**|−20|870|−40|1039||**B**|0|1820|0|3240| |**Pt1000**|−20|870|−40|1039||**R**|−20|1720|−40|3040| |**---**|---|---|---|---||**S**|−20|1720|−40|3040| |**---**|---|---|---|---||**PLII**|−20|1320|−40|2340| **3** **K8AK-TH** ## **Connections** ## **Wiring Diagrams** ## **K8AK-TH11S** ## **K8AK-TH12S** **==> picture [326 x 197] intentionally omitted <==** **----- Start of picture text -----**<br> Power supply Power supply<br>voltage* [1] voltage* [1]<br>Not used. Not used.<br>Power supply A1 A2 Power supply A1 A2<br>Relay output 14 11 12 Relay output 14 11 12<br>External input External input<br>(LATCH_RST)* [2] 4 5 6 Not used. (LATCH_RST)* [2] 4 5 6 Not used.<br>Sensor input 1 2 3 Sensor input 1 2 3 Not used.<br>+ − + −<br>Thermocouple B B A<br>Thermocouple<br>Pt resistance thermometer input<br>**----- End of picture text -----**<br> - *1 The input power supply depends on the model: 100 to 240 VAC or 24 VAC/VDC (no polarity) - *2 Wiring of the external input terminals is as shown below. ## **Timing Charts** Temperature Alarm: Hysteresis: 2°C/°F **==> picture [226 x 213] intentionally omitted <==** **----- Start of picture text -----**<br> 2°C (°F)<br>Temperature setting<br>2°C (°F)<br>Temperature alarm upper limit (11) to (14)<br>Temperature alarm lower limit (11) to (14)<br>Changing between Normally Open and Normally Closed<br>Power supply<br>Temperature alarm or other error<br>Relay output (normally open) (11) to (14)<br>Relay output (normally closed) (11) to (14)<br>* Other errors: sensor open circuit error, sensor input error, temperature setting<br>error, and memory error.<br>Latched Operation: Relay outputs remain latched even after the alarm<br>or error is reset.<br>Power supply<br>Temperature alarm or other error<br>LATCH_RST or external inputs (4) to (5)<br>Relay output (latched) (11) to (14)<br>0.02 s<br>**----- End of picture text -----**<br> - If LATCH_RST is enabled, the alarm status is retained even if the power supply is cycled. - To clear the alarm status, press the LATCH_RST button or turn ON the external input. (Default: Latching enabled.) **==> picture [225 x 109] intentionally omitted <==** **----- Start of picture text -----**<br> Operation of Indicators<br>Power supply<br>SV Protect Mode<br>Flashing<br>PWR indicator<br>Power supply<br>Temperature alarm<br>Other error<br>ALM indicator Flashing<br>**----- End of picture text -----**<br> **4** **K8AK-TH** **Nomenclature** ## **Front Operations** ## ● **Error (ALM indicator: Flashing)** **==> picture [112 x 227] intentionally omitted <==** **----- Start of picture text -----**<br> Power supply<br>Relay output<br>R_SW3<br>Temperature unit (Black<br>out the unnecessary<br>label: °C or °F)<br>PWR Indicator (Green)<br>R_SW2<br>ALM indicator (Red)<br>R_SW1<br>LATCH_RST<br>button*<br>External input<br>(LATCH_RST)<br>Sensor input<br>**----- End of picture text -----**<br> **One of the following items 1 to 3 has occurred.** **1. The sensor circuit is disconnected or the temperature setting is out of the specified range.** **2. The temperature setting is out of the specified range.** **3. There is a problem in the internal circuits.** - **Corrections** **1. Disable SV Protect Mode.** **2. Disable the latch.** **3. Check for incorrect wiring, circuit disconnections, short circuits, and whether the input type and temperature settings are correct.** ## **4. If the wiring and settings are correct, reset the power supply.** ## **If the Unit resumes normal operation, the problem may have been caused by noise. If the Unit does not resume normal operation, it must be replaced.** - The non-volatile memory stores the event when a latched output is disabled, or the SV Protect Mode is enabled or disabled. An error may occur if the data is updated more than one million times. - If you press and hold the LATCH_RST button for 5 seconds or longer, the SV Protect Mode will go into effect. - When SV Protect Mode is enabled, the PWR indicator flashes. To disable the SV Protect Mode, press and hold the LATCH_RST Button for at least 5 seconds. ## ● **Alarm Setting Rotary Switch** Point the arrow to the required number. - **Note: 1.** Use solid-core wires of 2.5-mm[2] max. or ferrules with an insulation sleeve to wire to this terminal. - To ensure the dielectric strength of the connection, do not expose more than 8 mm of wire for insertion into the terminal. For a solid wire For ferrules with of 2.5-mm[2] of max. an insulation sleeve. 8 mm max. 8 mm max. Recommended Ferrules Phoenix Contact Al 1.5-8BK (for AWG16) - •Al 1-8RD (for AWG18) - •Al 0,75-8GY (for AWG18) **2.** Screw tightening torque: 0.49 to 0.59 N·m **5** **K8AK-TH** **Operation Method** ## **Function Selection DIP Switch** **==> picture [508 x 238] intentionally omitted <==** **----- Start of picture text -----**<br> Settings<br>K8AK-TH11S R_SW3 100°C/°F units (0 to 9) K8AK-TH12S 1,000°C/°F units (0 to 3)<br>R_SW3 * A temperature setting error<br>R_SW2 10°C/°F units (0 to 9) occurs if this switch is set to a<br>value from 4 to 9.<br>R_SW1 1°C/°F units (0 to 9) R_SW2 100°C/°F units (0 to 9)<br>* Default: 0°C<br>R_SW1 10°C/°F units (0 to 9)<br>SW * Default: 0°C<br>1 2 3 4 5 6 7<br>Upper limit alarm Input type SW<br>Switch (SW) Lower limit alarm K 1 2 3 4 5 6 7<br>ON With latching J Upper limit alarm Input type<br>OFF Without latching T Lower limit alarm K<br> Normally open E ON With latching J<br>* Default settings: All OFF Normally closed Pt100 OFF Without latching T<br>Turn OFF the power to the Temperature ° [C ] Pt1000 Normally open E ON<br>Monitoring Relay before you change the switch settings on the side panel. ° [F ] Not used. Normally closed B OFF<br>The switch settings made on the side panel * Default: All OFF.* SW8: Not used. Not used. ° [C ] R<br>take effect when the power is turned ON. ° [F ] S<br>Use a precision screwdriver to manipulate * Default: All OFF. PLII<br>the switches and button. * SW8: Not used.<br>Safety standards EN 61010-1<br>EMI EN 61326-1<br>EMC<br>EMS EN 61326-1<br>**----- End of picture text -----**<br> **6** **K8AK-TH** ## **Functions** ## ● **SV Protection** This function protects (i.e., prohibits changing) the alarm setting, operating method, and modes for the Temperature Monitoring Relay that have been set on the rotary switches and DIP switch. The protection function is activated by pressing the output latch reset button on the Temperature Monitoring Relay for at least 5 s or by turning ON the input to the external input terminal for at least 5 s. The power indicator will flash when the protection is activated. The protection function can be released by pressing the output latch reset button on the Temperature Monitoring Relay for at least 5 s or by turning ON the input to the external input terminal for at least 5 s. The power indicator will light while the protection is being reset. ## **Dimensions** **(Unit: mm)** **==> picture [213 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Note: All units are in millimeters unless otherwise indicated.<br>**----- End of picture text -----**<br> **==> picture [182 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> Temperature Monitoring Relay<br>**----- End of picture text -----**<br> **==> picture [482 x 251] intentionally omitted <==** **----- Start of picture text -----**<br> K8AK-TH _ 22.5 100<br>90<br>= [eee oo. ,<br>5<br>Track Mounting Products (Sold Separately)<br>● DIN Tracks<br>PFP-100N 7.3 [±][0.15]<br>PFP-50N 4.5<br>35 [±][0.3] 27 [±][0.15]<br>ry:<br>15 25 10 251000 (500) (See note.)25 10 25 15 (5) (See note.) 1<br>*<br>ess: [He] Dimensions in parentheses are for the PFP-50N. 4 dee<br>**----- End of picture text -----**<br> **7** **K8AK-TH** ## **Safety Precautions** ## **Be sure to read the precautions for all models in the website at the following URL: http://www.ia.omron.com/.** ## **Warning Indications** |**CAUTION**|Indicates a potentially hazardous situation<br>which, if not avoided, may result in minor or<br>moderate injury or in property damage.| |---|---| |**Precautions for Safe**<br>**Use**|Supplementary comments on what to do or<br>avoid doing, to use the product safely.| |**Precautions for**<br>**Correct Use**|Supplementary comments on what to do or<br>avoid doing, to prevent failure to operate,<br>malfunction, or undesirable effects on<br>product performance.| ## **Meaning of Product Safety Symbols** **==> picture [33 x 107] intentionally omitted <==** Used to warn of the risk of electric shock under specific conditions. Used for general prohibitions for which there is no specific symbol. Used to indicate prohibition when there is a risk of minor injury from electrical shock or other source if the product is disassembled. Used for general mandatory action precautions for which there is no specified symbol. ## **CAUTION** Electrical shock may cause minor injury. Do not touch terminals while electricity is being supplied. There is a risk of minor electrical shock, fire, or device failure. Do not allow any pieces of metal, conductors, or cutting chips that occur during the installation process to enter the product. Explosions may cause minor injuries. Do not use the product in locations with inflammable or explosive gases. There is a risk of minor electrical shock, fire, or device failure. Do not disassemble, modify, repair, or touch the inside of the product. Loose screws may cause fires. Tighten terminal screws to the specified torque of 0.49 to 0.59 N·m. Use of excessive torque may damage the terminal screws. Tighten terminal screws to the specified torque of 0.49 to 0.59 N·m. If the setting does not match the element to be monitored, the product may behave unexpectedly and damage the machine or cause accidents. Set the Temperature Monitoring Relay as described below. - Adjust each set value on the Temperature Monitoring Relay correctly for the element that is to be monitored. - Turn OFF the power to the Temperature Monitoring Relay before you change the switch settings on the side panel. The switch settings made on the side panel take effect when the power is turned ON. If the Temperature Monitoring Relay fails, monitoring and alarm outputs may fail to operate. This may result in physical damage to the facilities, equipment, or other devices that are connected to it. To reduce this risk, inspect the product regularly. To make the product fail-safe, take alternative safety measures, such as the installation of monitoring devices on a separate circuit. Use of the product beyond its life may result in contact welding or burning. Make sure to consider the actual operating conditions and use the product within its rated load and electrical life count. The life of the output relay varies significantly with the switching capacity and switching conditions. **8** **K8AK-TH** ## **Precautions for Safe Use** **1.** Do not use or store the product in the following locations. - Locations subject to water or oil - Locations subject to direct radiant heat from heating equipment - Outdoor locations or under direct sunlight - Locations subject to dust or corrosive gases (particularly sulfurizing gases, ammonia, etc.) - Locations subject to rapid temperature changes - Locations prone to icing and dew condensation - Locations subject to excessive vibration or shock **2.** Use and store the product in a location where the ambient temperature and humidity are within the specified ranges. If applicable, provide forced cooling. **3.** Mount the product in the correct direction. **4.** Check terminal polarity when wiring and wire all connections correctly. The power supply terminals do not have polarity. **5.** Do not wire the input and output terminals incorrectly. **6.** Make sure the power supply voltage and loads are within the specifications and ratings for the product. **7.** Make sure the type of the thermocouple matches the input type that the Temperature Monitoring Relay is designed for. **8.** If you need to extend the length of the lead wires on the thermocouple, make sure to match the type of thermocouple and always use compensating conductors. **9.** To extend the lead wires on the platinum resistance thermometer, use lead wires with a low resistance (5 Ω or less per wire), and make the resistance equal on all three lead wires. **10.** Make sure the crimp terminals for wiring are of the specified size. **11.** Do not connect anything to terminals that are not being used. **12.** Use a power supply that will reach the rated voltage within 1 second after the power is turned ON. **13.** After you turn ON the power, it takes 2 seconds for the outputs of the Temperature Monitoring Relay to stabilize. Take this time into account when you design the control panel. ## **Precautions for Correct Use** ## **Observe the following operating methods to prevent failure and malfunction.** **1.** Use the power supply voltage, input power, and other power supplies and converters with suitable capacities and rated outputs. **2.** Use a precision screwdriver or similar tool to adjust the rotary switches. ## **Correct Mounting Direction, Mounting, and Removing** - Mounting to DIN Track 1. Attach the product to the DIN Track with the tab at the top and the hooks at the bottom. 2. Push the product onto the Track until the hooks lock into place. **==> picture [134 x 107] intentionally omitted <==** **----- Start of picture text -----**<br> A B<br>**----- End of picture text -----**<br> - Removing from the DIN Track Pull down on the bottom hook with a flat-blade screwdriver and lift up on the product. **14.** Allow at least 30 minutes for the product to warm up. During this time, the temperature measurements will be incorrect. **15.** Keep wiring separate from high voltages and power lines that draw large currents. - Do not place product wiring in parallel with or in the same path as high-voltage or high-current lines. **16.** Do not install the product near equipment that generates high frequencies or surges. **17.** The product may cause incoming radio wave interference. Do not use the product near radio wave receivers. **==> picture [76 x 24] intentionally omitted <==** **----- Start of picture text -----**<br> Applicable DIN Tracks:<br>PFP-100N (100 cm)<br>PFP-50N (50 cm)<br>**----- End of picture text -----**<br> **18.** Install an external switch or circuit breaker and label it clearly so that the operator can quickly turn OFF the power supply. **19.** When cleaning the product, do not use thinners or solvents. Use commercial alcohol. **20.** When discarding the product, properly dispose of it as industrial waste. **21.** Make sure the power and output indicators operate correctly. Depending on the application environment, the indicators and other plastic parts may wear prematurely and become difficult to see. Check and replace these parts regularly. **22.** The terminal blocks may heat up to 65°C. Use care when handling them. **9** **MEMO** **10** ## **Terms and Conditions Agreement** ## **Read and understand this catalog.** Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. ## **Warranties.** (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. ## **Limitation on Liability; Etc.** OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. ## **Suitability of Use.** Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. ## **Programmable Products.** Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. ## **Performance Data.** Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. ## **Change in Specifications.** Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. ## **Errors and Omissions.** Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. **==> picture [185 x 87] intentionally omitted <==** **----- Start of picture text -----**<br> Authorized Distributor:<br>**----- End of picture text -----**<br> ## **OMRON Corporation Industrial Automation Company** **Tokyo, JAPAN** **Contact: www.ia.omron.com** _**Regional Headquarters**_ **OMRON EUROPE B.V.** Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 **OMRON ELECTRONICS LLC** One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 © OMRON Corporation 2014 All Rights Reserved. **OMRON (CHINA) CO., LTD.** Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China CSM_4 _ 2 _ 0317 Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 **OMRON ASIA PACIFIC PTE. LTD.** No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 In the interest of product improvement, specifications are subject to change without notice. **Cat. No. N187-E1-01** _ 2 _ 0317 0314 (0314)0513
Updated at April 14, 2026
With a legacy spanning over 80 years, Omron Industrial Automation is a globally recognized leader in the manufacture of advanced industrial control and automation components. Renowned for their reliability and engineering excellence, Omron delivers comprehensive solutions that enhance efficiency, machine safety, and precision across a wide range of manufacturing environments. Our extensive portfolio of Omron products is heavily focused on their industry-leading sensing and switching technologies. We offer a vast selection of sensors, excelling specifically in high-performance proximity sensors, light sensors, and temperature sensors. Complementing this range are robust switching solutions, featuring a deep inventory of power relays, solid-state relays, safety relays, and essential relay accessories designed for demanding operational requirements. Beyond sensing and switching, Omron is highly regarded for its precision automation and process control equipment. Our selection features highly accurate temperature controllers, versatile process controllers, and sophisticated panel displays and instrumentation. To support these fundamental systems, we also supply dependable Omron power supplies, notably AC/DC converters, alongside vital connectivity components like DIN rail terminal blocks to ensure secure, efficient, and complete industrial setups.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →